Search NASA⌕ Search

SEARCH · Search NASA

Results for “cell failures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

AEA Cell-Bypass-Switch Activation: An Update

The objectives of this project included the following: (1) verify the performance of AEA cell bypass protection device (CBPD) under simulated EOS-Aqua/Aura flight hardware configuration; (2) assess the safety of the hardware under an inadvertent firing of CBPD switch, as well as the closing of CBPD; and (3) confirm that the mode of operation of CBPD switch is the formation of a continuous low impedance path (a homogeneous low melting point alloy). The nominal performance of AEA CBPD under flight operating conditions (vacuum except zero-G, and high impedance cell) has been demonstrated. There is no evidence of cell rupture or excessive heat production during or after CBPD switch activation under simulated high cell impedance (open-circuit cell failure mode). The formation of a continuous low impedance path (a homogeneous low melting point alloy) has been confirmed.

Keys, Denney↗

Curiosity's Autonomous Surface Safing Behavior Design

The safing routines on all robotic deep-space vehicles are designed to put the vehicle in a power and thermally safe configuration, enabling communication with the mission operators on Earth. Achieving this goal is made a little more difficult on Curiosity because the power requirements for the core avionics and the telecommunication equipment exceed the capability of the single power source, the Multi-Mission Radioisotope Thermoelectric Generator. This drove the system design to create an operational mode, called "sleep mode", where the vehicle turns off most of the loads in order to charge the two Li-ion batteries. The system must keep the vehicle safe from over-heat and under-heat conditions, battery cell failures, under-voltage conditions, and clock failures, both while the computer is running and while the system is sleeping. The other goal of a safing routine is to communicate. On most spacecraft, this simply involves turning on the receiver and transmitter continuously. For Curiosity, Earth is above the horizon only a part of the day for direct communication to the Earth, and the orbiter overpass opportunities only occur a few times a day. The design must robustly place the Rover in a communicable condition at the correct time. This paper discusses Curiosity's autonomous safing behavior and describes how the vehicle remains power and thermally safe while sleeping, as well as a description of how the Rover communicates with the orbiters and Earth at specific times.

MSL↗

Thermal Analysis on Large Format Lithium-Ion Batteries in Thermal Runaway

Lithium-ion (Li-ion) batteries can deliver electrical power across a large range of applications, and large format versions of these batteries are common in aerospace for their low mass and energy dense properties. Li-ion cells usage has increased as they are more power dense than fuel cells and have overall higher performance over lead-acid/NiCd batteries. However, Li-ion cells can experience Thermal Runaway (TR) via electro-chemical, mechanical, or thermal abuse. TR is a phenomenon where the stored energy in a cell is rapidly released along with vented gases and other effluents. A cell is generally determined to be in TR if its internal heat generation has surpassed its ability to dissipate that heat. If a Li-ion cell enters TR, propagation within the battery may occur. Propagation is the chain reaction that can occur to nearby cells due to a cell that has entered TR initially. Understanding a battery’s susceptiveness to propagation is necessary to evaluate risks associated with TR phenomenon. To determine if a battery is designed in a sufficient manner to prevent battery propagation if single cell TR occurs, testing and thermal analysis of the battery must be conducted. The presentation for TFAWS 2026 will cover considerations for battery TR thermal analysis, such as: testing methods, influences on the cells, failure mechanisms, and TR parameters. This presentation will include a walkthrough of an example battery TR thermal analysis, and the results thereof.

Lithium Ion Batteries↗

Microbial electrolysis cell recovery after inducing operational failure conditions

Microbial Electrolysis Cells (MECs) are often documented for their ability to produce hydrogen through new sources and new configurations. However, few studies attempt to document the recovery of the bioanode after being exposed to operational failure conditions. This study attempted to compare the behavior and recovery of MECs after being exposed to four operational failure conditions: acidification, aeration, osmotic shock, and voltage reversal. For each failure condition, three time points were tested: before failure, immediately after failure, and after recovery efforts. Of the modes tested, acidification caused the largest loss in performance and operational efficiency, while osmotic shock caused the second largest loss in performance. Aeration and voltage reversal caused negligible losses in performance immediately after failure conditions and after the recovery period. Aeration and voltage reversal had a minimal effect on the removal of individual compounds. However, acetate accumulated after acidification, and propionic acid accumulated after osmotic shock. Furthermore these findings could be useful for determining if failure will require more significant repair efforts in commercially deployed devices. While acidification created permanent losses to performance, if device failures like aeration, osmotic shock, and voltage reversal are caught early (less than 15 min), full recovery without bioanode replacement is likely.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

