Program for Automated Real-Time Monitoring

Process-control decisions made by applying rules to process data streams. Expert System Executive computer program demonstrates feasibility of automated real-time monitoring. Using Executives knowledge of system formally coded as set of rules specifying actions taken under various conditions. Program makes inferences about observed data based on rules. Written in C language.

Goodrum, Glenn R.↗

Science Goal Monitor: Science Goal Driven Automation for NASA Missions

Infusion of automation technologies into NASA s future missions will be essential because of the need to: (1) effectively handle an exponentially increasing volume of scientific data, (2) successfully meet dynamic, opportunistic scientific goals and objectives, and (3) substantially reduce mission operations staff and costs. While much effort has gone into automating routine spacecraft operations to reduce human workload and hence costs, applying intelligent automation to the science side, i.e., science data acquisition, data analysis and reactions to that data analysis in a timely and still scientifically valid manner, has been relatively under-emphasized. In order to introduce science driven automation in missions, we must be able to: capture and interpret the science goals of observing programs, represent those goals in machine interpretable language; and allow spacecrafts onboard systems to autonomously react to the scientist's goals. In short, we must teach our platforms to dynamically understand, recognize, and react to the scientists goals. The Science Goal Monitor (SGM) project at NASA Goddard Space Flight Center is a prototype software tool being developed to determine the best strategies for implementing science goal driven automation in missions. The tools being developed in SGM improve the ability to monitor and react to the changing status of scientific events. The SGM system enables scientists to specify what to look for and how to react in descriptive rather than technical terms. The system monitors streams of science data to identify occurrences of key events previously specified by the scientist. When an event occurs, the system autonomously coordinates the execution of the scientist s desired reactions. Through SGM, we will improve om understanding about the capabilities needed onboard for success, develop metrics to understand the potential increase in science returns, and develop an operational prototype so that the perceived risks associated with increased use of automation can be reduced.

Koratkar, Anuradha↗

Real-time reasoning - The monitoring and control of spacecraft systems

Research concerned with automating the monitoring and control of spacecraft systems is discussed. In particular, the application the Procedural Reasoning System (PRS) to the handling of malfunctions in the Reaction Control System (RCS) of NASAs space shuttle is studied. Unlike traditional monitoring and control systems, PRS is able to reason about and perform complex tasks in a very flexible and robust manner, somewhat in the manner of a human assistant. Using various RCS malfunctions as examples (including sensor faults, leaking components, multiple alarms, and regulator and jet failures), it is shown how PRS manages to combine both goal-directed reasoning and the ability to react rapidly to unanticipated changes in its environment. Some important issues in the design of PRS are reviewed, and future enhancements are indicated.

Georgeff, Michael P.↗

PHYSICS-BASED AUTOMATED REASONING FOR HEALTH MONITORING: SENSOR SET SELECTION

This paper addresses the problem of how to select a sensor set for equipment health monitoring that meets the needs of advanced O&M tasks that target cost reduction. They include maintenance optimization and asset management for the existing fleet and near-autonomous operation as currently envisioned for advanced reactors. The method uses physics-based automated reasoning to provide for a more “explainable” diagnosis. The algorithm is described along with its implementation on a computational cluster. Preliminary results for application to a use case in the current fleet are described.

diagnosis↗

Systems and methods for monitoring traffic on industrial control and building automation system networks

Technologies relating to monitoring communications traffic to detect potential attacks on industrial control system networks and building automation system networks are described herein. In an embodiment, a monitoring device receives a plurality of communications from a control network. The monitoring device transmits the communications to a computing device. Based on the communications, the computing device generates a listing of devices that communicated by way of the control network over a period of time, and computes a volume of traffic between each pair of devices in the listing of devices. The computing device then outputs a graphical user interface (GUI) by way of display, the GUI comprising data indicative of the computed volumes of traffic, which may be indicative of a potential attack on the control network.

Jenkins, Chris↗

CO 2 Injection Monitoring with a Scalable, Automated Sparse Seismic Array

Conference presentation at American Institute of Chemical Engineers (AIChE) Annual Meeting, Virtual, November 16–20, 2020. The scalable, automated sparse seismic array (SASSA) method has been ideated as a cost-effective alternative or complementary to conventional 3D seismic methods. Based on a sparse array of receivers deployed strategically on Earth’s surface and one or more fixed seismic sources, the SASSA method can be used to study specific portions of the subsurface to detect the movement of CO 2 in a reservoir with lower environmental footprint and shorter turnaround time to deliver results than conventional 3D seismic methods. Energy & Environmental Research Center (EERC) carried out seismic monitoring of an oilfield undergoing CO 2 enhanced oil recovery in Montana, USA, using the SASSA method.

02 PETROLEUM↗

An automated system for continuous monitoring of CO 2 geosequestration using multi-well offset VSP with permanent seismic sources and receivers: Stage 3 of the CO2CRC Otway Project

Time-lapse seismic is an essential tool for monitoring CO 2 injection into the subsurface but suffers from high cost and long intervals between surveys. An alternative approach is continuous monitoring using permanent sources and receivers capable of mapping CO 2 plume evolution on an almost daily basis and drastically reduce human effort, cost and survey turnaround. As part of the CO2CRC Otway project, a continuous monitoring system is employed to monitor a small (15,000 tonnes) CO 2 injection within the CO2CRC Otway Project. The permanent monitoring system employs distributed acoustic sensors (DAS) installed in boreholes as seismic receivers and seismic orbital vibrators (SOV) as seismic sources. The monitoring approach is based on vertical seismic profiling using five wells equipped with DAS cemented behind the casing and nine SOVs and is acquiring the data continuously in an autonomous manner. The data is then automatically processed on-site producing a seismic image every 2.5 days, which is then transmitted to a remote office. The data has good repeatability with NRMS of about ~10-15%.

