At least 145 records · Page 8

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Solar Radiation Research Laboratory (SRRL) Core Project Final Report: Fiscal Years 2022-2024

The Solar Radiation Research Laboratory (SRRL) at the National Laboratory of the Rockies (NLR) is a world-leading solar calibration and measurement facility and maintains and disseminates the World Radiation Reference (essentially the W/m2) for the United States that is essential for traceable and accurate measurements of solar radiation at all solar generation facilities. SRRL operates two calibration facilities that meet International Standards Organization-17025 (ISO-17025) standards and provide unique high-quality calibrations to NREL and other U.S. Department of Energy laboratories. The Baseline Measurement System (BMS) at SRRL provides a high-quality record of solar irradiance and surface meteorological conditions. SRRL capabilities are used to develop (1) improved methods for the calibration of solar radiometers; (2) new standards through the ISO, the International Electrotechnical Commission (IEC), and the American Standards for Testing of Materials (ASTM) International; (c) solar radiation and meteorological models; and (d) advanced instrumentation and methods for operating solar measurement stations. The SRRL datasets are also critical for the validation of new models and datasets, such as the National Solar Radiation Database (NSRDB). The research and development of solar radiation measurement systems and resource modeling techniques are essential for advancing the scientific basis for producing reliable resource data. Specifically, the spatial, temporal, and spectral (wavelength dependency) characteristics of the solar resource are required in several different time frames for various project phases.

14 SOLAR ENERGY↗

Preradiotherapy Calcium Scores of the Coronary Arteries in a Cohort of Women With Early-Stage Breast Cancer: A Comparison With a Cohort of Healthy Women

Purpose: Breast cancer radiotherapy has been associated with an increased risk of cardiac toxicity. However, no data are available on the probability of developing coronary artery disease (CAD) in breast cancer patients when compared with healthy women. Therefore, baseline coronary artery calcium (CAC) scores, as an accepted tool to predict CAD, were determined and compared with the CAC scores of a healthy, asymptomatic cohort, the Multi-Ethnic Study of Atherosclerosis (MESA) cohort. Methods and Materials: Eighty consecutive patients with ductal carcinoma in situ or infiltrative breast cancer referred for radiotherapy after breast-conserving surgery were included in our study. Their cardiovascular risk profile was registered, and a 64 multislice CT scan was performed. The CAC scores of an unselected (Caucasian only) Radiotherapy Centre West (RCWEST) cohort, as well as of those of a selected (comorbidity and race adjusted) RCWEST cohort, were determined. The scores of both cohorts were compared with those of the female (Caucasian only) MESA cohort. Results: For the unselected RCWEST cohort (n = 62) we found significant (p < .01) higher scores for women in the 55-64 age category compared with those of the MESA cohort. In the selected cohort (n = 55) the CAC scores of the women in the age category 55-64 were significantly (p = .02) higher compared with the MESA cohort. No significant differences were noted in the other age categories. Conclusion: Both cohorts revealed that CAC scores in the 55-64 age category were significantly higher than the CAC scores in the asymptomatic (female) MESA population. These data suggest that breast cancer patients bear a higher risk of developing coronary heart disease before the start of radiotherapy. Therefore, measures to decrease cardiac dose further in breast cancer radiotherapy are even more important.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pancreaticoportal Fistula and Disseminated Fat Necrosis After Revision of a Transjugular Intrahepatic Portosystemic Shunt

A 59-year old man with alcohol related cirrhosis and portal hypertension was referred for transjugular intrahepatic portosystemic shunt (TIPS) to treat his refractory ascites. Ten years later, two sequential TIPS revisions were performed for shunt stenosis and recurrent ascites. After these revisions, he returned with increased serum pancreatic enzyme levels and disseminated superficial fat necrosis; an iatrogenic pancreaticoportal vein fistula caused by disruption of the pancreatic duct was suspected. The bare area of the TIPS was subsequently lined with a covered stent-graft, and serum enzyme levels returned to baseline. In the interval follow-up period, the patient has clinically improved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association Between Anticholinergic Medication Use and Cognition, Brain Metabolism, and Brain Atrophy in Cognitively Normal Older Adults