KOH concentration effect on the cycle life of nickel-hydrogen cells. IV - Results of failure analysis

Potassium hydroxide concentration effects on the cycle life of a Ni/H2 cell have been studied by carrying out a cycle life test on ten Ni/H2 boiler plate cells which contain electrolytes of various KOH concentrations. Failure analyses of these cells were carried out after completion of the life test, which accumulated up to 40,000 cycles at an 80-percent depth of discharge over a period of 3.7 years. These failure analyses included studies on changes of electrical characteristics of test cells, and component analyses after disassembly of the cell. The component analyses included visual inspections, dimensional changes, capacity measurements of nickel electrodes, scanning electron microscopy, surface area measurements, and chemical analyses. Results have indicated that failure mode and change in the nickel electrode varied as the concentration was varied, especially when the concentration was changed from 31 percent or higher to 26 percent or lower.

Lim, H. S.↗

Predicting Li-Ion Battery Capacity Fade Using Early-Life Data and a Hybrid Data-Driven Gaussian Process-Bayesian Regression Approach

Accurately predicting Li-ion battery capacity trajectories using early-life data can dramatically improve battery-life understandings and be used to rapidly evaluate design/cost/performance trade-offs when developing new battery materials. Accurate early-life predictions enable researchers to quickly iterate over cell designs and material precursor properties without consistently cycling cells to failure. To this end, we present a toolbox that uses a combined Gaussian Process and Bayesian regression approach that capitalizes on signals other than just capacity (e.g., dQ/dV, voltage drops) to rapidly predict capacity-fade trajectories. The prediction tool uses Bayesian regression to fit functional forms, e.g., power law, sigmoids, etc., to predict capacity-fade dynamics. By fitting functional forms, the capacity fade can be interrogated at any point in the future, allowing for early cell-failure prediction. Additionally, Bayesian regression allows for accurate uncertainty estimates that account for cell-to-cell variability (aleatoric uncertainty) and the lack of observation data (epistemic uncertainty). By only using early cycle data to predict the capacity fade trajectory, uncertainty bounds at end-of-life can be extremely large. The large uncertainty bounds are further exacerbated because there is no systematic way to define the prior distribution of the functional forms' parameters. We improve our the predicted trajectory confidence interval of our predicted trajectory using two methods. First, we shows that a small amount of held-out cycling data is sufficientuse some train cells, that have been cycled to failure to derive information regarding the appropriate prior distributions for the functional forms' parameters of the functional form, effectively leading to data-driven priors.. We propose constructing the data-driven priors by first running a Bayesian regression starting with uninformed priors to generate intermediate cell-specific posterior parameter distributions. These posterior distributions are combined using a Ggaussian mixture model for each parameter to create the data-driven priors. These mixture models serve as the data-driven prior distributions for the parameters for. Second, we derive multiple features, e.g., C_dchg 0.5 DoD 0.5, log (|mean(dQ/dV_(w_3-w_0 ) (V)|), etc., from the train cellsheld-out cycling data, identify which the features are that best predicting capacity at early/mid-life cycles, and then create Ggaussian process regression models that are used for predicting capacity at early/mid-life cycles for the test cells (see blue dots with error bars in Fig 1b). Finally, these predicted data-points are used in addition to the actual early cycle data capacity fade to construct the Bayesian regression trajectory for the test cell s. Notably. We note that these two methods are complementary and can be combined with each other. We evaluate the performance of our proposed method on an testing open-source dataset from Iowa State University and Iowa Lakes Community College (ISU-ILCC). This dataset comprises of 251 nickel-manganese-cobalt/graphite Lithium-ion cells that are cycled under 63 different conditions. We compute the mean average percentage error (MAPE) and negative log predictive density (NLPD) to quantify the efficacy of our method. Our initial findings suggest that, when only few observations are available, for test cells, when using only Bayesian regression with uninformed priors, a power law functional provides the most accurate predictions. with very few data points. However, asHowever, a the number of data points increases, a twin sigmoidal function becomes more accurate as the number of observations further increases. We also find that using as little as 10% of the data set towards generating data-driven priors can lead to significant improvement in prediction accuracy when using early cycle data. Lastly, we found that augmenting early-cycle data with Gaussian process-predicted capacity data for Bayesian regression greatly improves the prediction accuracy. We will present a comprehensive comparison of our methods to other methods available in the literature and apply this method to additional battery datasets.

