Improved transistor-controlled and commutated brushless DC motors for electric vehicle propulsion

The development, design, construction, and testing processes of two electronically (transistor) controlled and commutated permanent magnet brushless dc machine systems, for propulsion of electric vehicles are detailed. One machine system was designed and constructed using samarium cobalt for permanent magnets, which supply the rotor (field) excitation. Meanwhile, the other machine system was designed and constructed with strontium ferrite permanent magnets as the source of rotor (field) excitation. These machine systems were designed for continuous rated power output of 15 hp (11.2 kw), and a peak one minute rated power output of 35 hp (26.1 kw). Both power ratings are for a rated voltage of 115 volts dc, assuming a voltage drop in the source (battery) of about 5 volts. That is, an internal source voltage of 120 volts dc. Machine-power conditioner system computer-aided simulations were used extensively in the design process. These simulations relied heavily on the magnetic field analysis in these machines using the method of finite elements, as well as methods of modeling of the machine power conditioner system dynamic interaction. These simulation processes are detailed. Testing revealed that typical machine system efficiencies at 15 hp (11.2 kw) were about 88% and 84% for the samarium cobalt and strontium ferrite based machine systems, respectively. Both systems met the peak one minute rating of 35 hp.

Demerdash, N. A.↗

Design of a battery charger for the NASA EOS space platform

A battery charger design for the NASA Earth Observing System (EOS) space platform has been developed and tested. The authors discuss the design of the battery charger power state and its current and voltage control loops. In addition to restoring energy to the batteries, this charger regulates the spacecraft bus voltage during the posteclipse transition period. The battery charger design and analysis were facilitated by use of the pulse-width-modulated (PWM) switch model and the new continuous-time model for current-mode control. Analyses of the battery charger small-signal behavior are compared to hardware measurements to verify modeling accuracy.

Sizemore, Tom↗

Smart Power Supply for Battery-Powered Systems

A power supply for battery-powered systems has been designed with an embedded controller that is capable of monitoring and maintaining batteries, charging hardware, while maintaining output power. The power supply is primarily designed for rovers and other remote science and engineering vehicles, but it can be used in any battery alone, or battery and charging source applications. The supply can function autonomously, or can be connected to a host processor through a serial communications link. It can be programmed a priori or on the fly to return current and voltage readings to a host. It has two output power busses: a constant 24-V direct current nominal bus, and a programmable bus for output from approximately 24 up to approximately 50 V. The programmable bus voltage level, and its output power limit, can be changed on the fly as well. The power supply also offers options to reduce the programmable bus to 24 V when the set power limit is reached, limiting output power in the case of a system fault detected in the system. The smart power supply is based on an embedded 8051-type single-chip microcontroller. This choice was made in that a credible progression to flight (radiation hard, high reliability) can be assumed as many 8051 processors or gate arrays capable of accepting 8051-type core presently exist and will continue to do so for some time. To solve the problem of centralized control, this innovation moves an embedded microcontroller to the power supply and assigns it the task of overseeing the operation and charging of the power supply assets. This embedded processor is connected to the application central processor via a serial data link such that the central processor can request updates of various parameters within the supply, such as battery current, bus voltage, remaining power in battery estimations, etc. This supply has a direct connection to the battery bus for common (quiescent) power application. Because components from multiple vendors may have differing power needs, this supply also has a secondary power bus, which can be programmed a priori or on-the-fly to boost the primary battery voltage level from 24 to 50 V to accommodate various loads as they are brought on line. Through voltage and current monitoring, the device can also shield the charging source from overloads, keep it within safe operating modes, and can meter available power to the application and maintain safe operations.

Krasowski, Michael J.↗

Orion Power Transfer: Impacts of a Battery-on-Bus Power System Architecture

The Orion Multi-Purpose Crew Vehicle (MPCV) has the capability to transfer power to a co-manifested payload (CPL) during transit from low-Earth orbit to the lunar vicinity. This paper discusses a time-phased parametric power analysis to determine the Orion power transfer capability limit. Charge and discharge curves were generated for various power transfer conditions and measured against various minimum system voltage limits. The Orion electrical power system (EPS) utilizes an unregulated bus architecture, which has important implications when the system is operating under very high load demand conditions, such as during power transfer. This analysis highlights three important effects of this architecture. First, increasing load demand decreases the maximum state of charge (SOC) the batteries can reach when charging. Second, increasing load demand also decreases the allowable battery depth of discharge. These two together can significantly reduce the effective useable capacity of the batteries. Finally, low battery voltage decreases the power generation of the solar arrays. This can lead to significantly longer recharge times or even push the system out of energy balance. These effects have important implications for mission design and vehicle operations and must be accounted for when conducting sizing and design of an unregulated spacecraft EPS.

