Search NASA⌕ Search

SEARCH · Search NASA

Results for “cable aging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Hygrothermal aging effects on polyimide and acrylate-based adhesive materials in high-performance flat-flex cable assemblies

Flat-flex assemblies are widely used across a diverse range of technologies, including consumer electronics, automotive systems, aerospace and defense applications, and medical devices, due to their compact form factor and flexibility. However, environmental stressors like temperature and humidity are known to degrade performance over time, though the main mechanisms for degradation remain unknown. Here, in this work, we examined the aging behavior of copper/polyimide/adhesive laminate systems under varying temperature and humidity conditions, focusing on material degradation and its effects on mechanical and dielectric properties. Results show that peel strength and breakdown voltage decrease with exposure time, temperature, and humidity; spectroscopic characterization revealed that the adhesive, and not the polyimide, is the weak link in the material stack-up. The adhesive, identified as a butyl acrylate-acrylonitrile (BA-AN) copolymer, exhibited age-related spectral changes that correlated with exposure severity and duration. Hydrolysis at BA ester and AN nitrile groups was identified as the primary degradation mechanism, producing amides, acids, and alcohols. We developed a mechanistic model that connects kinetic parameters for BA-AN spectral band decay to peel strength and breakdown voltage, and implicates hydrolysis at the AN moiety, not BA, in performance decrements. Modeling predictions at ambient conditions indicate faster decline in peel strength than dielectric strength at early times, followed by plateauing of both properties at longer times. These findings provide critical insights into laminate aging mechanisms and highlight the importance of addressing BA-AN degradation to improve the long-term reliability of these systems in high-humidity environments.

organic↗

Development and implementation of an in-situ cable condition monitoring method for nuclear power plants - 130

The sustainability of the existing fleet of nuclear power reactors depends on utilities' ability to manage the aging of key components that cannot easily or economically be replaced or upgraded. Cables, metals, and concrete structures are among the major and key components that the industry and government are working on to ensure the long term reliability and safety of nuclear plants. To ensure that these key components continue to meet their performance requirements, new testing and condition monitoring technologies must be developed that are capable of identifying and quantifying degradation in these materials. The work presented in this paper focuses on the development and implementation of an in-situ condition monitoring method for nuclear power plant cables. This cable condition monitoring method is based on the frequency domain reflectometry (FDR) technique, which is a non-destructive in-situ electrical test that uses the principle of transmission line theory to locate and quantify impedance changes in a cable circuit. Through extensive research, development, and validation, the FDR test technique has been adapted as a cable condition monitoring method that trends with increasing cable degradation. In addition, the FDR data has been correlated to the industry standard elongation at break (EAB) test to quantify the degree of localized degradation in nuclear plant cable insulation material caused by long term exposure to high temperatures and radiation. By correlating FDR to EAB, the aging condition of cables routed through harsh environments can be better understood in relation to its ability to perform its intended function. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Damage in Medium Voltage Cable Using Machine Learning

Developments in cable test instrumentation coupled with artificial intelligence and machine learning (ML) to aid in interpretation of cable test signals supports the feasibility for automated analysis of reflectometry tests for low voltage power cables. This work seeks to leverage prior ML work and success for low voltage cables to evaluate potential application to medium voltage (2kV to 10kV) installations. The Accelerated and Real-Time Environmental Nodal Assessment (ARENA) Cable Motor Test Bed at Pacific Northwest National Laboratory (PNNL) was used to test a medium voltage cable with several types of damage including thermal aging and low resistance conductor-to-shield faults. The cable was tested using an inductive clamshell coupler to protect the test instruments from the energized cable voltages that would damage the test instruments if coupled directly to the energized conductor.

42 ENGINEERING↗

Analysis of simultaneous thermal/gamma radiation aging of cross-linked polyethylene (XLPE) insulation—interim status report

Cross-linked polyethylene (XLPE) is the most common cable insulation found in nuclear containment, and is therefore a priority material for investigation of long term aging effect from elevated temperature combined with gamma radiation exposure. Prior work has identified the possibility of anomalous aging behavior in XLPE such as the inverse temperature effect in which radiation exposure is more damaging at lower temperatures than at higher temperatures. We explored simultaneous aging of XLPE insulation from modern Firewall® III nuclear cables at 60, 90, and 115 °C, at gamma dose rates from 116 to 540 Gy/h, for exposure periods up to 25 d. XLPE samples exposed in this way were characterized using the percent gel and uptake factor method. For the conditions and material examine, degradation behavior was seen to track proportionally with increasing temperature, rather than to exhibit greater degradation at lower temperatures. Ongoing work including similar aging at 25 °C and characterization of the XLPE samples using other methods will further elucidate these initial results

