Search NASA⌕ Search

SEARCH · Search NASA

Results for “automatic calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Bay of Fundy verification of a system for multidate Landsat measurement of suspended sediment

A system for automated multidate Landsat CCT MSS measurement of suspended sediment concentration (S) has been implemented and verified on nine sets (108 points) of data from the Bay of Fundy, Canada. The system employs 'chromaticity analysis' to provide automatic pixel-by-pixel adjustment of atmospheric variations, permitting reference calibration data from one or several dates to be spatially and temporally extrapolated to other regions and to other dates. For verification, each data set was used in turn as test data against the remainder as a calibration set: the average absolute error was 44 percent of S over the range 1-1000 mg/l. The system can be used to measure chlorophyll (in the absence of atmospheric variations), Secchi disk depth, and turbidity.

Munday, J. C., Jr.↗

Source Term Model for an Array of Vortex Generator Vanes

A source term model was developed for numerical simulations of an array of vortex generators. The source term models the side force created by a vortex generator being modeled. The model is obtained by introducing a side force to the momentum and energy equations that can adjust its strength automatically based on a local flow. The model was tested and calibrated by comparing data from numerical simulations and experiments of a single low-profile vortex generator vane, which is only a fraction of the boundary layer thickness, over a flat plate. The source term model allowed a grid reduction of about seventy percent when compared with the numerical simulations performed on a fully gridded vortex generator without adversely affecting the development and capture of the vortex created. The source term model was able to predict the shape and size of the stream wise vorticity and velocity contours very well when compared with both numerical simulations and experimental data.

Buning, P. G.↗

Source Term Model for Vortex Generator Vanes in a Navier-Stokes Computer Code

A source term model for an array of vortex generators was implemented into a non-proprietary Navier-Stokes computer code, OVERFLOW. The source term models the side force created by a vortex generator vane. The model is obtained by introducing a side force to the momentum and energy equations that can adjust its strength automatically based on the local flow. The model was tested and calibrated by comparing data from numerical simulations and experiments of a single low profile vortex generator vane on a flat plate. In addition, the model was compared to experimental data of an S-duct with 22 co-rotating, low profile vortex generators. The source term model allowed a grid reduction of about seventy percent when compared with the numerical simulations performed on a fully gridded vortex generator on a flat plate without adversely affecting the development and capture of the vortex created. The source term model was able to predict the shape and size of the stream-wise vorticity and velocity contours very well when compared with both numerical simulations and experimental data. The peak vorticity and its location were also predicted very well when compared to numerical simulations and experimental data. The circulation predicted by the source term model matches the prediction of the numerical simulation. The source term model predicted the engine fan face distortion and total pressure recovery of the S-duct with 22 co-rotating vortex generators very well. The source term model allows a researcher to quickly investigate different locations of individual or a row of vortex generators. The researcher is able to conduct a preliminary investigation with minimal grid generation and computational time.

Waithe, Kenrick A.↗

NASA's Lunar Impact Monitoring Program

NASA's Meteoroid Environment Office nas implemented a program to monitor the Moon for meteoroid impacts from the Marshall Space Flight Center. Using off-the-shelf telescopes and video equipment, the moon is monitored for as many as 10 nights per month, depending on weather. Custom software automatically detects flashes which are confirmed by a second telescope, photometrically calibrated using background stars, and published on a website for correlation with other observations, Hypervelocity impact tests at the Ames Vertical Gun Facility have been performed to determine the luminous efficiency ana ejecta characteristics. The purpose of this research is to define the impact ejecta environment for use by lunar spacecraft designers of the Constellation (manned lunar) Program. The observational techniques and preliminary results will be discussed.

Suggs, Robert M.↗

A modular solid state detector for measuring high energy heavy ion fragmentation near the beam axis

A multi-element solid state detector has been designed to measure fluences of fragments produced near the beam axis by high energy heavy ion beams in thick targets. The detector is compact and modular, so as to be readily reconfigured according to the range of fragment charges and energies to be measured. Preamplifier gain settings and detector calibrations are adjustable remotely under computer control. We describe the central detector, its associated detectors and electronics, triggering scheme, data acquisition and particle identification techniques, illustrated by data taken with 600 MeV/u 56Fe beams and thick polyethylene targets at the LBL Bevalac. The applications of this work to space radiation protection are discussed.

