Search NASA⌕ Search

SEARCH · Search NASA

Results for “building performance data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Test Hardware Design for Flightlike Operation of Advanced Stirling Convertors (ASC-E3)

NASA Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, the Thermal Energy Conversion branch at GRC has been conducting extended operation of a multitude of free-piston Stirling convertors. The goal of this effort is to generate long-term performance data (tens of thousands of hours) simultaneously on multiple units to build a life and reliability database. The test hardware for operation of these convertors was designed to permit in-air investigative testing, such as performance mapping over a range of environmental conditions. With this, there was no requirement to accurately emulate the flight hardware. For the upcoming ASC-E3 units, the decision has been made to assemble the convertors into a flight-like configuration. This means the convertors will be arranged in the dual-opposed configuration in a housing that represents the fit, form, and thermal function of the ASRG. The goal of this effort is to enable system level tests that could not be performed with the traditional test hardware at GRC. This offers the opportunity to perform these system-level tests much earlier in the ASRG flight development, as they would normally not be performed until fabrication of the qualification unit. This paper discusses the requirements, process, and results of this flight-like hardware design activity.

Oriti, Salvatore M.↗

Test Hardware Design for Flight-Like Operation of Advanced Stirling Convertors

NASA Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, the Thermal Energy Conversion branch at GRC has been conducting extended operation of a multitude of free-piston Stirling convertors. The goal of this effort is to generate long-term performance data (tens of thousands of hours) simultaneously on multiple units to build a life and reliability database. The test hardware for operation of these convertors was designed to permit in-air investigative testing, such as performance mapping over a range of environmental conditions. With this, there was no requirement to accurately emulate the flight hardware. For the upcoming ASC-E3 units, the decision has been made to assemble the convertors into a flight-like configuration. This means the convertors will be arranged in the dual-opposed configuration in a housing that represents the fit, form, and thermal function of the ASRG. The goal of this effort is to enable system level tests that could not be performed with the traditional test hardware at GRC. This offers the opportunity to perform these system-level tests much earlier in the ASRG flight development, as they would normally not be performed until fabrication of the qualification unit. This paper discusses the requirements, process, and results of this flight-like hardware design activity.

Oriti, Salvatore M.↗

Extended Operation of Stirling Convertors at NASA Glenn Research Center

NASA Glenn Research Center (GRC) has been supporting development of free-piston Stirling conversion technology for spaceflight electrical power generation since 1999. GRC has also been supporting the development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG project is providing life, reliability, and performance data for the Advanced Stirling Convertor (ASC). The Thermal Energy Conversion branch at GRC is conducting extended operation of several free-piston Stirling convertors. The goal of this effort is to generate long-term performance data (tens of thousands of hours) on multiple units to build a life and reliability database. Currently, GRC is operating 18 convertors. This hardware set includes Technology Demonstration Convertors (TDCs) from Infinia Corporation, of which one pair (TDCs #13 and #14) has accumulated over 60,000 hr (6.8 years) of operation. Also under test are various Sunpower, Inc. convertors that were fabricated during the ASC development activity, including ASC-0, ASC-E (including those in the ASRG engineering unit), and ASC-E2. The ASC-E2s also completed, or are in progress of completing workmanship vibration testing, performance mapping, and extended operation. Two ASC-E2 units will also be used for durability testing, during which components will be stressed to levels above nominal mission usage. Extended operation data analyses from these tests are covered in this paper.

