Advanced Data Acquisition Systems with Self-Healing Circuitry

Kennedy Space Center's Spaceport Engineering & Technology Directorate has developed a data acquisition system that will help drive down the cost of ground launch operations. This system automates both the physical measurement set-up function as well as configuration management documentation. The key element of the system is a self-configuring, self-calibrating, signal-conditioning amplifier that automatically adapts to any sensor to which it is connected. This paper will describe the core technology behind this device and the automated data system in which it has been integrated. The paper will also describe the revolutionary enhancements that are planned for this innovative measurement technology. All measurement electronics devices contain circuitry that, if it fails or degrades, requires the unit to be replaced, adding to the cost of operations. Kennedy Space Center is now developing analog circuits that will be able to detect their own failure and dynamically reconfigure their circuitry to restore themselves to normal operation. This technology will have wide ranging application in all electronic devices used in space and ground systems.

Larson, William E.↗

AN INTRODUCTION TO THE GEONEX LEVEL-1G PRODUCTS: TOP-OF-ATMOSPHERE REFLECTANCE AND BRIGHTNESS TEMPERATURE

This paper introduces the GeoNEX (Geostationary-NASA Earth eXchange) Level-1G products of top-of-atmosphere (TOA) reflectance and brightness temperature. The products use data streams from the latest geostationary (GEO) sensors including the GOES-16/17 ABI and the Himawari-8/9 AHI. The GeoNEX processing pipeline starts by converting digital numbers to physical quantities with the latest radiometric calibration information. It integrates algorithms to automatically detect and remove residual geolocation errors, to estimate the pixel-wise data-acquisition time, and to accurately calculate the solar illumination angles for each pixel in the domain at every time step. The outputs are reprojected to a globally tiled common grid in geographic coordinates designed to facilitate inter-comparisons and/or synergies between the GeoNEX products and existing Earth observation datasets from polar-orbiting satellites. Therefore, the GeoNEX L1G products provide accurate and consistent TOA reflectance and brightness temperature datasets for scientific analyses and downstream product development.

Geostationary satellite, GOES-16, Himawari-8, NASA↗

Improved pressure measurement system for calibration of the NASA LeRC 10x10 supersonic wind tunnel

This paper discusses a method used to provide a significant improvement in the accuracy of the Electronically Scanned Pressure (ESP) Measurement System by means of a fully automatic floating pressure generating system for the ESP calibration and reference pressures. This system was used to obtain test section Mach number and flow angularity measurements over the full envelope of test conditions for the 10 x 10 Supersonic Wind Tunnel. The uncertainty analysis and actual test data demonstrated that, for most test conditions, this method could reduce errors to about one-third to one-half that obtained with the standard system.

Blumenthal, Philip Z.↗

Wind Tunnel Force Balance Calibration Study - Interim Results

Wind tunnel force balance calibration is preformed utilizing a variety of different methods and does not have a direct traceable standard such as standards used for most calibration practices (weights, and voltmeters). These different calibration methods and practices include, but are not limited to, the loading schedule, the load application hardware, manual and automatic systems, re-leveling and non-re-leveling. A study of the balance calibration techniques used by NASA was undertaken to develop metrics for reviewing and comparing results using sample calibrations. The study also includes balances of different designs, single and multi-piece. The calibration systems include, the manual, and the automatic that are provided by NASA and its vendors. The results to date will be presented along with the techniques for comparing the results. In addition, future planned calibrations and investigations based on the results will be provided.

Rhew, Ray D.↗

Multi-band automatic sun and sky scanning radiometer system for measurement of aerosols

A weather resistant automatic scanning Sun photometer system is assessed and demonstrated as practical for measurements of aerosol concentrations and properties at remote sites. Interfaced with a transmitter using the Geostationary Data Collection System (GDCS), the data are processed in near real time. The processing allows a time dependence of the aerosols and water vapor and an ongoing assessment of the health and calibration of the instruments. The system's automatic data acquisition, transmission, and processing offer immediate application to atmospheric monitoring and modeling on a regional to global scale and validation of satellite retrievals. It is estimated that under normal circumstances the retrieved aerosol optical thickness has a network wide accuracy of +/- 0.02 from 340 nm to 1020 nm, water vapor +/- 0.2 cm and size distribution from 0.1 to 3 micrometers.