Importance of this Paper: The use of anticholinergic (AC) medication is linked to cognitive impairment and an increased risk of dementia. To our knowledge, this is the first study to investigate the association between AC medication use and neuroimaging biomarkers of brain metabolism and atrophy as a proxy for understanding the underlying biology of the clinical effects of AC medications. Objective: To assess the association between AC medication use and cognition, glucose metabolism, and brain atrophy in cognitively normal older adults from the Alzheimer’s Disease Neuroimaging Initiative (ADNI) and the Indiana Memory and Aging Study (IMAS). Design, Setting, and Participants: The ADNI and IMAS are longitudinal studies with cognitive, neuroimaging, and other data collected at regular intervals in clinical and academic research settings. For the participants in the ADNI, visits are repeated 3, 6, and 12 months after the baseline visit and then annually. For the participants in the IMAS, visits are repeated every 18 months after the baseline visit (402 cognitively normal older adults in the ADNI and 49 cognitively normal older adults in the IMAS were included in the present analysis). Participants were either taking (hereafter referred to as the AC + participants [52 from the ADNI and 8 from the IMAS]) or not taking (hereafter referred to as the AC - participants [350 from the ADNI and 41 from the IMAS]) at least 1 medication with medium or high AC activity. Data analysis for this study was performed in November 2015. Main Outcomes and Measures: Cognitive scores, mean fludeoxyglucose F 18 standardized uptake value ratio (participants from the ADNI only), and brain atrophy measures from structural magnetic resonance imaging were compared between AC + participants and AC - participants after adjusting for potential confounders. The total AC burden score was calculated and was related to target measures. The association of AC use and longitudinal clinical decline (mean [SD] follow-up period, 32.1 [24.7] months [range, 6-108 months]) was examined using Cox regression. Results: The 52 AC + participants (mean [SD] age, 73.3 [6.6] years) from the ADNI showed lower mean scores on Weschler Memory Scale–Revised Logical Memory Immediate Recall (raw mean scores: 13.27 for AC + participants and 14.16 for AC - participants; P = .04) and the Trail Making Test Part B (raw mean scores: 97.85 seconds for AC + participants and 82.61 seconds for AC - participants; P = .04) and a lower executive function composite score (raw mean scores: 0.58 for AC + participants and 0.78 for AC - participants; P = .04) than the 350 AC - participants (mean [SD] age, 73.3 [5.8] years) from the ADNI. Reduced total cortical volume and temporal lobe cortical thickness and greater lateral ventricle and inferior lateral ventricle volumes were seen in the AC + participants relative to the AC - participants. Conclusions and Relevance of this Paper: The use of AC medication was associated with increased brain atrophy and dysfunction and clinical decline. Thus and finally, use of AC medication among older adults should likely be discouraged if alternative therapies are available.

60 APPLIED LIFE SCIENCES↗

In-Situ FTIR Detection of Transition Metal (TM)-Ion Dissolution From Cathodes in Li-Ion Batteries

