Search NASA⌕ Search

SEARCH · Search NASA

Results for “buses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Multi-Area Model-Free State Estimation via Distributed Tensor Decomposition

This paper proposes a model-free method for distribution system state estimation based on tensor completion using canonical polyadic decomposition. In particular, we consider a setting where the network is divided into multiple areas. The measured physical quantities at buses located in the same area are processed by an area controller. A third-order tensor is constructed to collect these measured quantities. The measurements are analyzed locally to recover the full state information of the network. A closed-form iterative algorithm based on the alternating direction method of multipliers is developed to obtain the low-rank factors of the whole network state tensor where information exchange happens only between neighboring areas. To demonstrate the efficacy of the developed algorithm, numerical simulations are carried out using an IEEE test system.

alternating direction method of multipliers↗

Understanding Impacts of Data Integrity Attacks on Transactive Control Systems

With the rapid growth of internet-connected smart devices capable of exchanging energy price information and adaptively controlling energy consumption of connected loads, the role of transactive control is expected to become more prominent in the modern grid. Transactive control systems integrate the wholesale and retail energy markets, and enable active participation of end users, thereby playing a key role in managing the rising number of distributed assets in the smart grid. The use of internet for the communication of data between the controllers at the building, distribution, and transmission levels makes the system susceptible to cyber-attacks. A skilled adversary can potentially manipulate the exchanged data with the intention of inflicting damage to the system. In this paper, four categories of metrics are put forth for evaluating the performance of the system when under data integrity attacks. A model for scaling-based data integrity attack has been described, and co-simulations have been performed on a 240 bus WECC transmission system model with detailed modeling of distribution systems at specific buses. Our results show that scaling-based data integrity attacks can have non-trivial impacts on the operational, financial, and comfort aspects of the transactive control system.

Smart grid, transactive control system, Buildings-↗

Machine Learning-based Cyber-Physical Anomaly Detection in Wide Area Voltage Control Systems

Wide-area voltage control systems (WAVCS) are widely deployed in power grid to improve the voltage stability in transmission system using Flexible AC Transmission System (FACTS) devices. The WAVCS relies on wide-area measurement and control signals for closed-loop control of FACTS devices to improve the transient voltage stability in power grid in real-time. Since the WAVCS utilizes a cyber-layer communication during its normal operation, they are susceptible to cyber attacks from adversaries which can lead to a voltage collapse if the attacks go undetected and unmitigated. This paper proposes a supervised machine learning (ML)-based anomaly detection algorithm for detecting various stealthy cyber attacks in the context of WAVCS cybersecurity. In particular, a fuzzy logic-based wide-area controller, as proposed by the Bonneville Power Administration (BPA), is implemented on the Kundur’s four machine two-area system that is integrated with a static var compensator (SVC) to improve voltage profile on sensitive buses. Later, different types of data integrity attacks, including pulse and ramp attacks, are considered on the wide-area measurement and control signals to analyze the performance of the proposed anomaly detector. Our experimental evaluation shows a promising performance with a high true-positive rate (more than 99%) and low false-negative rate (less than 1%) while exhibiting a small prediction time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Democratized Control Architecture for Regional Transmission Operators

As probably the most complicated and critical infrastructure system, U.S. power grids become increasingly vulnerable to extreme events such as cyber-attacks and severe weather, as well as higher DER penetrations and growing information mismatch among system operators, utilities (transmission or generation owners), and end-users. This paper proposes a data-driven democratized control architecture considering two democratization pathways to assist transmission system operators, with a targeted use case of developing online proactive islanding strategies. Detailed discussions on load capability profiling at transmission buses and disaggregation of DER generations are provided and illustrated with real-world utility data. By Combining network and operational constraints, transmission system operators can be equipped with new tools built on top of this architecture, to derive accurate, proactive, and strategic islanding decisions to incorporate the wide range of dynamic portfolios and needs when facing extreme events or unseen grid contingencies.