Holben, B. N.↗

Wireless Acoustic Measurement System

A prototype wireless acoustic measurement system (WAMS) is one of two main subsystems of the Acoustic Prediction/Measurement Tool, which comprises software, acoustic instrumentation, and electronic hardware combined to afford integrated capabilities for predicting and measuring noise emitted by rocket and jet engines. The other main subsystem is described in "Predicting Rocket or Jet Noise in Real Time" (SSC-00215-1), which appears elsewhere in this issue of NASA Tech Briefs. The WAMS includes analog acoustic measurement instrumentation and analog and digital electronic circuitry combined with computer wireless local-area networking to enable (1) measurement of sound-pressure levels at multiple locations in the sound field of an engine under test and (2) recording and processing of the measurement data. At each field location, the measurements are taken by a portable unit, denoted a field station. There are ten field stations, each of which can take two channels of measurements. Each field station is equipped with two instrumentation microphones, a micro-ATX computer, a wireless network adapter, an environmental enclosure, a directional radio antenna, and a battery power supply. The environmental enclosure shields the computer from weather and from extreme acoustically induced vibrations. The power supply is based on a marine-service lead-acid storage battery that has enough capacity to support operation for as long as 10 hours. A desktop computer serves as a control server for the WAMS. The server is connected to a wireless router for communication with the field stations via a wireless local-area network that complies with wireless-network standard 802.11b of the Institute of Electrical and Electronics Engineers. The router and the wireless network adapters are controlled by use of Linux-compatible driver software. The server runs custom Linux software for synchronizing the recording of measurement data in the field stations. The software includes a module that provides an intuitive graphical user interface through which an operator at the control server can control the operations of the field stations for calibration and for recording of measurement data. A test engineer positions and activates the WAMS. The WAMS automatically establishes the wireless network. Next, the engineer performs pretest calibrations. Then the engineer executes the test and measurement procedures. After the test, the raw measurement files are copied and transferred, through the wireless network, to a hard disk in the control server. Subsequently, the data are processed into 1/3-octave spectrograms.

Anderson, Paul D.↗

Wireless Acoustic Measurement System

A prototype wireless acoustic measurement system (WAMS) is one of two main subsystems of the Acoustic Prediction/ Measurement Tool, which comprises software, acoustic instrumentation, and electronic hardware combined to afford integrated capabilities for predicting and measuring noise emitted by rocket and jet engines. The other main subsystem is described in the article on page 8. The WAMS includes analog acoustic measurement instrumentation and analog and digital electronic circuitry combined with computer wireless local-area networking to enable (1) measurement of sound-pressure levels at multiple locations in the sound field of an engine under test and (2) recording and processing of the measurement data. At each field location, the measurements are taken by a portable unit, denoted a field station. There are ten field stations, each of which can take two channels of measurements. Each field station is equipped with two instrumentation microphones, a micro- ATX computer, a wireless network adapter, an environmental enclosure, a directional radio antenna, and a battery power supply. The environmental enclosure shields the computer from weather and from extreme acoustically induced vibrations. The power supply is based on a marine-service lead-acid storage battery that has enough capacity to support operation for as long as 10 hours. A desktop computer serves as a control server for the WAMS. The server is connected to a wireless router for communication with the field stations via a wireless local-area network that complies with wireless-network standard 802.11b of the Institute of Electrical and Electronics Engineers. The router and the wireless network adapters are controlled by use of Linux-compatible driver software. The server runs custom Linux software for synchronizing the recording of measurement data in the field stations. The software includes a module that provides an intuitive graphical user interface through which an operator at the control server can control the operations of the field stations for calibration and for recording of measurement data. A test engineer positions and activates the WAMS. The WAMS automatically establishes the wireless network. Next, the engineer performs pretest calibrations. Then the engineer executes the test and measurement procedures. After the test, the raw measurement files are copied and transferred, through the wireless network, to a hard disk in the control server. Subsequently, the data are processed into 1.3-octave spectrograms.

Anderson, Paul D.↗

A miniature remote deadweight calibrator

A miniature, computer-controlled, deadweight calibrator was developed to remotely calibrate a force transducer mounted in a cryogenic chamber. This simple mechanism allows automatic loading and unloading of deadweights placed onto a skin friction balance during calibrations. Equipment for the calibrator includes a specially designed set of five interlocking 200-milligram weights, a motorized lifting platform, and a controller box taking commands from a microcomputer on an IEEE interface. The computer is also used to record and reduce the calibration data and control other calibration parameters. The full-scale load for this device is 1,000 milligrams; however, the concept can be extended to accommodate other calibration ranges.