42 ENGINEERING↗

Cycle life test and failure model of nickel-hydrogen cells

Six ampere hour individual pressure vessel nickel hydrogen cells were charge/discharge cycled to failure. Failure as used here is defined to occur when the end of discharge voltage degraded to 0.9 volts. They were cycled under a low earth orbit cycle regime to a deep depth of discharge (80 percent of rated ampere hour capacity). Both cell designs were fabricated by the same manufacturer and represent current state of the art. A failure model was advanced which suggests both cell designs have inadequate volume tolerance characteristics. The limited existing data base at a deep depth of discharge (DOD) was expanded. Two cells of each design were cycled. One COMSAT cell failed at cycle 1712 and the other failed at cycle 1875. For the Air Force/Hughes cells, one cell failed at cycle 2250 and the other failed at cycle 2638. All cells, of both designs, failed due to low end of discharge voltage (0.9 volts). No cell failed due to electrical shorts. After cell failure, three different reconditioning tests (deep discharge, physical reorientation, and open circuit voltage stand) were conducted on all cells of each design. A fourth reconditioning test (electrolyte addition) was conducted on one cell of each design. In addition post cycle cell teardown and failure analysis were performed on the one cell of each design which did not have electrolyte added after failure.

Smithrick, J. J.↗

Cycle life test and failure model of nickel-hydrogen cells

Six ampere hour individual pressure vessel nickel hydrogen cells were charge/discharge cycled to failure. Failure as used here is defined to occur when the end of discharge voltage degraded to 0.9 volts. They were cycled under a low earth orbit cycle regime to a deep depth of discharge (80 percent of rated ampere hour capacity). Both cell designs were fabricated by the same manufacturer and represent current state of the art. A failure model was advanced which suggests both cell designs have inadequate volume tolerance characteristics. The limited existing data base at a deep depth of discharge (DOD) was expanded. Two cells of each design were cycled. One COMSAT cell failed at cycle 1712 and the other failed at cycle 1875. For the Air Force/Hughes cells, one cell failed at cycle 2250 and the other failed at cycle 2638. All cells, of both designs, failed due to low end of discharge voltage (0.9 volts). No cell failed due to electrical shorts. After cell failure, three different reconditioning tests (deep discharge, physical reorientation, and open circuit voltage stand) were conducted on all cells of each design. A fourth reconditioning test (electrolyte addition) was conducted on one cell of each design. In addition post cycle cell teardown and failure analysis were performed on the one cell of each design which did not have electrolyte added after failure. Previously announced in STAR as N83-25038

Smithrick, J. J.↗

Evolution and Degradation Patterns of Electrochemical Cells Based on the Analysis of Interfacial Phenomena at Li Metal Anode/Electrolyte Interfaces

In this work, we report the results of a theoretical–computational analysis of the solid electrolyte interphase (SEI) growth and degradation dynamics occurring in lithium metal batteries during cycling. We use ab initio-kinetic Monte Carlo simulations to generate a synthetic data set, which is analyzed by machine learning methods. We aim to determine: (i) how modifications in interfacial interaction energies between solid electrolyte interphase (SEI) blocks and between Li ions and SEI facets impact the Coulombic efficiency (CE) of the battery and (ii) what factors, including reactions, microscopic transport, and other interfacial events, may lead to cell performance “failure” during prolonged charge and discharge cycles, signaled as a sharp decay in the CE over cycling. The demonstration of our approach is done on a cell including a Li metal surface interfacing with a previously introduced state-of-the-art electrolyte, and the idea can be applied to any electrochemical system. Outcomes include the identification of the leading chemical, physical, and structural variables causing cell failure and relating them to the electrolyte formulation, thus paving the way to future more refined analysis and electrolyte design.