Power System Reliability, Islanding, Democratized ↗

Extended Frequency Divider for Bus Frequency Estimation Considering Virtual Inertia from DFIGs

Accurate estimation of local bus frequency is important for effectively controlling both synchronous and nonsynchronous generators. As the power grid evolves to accommodate essential reliability services such as virtual inertia from nonsynchronous generators, conventional techniques to estimate frequency face challenges. This paper proposes a new frequency estimation method that can effectively include the inertia contributions from double-fed wind generators (DFIGs). This is achieved through the proposed extended frequency divider formula (FDF) to include the contributions of DFIGs via Thevenin equivalents. The proposed extended FDF does not suffer from numerical issues as compared to existing phasor angle derivative-based approaches. Moreover, the knowledge of the rotor speeds of the synchronous machine and DFIGs as well as of the network admittance matrix allows estimating the frequencies of all buses in the grid, thereby significantly improving system situational awareness with a limited number of measurements. Numerical results on the IEEE 39-bus power system with DFIGs show that the proposed method achieves more accurate bus frequency estimations than the original FDF formula and other approaches based on the numerical derivation of the bus voltage phase angles.

double-fed induction generator↗

Distributed Frequency Divider for Power System Bus Frequency Online Estimation Considering Virtual Inertia From DFIGs

In this work, a distributed frequency divider is proposed to estimate power system bus frequency with a limited number of PMUs while considering the inertial contributions from double-fed induction generators (DFIGs). The key idea is to reformulate the original frequency divider by modeling the contributions of DFIGs with inertia emulation and external regional power system through Thevenin equivalents. The distributed frequency divider is general and able to estimate local bus frequencies in a distributed manner. Besides, only the knowledge of the rotor speeds of synchronous generator, boundary bus frequencies and terminal bus frequencies of DFIGs as well as the admittance matrix are required to estimate the frequencies at all buses. This is drastically different from existing approaches that require system observability by PMUs to monitor all bus frequencies. Numerical results carried out on the IEEE 39-bus and modified 118-bus power systems with DFIGs demonstrate and effectiveness and robustness of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power System Network Reduction for Power Hardware-in-the-Loop Simulation

This paper proposes single-port equivalent and two-port equivalent network reduction methods to respectively reduce single-port and two-port areas in a large power network. Parameters of the reduced systems are rigorously derived, which guarantees that the electrical quantities at the port(s) remain unchanged over the reduction, including voltage magnitude and phase and active and reactive power injections into the area to be reduced. The proposed techniques are applied to reduce a practical Maui grid, where the total numbers of buses, lines and transformers are respectively reduced from 212, 106 and 108 to 45, 30 and 13. Dynamic behaviors between the full model and the reduced model are compared in detail to illustrate the efficacy and accuracy of the proposed network reduction.

model reduction↗

Grid Optimization Competition on Synthetic and Industrial Power Systems

This paper summarizes a grid optimization (GO) competition effort in the United States to find the best solution strategies for up to interconnect-scale power system networks with around 32,000 buses. The optimization problem is a mixedinteger, non-convex non-linear problem, (MINLP) and includes discrete variables such as unit commitment and line switching, control settings (transformer taps and phase shifters with impedance correction tables), and bus shunts. The case study includes six actual industry grids as well as 16 realistic synthetic grids created by three different dataset teams. The winners are selected and ranked based on scoring criteria, which consider the solution quality (such as objective functions) within time limits. Nine winner teams are selected from 26 competitor teams. The results achieved by different teams are described and the performance of different algorithms on synthetic grids and actual industry grids are compared and analyzed.

mixed-integer non-linear programming↗

A VSC-HVDC-Assisted Black-Start Strategy in Bulk Power Systems a Case Study in San Diego

With the worldwide growth in deploying high-voltage direct current (HVDC) transmission systems, their ability to facilitate black-start (BS) restoration has been a research topic of interest. In this context, voltage source converter (VSC)-HVDC is regarded as a BS resource, and this paper proposes a VSC-HVDC-assisted parallel BS restoration strategy in bulk power systems. The proposed strategy consists of two stages: 1) determination of the VSC and generator startup sequence and 2) load restoration simulation. In the first stage, the entire blackout system is sectionalized into multiple subsystems. Each subsystem includes a VSC-HVDC station or traditional BS unit, it independently determines its generator startup timeline and the energization timelines for buses and lines. The second stage involves load restoration, conceptualized as a modified unit commitment problem, with the timelines established in the first stage work as critical inputs. The proposed BS restoration strategy is tested on the San Diego power system to simulate the 2011 Southwest blackout. The simulation results validate the effectiveness of using VSC-HVDC links as a BS resource which not only speeds up the restoration process but also reduces both energy and economic losses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generalized Power Flow Model of an Extra High-Power Multi-Terminal HVdc Transmission Grid with Parallel-Connected and Voltage-Stacked Converters