NASA Center HQS↗

Robot tracking system improvements and visual calibration of orbiter position for radiator inspection

The following separate topics are addressed: (1) improving a robotic tracking system; and (2) providing insights into orbiter position calibration for radiator inspection. The objective of the tracking system project was to provide the capability to track moving targets more accurately by adjusting parameters in the control system and implementing a predictive algorithm. A computer model was developed to emulate the tracking system. Using this model as a test bed, a self-tuning algorithm was developed to tune the system gains. The model yielded important findings concerning factors that affect the gains. The self-tuning algorithms will provide the concepts to write a program to automatically tune the gains in the real system. The section concerning orbiter position calibration provides a comparison to previous work that had been performed for plant growth. It provided the conceptualized routines required to visually determine the orbiter position and orientation. Furthermore, it identified the types of information which are required to flow between the robot controller and the vision system.

Tonkay, Gregory↗

Model Calibration in Watershed Hydrology

Hydrologic models use relatively simple mathematical equations to conceptualize and aggregate the complex, spatially distributed, and highly interrelated water, energy, and vegetation processes in a watershed. A consequence of process aggregation is that the model parameters often do not represent directly measurable entities and must, therefore, be estimated using measurements of the system inputs and outputs. During this process, known as model calibration, the parameters are adjusted so that the behavior of the model approximates, as closely and consistently as possible, the observed response of the hydrologic system over some historical period of time. This Chapter reviews the current state-of-the-art of model calibration in watershed hydrology with special emphasis on our own contributions in the last few decades. We discuss the historical background that has led to current perspectives, and review different approaches for manual and automatic single- and multi-objective parameter estimation. In particular, we highlight the recent developments in the calibration of distributed hydrologic models using parameter dimensionality reduction sampling, parameter regularization and parallel computing.

Yilmaz, Koray K.↗

Calibration Results for J-ERS-1 SAR Data Produced by the Alaska SAR Facility

The Alaska SAR Facility has been receiving and processing SAR data from the J-ERS-1 satellite since Spring 1992. Corner reflectors have been set up for J-ERS-1 SAR calibration at a site near Delta Junction, in central Alaska. Image quality and calibration analysis results from the Delta Junction site and others will be presented in this paper. The impact of the 3-bit Analog-to-Digital Converter and the automatic stepping of the gain as a function of range in the J-ERS-1 radar receiver on calibration performance has been assessed. Preliminary observations on J-ERS-1 SAR data are that the average Signal-to-Noise ratio is generally fairly low, in the range 5-6dB. Azimuth ambiguity levels are higher than preflight analysis indicated. Over land, the dynamic range in the backscatter at L-band for approximately 36 degree incidence angle is often fairly high.

Freeman, A.↗

Calibration Results for J-ERS-1 SAR Data Produced by the Alaska SAR Facility

The Alaska SAR Facility has been receiving and processing SAR data from the J-ERS-1 satellite since Spring 1992. Corner reflectors have been set up for J-ERS-1 SAR calibration at a site near Delta Junction, in central Alaska. Image quality and calibration analysis results from the Delta Junction site and others will be presented in this paper. The impact of the 3-bit Analog-to-Digital Converter and the automatic stepping of the gain as a function of range in the J-ERS-1 radar receiver on calibration performance has been assessed. Preliminary observations on J-ERS-1 SAR data are that the average Signal-to-Noise ratio is generally fairly low, in the range 5-6 dB. Azimuth ambiguity levels are higher than preflight analysis indicated. Over land, the dynamic range in the backscatter at L-band for approximately 36 degree incidence angle is often fairly high...

Freeman, A.↗

Analysis of scattering behavior and radar penetration in AIRSAR data

A technique is presented to physically characterize changes in radar backscatter with frequency in multifrequency single polarization radar images that can be used as a first step in the analysis of the data and the retrieval of geophysical parameters. The technique is automatic, relatively independent of the incidence angle, and only requires a good calibration accuracy between the different frequencies. The technique reveals large areas where scattering changes significantly with frequency and whether the surface has the characteristics of a smooth, slightly rough, rough, or very rough surface.