batteries↗

KOH concentration effect on the cycle life of nickel-hydrogen cells. 4: Results of failure analyse

Effects of KOH concentrations on failure modes and mechanisms of nickel-hydrogen cells were studied using long cycled boiler plate cells containing electrolytes of various KOH concentrations ranging 21 to 36 percent. Life of these cells were up to 40,000 cycles in an accelerated low earth orbit (LEO) cycle regime at 80 percent depth of discharge. An interim life test results were reported earlier in J. Power Sources, 22, 213-220, 1988. The results of final life test, end-of-life cell performance, and teardown analyses are discussed. These teardown analyses included visual observations, measurements of nickel electrode capacity in an electrolyte-flooded cell, dimensional changes of cell components, SEM studies on cell cross section, BET surface area and pore volume distribution in cycled nickel electrodes, and chemical analyses. Cycle life of a nickel-hydrogen cell was improved tremendously as KOH concentration was decreased from 36 to 31 percent and from 31 to 26 percent while effect of further concentration decrease was complicated as described in our earlier report. Failure mode of high concentration (31 to 36 percent) cells was gradual capacity decrease, while that of low concentration (21 to 26 percent) cells was mainly formation of a soft short. Long cycled (25,000 to 40,000 cycles) nickel electrodes were expanded more than 50 percent of the initial value, but no correlation was found between this expansion and measured capacity. All electrodes cycled in low concentration (21 to 26 percent) cells had higher capacity than those cycled in high concentration (31 to 36 percent) cells.

Lim, H. S.↗

Chiral-structured heterointerfaces enable durable perovskite solar cells

Mechanical failure and chemical degradation of device heterointerfaces can strongly influence the long-term stability of perovskite solar cells (PSCs) under thermal cycling and damp heat conditions. Here, we report chirality-mediated interfaces based on R-/S-methylbenzyl-ammonium between the perovskite absorber and electron-transport layer to create an elastic yet strong heterointerface with increased mechanical reliability. This interface harnesses enantiomer-controlled entropy to enhance tolerance to thermal cycling–induced fatigue and material degradation, and a heterochiral arrangement of organic cations leads to closer packing of benzene rings, which enhances chemical stability and charge transfer. The encapsulated PSCs showed retentions of 92% of power-conversion efficiency under a thermal cycling test (-40°C to 85°C; 200 cycles over 1200 hours) and 92% under a damp heat test (85% relative humidity; 85°C; 600 hours).

14 SOLAR ENERGY↗

Captopril to Mitigate Chronic Renal Failure After Hematopoietic Stem Cell Transplantation: A Randomized Controlled Trial

Purpose: To test whether the angiotensin-converting enzyme inhibitor captopril was effective in mitigating chronic renal failure after hematopoietic stem cell transplantation (HSCT). Methods and Materials: A total of 55 subjects undergoing total body irradiation (TBI)-HSCT were enrolled in this randomized controlled trial. Captopril or identical placebo was started at engraftment and continued as tolerated until 1 year after HSCT. Results: The baseline serum creatinine and calculated glomerular filtration rate (GFR) did not differ between groups. The 1-year serum creatinine level was lower and the GFR higher in the captopril compared with the placebo group (p = 0.07 for GFR). Patient survival was higher in the captopril compared with the placebo group, but this was also not statistically significant (p = 0.09). In study subjects who received the study drug for more than 2 months, the 1-year calculated GFRs were 92 mL/min and 80 mL/min, for the captopril and placebo groups, respectively (p = 0.1). There was no adverse effect on hematologic outcome. Conclusions: There is a trend in favor of captopril in mitigation of chronic renal failure after radiation-based HSCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiscale Failure Analysis of a 3D Woven Unit Cell Containing Defects