Oriti, Salvatore, M.↗

General approaches for shear-correcting coordinate transformations in Bragg coherent diffraction imaging. Part II

X-ray Bragg coherent diffraction imaging (BCDI) has been demonstrated as a powerful 3D microscopy approach for the investigation of sub-micrometre-scale crystalline particles. The approach is based on the measurement of a series of coherent Bragg diffraction intensity patterns that are numerically inverted to retrieve an image of the spatial distribution of the relative phase and amplitude of the Bragg structure factor of the diffracting sample. This 3D information, which is collected through an angular rotation of the sample, is necessarily obtained in a non-orthogonal frame in Fourier space that must be eventually reconciled. To deal with this, the approach currently favored by practitioners (detailed in Part I) is to perform the entire inversion in conjugate non-orthogonal real- and Fourier-space frames, and to transform the 3D sample image into an orthogonal frame as a post-processing step for result analysis. In this article, which is a direct follow-up of Part I, two different transformation strategies are demonstrated, which enable the entire inversion procedure of the measured data set to be performed in an orthogonal frame. The new approaches described here build mathematical and numerical frameworks that apply to the cases of evenly and non-evenly sampled data along the direction of sample rotation ( i.e. the rocking curve). The value of these methods is that they rely on the experimental geometry, and they incorporate significantly more information about that geometry into the design of the phase-retrieval Fourier transformation than the strategy presented in Part I. Finally, two important outcomes are (1) that the resulting sample image is correctly interpreted in a shear-free frame and (2) physically realistic constraints of BCDI phase retrieval that are difficult to implement with current methods are easily incorporated. Computing scripts are also given to aid readers in the implementation of the proposed formalisms.

36 MATERIALS SCIENCE↗

Performance Assessment of Baseline Cells for the High Efficiency Space Power Systems Project

The Enabling Technology Development and Demonstration (ETDD) Program High Efficiency Space Power Systems (HESPS) Project, formerly the Exploration Technology Development Program (ETDP) Energy Storage Project is tasked with developing advanced lithium-ion cells for future NASA Exploration missions. Under this project, components under development via various in-house and contracted efforts are delivered to Saft America for scale-up and integration into cells. Progress toward meeting project goals will be measured by comparing the performance to these cells with cells of a similar format with Saft s state-of-the-art aerospace chemistry. This report discusses the results of testing performed on the first set of baseline cells delivered by Saft to the NASA Glenn Research Center. This build is a cylindrical "DD" geometry with a 10 Ah nameplate capacity. Testing is being performed to establish baseline cell performance at conditions relevant to ETDD HESPS Battery Key Performance Parameter (KPP) goals including various temperatures, rates, and cycle life conditions. Data obtained from these cells will serve as a performance baseline for future cell builds containing optimized ETDD HESPSdeveloped materials. A test plan for these cells was developed to measure cell performance against the high energy cell KPP goals. The goal for cell-level specific energy of the high energy technology is 180 Wh/kg at a C/10 discharge rate and 0 C. The cells should operate for at least 2000 cycles at 100 percent DOD with 80 percent capacity retention. Baseline DD cells delivered 152 Wh/kg at 20 C. This number decreased to 143.9 Wh/kg with a 0 C discharge. This report provides performance data and summarizes results of the testing performed on the DD cells.

Schneidegger, Brianne T.↗

Evaluating Building Energy Code Compliance and Savings Potential through Large-Scale Simulation with Models Inferred by Field Data

Building energy code compliance is the crucial link between the actual energy savings and the efficiency prescribed in energy codes. A research project aiming to identify opportunities to reduce energy consumption in new single-family residential construction by increasing compliance with the building energy code was conducted in several states of the United States. The study was comprised of three phases: (1) a baseline study to document typical practice and identify opportunities for improvement based on empirical data gathered from the field; (2) an education and training phase targeting the opportunities identified; and (3) a post-study to assess whether a reduction in average state-wide energy use could be achieved following the education and training phase. We proposed a novel methodology based on large-scale building energy simulation inferred by limited field data to assess the performance of a large population of homes. This paper presents the methodology, findings, and results of this study. The state-wide average energy consumption decreased at Phase III from Phase I for five of the seven states involved in the analysis. The measure-level savings potential analysis shows an overall reduction. Overall, the training and education phase plays a recognizable role in improving compliance with building energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Investigation of High Delta T Sensible Storage Integrated CO2 Heat Pump: Preprint

