Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Splat Quenching as a High Throughput Rapid Solidification Testing Method for Developing Additive Manufacturing Alloys

Splat quenching as a high throughput rapid solidification screening tool is evaluated. Samples were made using known alloys (SS316, IN625, Ti-5553) to evaluate and establish the microstructures for a variety of alloy systems as well as the predicted cooling rates. The samples are inductively heated and levitated prior to being struck between two platens that produce a high contact pressure and a thin sample resulting in cooling rates on the order of 10 6 to 10 7 K/s. Process parameters were evaluated with analytical models in addition to numerical simulations to provide an effect of process variables such as substrate material, melt superheat, and platen velocity on the resulting solidification. The splat thickness was found to be controlled by platen velocity, melt superheat, as well as the feedstock volume. The sample thickness is the key controlling factor for varying the average cooling rate experienced by the splat quenched sample. The splat quenching techniques can reach regions of rapid solidification space that meet and exceed laser and electron beam techniques across the sample. In conclusion, the results of the study provide a useful foundation in understanding the splat quenching technique and its potential as a low effort tool to explore rapid solidification effects on alloys.

Alloy Design↗

Dose-Volume Comparison of Proton Radiotherapy and Stereotactic Body Radiotherapy for Non-Small-Cell Lung Cancer

Purpose: This study designed photon and proton treatment plans for patients treated with hypofractionated proton radiotherapy (PT) at the Southern Tohoku Proton Therapy Center (STPTC). We then calculated dosimetric parameters and compared results with simulated treatment plans for stereotactic body radiotherapy (SBRT), using dose--volume histograms to clearly explain differences in dose distributions between PT and SBRT. Methods and Materials: Twenty-one patients with stage I non-small-cell lung cancer (stage IA, n = 15 patients; stage IB, n = 6 patients) were studied. All tumors were located in the peripheral lung, and total dose was 66 Gray equivalents (GyE) (6.6 GyE/fraction). For treatment planning, beam incidence for proton beam technique was restricted to two to three directions for PT, and seven or eight noncoplanar beams were manually selected for SBRT to achieve optimal planning target volume (PTV) coverage and minimal dose to organs at risk. Results: Regarding lung tissues, mean dose, V5, V10, V13, V15, and V20 values were 4.6 Gy, 13.2%, 11.4%, 10.6%, 10.1%, and 9.1%, respectively, for PT, whereas those values were 7.8 Gy, 32.0%, 21.8%, 17.4%, 15.3%, and 11.4%, respectively, for SBRT with a prescribed dose of 66 Gy. Pearson product moment correlation coefficients between PTV and dose--volume parameters of V5, V10, V15, and V20 were 0.45, 0.52, 0.58, and 0.63, respectively, for PT, compared to 0.52, 0.45, 0.71, and 0.74, respectively, for SBRT. Conclusions: Correlations between dose--volume parameters of the lung and PTV were observed and may indicate that PT is more advantageous than SBRT when treating a tumor with a relatively large PTV or several tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modern Rutherford Experiment: Tunneling of the Most Neutron-Rich Nucleus

A modern variation of the Rutherford experiment to probe the tunneling of exotic nuclear matter from the measurement of the residues formed in the bombardment of {sup 197}Au by extremely neutron-rich {sup 8}He nuclei is presented. Using a novel off-beam technique the most precise and accurate measurements of fusion and neutron transfer involving reaccelerated unstable beams are reported. The results show unusual behavior of the tunneling of {sup 8}He compared to that for lighter helium isotopes, highlighting the role of the intrinsic structure of composite many-body quantum systems and pairing correlations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Adaptive multibeam experiment for aeronautical and maritime services /AMEAMS/.

An experiment using NASA's ATS-G satellite was designed to provide essential data and field experience for the application of adaptive multiple satellite beam techniques to small mobile terminal communications system designs. Two approaches to the system were considered: an adaptive simultaneous multibeam mode and a hopped-beam mode. In the former case, both interbeam and intrabeam adaptive power management are used, while in the latter, beam energy is controlled through the use of time division techniques. The objectives of the experiment, design and implementation approaches, and potential applications are discussed.