Transition metal (TM) ions, commonly Ni and Mn, play a crucial role in Li-ion battery cathodes as the reaction centers for rapid redox reactions. A major challenge with TM-based cathodes is capacity degradation, particularly at higher operating voltages. This degradation is closely linked to the dissolution of TMs from the cathode materials and their subsequent deposition on the anode. This process not only modifies the surface structure of the cathode but, more significantly, alters the SEI composition on the anode [1-2]. The dissolution of TMs cations into a liquid electrolyte from cathode materials, such as Mn-ion dissolution from Mn-rich cathode (LMR), is detrimental to the cycling performance of Li-ion batteries [3-4]. Much attention has been paid to this issue but there remains a lack of characterization techniques which can detect the TM-ion dissolution from the cathode during electrochemical measurements. In our study, we use in-situ ATR-FTIR as an effective technique to probe the TM-ion dissolution from the cathode. We have first demonstrated the detrimental effects of TM ions on the electrochemical performance of Li-ion batteries by adding a small amount of TM salt (50 mM Mn(PF6)) to the electrolyte of a Li-ion coin cell with LFP and graphite electrode. We observed a rapid capacity fade after the first delithiation cycle. To investigate TM ion dissolution, we established a baseline IR spectrum for various TM solvation states (such as Mn and Ni) by measuring concentration-dependent IR spectra. This baseline spectrum helps us detect TM ion dissolution during battery cycling. In this work, we discuss in detail the effect of TM ions on the electrochemical performance of Li-ion batteries and the detection of TM ions during battery cycling using in-situ FTIR spectroscopy. We will compare TM dissolution between coated and uncoated cathodes to examine the effect of cathode coatings to mitigate degradation due to TM dissolution and cross-over from cathode to anode. References: (1) Zhan, C.; Wu, T.; Lu, J.; Amine, K. Dissolution, migration, anddeposition of transition metal ions in Li-ion batteries exemplified byMn-based cathodes - a critical review. Energy Environ. Sci. 2018, 11,243-257. (2) Jung, R.; Linsenmann, F.; Thomas, R.; Wandt, J.; Solchenbach,S.; Maglia, F.; Stinner, C.; Tromp, M.; Gasteiger, H. A. Nickel,Manganese, and Cobalt Dissolution from Ni-Rich NMC and TheirEffects on NMC622-Graphite Cells. J. Electrochem. Soc. 2019, 166,A378-A389. (3) Zhao, L.; Chenard, E.; Capraz, O. O.; Sottos, N. R.; White, S.R. Direct Detection of Manganese Ions in Organic Electrolyte by UV-Vis Spectroscopy. J. Electrochem. Soc. 2018, 165, A345-A348 (4) Zhang, Y.; Hu, A.; Xia, D.; Hwang, S.; Sainio, S.; Nordlund, D.;Michel, F. M.; Moore, R. B.; Li, L.; Lin, F. Operando characterization and regulation of metal dissolution and redeposition dynamics nearbattery electrode surface. Nat. Nanotechnol. 2023, 18, 790.

25 ENERGY STORAGE↗

Reference Model 5 (RM5): Oscillating Surge Wave Energy Converter

This report is an addendum to SAND2013-9040: Methodology for Design and Economic Analysis of Marine Energy Conversion (MEC) Technologies. This report describes an Oscillating Water Column Wave Energy Converter (OSWEC) reference model design in a complementary manner to Reference Models 1-4 contained in the above report. A conceptual design for a taut moored oscillating surge wave energy converter was developed. The design had an annual electrical power of 108 kilowatts (kW), rated power of 360 kW, and intended deployment at water depths between 50 m and 100 m. The study includes structural analysis, power output estimation, a hydraulic power conversion chain system, and mooring designs. The results were used to estimate device capital cost and annual operation and maintenance costs. The device performance and costs were used for the economic analysis, following the methodology presented in SAND2013-9040 that included costs for designing, manufacturing, deploying, and operating commercial-scale MEC arrays up to 100 devices. The levelized cost of energy estimated for the Reference Model 5 OSWEC, presented in this report, was for a single device and arrays of 10, 50, and 100 units, and it enabled the economic analysis to account for cost reductions associated with economies of scale. The baseline commercial levelized cost of energy estimate for the Reference Model 5 device in an array comprised of 10 units is $1.44/kilowatt-hour (kWh), and the value drops to approximately $0.69/kWh for an array of 100 units.