To assist building heating electrification, this paper numerically investigates a load flexible heat pump system for commercial buildings. The system consists of a CO2 vapor compression cycle, a sensible thermal storage tank, and an air handling unit. The thermal storage medium is inexpensive, non-toxic and stable anti-freeze solution (30% potassium acetate). The air handing unit has an indoor coil and a ventilation coil. The system can be used to manage building electric load. During peak hours, the heat pump is off and the hot solution water is discharged from the tank to heat up the indoor air and ventilation air. During the hour of charge, the heat pump delivers hot solution water to the tank and to the air. The tank can also stand by while the heat pump provides space heating directly. We selected a medium sized office building located in Minnesota as the representative building and used EnergyPlus to obtain its 24 hour load data. We designed three storage tank volumes assuming 50 degrees C, 65 degrees C and 80 degrees C tank temperatures to independently provide the building load for 4 hours in the morning. The higher the tank temperature, the smaller the required volume, and thus higher energy density. The effective energy density is 78 with an 80 degrees C tank, and 40 kWhth/m3 with 50 degrees C. We simulated the tank integrated heat pump performance subjected to the 24-hour building load profile and ambient data. The baseline is the same system without storage tank. There was a trade-off between the storage energy density and the charging COP. The charge hour COP was 2.77 to charge the tank to 80 degrees C, and 3.01 to 50 degrees C. The proposed system could shift building load from the peak hours (8:00 - 12:00) to off-business hour (23:00 - 7:00+1). It eliminated 100% compressor electricity use during the peak hours, and avoided a peak electric power of 34 kW. The 65 degrees C tank saved 9.5 kWhe (4%) considering all day operation, which was the best balance between energy density and the system operation efficiency among the three options.

CO2 heat pump↗

KGML-ag: a modeling framework of knowledge-guided machine learning to simulate agroecosystems: a case study of estimating N<sub>2</sub>O emission using data from mesocosm experiments

Abstract. Agricultural nitrous oxide (N2O) emission accounts for a non-trivial fraction of global greenhouse gas (GHG) budget. To date, estimating N2O fluxes from cropland remains a challenging task because the related microbial processes (e.g., nitrification and denitrification) are controlled by complex interactions among climate, soil, plant and human activities. Existing approaches such as process-based (PB) models have well-known limitations due to insufficient representations of the processes or uncertainties of model parameters, and due to leverage recent advances in machine learning (ML) a new method is needed to unlock the “black box” to overcome its limitations such as low interpretability, out-of-sample failure and massive data demand. In this study, we developed a first-of-its-kind knowledge-guided machine learning model for agroecosystems (KGML-ag) by incorporating biogeophysical and chemical domain knowledge from an advanced PB model, ecosys, and tested it by comparing simulating daily N2O fluxes with real observed data from mesocosm experiments. The gated recurrent unit (GRU) was used as the basis to build the model structure. To optimize the model performance, we have investigated a range of ideas, including (1) using initial values of intermediate variables (IMVs) instead of time series as model input to reduce data demand; (2) building hierarchical structures to explicitly estimate IMVs for further N2O prediction; (3) using multi-task learning to balance the simultaneous training on multiple variables; and (4) pre-training with millions of synthetic data generated from ecosys and fine-tuning with mesocosm observations. Six other pure ML models were developed using the same mesocosm data to serve as the benchmark for the KGML-ag model. Results show that KGML-ag did an excellent job in reproducing the mesocosm N2O fluxes (overall r2=0.81, and RMSE=3.6 mgNm-2d-1 from cross validation). Importantly, KGML-ag always outperforms the PB model and ML models in predicting N2O fluxes, especially for complex temporal dynamics and emission peaks. Besides, KGML-ag goes beyond the pure ML models by providing more interpretable predictions as well as pinpointing desired new knowledge and data to further empower the current KGML-ag. We believe the KGML-ag development in this study will stimulate a new body of research on interpretable ML for biogeochemistry and other related geoscience processes.