Redisch, W. N.↗

Activated recombinative desorption: A potential component in mechanisms of spacecraft glow

The concept of activated recombination of atomic species on surfaces can explain the production of vibrationally and translationally excited desorbed molecular species. Equilibrium statistical mechanics predicts that the molecular quantum state distributions of desorbing molecules is a function of surface temperature only when the adsorption probability is unity and independent of initial collision conditions. In most cases, the adsorption probability is dependent upon initial conditions such as collision energy or internal quantum state distribution of impinging molecules. From detailed balance, such dynamical behavior is reflected in the internal quantum state distribution of the desorbing molecule. This concept, activated recombinative desorption, may offer a common thread in proposed mechanisms of spacecraft glow. Using molecular beam techniques and equipment available at Los Alamos, which includes a high translational energy 0-atom beam source, mass spectrometric detection of desorbed species, chemiluminescence/laser induced fluorescence detection of electronic and vibrationally excited reaction products, and Auger detection of surface adsorbed reaction products, a fundamental study of the gas surface chemistry underlying the glow process is proposed.

Cross, J. B.↗

Flip-chip and backside techniques.

State-of-the-art techniques for failure localization and design modification through bulk silicon are essential for multi-level metallization and new, flip chip packaging methods. The tutorial reviews the transmission of light through silicon, sample preparation, and backside defect localization techniques that are both currently available and under development. The techniques covered include emission microscopy, scanning laser microscope based techniques (electrooptic techniques, LIVA and its derivatives), and other non-IR based tools (FIB, e-beam techniques, etc.).

99 GENERAL AND MISCELLANEOUS↗

Depositing Diamondlike Carbon Films

New process demonstrated to make thin films (usually thousands of angstroms to few microns thick) that have properties of diamonds. Various plasma and ion-beam techniques employed to generate films. Films made by radio-frequency plasma decomposition of hydrocarbon gas or other alkanes, by low-energy carbon-ion-beam deposition, or by ion plating and dual ion technique using carbon target. Advantages of new process over others are films produced, though amorphous, are clear, extremely hard, chemically inert, of high resistivity, and have index of refraction of 3.2 properties similar to those of single-crystal diamonds. Films have possible uses in microelectronic applications, high-energy-laser and plastic windows, corrosion protection for metals, and other applications where desired properties of film shaped during the film-formation process.

Mirtich, M. J.↗

Interactions of satellite-speed helium atoms with satellite surfaces. 2: Energy distributions of reflected helium atoms

Energy transfer in collisions of satellite-speed (7,000 m/sec) helium atoms with a cleaned 6061-T6 satellite-type aluminum surface was investigated using the molecular-beam technique. The amount of energy transferred was determined from the measured energy of the molecular-beam and the measured spatial and energy distributions of the reflected atoms. Spatial distributions of helium atoms scattered from a 6061-T6 aluminum surface were measured. The scattering pattern exhibits a prominent backscattering, probably due to the gross surface roughness and/or the relative lattice softness of the aluminum surface. Energy distributions of reflected helium atoms from the same surface were measured for six different incidence angles. For each incidence angle, distributions were measured at approximately sixty scattering positions. At a given scattering position, the energy spectra of the reflected helium atoms and the background gas were obtained using the retarding-field energy analyzer.

Liu, S. M.↗

Freestanding nanostructures for three-dimensional superconducting nanodevices

Free-space nanostructures are the fundamental building blocks of three-dimensional (3D) nanodevices with multi-functionality beyond that achievable by planar devices. Here we developed a reliable technique for the site-specific post-growth geometrical manipulation of freestanding superconducting nanowires using ion-beam irradiation with nanometer-scale resolution to fabricate uniformly shaped and sized clean-surface 3D nanostructures. Such structures could integrate with conventional superconducting quantum interference devices to detect magnetic fields both parallel and normal to the substrate. Property characterizations suggest that our focused-ion-beam technique allows tailoring of freestanding superconducting loops for size and geometry, potentially for lab-on-chip experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Focused‐beam X‐ray fluorescence and diffraction microtomographies for mineralogical and chemical characterization of unsectioned extraterrestrial samples