16 TIDAL AND WAVE POWER↗

Aluminophosphate Waste Forms for Immobilizing Cations from Electrochemical Salt Wastes

This report provides experimental details and results of evaluating aluminophosphate waste forms for treating and immobilizing the salt cations from salt wastes generated during electrochemical reprocessing of used nuclear fuel. In the waste form process for these materials, chloride salt streams are reacted with NH 4 H 2 PO 4 , the chlorine is removed from the salts and driven off as NH 4 Cl (a solid condensate that can be captured), and then the product can be vitrified in conjunction with glass-forming chemicals (e.g., Fe 2 O 3 , Al 2 O 3 ) to create a high-durability waste form. This study was initiated with some literature review on aluminophosphates containing high alkali oxide content and some of this information is summarized in this report. Following literature review, three new samples were synthesized where two contained Fe 2 O 3 +Al 2 O 3 (i.e., samples G3 and G5 ) and one was only Al 2 O 3 (Fe 2 O 3 -free) (i.e., sample G6 ). In addition to these samples, G1 was also made, which is the baseline reference waste form referred to as DPF5-336 (made without Al 2 O 3 ). Samples G1, G3, G5, and G6 had phases of Li 3 Fe 2 (PO 4 ) 3 (likely), monazite (below XRD detection limits), AlPO 4 , and AlPO 4 , respectively. Characterizations on these materials included optical images, scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction. These samples were shipped to Argonne National Laboratory for chemical durability testing. Depending on how the samples perform in these tests, an additional phase of aluminophosphate formulations could be designed and tested. This report completes the milestone M4FT-23PN030104041 with details provided in Appendix B.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Insight to the Duration of 120 °C Baking on the Performance of SRF Niobium Cavities

Low-temperature baking at 100 °C - 140 °C in ultra-high vacuum for several hours is the final cavity processing technique to achieve the highest accelerating gradient cavity by eliminating the high field Q-slope, typically on cavities made of high purity fine grain niobium and subjected to electropolishing. The temperature and duration of baking control the onset of the high field Q-slope and overall quality factor over the baseline measurements. The increase in quality factor is generally related to the reduction in the temperature-dependent surface resistance, which refers to BCS surface resistance due to the reduction in the electronic mean free path and elimination of high field Q-slope is still being actively investigated. Here, we present the results of a series of measurements on 1.3 GHz TESLA shape single-cell cavities with successive low-temperature baking at 120 °C up to 96 hours. The rf loss related to the trapping of residual magnetic field refer to flux trapping sensitivity was measured with respect to the duration of 120 °C bake.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Update to the NREL Baseline Wind Turbine Controller: Preprint

The NREL 5MW wind turbine model is well established as an industry standard and is often used as a comparison model, or a model on which to build upon. Though effective, the legacy controller for the NREL 5MW wind turbine is built on a simple algorithm that is not up to date with many industry standards. Additionally, as the research community has advanced into more fast-paced development cycles, as systems engineering tools such as WISDEM \cite{WISDEM} are employed, and as a greater focus on controls co-design practices is encouraged, a demand for a generic wind turbine controller has arisen. This work presents updates for the NREL 5MW baseline controller to a more modern control architecture, and establishes a generic tuning framework that can be easily adapted to various wind turbines. Based on initial results, the updated generic controller eases the automatic tuning process, while maintaining or improving upon the performance of the legacy NREL 5MW controller.

17 WIND ENERGY↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

THE IMPACT OF FREQUENCY STANDARDS ON COHERENCE IN VLBI AT THE HIGHEST FREQUENCIES

We have carried out full imaging simulation studies to explore the impact of frequency standards in millimeter and submillimeter very long baseline interferometry (VLBI), focusing on the coherence time and sensitivity. In particular, we compare the performance of the H-maser, traditionally used in VLBI, to that of ultra-stable cryocooled sapphire oscillators over a range of observing frequencies, weather conditions, and analysis strategies. Our simulations show that at the highest frequencies, the losses induced by H-maser instabilities are comparable to those from high-quality tropospheric conditions. We find significant benefits in replacing H-masers with cryocooled sapphire oscillator based frequency references in VLBI observations at frequencies above 175 GHz in sites which have the best weather conditions; at 350 GHz we estimate a 20%-40% increase in sensitivity over that obtained when the sites have H-masers, for coherence losses of 20%-10%, respectively. Maximum benefits are to be expected by using co-located Water Vapor Radiometers for atmospheric correction. In this case, we estimate a 60%-120% increase in sensitivity over the H-maser at 350 GHz.