Rignot, Eric↗

Cryogenic probe station for use in automated microwave and noise figure measurements

A cryogenic measurement system capable of performing on-wafer RF testing of semiconductor devices and circuits has been developed. This 'CryoProbe Station' can wafer-probe devices and circuits at cryogenic temperatures, thus eliminating the need for wire bonds. The system operates under vacuum created by a sorption pump. It uses an open cycle cooling system that can be cooled with either liquid nitrogen or liquid helium. Presently, it can reach temperatures, as low as 80 K and 37 K for each of the coolants, respectively. The temperature can be raised using a heater and it is stabilized to within 0.2 K by use of a temperature controller. The CryoProbe Station features a 1 by 2 inch stage that can hold large circuits and calibration standards simultaneously. The system is used with a Hewlett Packard 8510C Automatic Network Analyzer (ANA) to obtain S-parameter data over the frequency range 0.045-26.5 GHz. S-parameter data on HEMT (high electron mobility transistors) devices has been obtained with this station. With the use of DEEMBED software from NIST, detailed transmission line studies have been performed. Although the CryoProbe Station is designed for frequencies up to 26.5 GHz, useful transmission line data has been obtained for frequencies as high as 40 GHz. The CryoProbe station has also been used with the ATN noise figure measurement system to perform automatic, temperature dependent noise figure measurements.

Taub, Susan R.↗

Adaptive Modeling of the International Space Station Electrical Power System

Software simulations provide NASA engineers the ability to experiment with spacecraft systems in a computer-imitated environment. Engineers currently develop software models that encapsulate spacecraft system behavior. These models can be inaccurate due to invalid assumptions, erroneous operation, or system evolution. Increasing accuracy requires manual calibration and domain-specific knowledge. This thesis presents a method for automatically learning system models without any assumptions regarding system behavior. Data stream mining techniques are applied to learn models for critical portions of the International Space Station (ISS) Electrical Power System (EPS). We also explore a knowledge fusion approach that uses traditional engineered EPS models to supplement the learned models. We observed that these engineered EPS models provide useful background knowledge to reduce predictive error spikes when confronted with making predictions in situations that are quite different from the training scenarios used when learning the model. Evaluations using ISS sensor data and existing EPS models demonstrate the success of the adaptive approach. Our experimental results show that adaptive modeling provides reductions in model error anywhere from 80% to 96% over these existing models. Final discussions include impending use of adaptive modeling technology for ISS mission operations and the need for adaptive modeling in future NASA lunar and Martian exploration.

Thomas, Justin Ray↗

Cross-Calibration of GNC and OLA LIDAR Systems Onboard OSIRIS-REx

The Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer (OSIRIS-REx) mission carried two distinct light detection and ranging (LIDAR) systems: A scanning LIDAR called OSIRIS-REx Laser Altimeter (OLA) as part of the science payload, and a flash LIDAR system has part of the Guidance, Navigation, & Control (GNC) subsystem to serve as a navigation sensor during TAG. This presents a unique opportunity to compare the performance of the two LIDAR systems in close proximity to a small asteroid body. During the Orbital B mission phase, between June to August 2019, the OSIRIS-REx spacecraft orbited Bennu in a near-circular terminator orbit during which the altitude above the surface varied between 645 m to 740 m. Over five-week period observations were recorded with the OLA instrument that were subsequently used to construct a global digital terrain map (DTM) with a resolution of 5 cm and accuracy of ±20 cm. This model provides an excellent reference for assessing the performance of the GNC LIDAR system. Two different GNC LIDAR checkout activities were also conducted during the Orbital B phase: A limb-crossing check-out featured a series of slews to collect GNC LIDAR data across varying ranges and phase angles and operate the automatic gain control modes of the device; An OLA-GNC LIDAR cross calibration was designed to collect data from both the OLA and GNC LIDAR devices with overlapping footprints while the spacecraft was pointed nadir. This paper compares the on-orbit performance observed during the cross-calibration activity. The OLA-based global DTM and point clouds are used to evaluate the GNC LIDAR not available during previous analysis. The GNC LIDAR measurements were found to be well within accuracy and precision specified for the instrument, but much noisier than the measurements from OLA within this operating regime.