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status Report and Research Plan for Cables Harvested from Crystal River Unit 3 Nuclear Generating Plant

Harvested cables from operating or decommissioned nuclear power plants present an important opportunity to validate models, understanding material aging behavior, and validate characterization techniques. Crystal River Unit 3 Nuclear Generating Plant is a pressurized water reactor that was licensed to operate from 1976 to 2013. Cable segments were harvested and made available to the Light Water Reactor Sustainability research program through the Electric Power Research Institute. Information on the locations and circuits within the reactor from whence the cable segments came, cable construction, sourcing and installation information, and photographs of the cable locations prior to harvesting were provided. The cable variations provided represent six of the ten most common cable insulations in the nuclear industry and experienced service usage for periods from 15 to 42 years. Subsequently, these cables constitute a valuable asset for research to understand aging behavior and measurement of nuclear cables. Received cables harvested from Crystal River Unit 3 Nuclear Generating Plant consist of low voltage, insulated conductor surrounded by jackets in lengths from 24 to 100 feet each. Cable materials will primarily be used to investigate aging under simultaneous thermal and gamma radiation exposure. Each cable insulation and jacket material will be characterized in its as-received condition, including determination of the temperatures associated with endothermic transitions in the material using differential scanning calorimetry and dynamic mechanical analysis. Temperatures for additional thermal exposure aging will be selected following the thermal analysis to avoid transitions in accelerated laboratory aging that do not occur in field conditions. Aging temperatures above thermal transitions may also be targeted to investigate the potential for artifacts in lifetime prediction from rapid accelerated aging. Total gamma doses and dose rates targeted for each material will be determined based on filling gaps in prior work, known limits of material classes and resource constraints. Experimental plans will be developed in the context of existing data for the insulation and jacket materials available in published Department of Energy and Electric Power Research Institute reports toward addressing identified knowledge gaps.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Identification and repair of intermittent cable faults in nuclear power plants - 131

The nuclear industry uses cable circuits as an integral part of a plant's reactor protection system (RPS), instrumentation and control (I and C) and power distribution systems. The reliability of these systems is critical for continued operation of the world's aging nuclear fleet, as well as for safe shutdown of the reactor. When intermittent faults occur in cable circuits, the symptom of the problem often appears and disappears in milliseconds while the aftereffects can result in spurious alarms and automatic actuation of safety systems. Problems are compounded when component degradation causes a cable circuit to transmit inaccurate information that does not represent actual plant operating conditions. The root cause of intermittent cable circuit operation can include degradation of cable and connectors from heat, humidity, radiation, and vibration. Unlike hard faults (which are constant open or short circuits), intermittent faults are defined as a temporary change in impedance that may only last for a few milliseconds. While less disruptive than hard faults, signal spiking from intermittent faults can often lead to alarm conditions and reactor trips. A soft fault is defined as a subtle variation the electrical characteristics of the circuit that still permit the continued operation of the circuit. A soft fault may be a precursor to a hard fault due to continued degradation of the fault over time. The focus of this paper is the description of a cable testing system that can be connected to an active, low frequency circuit and continuously monitor electrical characteristics using the time domain reflectometry (TDR) technique until an intermittent impedance change occurs. This technique uses the difference in frequency response of the circuit and the TDR to isolate the TDR signature from the active circuit data . When a momentary impedance change occurs that exceeds a preconfigured limit threshold, the distance to fault data is automatically overlaid with the healthy baseline reference and stored in a database for diagnosis and repair. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Risk-Informed Safety Margin Characterization Case Study: Selection of Electrical Equipment to Be Subjected to Environmental Qualification