To increase power transfer capacity of high-voltage direct current (HVdc) transmission, a new extra high-power HVdc architecture with multiple standard modular multilevel converters (MMCs) per substation has recently been introduced. This paper proposes a power flow model for a multi-terminal HVdc (MTdc) grid with this innovative substation architecture. The proposed MTdc model can be integrated seamlessly with existing ac-dc power flow algorithms with minimal modifications. The model is applicable to various MTdc grid types and topologies, different numbers of dc buses, dc lines, and MMCs per substation, along with diverse control parameters. In addition, it accurately captures both balanced and unbalanced operations of the MTdc grid. The proposed model is verified using a 5-terminal bipole MTdc grid that spans 4 areas in the Eastern Interconnection system of the USA. The numerical solutions obtained from unified and sequential ac-dc power flow algorithms under different operating conditions closely match the time-domain simulation results in PSCAD, validating the accuracy and versatility of the proposed MTdc power flow model.

Nguyen, Quan H.↗

Machine Learning-Based Prediction of Distribution Network Voltage and Sensor Allocation

Increasing penetration levels of fast-varying energy resources might negatively affect power system operation. At the same time, sensor deployment throughout distribution networks improves system awareness and enables the development of new and advanced voltage control solutions. Such control techniques rely on accurate prediction in anticipation of voltage violation scenarios. This paper analyzes various approaches to voltage prediction in a distribution system, and it is shown that combining multiple techniques into a single regressor improves its predictive power. Moreover, a two-step regressor is proposed in which initial predictions based on a global regressor are refined by local regressors; in this case, prediction errors decrease significantly. Additionally, a clustering approach is employed to perform sensor allocation so that only the most influential buses are selected for monitoring without diminishing prediction accuracy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Discrete Empirical Interpolation Method Based Dynamic Load Model Reduction

Dynamic load models add significant complexity to bulk power system time-domain simulations. The complexity is due to the large number of ordinary differential equations (ODEs) introduced by the dynamic load components such as induction motors. It is challenging to derive reduced-order models (ROMs) for dynamic loads due to the nonlinear functions in their governing equations. This paper applies the discrete empirical interpolation method enhanced proper orthogonal decomposition (DEIM-POD) to approximate the full dynamic load model with the ROM that minimizes the projection error of the nonlinear functions in dynamic load ODEs onto their dominant modes. This approach only requires evaluation of nonlinear functions at selected observation points. The observation points selected by DEIM also provide information for screening critical load buses where dynamic load model parameters contribute the most to the accuracy of ROM across multiple contingencies. The proposed approach is validated on IEEE 9-bus, WECC 179-bus and 2384-bus Polish systems.

bulk power system↗

A New Distributed Model-Free Control Strategy to Diminish Distribution System Voltage Violations

This paper proposes a new distributed model-free control (MFC) strategy for dynamic voltage control to diminish distribution systems' voltage violations. The objective is to maintain all critical load bus voltages within the acceptable ANSI Range A (+/- 5% of nominal). The distributed MFC strategy, which only requires local voltage measurements from designated load buses, controls online the reactive power generation of available synchronous generator (SG)-based and photovoltaic (PV)-based distributed generators (DGs). The distributed MFC strategy is computationally efficient and does not require modelling of the different system components and disturbances. Time-domain dynamic simulations are conducted for the 21-bus test distribution system fed by multiple DGs to verify the performance of the proposed MFC strategy, and the results are compared against the conventional model-based microgrid voltage stabilizer (MGVS) control strategy. The simulation results show that the distributed MFC strategy provides minimal voltage violations and achieves the dynamic voltage stability of the system under diverse disturbances.

Hatipoglu, Kenan↗

A Distributionally Robust Optimization Framework for Stochastic Assessment of Power System Flexibility in Economic Dispatch

Given the complexity of power systems, particularly the high-dimensional variability of net loads, accurately depicting the entire operational range of net loads poses a challenge. To address this, recent methodologies have sought to gauge the maximum range of net load uncertainty across all buses. In this paper, we consider the stochastic nature of the net load and introduce a distributionally robust optimization framework that assesses system flexibility stochastically, accommodating a minimal extent of system violations. We verify the proposed method by solving the flexibility of the economic dispatch problem on four distinct IEEE standard test systems. Compared to traditional deterministic flexibility evaluations, our approach consistently yields less conservative flexibility outcomes.