Supplee, Frank H., Jr.↗

National transonic facility Mach number system

The Mach number system for the Langley Research Center's National Transonic Facility was designed to measure pressures to determine Mach number to within + or - 0.002. Nine calibration laboratory type fused quartz gages, four different range gages for the total pressure measurement, and five different range gages for the static pressure measurement were used to satisfy the accuracy requirement over the 103,000-890,000 Pa total pressure range of the tunnel. The system which has been in operation for over 1 year is controlled by a programmable data process controller to select, through the operation of solenoid valves, the proper range fused quartz gage to maximize the measurement accuracy. The pressure gage's analog outputs are digitized by the process controller and transmitted to the main computer for Mach number computation. An automatic two-point on-line calibration of the nine quartz gages is provided using a high accuracy mercury manometer.

Kern, F. A.↗

Photometric Calibration of Consumer Video Cameras

Equipment and techniques have been developed to implement a method of photometric calibration of consumer video cameras for imaging of objects that are sufficiently narrow or sufficiently distant to be optically equivalent to point or line sources. Heretofore, it has been difficult to calibrate consumer video cameras, especially in cases of image saturation, because they exhibit nonlinear responses with dynamic ranges much smaller than those of scientific-grade video cameras. The present method not only takes this difficulty in stride but also makes it possible to extend effective dynamic ranges to several powers of ten beyond saturation levels. The method will likely be primarily useful in astronomical photometry. There are also potential commercial applications in medical and industrial imaging of point or line sources in the presence of saturation.This development was prompted by the need to measure brightnesses of debris in amateur video images of the breakup of the Space Shuttle Columbia. The purpose of these measurements is to use the brightness values to estimate relative masses of debris objects. In most of the images, the brightness of the main body of Columbia was found to exceed the dynamic ranges of the cameras. A similar problem arose a few years ago in the analysis of video images of Leonid meteors. The present method is a refined version of the calibration method developed to solve the Leonid calibration problem. In this method, one performs an endto- end calibration of the entire imaging system, including not only the imaging optics and imaging photodetector array but also analog tape recording and playback equipment (if used) and any frame grabber or other analog-to-digital converter (if used). To automatically incorporate the effects of nonlinearity and any other distortions into the calibration, the calibration images are processed in precisely the same manner as are the images of meteors, space-shuttle debris, or other objects that one seeks to analyze. The light source used to generate the calibration images is an artificial variable star comprising a Newtonian collimator illuminated by a light source modulated by a rotating variable neutral- density filter. This source acts as a point source, the brightness of which varies at a known rate. A video camera to be calibrated is aimed at this source. Fixed neutral-density filters are inserted in or removed from the light path as needed to make the video image of the source appear to fluctuate between dark and saturated bright. The resulting video-image data are analyzed by use of custom software that determines the integrated signal in each video frame and determines the system response curve (measured output signal versus input brightness). These determinations constitute the calibration, which is thereafter used in automatic, frame-by-frame processing of the data from the video images to be analyzed.

Suggs, Robert↗

A turbojet simulator for Mach numbers up to 2.0

A turbojet simulator was designed and fabricated for use in wind tunnel models. The simulator contains a six-stage, axial-flow compressor powered by a three-stage, axial-flow turbine. High pressure heated air was used to drive the turbine. At design conditions, compressor axial flow, turbine exit flow, and a third supplementary flow all entered the exhaust nozzle at equal values of pressure and termperature. Overall aerodynamic design, compressor operating conditions, automatic controls, turbine aerodynamic design, instrumentation, and calibration procedure is presented. Performance of the device when used to simulate a J-85 turbojet engine at transonic speeds is reported. The installed nozzle performance obtained with the simulator is also discussed and compared with flight data.

Steffen, F. W.↗

Digital tape drive monitor

Network checks skew and character spacing of digital tape drive systems automatically. Tape drive is set up and calibrated to check any written tape when tape is read back. It will indicate track errors or character spacing errors should they exceed specifications.

Mckenna, R. T.↗

Air-consumption parameters for automatic mixture control of aircraft engines

Data obtained from Navy calibration tests of an 18-cylinder, two-row, radial engine of 3350-cubic-inch displacement and a 14-cylinder, two-row, radial engine of 2600-cubic-inch displacement (carburetor types) were analyzed to show the correlation between the air consumption of these engines and the parameters that evaluate the air consumption from intake-manifold temperature and pressure, exhaust back pressure, and engine speed.