The Risk-Informed Safety Margin Characterization (RISMC) pathway of the DOE’s Light Water Reactor Sustainability (LWRS) program focuses on advancing the state of the art in safety analysis and risk assessment to support decision-making on nuclear power plant operation well beyond the originally designed lifetime of the plants (i.e., beyond 60 years). Among the issues being addressed in RISMC is the significance of SSC aging and how confident we are about our understanding of its impact on the margin between the loads SSCs are expected to see during normal operation and accident conditions, and the SSC capacities (their ability to resist those loads) as the SSCs age. In this paper, a summary is provided of a case study that examines SSC aging from an environmental qualification (EQ) perspective. The case study illustrates how the state of knowledge regarding SSC margin can be characterized given the overall integrated plant design, and was developed to demonstrate a method for deciding on which cables to focus, which cables are not so important from an environmental qualification margin standpoint, and what plant design features or operating characteristics determine the role that environmental qualification plays in establishing a safety case on which decisions regarding margin can be made. The selection of cables for which demonstration of margin with respect to aging and environmental challenges uses a technique known as Prevention Analysis. Prevention Analysis is a Boolean method for optimal selection of SSCs (that is, those combinations of SSCs both necessary and sufficient to meet a predetermined selection criterion) in a manner that allows demonstration that plant-level safety can be demonstrated by the collection of selected SSCs alone. Choosing the set of SSCs that is necessary and sufficient to satisfy the safety objectives, and demonstrating that the safety objectives can be met effectively, determines where resources are best allocated to assure SSC performance margin. The paper describes the resulting component types that were selected by Prevention Analysis and identifies the accident sequence characteristics that cause these component types to be important from an EQ and aging perspective (and, hence, worthwhile evaluating the extent of safety margin). In addition, component types not selected as needing significant margin from an EQ and aging perspective are discussed and an engineering rationale is developed justifying the lack of need to apply resources to demonstrating margin for these component types. This rationale is in terms of design features of the plant and operating characteristics that make these component types less important from an EQ and aging perspective. While the case study focuses on EQ and aging of equipment and cables located inside the containment of this PWR, the prevention analysis method is demonstrated to be an effective technique for identification of minimal collections of components that would be effective in managing safety for a variety of issues associated with aging and long-term operation of the fleet of plants.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Accelerated thermal aging of harvested hypalon jacket for remaining useful life determination and diagnosis - 210

For nuclear power plants (NPPs) considering second license renewal for their operation beyond 60 years, knowledge of long-term operation, condition monitoring, and viability for the reactor components including reactor pressure vessel, concrete structures, and cable systems is essential. Such knowledge will provide NPPs with a game plan to predict performance and to estimate costs that are associated with monitoring or replacement programs for the affected systems. For cable systems that encompass a wide variety of materials, manufacturers, and in-plant location, accelerated aging of harvested cable jacket and insulation can provide insight as to remaining useful life and methods for monitoring. Accelerated thermal aging in air at temperatures between 80 deg. C and 120 deg. C was carried out on a multi-conductor control rod cable that had been inservice for over 30 years and was made by Boston Insulated Wire with Hypalon{sup TM} cable jacket and ethylene-propylene rubber insulation. From elongation at break (EAB) measurements and supporting Arrhenius analysis of the jacket material, an activation energy of 97.84 kJ/mol was estimated and the time to degradation, as represented by 50% EAB at the expected maximum operating temperature of 45 deg. C, was estimated to be 80 years. These values were slightly below previous measurements on similar BIW Hypalon cable jacket and could either be attributed to inservice degradation or variations in material properties from process variations. In addition, results from indenter modulus measurements and Fourier transform infrared spectroscopy suggest possible markers that could be beneficial to monitor cable conditions. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Aging Mechanisms and Nondestructive Aging Indicator of Filled Cross-linked Polyethylene (XLPE) Exposed to Simultaneous Thermal and Gamma Radiation

Aging mechanisms and a nondestructive aging indicator of filled cross-linked polyethylene (XLPE) cable insulation material used in nuclear power plants (NPPs) are studied. Using various material characterization techniques, likely candidates and functions for the main additives in a commercial filled-XLPE insulation material have been identified. These include decabromodiphenyl ether and Sb2O3 as flame retardants, ZnS as white pigment and polymerized 1,2-dihydro-2,2,4-trimethylquinoline as antioxidant. Gas chromatography-mass spectrometry, differential scanning calorimetry, oxidation induction time and measurements of dielectric loss tangent are utilized to monitor property changes as a function of thermal and radiation exposure of the cable material. Small-molecular-weight hydrocarbons are evolve with gamma radiation aging at 90 °C. The level of antioxidant decreases with aging by volatilization and chemical reaction with free radicals. Thermal aging at 90 °C for 25 days or less causes no observable change to the cross-linked polymer structure. Gamma radiation causes damage to crystalline polymer regions and introduces defects. Dielectric loss tangent is shown to be an effective and reliable nondestructive indicator of the aging severity of the filled-XLPE insulation material.