Abstract This study describes the application of new synchrotron X‐ray fluorescence (XRF) and diffraction (XRD) microtomographies for the 3‐D visualization of chemical and mineralogical variations in unsectioned extraterrestrial samples. These improved methods have been applied to three compositionally diverse chondritic meteorite samples that were between 300 and 400 μm in diameter, including samples prepared from fragments of the CR2 chondrite LaPaz Icefield (LAP) 02342, H5 chondrite MacAlpine Hills (MAC) 88203, and the CM2 chondrite Murchison. The synchrotron‐based XRF and XRD tomographies used are focused‐beam techniques that measure the intensities of fluorescent and diffracted X‐rays in a sample simultaneously during irradiation by a high‐energy microfocused incident X‐ray beam. Measured sinograms of the emitted and diffracted intensities were then tomographically reconstructed to generate 2‐D slices of XRF and XRD intensity through the sample, with reconstructed pixel resolution of 1–2 μm, defined by the resolution of the focused incident X‐ray beam. For sample LAP 02342, primary mineral phases that were visualized in reconstructed slices using these techniques included isolated grains of α‐Fe, orthopyroxene, and olivine. For our sample of MAC 88203, XRF/XRD tomography allowed visualization of forsteritic olivine as a primary mineral phase, a vitrified fusion crust at the sample surface, identification of localized Cr‐rich spinels at spatial resolutions of several micrometers, and imaging of a plagioclase‐rich glassy matrix. In the sample of Murchison, major identifiable phases include clinoenstatite‐ and olivine‐rich chondrules, variable serpentine matrix minerals and small Cr‐rich spinels. Most notable in the tomographic analysis of Murchison is the ability to quantitatively distinguish and visualize the complex mixture of serpentine‐group minerals and associated tochilinite–cronstedtite intergrowths. These methods provide new opportunities for spatially resolved characterization of sample texture, mineralogy, crystal structure, and chemical state in unsectioned samples. This provides researchers an ability to characterize such samples internally with minimal disruption of sample micro‐structures and chemistry, possibly without the need for sample extraction from some types of sampling and capture media.

Geochemistry & Geophysics↗

Assessment of normal tissue complications following prostate cancer irradiation: Comparison of radiation treatment modalities using NTCP models

Purpose: Normal tissue complication probability (NTCP) of the rectum, bladder, urethra, and femoral heads following several techniques for radiation treatment of prostate cancer were evaluated applying the relative seriality and Lyman models. Methods: Model parameters from literature were used in this evaluation. The treatment techniques included external (standard fractionated, hypofractionated, and dose-escalated) three-dimensional conformal radiotherapy (3D-CRT), low-dose-rate (LDR) brachytherapy (I-125 seeds), and high-dose-rate (HDR) brachytherapy (Ir-192 source). Dose-volume histograms (DVHs) of the rectum, bladder, and urethra retrieved from corresponding treatment planning systems were converted to biological effective dose-based and equivalent dose-based DVHs, respectively, in order to account for differences in radiation treatment modality and fractionation schedule. Results: Results indicated that with hypofractionated 3D-CRT (20 fractions of 2.75 Gy/fraction delivered five times/week to total dose of 55 Gy), NTCP of the rectum, bladder, and urethra were less than those for standard fractionated 3D-CRT using a four-field technique (32 fractions of 2 Gy/fraction delivered five times/week to total dose of 64 Gy) and dose-escalated 3D-CRT. Rectal and bladder NTCPs (5.2% and 6.6%, respectively) following the dose-escalated four-field 3D-CRT (2 Gy/fraction to total dose of 74 Gy) were the highest among analyzed treatment techniques. The average NTCP for the rectum and urethra were 0.6% and 24.7% for LDR-BT and 0.5% and 11.2% for HDR-BT. Conclusions: Although brachytherapy techniques resulted in delivering larger equivalent doses to normal tissues, the corresponding NTCPs were lower than those of external beam techniques other than the urethra because of much smaller volumes irradiated to higher doses. Among analyzed normal tissues, the femoral heads were found to have the lowest probability of complications as most of their volume was irradiated to lower equivalent doses compared to other tissues.

