SEARCH · Search NASA
Results for “cell imaging”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Image registration for accurate electrode deformation analysis in operando microscopy of battery materials
Operando imaging techniques have become increasingly valuable in both battery research and manufacturing. However, the reliability of these methods can be compromised by instabilities in the imaging setup and operando cells, particularly when utilizing high-resolution imaging systems. The acquired imaging data often include features arising from both undesirable system vibrations and drift, as well as the scientifically relevant deformations occurring in the battery sample during cell operation. For meaningful analysis, it is crucial to distinguish and separately evaluate these two factors. To address these challenges, we employ a suite of advanced image-processing techniques. These include fast Fourier transform analysis in the frequency domain, power spectrum-based assessments for image quality, as well as rigid and non-rigid image-registration methods. These techniques allow us to identify and exclude blurred images, correct for displacements caused by motor vibrations and sample holder drift and, thus, prevent unwanted image artifacts from affecting subsequent analyses and interpretations. Additionally, we apply optical flow analysis to track the dynamic deformation of battery electrode materials during electrochemical cycling. This enables us to observe and quantify the evolving mechanical responses of the electrodes, offering deeper insights into battery degradation. Together, these methods ensure more accurate image analysis and enhance our understanding of the chemomechanical interplay in battery performance and longevity.
Methods—Kintsugi Imaging of Battery Electrodes: Distinguishing Pores from the Carbon Binder Domain using Pt Deposition
The mesostructure of porous electrodes used in lithium-ion batteries strongly influences cell performance. Accurate imaging of the distribution of phases in these electrodes would allow this relationship to be better understood through simulation. However, imaging the nanoscale features in these components is challenging. While scanning electron microscopy is able to achieve the required resolution, it has well established difficulties imaging porous media. This is because the flat imaging planes prepared using focused ion beam milling will intersect with the pores, which makes the images hard to interpret as the inside walls of the pores are observed. It is common to infiltrate porous media with resin prior to imaging to help resolve this issue, but both the nanoscale porosity and the chemical similarity of the resins to the battery materials undermine the utility of this approach for most electrodes. In this study, a technique is demonstrated which uses in situ infiltration of platinum to fill the pores and thus enhance their contrast during imaging. Reminiscent of the Japanese art of repairing cracked ceramics with precious metals, this technique is referred to as the kintsugi method. The images resulting from applying this technique to a conventional porous cathode are presented and then segmented using a multi-channel convolutional method. We show that while some cracks in active material particles were empty, others appear to be filled (perhaps with the carbon binder phase), which will have implications for the rate performance of the cell. Energy dispersive X-ray spectroscopy was used to validate the distribution of phases resulting from image analysis, which also suggested a graded distribution of the binder relative to the carbon additive. The equipment required to use the kintsugi method is commonly available in major research facilities and so we hope that this method will be rapidly adopted to improve the imaging of electrode materials and porous media in general.
Auxin‐induced actin cytoskeleton rearrangements require AUX1
Summary The actin cytoskeleton is required for cell expansion and implicated in cellular responses to the phytohormone auxin. However, the mechanisms that coordinate auxin signaling, cytoskeletal remodeling and cell expansion are poorly understood. Previous studies examined long‐term actin cytoskeleton responses to auxin, but plants respond to auxin within minutes. Before this work, an extracellular auxin receptor – rather than the auxin transporter AUXIN RESISTANT 1 (AUX1) – was considered to precede auxin‐induced cytoskeleton reorganization. In order to correlate actin array organization and dynamics with degree of cell expansion, quantitative imaging tools established baseline actin organization and illuminated individual filament behaviors in root epidermal cells under control conditions and after indole‐3‐acetic acid (IAA) application. We evaluated aux1 mutant actin organization responses to IAA and the membrane‐permeable auxin 1‐naphthylacetic acid (NAA). Cell length predicted actin organization and dynamics in control roots; short‐term IAA treatments stimulated denser and more parallel, longitudinal arrays by inducing filament unbundling within minutes. Although AUX1 is necessary for full actin rearrangements in response to auxin, cytoplasmic auxin (i.e. NAA) stimulated a lesser response. Actin filaments became more ‘organized’ after IAA stopped elongation, refuting the hypothesis that ‘more organized’ actin arrays universally correlate with rapid growth. Short‐term actin cytoskeleton response to auxin requires AUX1 and/or cytoplasmic auxin.