aging mechanisms↗

ACCELERATED THERMAL AGING OF HARVESTED HYPALON JACKET FOR REMAINING USEFUL LIFE DETERMINATION AND DIAGNOSIS

For nuclear power plants (NPPs) that are considering second license renewal for their operation beyond 60 years, knowledge of long-term operation, condition monitoring, and viability for the reactor components including reactor pressure vessel, concrete structures, and cable systems is essential. Such knowledge will provide NPPs with a game plan to predict performance and to estimate costs that are associated with monitoring or replacement programs for the affected systems. For cable systems that encompass a wide variety of materials, manufacturers, and in-plant location, accelerated aging of harvested cable jacket and insulation can provide insight as to remaining useful life and methods for monitoring. Accelerated thermal aging in air at temperatures between 80°C and 120°C was carried out on a multi-conductor control rod cable that had been in-service for over 30 years and was made by Boston Insulated Wire with Hypalon cable jacket and ethylene-propylene rubber insulation. From elongation at break (EAB) measurements and supporting Arrhenius analysis of the jacket material, an activation energy of 97.84 kJ/mol was estimated and the time to degradation, as represented by 50% EAB at the expected maximum operating temperature of 45°C, was estimated as consistent with 80 years. These values were slightly below previous measurements and could either be attributed to in-service degradation or variations in material properties from a given manufacturer. In addition, results from indenter modulus measurements and Fourier transform infrared spectroscopy suggest possible markers that could be beneficial to monitor cable conditions.

Glass III, Samuel W.↗

Initial Radiation of Nuclear Power Plant Components (CRADA NFE-17-06892 Final Report)

As advanced reactor concepts are developed, instrumentation and control (I&C) cables and sensors will play a significant role in assuring their operation is well understood, and safety-related process information can be collected reliably over the course of their design life. As a first step to develop acceptance criteria and define the limits of currently available nuclear I&C cable and sensor technology, a collaboration between Oak Ridge National Laboratory and Analysis and Measurement Services (AMS) Corporation was initiated under the Gateway for Accelerated Innovation in Nuclear (GAIN) Program. This collaborative effort focused on providing technical information related to the combined thermal and radiation aging of nuclear power plant (NPP) cables, companion NPP cable insulation samples, and two prototype temperature and two pressure sensors. This work was carried out using the instrumented gamma irradiation system that is part of the High Flux Isotope Reactor Gamma Irradiation Facility (HFIR GIF). This system provided the opportunity for the condition of the prototype sensors to be tracked during the irradiation in order to determine their functional limits with greater granularity when compared to a simple irradiation insertion at the HFIRGIF. Experimental assemblies for sensor irradiation were successfully completed, and sensor irradiation to accumulated dose of 3000 kGy at a rate of approximately 6 kGy/hr was carried out. Two prototype temperature assemblies were continuously monitored during exposure to 3000 kGy and found to have no observable degradation from the irradiation. Two pressure sensors were first irradiated to 1000 kGy. At which point, one of the sensors was found to operate normally; however, a second sensor failed the operability test. The operable pressure sensor output was then continuously monitored from 1000 kGy to 3000 kGy. The sensor output exhibited steady trendable drift versus the accumulated radiation dose. At the conclusion of the irradiation, the four test sensors were released for laboratory calibration checks. The calibration check of the temperature sensors found no significant change after irradiation compared to baseline measurements before irradiation; however, both pressure sensors failed the post-test calibration checks and both sensors were not functioning properly. These results will help inform sensor manufacturers and I&C design engineers of potential limitations of these types of sensors for use in high radiation environments associated with the compact configuration of new Small Modular Reactors (SMRs) such as NuScale’s reactor power module. Irradiations on NPP cables and companion samples were not completed due to programmatic delays, however a path forward that was based on lessons learned from this project was defined to accommodate future, comparable instrumented gamma irradiations at the HFIR GIF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Color Change During Thermal Degradation of Polyolefin Electric Cable Insulations

Color change of electric cable insulations used in nuclear power plants (NPPs) is a non-destructive, quick and inexpensive technique to measure degradation. Quantification of color change is facilitated by a light booth of CIE D65 illuminant, a commercial camera and open-source software ImageJ with micaToolbox plugin. Yellowness index (YI) and total color difference (?E) are calculated from calibrated photos of a white cross-linked polyethylene (XLPE) and a black ethylene-propylene rubber (EPR) based specimens aged at 110°C, 121°C, 136°C and 150°C after 1~640 days. Using the same setup and software, pixelwise ?E profile is determined for the cross-sectional photo of a white EPR specimen, where heterogeneous aging is detected.

cable aging, color analysis↗

Non-Destructive Evaluation of Polyolefin Thermal Aging Using Infrared Spectroscopy