Jason M Leonard↗

Tracking Retreat of the North Seasonal Ice Cap on Mars: Results from the THEMIS Investigation

The CO2 ice caps on Mars advance and retreat with the seasons. This phenomenon was first observed by Cassini and then confirmed by numerous ground based observations in 19th and 20th centuries. With the advent of the space age observations of the seasonal ice cap were done by all orbiting spacecraft starting with Mariner 7. Viking Orbiters and more recently the Mars Global Surveyor (particularly Mars Orbiter Camera (MOC) and Thermal Emission Spectrometer (TES) instruments) have accumulated significant data on the retreat of the CO2 seasonal cap. During Mars year 2 of THEMIS operations at Mars, we planned an observational campaign in which the THEMIS instrument (onboard the Mars Odyssey spacecraft) repeatedly observed the north seasonal polar cap from midwinter to late spring. THEMIS allows simultaneous observations in both Thermal IR (12.57 m) and Visible wavelengths (0.65 m). One of the goals for this work is to initiate an interannual program for observations of the seasonal ice caps using the THEMIS instrument. The most efficient way to detect the edge between frost and bare ground is directly onboard of the spacecraft. Prior to onboard software design effort, we have developed two groundbased algorithms for automatically finding the edge of the seasonal polar cap in THEMIS IR data. The first algorithm relies on fully calibrated data and can be used for highly reliable groundbased analyses. The second method was specifically developed for processing raw, uncalibrated data in a highly efficient way. It has the potential to enable automatic, onboard detections of the seasonal cap retreat. We have experimentally confirmed that both methods produce similar results, and we have validated both methods against a model constructed from the MGS TES data from the same season.

Ivanov, A. B.↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

Self-calibrating models for dynamic monitoring and diagnosis

The present goal in qualitative reasoning is to develop methods for automatically building qualitative and semiquantitative models of dynamic systems and to use them for monitoring and fault diagnosis. The qualitative approach to modeling provides a guarantee of coverage while our semiquantitative methods support convergence toward a numerical model as observations are accumulated. We have developed and applied methods for automatic creation of qualitative models, developed two methods for obtaining tractable results on problems that were previously intractable for qualitative simulation, and developed more powerful methods for learning semiquantitative models from observations and deriving semiquantitative predictions from them. With these advances, qualitative reasoning comes significantly closer to realizing its aims as a practical engineering method.

Kuipers, Benjamin↗

Design and analysis of an automatic method of measuring silicon-controlled-rectifier holding current

The design of an automated SCR holding-current measurement system is described. The circuits used in the measurement system were designed to meet the major requirements of automatic data acquisition, reliability, and repeatability. Performance data are presented and compared with calibration data. The data verified the accuracy of the measurement system. Data taken over a 48-hr period showed that the measurement system operated satisfactorily and met all the design requirements.

Maslowski, E. A.↗

On The Processing of Log Files for Monitoring Antenna Health

In order to improve the quality of geodetic results, we have developed an infrastructure for timely processing of telemetry from IVS observing stations. We check every hour for new log files with telemetry from both VLBI observing sessions, single dish experiments, and stow-in data collection and automatically process them. The telemetry data we use is the system temperature, phase calibration phases and amplitudes, system equivalent flux density, and the differences between formatter clock and GPS clock. For the system temperature and phase calibration, processing includes filtering out outliers and computing averages and rms of the scatter in each scan. Furthermore, for the phase calibration we also compute the group delay and detect spurious signals. Cleaned and post-processed telemetry is archived. Our process detects abnormalities, such as, anomalously high system temperature, unstable phase calibration phases, jumps in the GPS and formatter clock differences, and others. With our procedure, the latency of detection of station abnormalities is reduced to less than two hours. Early detection of abnormalities reduces the amount of affected data since station personnel get early alerts. We discuss our experience of running this system since 2022.

Phase Calibration↗