54 ENVIRONMENTAL SCIENCES↗

FY22 Laboratory Directed Research and Development Annual Report

The Laboratory Directed Research and Development (LDRD) program yields foundational scientific research and development (R&D) essential to growing SRNL’s core competencies, in alignment with SRNL’s Strategic Plan to provide long-term benefits to the Department of Energy (DOE), the National Nuclear Security Administration (NNSA), and other customers and stakeholders. Five strategic goals are outlined in SRNL’s strategic plan: 1) Provide applied science and engineering for EM’s active clean-up sites and LM’s post closure management sites; 2) Provide science-based solutions for gaps identified in nonproliferation strategic vision and support the government in actives impacting national security; 3) Lead ST&E as the central technical authority for processing tritium loaded reservoirs and support production of plutonium pits; 4) Align science and energy security programs by focusing modern modeling, simulation, and data analytics tools on materials engineering and performance applications; 5) Build a workforce for the future.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

HVAC modifications and computerized energy analysis for the Operations Support Building at the Mars Deep Space Station at Goldstone

The key heating, ventilation, and air-conditioning (HVAC) modifications implemented at the Mars Deep Space Station's Operation Support Building at Jet Propulsion Laboratories (JPL) in order to reduce energy consumption and decrease operating costs are described. An energy analysis comparison between the computer simulated model for the building and the actual meter data was presented. The measurement performance data showed that the cumulative energy savings was about 21% for the period 1979 to 1981. The deviation from simulated data to measurement performance data was only about 3%.

Halperin, A.↗

Sustainable Campus with PEV and Microgrid

Market penetration of electric vehicles (EVs) is gaining momentum, as is the move towards increasingly distributed, clean and renewable electricity sources. EV charging shifts a significant portion of transportation energy use onto building electricity meters. Hence, integration strategies for energy-efficiency in buildings and transport sectors are of increasing importance. This paper focuses on a portion of that integration: the analysis of an optimal interaction of EVs with a building-serving transformer, and coupling it to a microgrid that includes PV, a fuel cell and a natural gas micro-turbine. The test-case is the Nanyang Technological University (NTU), Singapore campus. The system under study is the Laboratory of Clean Energy Research (LaCER) Lab that houses the award winning Microgrid Energy Management System (MG-EMS) project. The paper analyses three different case scenarios to estimate the number of EVs that can be supported by the building transformer serving LaCER. An approximation of the actual load data collected for the building into different time intervals is performed for a transformer loss of life (LOL) calculation. The additional EV loads that can be supported by the transformer with and without the microgrid are analyzed. The numbers of possible EVs that can be charged at any given time under the three scenarios are also determined. The possibility of using EV fleet at NTU campus to achieve demand response capability and intermittent PV output leveling through vehicle to grid (V2G) technology and building energy management systems is also explored.

Singh, Reshma↗

FY24 Laboratory Directed Research and Development Annual Report

The Laboratory Directed Research and Development (LDRD) program yields foundational scientific research and development (R&D) essential to growing SRNL’s core competencies, in alignment with SRNL’s Strategic Plan to provide long-term benefits to the Department of Energy (DOE), the National Nuclear Security Administration (NNSA), and other customers and stakeholders. Five strategic goals are outlined in SRNL’s strategic plan: 1) Provide applied science and engineering for EM’s active clean-up sites and LM’s post closure management sites 2) Provide science-based solutions for gaps identified in nonproliferation strategic vision and support the government in activities impacting national security 3) Lead Science, Technology & Engineering as the central technical authority for processing tritium loaded reservoirs and support production of plutonium pits 4) Align science and energy security programs by focusing modern modeling, simulation, and data analytics tools on materials engineering and performance applications 5) Build a workforce for the future

Clark, Sue [Savannah River National Laboratory (SR↗

Comprehensive Total Cost of Ownership Quantification for Vehicles with Different Size Classes and Powertrains