Fourier transform infrared (FTIR) spectroscopy is an information-rich method that reveals chemical bonding near the surface of polymer composites. FTIR can be used to verify composite composition, identify chemical contaminants and expose composite moisture content. Polymer matrix changes due to thermal exposure including loss of additives, chain scission, oxidation and changes in crystallinity may also be determined using FTIR spectra. Portable handheld instruments using non-contact reflectance or surface contact attenuated total reflectance (ATR) may be used for non-destructive evaluation (NDE) of thermal aging in polymer and composite materials of in-service components. We report the use of ATR FTIR to track oxidative thermal aging in ethylene-propylene rubber (EPR) and chlorinated polyethylene (CPE) materials used in medium voltage nuclear power plant electrical cable insulation and jacketing. Mechanical property changes of the EPR and CPE materials with thermal degradation for correlation with FTIR data are tracked using indenter modulus (IM) testing. IM is often used as a local NDE metric of cable jacket health. The FTIR-determined carbonyl index was found to increase with IM and may be a valuable NDE metric with advantages over IM for assessing cable remaining useful life.

aging↗

Space Flight Qualification on a Multi-Fiber Ribbon Cable and Array Connector Assembly

NASA's Goddard Space Flight Center (GSFC) cooperatively with Sandia National Laboratories completed a series of tests on three separate configurations of multi-fiber ribbon cable and MTP connector assemblies. These tests simulate the aging process of components during launch and long-term space environmental exposure. The multi-fiber ribbon cable assembly was constructed of non-outgassing materials, with radiation-hardened, graded index 100/140-micron optical fiber. The results of this characterization presented here include vibration testing, thermal vacuum monitoring, and extended radiation exposure testing data.

Xiaodan, Linda Jin↗

LDEF fiber optic exposure experiment

Ten fiber optic cable samples of different types were exposed in low Earth orbit for over 5.5 years on the Long Duration Exposure Facility (LDEF). Four of the samples were mounted externally, and the remaining six were internal, under approximately .5 gc/sq m of aluminum. The experiment was recovered in January of 1990, and laboratory evaluation of the effects of the exposure has continued since. An increase in loss, presumed to be from radiation darkening, aging effects on polymer materials used in cabling, unique contamination effects on connector terminations, and micrometeoroid impacts were observed on some of the samples. In addition, the dependence of sample loss was measured as a function of temperature before and after the flight. All cable samples were functional, and the best exhibited no measurable change in performance, indicating that conventional fiber optic cables can perform satisfactorily in spacecraft. Experimental results obtained to date will be presented and discussed.

Johnston, Alan R.↗

LDEF fiber optic exposure experiment No. S-0109

Ten fiber optic cable samples of different types were exposed in low-earth orbit for over 5.5 years on the Long-Duration Exposure Facility (LDEF). Four of the samples were mounted externally, and the remaining six were internal, under approximately 0.5 g cm(exp -2) of aluminum. The experiment was recovered in Jan. 1990, and laboratory evaluation of the effects of the exposure has continued since. An increase in fiber loss, presumed to be from radiation darkening, aging effects on polymer materials used in cabling, unique contamination effects on connector terminations, and micrometeoroid impacts were observed. In addition, the sample loss was measured for each sample as a function of temperature before and after the flight. All cable samples were functional, and the best exhibited no measurable change in performance, indicating that conventional fiber optic cables can perform satisfactorily in spacecraft. Experimental results obtained to date are presented and discussed.

A R Johnston↗

Tracking of Nuclear Cable Insulation Polymer Structural Changes using the Gel Fraction and Uptake Factor Method

Cross-linked polyethylene (XLPE) cable insulation samples were exposed to heat and gamma radiation at a series of temperatures, dose rates, and exposure times to evaluate the effects of these variables on material degradation. The samples were tested using the solvent incubation method to collect gel fraction and uptake factor data in order to assess the crosslinking and chain scission occurring in polymer samples with aging. Consistent with previous reports, gel fraction values were observed to increase and uptake factor values to decrease with radiation and thermal exposure. The trends seen were also more prominent as exposure time increased, suggesting this to be a viable method of tracking structural changes in the XLPE-insulated cable material over extended periods. For the conditions explored, the cable insulation material evaluated did not indicate signs of anomalous aging such as inverse temperature effect in which radiation-induced aging is more severe at lower temperature. Ongoing aging under identical radiation conditions and at lower temperature will further inform conclusions regarding the importance of inverse temperature effects for this material under these conditions.

cable aging↗