Shames, Sidney J↗

Self-calibrating models for dynamic monitoring and diagnosis

A method for automatically building qualitative and semi-quantitative models of dynamic systems, and using them for monitoring and fault diagnosis, is developed and demonstrated. The qualitative approach and semi-quantitative method are applied to monitoring observation streams, and to design of non-linear control systems.

Kuipers, Benjamin↗

Automated Camera Array Fine Calibration

Using aerial imagery, the JPL FineCalibration (JPL FineCal) software automatically tunes a set of existing CAHVOR camera models for an array of cameras. The software finds matching features in the overlap region between images from adjacent cameras, and uses these features to refine the camera models. It is not necessary to take special imagery of a known target and no surveying is required. JPL FineCal was developed for use with an aerial, persistent surveillance platform.

Clouse, Daniel↗

Venus radar mapping from the Venera 15 and 16 spacecrafts: Results and restrictions

A description of the results of the Venus northern hemisphere radar survey in 1983-1984 from the Venera 15 and 16 spacecrafts is presented. In addition, we discuss some peculiarities in the function of the radar equipment that defined the technology of SAR data processing. Among these peculiarities are insufficient calibration of SAR and radar altimeter and erroneous automatic gain control data transmission from the spacecrafts. As a result, the procedure of image synthesis and mosaicking contained multistage image brightness corrections. This led to the fact that the average image brightness in a spot 100 km in diameter was constant everywhere in the mosaics. Twenty-seven radar mosaics in the Lambert-Hauss conic projection with 1-2 km spatial resolution covering 25 percent of the surface of Venus have been produced. A Venus surface roughness map was constructed by joint processing of SAR and altimeter data. The mutual calibration of the SAR and altimeter was made in the special radar session when the SAR and altimeter were declined from the local vertical at the same angle. The possibility of estimating relative variations in surface reflection properties over a tens-of-kilometers interval from Venera images is still being considered. Joint analysis of the coordinates of small features of the Venera and Magellan images is one more approach being used to refine the period of rotation for Venus.

Akim, E. L.↗

A hybrid calibration approach to Hertz-type contact parameters for discrete element models

This study aims at providing a hybrid calibration framework to estimate Hertz-type contact parameters (particle-scale shear modulus and Poisson ratio) for both two-dimensional and three-dimensional discrete element modelling (DEM). On the basis of statistically isotropic granular packings, a set of analytical formulae between macroscopic material parameters (Young modulus and Poisson ratio) and particle-scale Hertz-type contact parameters for granular systems are derived under small-strain isotropic stress conditions. However, the derived analytical solutions are only estimated values for general models. By viewing each DEM modelling as an implicit mathematical function taking the particle-level parameters as independent variables and employing the derived analytical solutions as the initial input parameters, an automatic iterative scheme is proposed to obtain the calibrated parameters with higher accuracies. Considering highly nonlinear features and discontinuities of the macro-micro relationship in Hertz-based discrete element models, the adaptive moment estimation algorithm is adopted in this study because of its capacity of dealing with noise gradients of cost functions. Here, the proposed method is validated with several numerical cases including randomly distributed monodisperse and polydisperse packings. Noticeable improvements in terms of calibration efficiency and accuracy have been made.

Constitutive law↗

Vexcel Imaging's Suitability for Automatic Verification

Accurate, independently verified geospatial data is essential for automated calibration, validation, and operational decision-making. This study evaluated the positional accuracy of Vexcel Imaging™’s UltraCam® Osprey imagery (7.5 cm GSD) using globally distributed Continuously Operating Reference Stations (CORS) as independent control. Despite manufacturer claims of 15 cm horizontal accuracy, residual errors were consistently one to two orders of magnitude larger, with no subset of imagery meeting precision thresholds. These discrepancies cannot be explained by normal photogrammetric or environmental factors and raise concerns about the reliability of the imagery for high-precision tasks. The results demonstrate that Vexcel imagery, in its current form, is unsuitable for workflows requiring rigorous spatial accuracy or automated verification. At the same time, the reproducible validation framework developed in this study establishes a scalable method for assessing commercial imagery, ensuring that future products can be independently and objectively verified before operational adoption.

47 OTHER INSTRUMENTATION↗