Hg Accumulation by Single-Cell Sulfate-Reducing Bacteria Methylating Mercury
Methylmercury (MeHg) is a potent neurotoxin that poses risks to ecosystems and human health. MeHg is produced by microbes following saturating-like kinetics. We hypothesize that this saturation reflects a limited intracellular mercury (Hg) accumulation. Here, in this study, we investigated Hg accumulation in Pseudodesulfovibrio hydrargyri BerOc1, a sulfate-reducing model strain able to methylate Hg. Cells were incubated with 0.5 and 2 μM of mercury (HgCl 2 ), and mercury localization was studied using synchrotron-based nano-X-ray fluorescence and high-resolution analytical electron microscopy. For both concentrations, Hg was detected in the bacterial cytosol, in addition to extracellular (Hg, S)-containing nanoparticles. Intracellular Hg levels were slightly higher at 2 μM than at 0.5 μM (1.61 vs 1.40 pg.mm –2 ), suggesting a regulated accumulation. However, the population exhibited heterogeneity in Hg accumulation, particularly at the highest Hg exposure, with some cells being Hg hyperaccumulators. Correlative imaging between Hg localization and cell viability revealed that these hyperaccumulating cells were non-active. Our results suggest that active cells regulate Hg accumulation. From an analytical perspective, a minor subpopulation of hyperaccumulating cells can bias bulk measurements and should be considered in interpreting Hg accumulation in microorganisms. Environmentally, these cells can impact Hg cycling by acting as a metal sink.
Video-rate Raman-based metabolic imaging by Airy light-sheet illumination and photon-sparse detection
Despite its massive potential, Raman imaging represents just a modest fraction of all research and clinical microscopy to date. This is due to the ultralow Raman scattering cross-sections of most biomolecules that impose low-light or photon-sparse conditions. Bioimaging under such conditions is suboptimal, as it either results in ultralow frame rates or requires increased levels of irradiance. Here, we overcome this tradeoff by introducing Raman imaging that operates at both video rates and 1,000-fold lower irradiance than state-of-the-art methods. To accomplish this, we deployed a judicially designed Airy light-sheet microscope to efficiently image large specimen regions. Further, we implemented subphoton per pixel image acquisition and reconstruction to confront issues arising from photon sparsity at just millisecond integrations. We demonstrate the versatility of our approach by imaging a variety of samples, including the three-dimensional (3D) metabolic activity of single microbial cells and the underlying cell-to-cell variability. To image such small-scale targets, we again harnessed photon sparsity to increase magnification without a field-of-view penalty, thus, overcoming another key limitation in modern light-sheet microscopy.
Cell dark current–voltage from non-calibrated module electroluminescence image analysis
Here, we present a fast, accurate, and reliable method of obtaining cell dark current–voltage (I–V) curves from module electroluminescence (EL) images without requiring calibration or correction. For a pristine module, EL-derived dark I–V are compared to directly probed data for a variety of changing imaging parameters: camera sensor, lens, filter, aperture width, exposure time (level of sensor saturation), number of images used, and various combinations of these. Pristine modules and those experiencing different modes and degrees of degradation are examined. A recent study of modules using five different cell technologies demonstrates the practicality of our “EL sweep” technique for performance and degradation studies.
Precision Labeling of Native Antibodies with Lock Coupling
The formation of stable protein complexes enables much of biotechnology, but even high-affinity complexes can dissociate, limiting potential applications in biomaterials, bioimaging, nanomedicine, and other protein-based technologies. Here, in this study, we describe lock coupling, a simple and selective one-step reaction between interfacial lysine and glutamate or aspartate side chains to form stable isopeptide bonds and be used for the precise labeling of native antibodies. We identify conditions in which short-lived activated esters formed by the aqueous carbodiimide EDC promote isopeptide bond formation specifically at preassociated amine-acid pairs. Indiscriminate cross-linking is minimized by formation of protein complexes before addition of catalyst, use of acidic pH to suppress exposed Lys reactivity, and limiting the aqueous stability of activated esters. For native antibody (Ab) labeling, we show that the small IgG-binding protein GB1 can be covalently attached to the Ab Fc domain and that introduction of Cys into GB1 loops allows for facile conjugation of fluorophores, micelles, or inorganic nanocrystals for imaging in live cells and animals. By varying Cys substituents and protein stoichiometry, a defined number of probes can be uniformly attached without the need for extensive purification. In live-cell confocal microscopy, labeled GB1 serves as a stable replacement for secondary Abs, enabling simple multicolor immunostaining and imaging. Lock coupling requires just a single reagent in aqueous buffer and leverages both the innate ability of proteins to form high-affinity complexes and the widespread presence of Lys-Glu/Asp pairs at their interfaces, with the potential for precision synthesis of protein-based probes for imaging, biomaterials, biophysics, and medicine.