In order to accurately compare the costs of two vehicles, the total cost of ownership (TCO) should consist of all costs related to both purchasing and operating the vehicle. This TCO analysis builds on previous work to provide a comprehensive perspective of all relevant vehicle costs of ownership. In this report, we present what we believe to be the most comprehensive explicit financial analysis of the costs that will be incurred by a vehicle owner. This study considers vehicle cost and depreciation, financing, fuel costs, insurance costs, maintenance and repair costs, taxes and fees, and other operational costs to formulate a holistic total cost of ownership and operation of multiple different vehicles. For each of these cost parameters that together constitute a comprehensive TCO, extensive literature review and data analysis were performed to find representative values in order to build a holistic TCO for vehicles of all size classes. The light- and heavy-duty vehicles selected for analysis in this report are representative of those that are on the road today and expected to be available in the future. Important additive analyses in this study include systematic analysis of vehicle depreciation, in-depth examination of insurance premium costs, comprehensive maintenance and repair estimates, analysis of all relevant taxes and fees, and considerations of specific costs applicable to commercial vehicles. We find that cars depreciate faster than light trucks and that older plug-in electric vehicles have a greater depreciation rate than newer electric vehicles. Light-duty vehicle (LDV) insurance costs show comparable costs for different powertrains, and lower costs for larger size classes. Medium- and heavy-duty vehicle (MHDV) insurance costs vary significantly by vocation. Electric and electrified powertrains have lower maintenance and repair costs than internal combustion engine (ICE) powertrains for all vehicle sizes, relative to vehicle price. MHDV maintenance and repair costs depend heavily on vocation and duty cycle. LDV taxes and fees are comparable across powertrain types and size classes, though marginally higher registration fees exist for alternative fuel vehicles. MHDV fees depend on the vocation, weight rating, and state. Many electric tractor trailers would be affected by additional battery weight, reducing the available payload capacity, and this cost can be substantial. Electric vehicle charging for commercial vehicles can be time-consuming; labor rates can cause this cost to dominate TCO. With improved knowledge of each of the cost components, we calculate a lifetime TCO for comparison across vehicles of different types and attributes. For a simulated small sport utility vehicle in 2025, modeled using Autonomie, the hybrid electric vehicle (HEV) has the lowest cost, followed by the conventional ICE vehicle. For MHDV, TCO can be drastically different depending on the vocation. Long-haul vehicles typically have the lowest per-mile costs. Excluding labor costs, the class 4 delivery has a comparable TCO to the day cab. Vocational trucks, refuse trucks, and transit buses have a high per-mile cost of ownership due to maintenance and insurance. For all of these vehicles, the cost of operating the vehicle is heavily weighted by the labor of the driver, followed by the fuel costs. While the HEV begins as the lowest cost powertrain for passenger vehicles, fuel cells are forecast to reach cost parity by 2030 when hydrogen prices reach $\$ 5$/kg while battery electric vehicles (BEV) reach cost parity by 2035 at a battery cost of $\$ 98$ per usable kWh of capacity, with these two technologies being the lowest cost in 2050. For the class 8 day cab tractor, the HEV and ICE vehicle begin as the lowest cost powertrains, and the 250-mile BEV reduces in cost from the most expensive to the least expensive by 2030.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SHAPA: An interactive software tool for protocol analysis applied to aircrew communications and workload

As modern transport environments become increasingly complex, issues such as crew communication, interaction with automation, and workload management have become crucial. Much research is being focused on holistic aspects of social and cognitive behavior, such as the strategies used to handle workload, the flow of information, the scheduling of tasks, the verbal and non-verbal interactions between crew members. Traditional laboratory performance measures no longer sufficiently meet the needs of researchers addressing these issues. However observational techniques are better equipped to capture the type of data needed and to build models of the requisite level of sophistication. Presented here is SHAPA, an interactive software tool for performing both verbal and non-verbal protocol analysis. It has been developed with the idea of affording the researchers the closest possible degree of engagement with protocol data. The researcher can configure SHAPA to encode protocols using any theoretical framework or encoding vocabulary that is desired. SHAPA allows protocol analysis to be performed at any level of analysis, and it supplies a wide variety of tools for data aggregation, manipulation. The output generated by SHAPA can be used alone or in combination with other performance variables to get a rich picture of the influences on sequences of verbal or nonverbal behavior.