Electrical Power System↗

Lithium Ion Batteries

Lithium ion batteries, which use a new battery chemistry, are being developed under cooperative agreements between Lockheed Martin, Ultralife Battery, and the NASA Lewis Research Center. The unit cells are made in flat (prismatic) shapes that can be connected in series and parallel to achieve desired voltages and capacities. These batteries will soon be marketed to commercial original-equipment manufacturers and thereafter will be available for military and space use. Current NiCd batteries offer about 35 W-hr/kg compared with 110 W-hr/kg for current lithium ion batteries. Our ultimate target for these batteries is 200 W-hr/kg.

Source record↗

The characteristics of sealed nickel-cadmium cells during voltage reversal

A mechanism which allows a cell voltage reversal in a nickel cadmium battery are discussed. The effects of reconditioning and the characteristics of Ni-Cd cells during voltage reversal at low overdischarge rates are outlined. Graphs are presented for: (1) hydrogen pressure decay-effect of state of charge (open circuit stand); (2) hydrogen pressure increase during overdischarge; (3) hydrogen pressure decay-effect of temperature (cells terminals connected through resistors); (4) cell, positive and negative electrode voltage during reversal when reconditioning a 13 cell-24-Ah battery pack through a 40 Omega resistor; (5) pressure discharge current and recombination current during voltage reversal when reconditioning a 13 cell-24-Ah battery pack through a 40 Omega resistor; (6) theoretical hydrogen gas pressure if there were no recombination; and (7) effect of hydrogen pressure on recombination rate during overcharge.

Ritterman, P. F.↗

Prediction Model for the Life of Nickel-cadmium Batteries in Geosynchronous Orbit Satellites

A mathematical model is described which predicts the service life of nickel-cadmium batteries designed for geosynchronous orbit satellites. Regression analysis technique is used to analyze orbital data on second generation trickle charged batteries. The model gives average cell voltage as a function of design parameters, operating parameters and time. The voltage model has the properties of providing a good fit to the data, good predictive capability, and agreement with known battery performance characteristics. Average cell voltage can be predicted to within 0.02 volts for up to 8 years. This modeling shows that these batteries will operate reliably for 10 years. Third-generation batteries are expected to operate even longer.

Engleman, J. H.↗

Method of Detecting System Function by Measuring Frequency Response

Real time battery impedance spectrum is acquired using one time record, Compensated Synchronous Detection (CSD). This parallel method enables battery diagnostics. The excitation current to a test battery is a sum of equal amplitude sin waves of a few frequencies spread over range of interest. The time profile of this signal has duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known, synchronous detection processes the time record and each component, both magnitude and phase, is obtained. For compensation, the components, except the one of interest, are reassembled in the time domain. The resulting signal is subtracted from the original signal and the component of interest is synchronously detected. This process is repeated for each component.

Morrison, John L.↗

A method for battery activation

A technique to activate nickel cadmium batteries is described. The method shortened the time required for activation, eliminated the temperature rise in the batteries, and produced a voltage on the discharge that was better than when the C/20 was run for 48 hours during tests. Various methods of activation are described and evaluated. Results of alternate conditioning charge schemes are presented along with voltage/temperature characteristics for multiple level nickel cadmium battery chargers.

Halpert, G.↗

Analysis of Stationary, Photovoltaic-based Surface Power System Designs at the Lunar South Pole

Combinations of solar arrays and either batteries or regenerative fuel cells are analyzed for a surface power system module at the lunar south pole. The systems are required to produce 5 kW of net electrical power in sunlight and 2 kW of net electrical power during lunar night periods for a 10-year period between 2020 and 2030. Systems-level models for energy conservation, performance, degradation, and mass are used to compare to various systems. The sensitivities of important and/or uncertain variables including battery specific energy, fuel cell operating voltage, and DC-DC converter efficiency are compared to better understand the system. Switching unit efficiency, battery specific energy, and fuel cell operating voltage appear to be important system-level variables for this system. With reasonably sized solar arrays, the regenerative fuel cell system has significantly lower mass than the battery system based on the requirements and assumptions made herein. The total operational time is estimated at about 10,000 hours in battery discharge/fuel cell mode and about 4,000 and 8,000 hours for the battery charge and electrolyzer modes, respectively. The estimated number of significant depth-of-discharge cycles for either energy storage system is less than 100 for the 10-year period.