Multiscale failure simulations have been performed for a Three-dimensional woven composite unit cell considering five, or more, length scales spanning the woven composite mesoscale to the sub-microscale voids. The multiscale recursive micromechanics approach, which enables recursive integration of general micromechanics theories over an arbitrary number of length scales, has been employed within the NASA Multiscale Analysis Tool. The multiscale model uses both the generalized method of cells and Mori-Tanaka micromechanics theories, and considers failure in the constituent materials using a simple damage model. Baseline results, containing distributed voids, are compared to uniaxial experimental data for an AS4 carbon fiber/ RTM6 epoxy matrix 3D orthogonal woven composite with good agreement in terms of global stiffness and global failure stress. The simulations demonstrate that the 3D woven composite exhibits damage tolerance through sustaining increasing axial load far beyond the first initiation of damage. The multiscale model is used to examine the nonlinear response of the material to other loading conditions. Case studies, motivated by X-ray computed tomography data, are presented on the effects of manufacturing induced voids and cracks.

3D woven↗

Nongassing nickel-cadmium battery electrodes and cells

The failure of nickel-cadmium storage batteries due to severe gassing during charging is discussed. In order to increase the life of such cells, nongassing positive and negative electrodes are used. The gassing characteristics of nickel electrodes were evaluated as a function of their loading, charge rate, and charge temperature.

Luksha, E.↗

KOH concentration effect on the cycle life of nickel-hydrogen cells. Part 4: Results of failure analyses

KOH concentration effects on cycle life of a Ni/H2 cell have been studied by carrying out a cycle life test of ten Ni/H2 boiler plate cells which contain electrolytes of various KOH concentrations. Failure analyses of these cells were carried out after completion of the life test which accumulated up to 40,000 cycles at an 80 percent depth of discharge over a period of 3.7 years. These failure analyses included studies on changes of electrical characteristics of test cells and component analyses after disassembly of the cell. The component analyses included visual inspections, dimensional changes, capacity measurements of nickel electrodes, scanning electron microscopy, BET surface area measurements, and chemical analyses. Results have indicated that failure mode and change in the nickel electrode varied as the concentration was varied, especially, when the concentration was changed from 31 percent or higher to 26 percent or lower.

Lim, H. S.↗

Failure analysis of thin-film amorphous-silicon solar-cell modules

A failure analysis of thin film amorphous silicon solar cell modules was conducted. The purpose of this analysis is to provide information and data for appropriate corrective action that could result in improvements in product quality and reliability. Existing techniques were expanded in order to evaluate and characterize degradational performance of a-Si solar cells. Microscopic and macroscopic defects and flaws that significantly contribute to performance degradation were investigated.

Kim, Q.↗

Intensity-Modulated Radiotherapy for Oral Cavity Squamous Cell Carcinoma: Patterns of Failure and Predictors of Local Control

Purpose: Few studies have evaluated the use of intensity-modulated radiotherapy (IMRT) for squamous cell carcinoma (SCC) of the oral cavity (OC). We report clinical outcomes and failure patterns for these patients. Methods and Materials: Between October 2002 and June 2009, 37 patients with newly diagnosed SCC of the OC underwent postoperative (30) or definitive (7) IMRT. Twenty-five patients (66%) received systemic therapy. The median follow-up was 38 months (range, 10-87 months). The median interval from surgery to RT was 5.9 weeks (range, 2.1-10.7 weeks). Results: Thirteen patients experienced local-regional failure at a median of 8.1 months (range, 2.4-31.9 months), and 2 additional patients experienced local recurrence between surgery and RT. Seven local failures occurred in-field (one with simultaneous nodal and distant disease) and two at the margin. Four regional failures occurred, two in-field and two out-of-field, one with synchronous metastases. Six patients experienced distant failure. The 3-year actuarial estimates of local control, local-regional control, freedom from distant metastasis, and overall survival were 67%, 53%, 81%, and 60% among postoperative patients, respectively, and 60%, 60%, 71%, and 57% among definitive patients. Four patients developed Grade {>=}2 chronic toxicity. Increased surgery to RT interval predicted for decreased LRC (p = 0.04). Conclusions: Local-regional control for SCC of the OC treated with IMRT with or without surgery remains unsatisfactory. Definitive and postoperative IMRT have favorable toxicity profiles. A surgery-to-RT interval of <6 weeks improves local-regional control. The predominant failure pattern was local, suggesting that both improvements in target delineation and radiosensitization and/or dose escalation are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