James, Jeffrey M.↗

Scalable and Actionable Performance Measures for Traffic Signal Systems using Probe Vehicle Trajectory Data

Scalable and actionable performance measures for traffic signal systems provide opportunities for practitioners to measure and improve the transportation network. Historically, traffic signal improvements have relied on scheduled signal retiming based on limited data collection, or on the public to call and alert engineers of an issue. This inefficient method of improving signal timing led to the creation of automated traffic signal performance measures (ATSPMs). These metrics rely on expensive infrastructure, including detection and communications, which has produced barriers for numerous agencies to fully adopt. Recently, third-party data providers have begun to release vehicle trajectory data, which allows for enhanced signal metrics with no investment in physical equipment. The purpose of this study is to demonstrate the use of these data and summarize the scalability of the created metrics. This work builds on previous efforts to quantify signal performance on nine intersections in Michigan, U.S. Ten signalized corridors in Columbus, Ohio, were chosen to scale a performance assessment using crowdsourced trajectory data. A total of 136 intersections were assessed in 2-h intervals using data from all weekdays in 2017. High-level corridor summary metrics including average percent of vehicles stopping (18%–32%), average delay (9.4–20.5 s), and level of travel time reliability (1.23–2.73) were calculated for each corridor direction. Intersection-level metrics were also introduced, which can be used by practitioners to identify problems, improve signal timings, and prioritize future infrastructure investments.

99 GENERAL AND MISCELLANEOUS↗

Application and evaluation of a pattern-based building energy model calibration method using public building datasets

Building performance simulation has been adopted to support decision making in the building life cycle. An essential issue is to ensure a building energy simulation model can capture the reality and complexity of buildings and their systems in both the static characteristics and dynamic operations. Building energy model calibration is a technique that takes various types of measured performance data (e.g., energy use) and tunes key model parameters to match the simulated results with the actual measurements. This study performed an application and evaluation of an automated pattern-based calibration method on commercial building models that were generated based on characteristics of real buildings. A public building dataset that includes high-level building attributes (e.g., building type, vintage, total floor area, number of stories, zip code) of 111 buildings in San Francisco, California, USA, was used to generate building models in EnergyPlus. Monthly level energy use calibrations were then conducted by comparing building model results against the actual buildings' monthly electricity and natural gas consumption. The results showed 57 out of 111 buildings were successfully calibrated against actual buildings, while the remaining buildings showed opportunities for future calibration improvements. Enhancements to the pattern-based model calibration method are identified to expand its use for: (1) central heating, ventilation and air conditioning (HVAC) systems with chillers, (2) space heating and hot water heating with electricity sources, (3) mixed-use building types, and (4) partially occupied buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Cybersecurity Testbed for Smart Buildings

Smart buildings are equipped with a plethora of cyber-physical systems, such as Internet of Things (IoT) devices and building automation systems. These devices, especially in commercial buildings, use legacy communications and hardware that were not designed with cybersecurity in mind. With increasing cyber threats in recent years, smart buildings have become an increasing target for attacks, but not enough published data are available from these incidents to study or replicate the scenarios to defend buildings. As part of the U.S. Department of Energy-funded project focusing on developing the Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS) platform, we developed a cybersecurity test bed for smart buildings. This test bed includes a building simulation tool, virtual devices, emulated operational technology networks, and remote hardware-in-the-loop. Using this test bed, we performed different cyberattacks on the smart building model and collected both physical building data, to understand the impacts on the building, and network data, to aid in separating mechanical faults from cyberattacks during the detection. This test bed is a significant tool in protecting smart buildings from cyberattacks because it can aid in both cybersecurity analysis and the evaluation of other cyberattack detection tools by testing the tools in a secure environment without impacting the building operations.

cyber-physical systems↗