Freeh, Joshua E.↗

Method of detecting system function by measuring frequency response

Real-time battery impedance spectrum is acquired using a one-time record. Fast Summation Transformation (FST) is a parallel method of acquiring a real-time battery impedance spectrum using a one-time record that enables battery diagnostics. An excitation current to a battery is a sum of equal amplitude sine waves of frequencies that are octave harmonics spread over a range of interest. A sample frequency is also octave and harmonically related to all frequencies in the sum. The time profile of this signal has a duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known and octave and harmonically related, a simple algorithm, FST, processes the time record by rectifying relative to the sine and cosine of each frequency. Another algorithm yields real and imaginary components for each frequency.

Morrison, John L.↗

Failure Modes Experienced on Spacecraft Nicd Batteries

A review was made of failures and irregularities experienced on nickel cadmium batteries for 31 spacecraft. Only rarely did batteries fail completely. In many cases, poorly performing batteries were compensated for by a reduction in loads or by continuing to operate in spite of out-of-voltage conditions. Low discharge voltage was the most common problem observed in flight spacecraft (42%). Spacecraft batteries are often designed to protect against cell shorts, but cell shorts accounted for only 16% of the failures. Other causes of problems were high charge voltage (16%), battery problems caused by other elements of the spacecraft (10%), and open circuit failures (6%). Problems of miscellaneous or unknown causes occurred in 10% of the cases.

Gross, S.↗

Laboratory discharge studies of a 6 V alkaline lantern-type battery Eveready Energizer no. 528, under various ambient temperatures (-15 deg C and + 22 deg C) and loads (30 omega and 60 omega)

The voltages of two Eveready No. 528 batteries, one the test battery, the other the control battery, were simultaneously recorded as they were discharged across 30 omega loads using a dual chart recorder. The test battery was initially put in a freezer at -15 + or - 3 C. After its voltage had fallen to .6 V, it was brought back out into the room at 22 + or - 3 C. A second run was made with 60 omega loads. Assuming a 3.0 V cut-off, the total energy output of the test battery at -15 C was 26 WHr 30 omega and 35 WHr 60 omega, and the corresponding numbers for the control battery at 22 C were 91 WHr and 100 WHr. When the test battery was subsequently allowed to warm up, the voltage rose above 4 V and the total energy output rose to 80 WHr 30 omega and 82 WHR 60 omega.

Ahrens, S. T.↗

Lightweight Battery Charge Regulator Used to Track Solar Array Peak Power

A battery charge regulator based on the series-connected boost regulator (SCBR) technology has been developed for high-voltage spacecraft applications. The SCBR regulates the solar array power during insolation to prevent battery overcharge or undercharge conditions. It can also be used to provide regulated battery output voltage to spacecraft loads if necessary. This technology uses industry-standard dc-dc converters and a unique interconnection to provide size, weight, efficiency, fault tolerance, and modularity benefits over existing systems. The high-voltage SCBR shown in the photograph has demonstrated power densities of over 1000 watts per kilogram (W/kg). Using four 150-W dc-dc converter modules, it can process 2500 W of power at 120 Vdc with a minimum input voltage of 90 Vdc. Efficiency of the SCBR was 94 to 98 percent over the entire operational range. Internally, the unit is made of two separate SCBR s, each with its own analog control circuitry, to demonstrate the modularity of the technology. The analog controllers regulate the output current and incorporate the output voltage limit with active current sharing between the two units. They also include voltage and current telemetry, on/off control, and baseplate temperature sensors. For peak power tracking, the SCBR was connected to a LabView-based data acquisition system for telemetry and control. A digital control algorithm for tracking the peak power point of a solar array was developed using the principle of matching the source impedance with the load impedance for maximum energy transfer. The algorithm was successfully demonstrated in a simulated spacecraft electrical system at the Boeing PhantomWorks High Voltage Test Facility in Seattle, Washington. The system consists of a 42-string, high-voltage solar array simulator, a 77-cell, 80-ampere-hour (A-hr) nickel-hydrogen battery, and a constant power-load module. The SCBR and the LabView control algorithm successfully tracked the solar array peak power point through various load transients, including sunlight discharge transients when the total load exceeded the maximum solar array output power.