distributionally robust optimization↗

Coordination of Networked Microgrids for Supporting Voltages of Bulk Power Systems

Active distribution system resources have the potential to support the bulk power system (BPS) during abnormal conditions, increasing reliability and resilience of power systems and end-use customers. This paper investigates for the first time the BPS voltage support provided by networked microgrids at the feeder level. A peer-to-peer (P2P) communication control framework is introduced to enable the coordination of multiple microgrids in a mixed ownership environment. This allows the microgrids to run a consensus algorithm (CA) to distributedly determine their own reactive power injections. Thus, the reactive power injection contribution is realized in a fair manner by having the same ratio of reactive power injection to the reactive power headroom for all microgrids. The CA implementation and performance within the P2P network framework are demonstrated on the IEEE 39-bus testcase system with 10 microgrids part of the distribution feeder assumed to be connected to one of the BPS buses.

Vu, Thanh Long↗

A Sequential Model Predictive and Deep Reinforcement Learning-Based Controller for Distribution System Outage Mitigation under Hurricane Events

This paper proposes a proactive outage mitigation framework for power distribution networks to withstand hurricane-induced disruptions. It leverages Model Predictive Control (MPC) to identify safe lines for proactive switching during hurricanes, minimizing the risk of cascading failures and voltage violations. The switching strategies optimized by MPC are sequentially integrated with a Deep Reinforcement Learning agent using the Advantage Actor-Critic algorithm, enabling dynamic line switching to maximize connected buses and minimize voltage violations in real time. Using a probabilistic hurricane model, the framework predicts line failures and adapts to varying conditions to enhance grid resilience. Simulations on the IEEE 123-bus system demonstrate its effectiveness in maintaining high connectivity and minimizing disruptions. Real-time testing with an RTDS confirms the practicality and reliability of the proposed approach.

Selim, Alaa [University of Connecticut]↗

ML-Based Power System Stability Assessment Considering Network Topology Changes: WECC 20,000+ Bus System Case Study

Modern power grids are fast-changing and thus require real-time monitoring and online stability assessment. With the rapid development of machine learning (ML) techniques, using data-driven models to provide fast and accurate estimations of power system stability marginal information, such as frequency nadir for frequency stability and critical clearing time (CCT) for transient stability, have become possible. However, despite the numerous research on ML-based methods for frequency nadir and CCT prediction, there is limited work on the impact of different network topology changes. Furthermore, most previous studies only focused on small or synthetic systems, and there is a lack of research on actual large power system models. In this paper, the above issues are addressed by studying the actual U.S. Western Electricity Coordinating Council (WECC) system model with more than 20,000 buses. Massive simulations are conducted in PowerWorld Simulator to study the impact of various topology change scenarios on both frequency stability and transient stability. System operating information is extracted from the success dispatch cases of various network topologies to generate a comprehensive dataset for ML-based models. Two ML methods, random forest (RF) and multilayer perceptron (MLP) neural network, are trained and tested for both frequency nadir prediction and CCT prediction. Test results have proven the models are capable of online stability assessment for large power networks such as the WECC system with sufficient accuracy.

critical clearing time↗

Challenges and Solutions for Real-Time Phasor Modeling of Large-scale Distribution Network with High PV Penetration

The conversion process of a practical large-scale feeder data from a quasi-static time series (OpenDSS) model into a real-time phasor model (ePHASORSIM in Opal-RT) is discussed in the paper. The process is implemented using an open source Python software. Previous reported implementations for the conversion process lead to several errors when applied to a larger-scale system such as the one considered here. Hence in this work, we describe the common issues in this conversion and propose a customized solution to enhance the efficiency of the conversion and reduce the complexity in the process. A quantitative validation of the enhanced conversion process is presented in this work using an actual high PV penetration feeder model that consists of 2230 buses, and using actual load and PV profile data. After a detailed analysis, this customized conversion software will be made available as an open source tool and is expected to be helpful for researchers who want to pursue a similar conversion. Solutions to various observed issues such as identifying the lines due to islanded network, representation of full impedance model of transformer/lines as sequential models, complexity in the representation of single phase buses/lines as three phase buses/lines to make it compatible with the simulator platform are discussed. Comparison of power flow and time series simulation results obtained from both OpenDSS and ePHASORsim models show very low errors, validating the accuracy of the proposed conversion process.

14 SOLAR ENERGY↗