60 APPLIED LIFE SCIENCES↗

Angular distribution of electrons elastically scattered from N2.

Measurement of the angular distribution of electrons elastically scattered from N2 as a function of energy, utilizing a crossed-beam technique. Measurements have been made of monoenergetic electrons with energies between 5 and 90 eV scattered from a collimated beam of N2 at angles from -114 to +160 deg. The wide angular range of the measurements has enabled the determination of the total elastic-scattering and momentum-transfer cross sections. The measurements are relative and have been normalized to Fisk's (1936) theoretical calculation at 5 eV. The results generally agree well with other published measurements and with theory.

Shyn, T. W.↗

Surface plasmon polariton assisted optical switching in noble bimetallic nanoparticle system

Photoresponse of bimetallic Au-Ag nanoparticle embedded soda glass (Au-Ag@SG) substrate is reported for surface plasmon assisted optical switching using 808 nm excitation. Au-Ag@SG system is made by an ion beam technique where Ag{sup +} is introduced first in the soda glass matrix by ion exchange technique. Subsequently, 400 keV Au{sup +} is implanted in the sample for different fluences, which is followed by an ion beam annealing process using 1 MeV Si{sup +} at a fixed fluence of 2 × 10{sup 16} ions·cm{sup −2}. Characteristic surface plasmon resonance (SPR) peaks around 400 and 550 nm provided evidence for the presence of Au and Ag nanoparticles. An optical switching in the Au-Ag@SG system with 808 nm, which is away from the characteristic SPR peaks of Ag and Au nanoparticles, suggests the possible role of two photon absorption (TPA) owing to the presence of interacting electric dipole in these systems. The role of surface plasmon polariton is emphasized for the propagation of electronic carrier belonging to the conduction electron of Au-Ag system in understanding the observed photoresponse. Unique excitation dependent photoresponse measurements confirm the possible role of TPA process. A competitive interband and intraband transitions in the bimetallic system of Au and Ag, which may be primarily responsible for the observation, are validated qualitatively using finite difference time domain calculations where inter-particle separation of Au and Ag plays an important role. Thus, a smart way of optical switching can be envisaged in noble bimetallic nanocluster system where long wavelength with higher skin depth can be used for communication purpose.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A real-time interferometer technique for compressible flow research

Strengths and shortcomings in the application of interferometric techniques to transonic flow fields are examined and an improved method is elaborated. Such applications have demonstrated the value of interferometry in obtaining data for compressible flow research. With holographic techniques, interferometry may be applied in large scale facilities without the use of expensive optics or elaborate vibration isolation equipment. Results obtained using holographic interferometry and other methods demonstrate that reliable qualitative and quantitative data can be acquired. Nevertheless, the conventional method can be difficult to set up and apply, and it cannot produce real-time data. A new interferometry technique is investigated that promises to be easier to apply and can provide real-time information. This single-beam technique has the necessary insensitivity to vibration for large scale wind tunnel operations. Capabilities of the method and preliminary tests on some laboratory scale flow fluids are described.

Bachalo, W. D.↗

Reliable four-point flexion test and model for die-to-wafer direct bonding

For many years, wafer-to-wafer (W2W) direct bonding has been very developed particularly in terms of bonding energy measurement and bonding mechanism comprehension. Nowadays, die-to-wafer (D2W) direct bonding has gained significant attention, for instance, in photonics and microelectro-mechanics, which supposes controlled and reliable fabrication processes. So, whatever the stuck materials may be, it is not obvious whether bonded D2W structures have the same bonding strength as bonded W2W ones, because of possible edge effects of dies. For that reason, it has been strongly required to develop a bonding energy measurement technique which is suitable for D2W structures. In this paper, both D2W- and W2W-type standard SiO{sub 2}-to-SiO{sub 2} direct bonding samples are fabricated from the same full-wafer bonding. Modifications of the four-point flexion test (4PT) technique and applications for measuring D2W direct bonding energies are reported. Thus, the comparison between the modified 4PT and the double-cantilever beam techniques is drawn, also considering possible impacts of the conditions of measures such as the water stress corrosion at the debonding interface and the friction error at the loading contact points. Finally, reliability of a modified technique and a new model established for measuring D2W direct bonding energies is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Light efficiency of cathodoluminescent screens excited by a runaway electron beam