74 ATOMIC AND MOLECULAR PHYSICS↗

Blade and Rim Seal Design of a First Stage High Pressure Turbine for a 300 MWe Supercritical CO2 Power Cycle

A first stage high-pressure turbine (HPT) blade is optimized for a 300 MWe supercritical CO2 (sCO2) power cycle using the surrogate-assisted genetic algorithm optimizer in Numeca FINE/Design 3D with objectives of increasing efficiency and decreasing heat load to the blade. The National Institute of Standards and Technology Reference Fluid Thermodynamic and Transport Properties Database (NIST REFPROP) [1] data for supercritical CO2 is formatted into tables of bicubic polynomial coefficients for use in condensable gas simulations in FINE/Turbo. Nearly 3000 unique shapes are evaluated via three-dimensional Reynolds Averaged Navier Stokes simulations, yielding increases in efficiency of up to 0.85 percentage points and decreases in heat load of 14%. A final blade, deemed the advanced blade, is chosen for future experimental analysis. Following this, a squealer tip optimization is performed on both the baseline and advanced blade designs. This optimization resulted in a performance gain of 1.25 points in efficiency and 15% reduction in tip heat load compared to the baseline flat tip design at the same clearance. In tandem, an optimization of the rotor-stator platform rim seal is performed using a parametrized geometry allowing for straight, meandering, and knife seal cavities. This multi-objective optimization focuses on decreasing the cooling mass flow and increasing the heat flux from the rotor and stator disk. The optimization resulted in cooling mass flow decreases of up to 26% while maintaining the average heat flux on the rim seal.

Tuite, Logan↗

Symptoms and Quality of Life in Cancer Patients With Brain Metastases Following Palliative Radiotherapy

Purpose: To examine prospectively patient self-rated symptoms and quality of life (QOL) indicators in patients with brain metastases following whole brain radiotherapy (WBRT). Methods and Materials: Consecutive patients with brain metastases referred for WBRT were approached for this study. Patients were asked to rate their symptoms and QOL using the Spitzer Quality of Life Index questionnaire. Follow-up was at 1, 2, and 3 months following WBRT. Linear regression analysis was used to determine the change in symptom severity over time. Results: Between August 2005 to October 2007, 129 patients with brain metastases were enrolled. The majority of patients (88%) received 20 Gy in five fractions. Median age was 64 years, and median Karnofsky Performance Status at baseline was 70. The most commonly experienced symptoms at baseline were headaches, weakness, balance problems, and fatigue. Thirty-five percent of patients rated neurological functional (NF) status as 1, indicating moderate neurological symptoms and need for assistance. Forty-three percent of patients had stable or decreased fatigue, and 47% had a stable or improved NF status over time (p = 0.0040). Although certain QOL domains improved over time, all other QOL domains and symptom items did not change significantly following WBRT. Conclusion: WBRT may have contributed to symptom stabilization in our study. An alternative goal of WBRT may be the prevention of symptom progression and QOL deterioration. Further research is required to select the most appropriate group of patients with brain metastases who would benefit most from WBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity

This revised report presents an independent assessment of the cost and performance of select fossil energy power systems—integrated gasification combined cycle (IGCC), pulverized coal (PC), and natural gas combined cycle (NGCC) plants—using a systematic, transparent technical and economic approach. The cost and performance of fossil fuel-based generation technologies represented in this report (and the series at large) are important inputs to assessments and determinations of technology combinations to be utilized to meet the projected demands of future power markets. In addition to informing technology comparisons, the reference plant configurations found in this report provide perspective for regulators and policy makers. From a research and development perspective, this report is used to assess goals and metrics and to provide a consistent basis for comparing developing technologies.