Soeder, James F.↗

Predicting Thermal Response in a Li-ion Cell on a UAV Fight Profile

As the energy storage devices continue to "pack" more energy in a small space, any damage, battery component failure, manufacturing defect, or electrically abusing the battery can lead to catastrophic thermal runaway events. A catastrophic thermal event in a cell leads to high temperature, in some instances spewing of battery materials due to gas development from side reactions initiated due to high internal temperatures. Also, a thermal runaway event can propagate from a single "failed" cell to the pack in a battery pack, leading to a more significant event. Mitigating a thermal runaway event is important in the commercial and automotive sectors. However, preventing such events in an electric aircraft (or air taxis) is paramount due to the lack of alternatives in the event of a failure. Battery prognostics algorithms allow the prediction of state-of-charge (SOC) and end-of-life (EOL) of a Li-ion battery in a UAV (unmanned air vehicle) [1]. For this presentation, we will extend this two-level battery predictive algorithm to predict SOC, EOL, and estimated maximum temperature during a simulated flight. The model is extended by integrating a lumped physics-driven thermal model for high current densities [2]. The parameters used to control SOC and EOL are maximum storable charge, time constant for Li-ion diffusivity in the carbon particles, and internal cell resistance. Cycling leads to an increase in the heat generated by an aged Li-ion cell with a LiyCoO2 (LCO) cathode and a LixC6 (MCMB) anode. The aging of a cell leads to increase in SEI layer thickness, the diffusion time for the lithium ions inside the electrodes, and the local reaction rates, in addition to the thermodynamic abuse caused by fixed cycling voltages controlled by a Battery Management System. As the battery ages, the cell resistance increases, while the onset temperature of the thermal runaway decreases (depends on the cell chemistry and cell abuse history). Any large deviation of the cell temperature from the estimated (expected) value can identify a faulty cell. Since SEI decomposition has the lowest onset temperature in the series of reactions leading to thermal runaway, the model considers the self-heating rate of the SEI decomposition as onset temperature (similar to Ref. [3]). The parameters in the Arrhenius equation for the SEI heating rate depend on the number of cycles, the cell's operating temperature, and the cell's abuse history [4,5]. Coupling the electrochemical, thermal, and aging model allow the prognostic algorithm to estimate a typical cell voltage and temperature as a function of age (cycling and calendar), whose departure from measured values from the BMS is used to identify a safety event. In addition, we will present the results from two simulated flight scenarios for a UAV: typical and extreme, since the power requirements vary significantly during take-off, landing, and changing altitudes, while the power requirements remain low during the cruise. For this presentation, the power requirement for a battery pack in a UAV is scaled to a single cell. This cell is cycled through a simulated profile, and the data is collected and used to predict a safety event.

Li-ion↗

Integrated Power Source Grant

Traditional spacecraft power systems incorporate a solar array energy source, an energy storage element (battery), and battery charge control and bus voltage regulation electronics to provide continuous electrical power for spacecraft systems and instruments. Dedicated power conditioning components provide limited fault isolation between systems and instruments, while a centralized power-switching unit provides spacecraft load control. Battery undervoltage conditions are detected by the spacecraft processor, which removes fault conditions and non-critical loads before permanent battery damage can occur. Cost effective operation of a micro-sat constellation requires a fault tolerant spacecraft architecture that minimizes on-orbit operational costs by permitting autonomous reconfiguration in response to unexpected fault conditions. A new micro-sat power system architecture that enhances spacecraft fault tolerance and improves power system survivability by continuously managing the battery charge and discharge processes on a cell-by-cell basis has been developed. This architecture is based on the Integrated Power Source (US patent 5644207), which integrates dual junction solar cells, Lithium Ion battery cells, and processor based charge control electronics into a structural panel that can be deployed or used to form a portion of the outer shell of a micro-spacecraft. The first generation Integrated Power Source is configured as a one inch thick panel in which prismatic Lithium Ion battery cells are arranged in a 3x7 matrix (26VDC) and a 3x1 matrix (3.7VDC) to provide the required output voltages and load currents. A multi-layer structure holds the battery cells, as well as the thermal insulators that are necessary to protect the Lithium Ion battery cells from the extreme temperatures of the solar cell layer. Independent thermal radiators, located on the back of the panel, are dedicated to the solar cell array, the electronics, and the battery cell array. In deployed panel applications, these radiators maintain the battery cells in an appropriate operational temperature range.

Source record↗