A technique employing electron beams generated by an open gas discharge is proposed for measuring the light efficiency of phosphor coatings of cathodoluminescent screens. The total light efficiencies of various phosphor coatings in the medium excitation energy range ({epsilon} < 7 keV) are estimated with allowance for both the direct radiation flux outgoing from the phosphor screen and the backward radiation flux propagating along the exciting electron beam. The possibility is demonstrated of creating a high-luminance ({approx}20000 cd/m{sup 2}) cathodoluminescent source with a light efficiency of {approx}60 lm/W.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear Dynamics and Phase Space Manipulations of High-Brightness Beams

The project consisted of two main tasks. Each task had several specific aims. The three main objectives of Task 1 were: 1. Investigation of the flat beam technique to produce high transverse emittance ratio longitudinally-compressed bunches, 2. Exploration of a new chicane-like transverse-to-longitudinal phase space exchanger for precise pulse shaping and emittance exchange, 3. Applications of flat-beam with shaped current profile(s) to dielectric wakefield acceleration in an asymmetric waveguide. The outcome of our research was to performed details simulations of flat-beam generation and compression. Some preliminary experiment on flat-beam generation and compression were conducted at the FAST-IOTA injector in parallel to commissioning activities. Likewise, the longitudinal phase-space transformation was not fully explored; we participated in experiments conducted at the Argonne Wakefield Accelerator and especially introduced a simple transverse-shaping technique.

43 PARTICLE ACCELERATORS↗

SU-F-T-327: Total Body Irradiation In-Vivo Dose Measurements Using Optically Stimulated Luminescence (OSL) NanoDots and Farmer Type Ion Chamber

Purpose: This study was performed to analyze the agreement between optically stimulated luminescence (OSL) nanoDots measured doses and 0.6 cc Farmer type ionization chamber measured doses during total body irradiation (TBI). Methods: In-vivo dose measurements using OSL nanoDots and Farmer chamber were done in a total of twelve patients who received TBI at our center by bilateral parallel-opposed beams technique. In this technique, the patient is kept inside the TBI box which is filled with rice bags and irradiated using two bilateral parallel opposed beams of 40×40 cm{sup 2} size with 45° collimator rotation at an SSD of 333.5 cm in an Elekta Synergy linear accelerator. All patients received a dose of 2 Gy in single fraction as conditioning regimen. The beams were equally weighted at the midplane of the box. The nanoDots were placed over forehead, right and left neck, right and left lung, umbilicus, right and left abdomen, medial part of thigh, knee and toe. A 0.6 cc Farmer chamber was placed in between the thighs of the patient. Measured doses are reported along with the statistical comparisons using paired sample t-test. Results: For the above sites the mean doses were 212.2±21.1, 218.2±7.6, 218.7±9.3, 215.6±9.5, 217.5±11.5, 214.5±7.7, 218.3±6.8, 221.5±15, 229.1±11.0, 220.5±7.7 and 223.3±5.1 cGy respectively. For all OSL measurements the mean dose was 218.6±11.8 cGy. Farmer chamber measurements yielded a mean dose of 208.8±15.6 cGy. Statistical analysis revealed that there was no significant difference between OSL measured doses in forehead, right and left neck, right and left lung, umbilicus, right and left abdomen and toe and Farmer chamber measured doses (0.72≤p≤0.06). However the mean OSL doses at thigh and knee were statistically different (p<0.05) from the Farmer chamber measurements. Conclusion: OSL measurements were found to be in agreement with Farmer type ionization chamber measurements in in-vivo dosimetry of TBI.

60 APPLIED LIFE SCIENCES↗