01 COAL, LIGNITE, AND PEAT↗

Lawrence Livermore National Laboratory Emergency Response Capability Baseline Needs Assessment Requirement Document

This revision of the LLNL Fire Protection Baseline Needs Assessment (BNA) was prepared by John A. Sharry, LLNL Fire Marshal and LLNL Division Leader for Fire Protection and reviewed by Martin Gresho, Sandia/CA Fire Marshal. The document follows and expands upon the format and contents of the DOE Model Fire Protection Baseline Capabilities Assessment document contained on the DOE Fire Protection Web Site, but only address emergency response. The original LLNL BNA was created on April 23, 1997 as a means of collecting all requirements concerning emergency response capabilities at LLNL (including response to emergencies at Sandia/CA) into one BNA document. The original BNA documented the basis for emergency response, emergency personnel staffing, and emergency response equipment over the years. The BNA has been updated and reissued five times since in 1998, 1999, 2000, 2002, and 2004. A significant format change was performed in the 2004 update of the BNA in that it was 'zero based.' Starting with the requirement documents, the 2004 BNA evaluated the requirements, and determined minimum needs without regard to previous evaluations. This 2010 update maintains the same basic format and requirements as the 2004 BNA. In this 2010 BNA, as in the previous BNA, the document has been intentionally divided into two separate documents - the needs assessment (1) and the compliance assessment (2). The needs assessment will be referred to as the BNA and the compliance assessment will be referred to as the BNA Compliance Assessment. The primary driver for separation is that the needs assessment identifies the detailed applicable regulations (primarily NFPA Standards) for emergency response capabilities based on the hazards present at LLNL and Sandia/CA and the geographical location of the facilities. The needs assessment also identifies areas where the modification of the requirements in the applicable NFPA standards is appropriate, due to the improved fire protection provided, the remote location and low population density of some the facilities. As such, the needs assessment contains equivalencies to the applicable requirements. The compliance assessment contains no such equivalencies and simply assesses the existing emergency response resources to the requirements of the BNA and can be updated as compliance changes independent of the BNA update schedule. There are numerous NFPA codes and standards and other requirements and guidance documents that address the subject of emergency response. These requirements documents are not always well coordinated and may contain duplicative or conflicting requirements or even coverage gaps. Left unaddressed, this regulatory situation results in frequent interpretation of requirements documents. Different interpretations can then lead to inconsistent implementation. This BNA addresses this situation by compiling applicable requirements from all identified sources (see Section 5) and analyzing them collectively to address conflict and overlap as applicable to the hazards presented by the LLNL and Sandia/CA sites (see Section 7). The BNA also generates requirements when needed to fill any identified gaps in regulatory coverage. Finally, the BNA produces a customized simple set of requirements, appropriate for the DOE protection goals, such as those defined in DOE O 420.1B, the hazard level, the population density, the topography, and the site layout at LLNL and Sandia/CA that will be used as the baseline requirements set - the 'baseline needs' - for emergency response at LLNL and Sandia/CA. A template approach is utilized to accomplish this evaluation for each of the nine topical areas that comprise the baseline needs for emergency response. The basis for conclusions reached in determining the baseline needs for each of the topical areas is presented in Sections 7.1 through 7.9. This BNA identifies only mandatory requirements and establishes the minimum performance criteria. The minimum performance criteria may not be the level of performance desired Lawrence Livermore National Laboratory or Sandia/CA. Performance at levels greater than those established by this document will provide a higher level of fire safety, fire protection, or loss control and is encouraged. In Section 7, Determination of Baseline Needs, a standard template was used to describe the process used that involves separating basic emergency response needs into nine separate services. Each service being evaluated contains a determination of minimum requirements, an analysis of the requirements, a statement of minimum performance, and finally a summary of the minimum performance. The requirement documents, listed in Section 5, are those laws, regulations, DOE Directives, contractual obligations, or LLNL policies that establish service levels. The determination of minimum requirements section explains the rationale or method used to determine the minimum requirements.