58 GEOSCIENCES↗

Development of an automated potable water bactericide monitoring unit

A monitor unit has been developed that permits the direct determination of the level of elemental iodine, used for microbiological control, in a spacecraft potable water supply system. Salient features of unit include low weight, volume and maintenance requirements, complete automatic operation, no inflight calibration, no expendables (except electrical current) and high accuracy and precision. This unit is capable of providing a signal to a controller that, in turn, automatically adjusts the addition rate of iodine to the potable water system so that a predetermined level of iodine can be maintained. In addition, the monitor provides a reading whereby the crewman can verify that the proper amount of iodine (within a range) is present in the water. A development history of the monitor is presented along with its design and theory of operation. Also presented are the results generated through testing of the unit in a simulated Shuttle potable water system.

Walsh, J. M.↗

Effects of shifts in the level of automation on operator performance

The results of two experiments examining the effects of shifts in the type and level of automation on operator performance are presented. The first examines the costs and benefits of adaptive-automation shifts on operator performance, while the second experiment examines the effects of variations in automation reliability on operator detection of automation failures. Performance consequences of complacency in system monitoring are shown to be related to characteristics of the monitoring task automation, i.e., automation reliability and consistency.

Parasuraman, Raja↗

Operations automation using the Link Monitor and Control Operator Assistant

The Link Monitor and Control Operator Assistant (LMC OA) is a knowledge-based prototype system which uses AI techniques to provide semiautomated monitor and control functions to support operations of the Deep Space Network (DSN) 70-m antenna at the Goldstone Deep Space Communications Complex (DSCC). The manual and time-consuming process of configuring the 70-m antenna and its associated communications and processing equipment, known as precalibration, is an overhead activity; the time spent in precalibration is time which cannot be spent supporting actual mission operations. Therefore, the major goal of the LMC OA task is to demonstrate techniques that reduce precalibration time, decrease operations overhead, and increase the availability of this valuable and oversubscribed NASA resource. The LMC OA prototype was tested in a parallel, experimental mode at the Goldstone DSCC performing semiautomated precalibration using the actual operational equipment. This test demonstrated that a reduction of 40 percent in precalibration time can be achieved with the LMC OA prototype.

Lee, Lorrine F.↗

Monitoring and control of spacecraft systems using procedural reasoning

Research concerned with automating the monitoring and control of spacecraft systems is discussed. In particular, the application of SRI's Procedural Reasoning System (PRS) to the handling of malfunctions in the Reaction Control System (RCS) of NASA's Space Shuttle is examined. Unlike traditional monitoring and control systems, PRS is able to reason about and perform complex tasks in a very flexible and robust manner, somewhat in the manner of a human assistant. Using various RCS malfunctions as examples (including sensor faults, leaking components, multiple alarms, and regulator and jet failures), it is shown how PRS manages to combine both goal-directed reasoning and the ability to react rapidly to unanticipated changes in its environment. In conclusion, some important issues in the design of PRS are reviewed and future enhancements are indicated.

Georgeff, Michael P.↗

Attention focusing and anomaly detection in systems monitoring

Any attempt to introduce automation into the monitoring of complex physical systems must start from a robust anomaly detection capability. This task is far from straightforward, for a single definition of what constitutes an anomaly is difficult to come by. In addition, to make the monitoring process efficient, and to avoid the potential for information overload on human operators, attention focusing must also be addressed. When an anomaly occurs, more often than not several sensors are affected, and the partially redundant information they provide can be confusing, particularly in a crisis situation where a response is needed quickly. The focus of this paper is a new technique for attention focusing. The technique involves reasoning about the distance between two frequency distributions, and is used to detect both anomalous system parameters and 'broken' causal dependencies. These two forms of information together isolate the locus of anomalous behavior in the system being monitored.

Doyle, Richard J.↗

Algorithm Helps Monitor Engine Operation

Real-Time Failure Control (RTFC) algorithm part of automated monitoring-and-shutdown system being developed to ensure safety and prevent major damage to equipment during ground tests of main engine of space shuttle. Includes redundant sensors, controller voting logic circuits, automatic safe-limit logic circuits, and conditional-decision logic circuits, all monitored by human technicians. Basic principles of system also applicable to stationary powerplants and other complex machinery systems.

Eckerling, Sherry J.↗

A Distance Measure for Attention Focusing and Anomaly Detection in Systems Monitoring

Any attempt to introduce automation into the monitoring of complex physical systems must start from a robust anomaly detection capability. This task is far from straightforward, for a single definition of what constitutes an anomaly is difficult to come by. In addition, to make the monitoring process efficient, and to avoid the potential for information overload on human operators, attention focusing must also be addressed. When an anomaly occurs, more often than not several sensors are affected, and the partially redundant information they provide can be confusing, particularly in a crisis situation where a response is needed quickly. Previous results on extending traditional anomaly detection techniques are summarized. The focus of this paper is a new technique for attention focusing.

attention focusing systems monitoring anomaly dete↗

Attention Focusing and Anomaly Detection in Systems Monitoring

Any attempt to introduce automation into the monitoring of complex physical systems must start from a robust anomaly detection capability. This task is far from straightforward, for a single definition of what constitutes an anomaly is difficult to come by. In addition, to make the monitoring process efficient, and to avoid the potential for information overload on human operators, attention focusing must also be addressed. When an anomaly occurs, more often than not several sensors are affected, and the partially redundant information they provide can be confusing, particularly in a crisis situation where a response is needed quickly.

systems↗