99 GENERAL AND MISCELLANEOUS↗

Capsule network-based semantic segmentation model for thermal anomaly identification on building envelopes

Thermography technology is widely used to inspect thermal anomalies in building façade systems. Computer vision-based techniques provide opportunities to autonomously detect such heat anomalies to significantly improve the efficiency of decision-making for building envelope retrofitting and maintenance. Here, in this work, we propose a novel Capsule Network-based deep learning model – CapsLab – that detects and identifies thermal anomalies by semantic segmentation. CapsLab is built based on our proposed prediction-tuning capsule (PT-Capsule) layer. Different from a traditional capsule layer, which consists of part-whole transformation and capsule-routing process, the proposed layer is composed of a prediction and tuning process, which helps decreasing the number of model parameters significantly. While the applicability of traditional Capsule Networks (CapsNets) has been limited to simpler tasks and smaller datasets due to their scalability issue, we can leverage the lightweight of the proposed PT-Capsule layer, and apply it to the semantic segmentation task. In this work, we also employ our previously presented performance metric, referred to as the Anomaly Identification Metric (AIM) (Kakillioglua et al. 2021), to evaluate the segmentation outputs. Traditional performance metrics do not accurately reflect the true performance of the segmentation models in thermal anomaly identification due to the high subjectivity in the annotation process and higher overlap ratio sensitivity of the standard metrics. AIM, on the other hand, is robust to these drawbacks. Experimental results show, both qualitatively and quantitatively, that our proposed segmentation method can effectively segment the thermal anomalies. Specifically, our model provides 9.38% and 13.53% improvements over the baseline model – DeepLabV3+ – based on traditional mIoU score and the AIM score, respectively, while requiring less model parameters and less computation at the same time. In addition, the scores that the AIM metric generates better align with the scores provided by building performance experts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ceramic Composite Inert Matrix Fuel Forms in High-Temperature Gas-Cooled Microreactors

Here, this work optimizes micro-prismatic high-temperature gas reactor (HTGR) designs to reduce the energy-normalized mass of spent nuclear fuel (SNF) and high-level waste (HLW) produced. The optimization was performed for the current graphite moderator and an inert matrix fuel (IMF) concept employing different composite moderators in a prismatic design architecture. The fuel matrix is magnesium oxide (MgO) with entrained tristructural-isotropic (TRISO) fuel. The moderator materials, including beryllium oxide (MgO-BeO) and beryllium (MgO-Be) at 40 vol % loading and yttrium hydride (MgO-YH x=1.9 ) and zirconium hydride (MgO-ZrH x=1.9 ) at 15 vol % loading, were entrained within the MgO host matrix. A generic graphite micro-prismatic HTGR is used as the baseline point design where the external dimensions are held constant. The composite moderator designs use 19.9% enriched uranium nitride TRISO fuel and hexagonal assemblies. For each IMF concept, an optimization study was performed to maximize the discharge burnup of the fuel by varying the TRISO packing fraction and the lattice pitch of the assemblies. The mass of SNF and HLW, other waste metrics, fuel cost, environmental impact metrics, and the activity of the SNF and HLW at 100 years and 100 000 years were calculated for the optimized IMF and graphite reference designs. The IMF results were subsequently compared to those of the graphite reference and the values for a light water reactor (LWR) and a small modular LWR. For the SNF and HLW, all the IMF concepts and the graphite reference produced less waste compared to the traditional LWR designs. However, the IMF concepts outperformed the graphite reference regarding the mass of SNF and HLW. For the other waste metrics, the IMF concepts showed reductions in fuel cost with improved environmental metrics relative to the graphite reference. Overall, the IMF concepts significantly reduced the SNF and HLW produced per unit of energy generated compared to traditional LWR designs.

TRISO↗