Soft X-ray tomography reveals variations in B. subtilis biofilm structure upon tasA deletion
Bacterial biofilms are complex cell communities within a self-produced extracellular matrix, crucial in various fields but challenging to analyze in 3D. We developed a "biofilm-in-capillary" growth method compatible with full-rotation soft X-ray tomography, enabling high-resolution 3D imaging of bacterial cells and their matrix during biofilm formation. This approach offers 50 nm isotropic spatial resolution, rapid imaging, and quantitative native analysis of biofilm structure. Using Bacillus subtilis biofilms, we detected coherent alignment and chaining of wild-type cells towards the oxygen-rich capillary tip. In contrast, the ΔtasA genetic knock-out showed a loss of cellular orientation and changes in the extracellular matrix. Adding TasA protein to the ΔtasA strain restored matrix density and led to cell assembly compaction, but without the chaining observed in wild-type biofilms. This scalable and transferable approach opens new avenues for examining biofilm structure and function across various species, including mixed biofilms, and response to genetic and environmental factors.
Excitation spectral microscopy for highly multiplexed fluorescence imaging and quantitative biosensing
The multiplexing capability of fluorescence microscopy is severely limited by the broad fluorescence spectral width. Spectral imaging offers potential solutions, yet typical approaches to disperse the local emission spectra notably impede the attainable throughput. Here we show that using a single, fixed fluorescence emission detection band, through frame-synchronized fast scanning of the excitation wavelength from a white lamp via an acousto-optic tunable filter, up to six subcellular targets, labeled by common fluorophores of substantial spectral overlap, can be simultaneously imaged in live cells with low (~1%) crosstalks and high temporal resolutions (down to ~10 ms). The demonstrated capability to quantify the abundances of different fluorophores in the same sample through unmixing the excitation spectra next enables us to devise novel, quantitative imaging schemes for both bi-state and Förster resonance energy transfer fluorescent biosensors in live cells. We thus achieve high sensitivities and spatiotemporal resolutions in quantifying the mitochondrial matrix pH and intracellular macromolecular crowding, and further demonstrate, for the first time, the multiplexing of absolute pH imaging with three additional target organelles/proteins to elucidate the complex, Parkin-mediated mitophagy pathway. Together, excitation spectral microscopy provides exceptional opportunities for highly multiplexed fluorescence imaging. The prospect of acquiring fast spectral images without the need for fluorescence dispersion or care for the spectral response of the detector offers tremendous potential.
X-ray Fluorescence Microscopy to Develop Elemental Classifiers and Investigate Elemental Signatures in BALB/c Mouse Intestine a Week after Exposure to 8 Gy of Gamma Rays
Iron redistribution in the intestine after total body irradiation is an established phenomenon. However, in the literature, there are no reports about the use of X-ray fluorescence microscopy or equivalent techniques to generate semi-quantitative 2D maps of iron in sectioned intestine samples from irradiated mice. In this work, we used X-ray fluorescence microscopy (XFM) to map the elemental content of iron as well as phosphorus, sulfur, calcium, copper and zinc in tissue sections of the small intestine from eight-week-old BALB/c male mice that developed gastrointestinal acute radiation syndrome (GI-ARS) in response to exposure to 8 Gray of gamma rays. Seven days after irradiation, we found that the majority of the iron is localized as hot spots in the intercellular regions of the area surrounding crypts and stretching between the outer perimeter of the intestine and the surface cell layer of villi. In addition, this study represents our current efforts to develop elemental cell classifiers that could be used for the automated generation of regions of interest for analyses of X-ray fluorescence maps. Once developed, such a tool will be instrumental for studies of effects of radiation and other toxicants on the elemental content in cells and tissues. While XFM studies cannot be conducted on living organisms, it is possible to envision future scenarios where XFM imaging of single cells sloughed from the human (or rodent) intestine could be used to follow up on the progression of GI-ARS.
Colorectal Cancer Metastases in the Liver Establish Immunosuppressive Spatial Networking between Tumor-Associated SPP1 + Macrophages and Fibroblasts
Abstract Purpose: The liver is the most frequent metastatic site for colorectal cancer. Its microenvironment is modified to provide a niche that is conducive for colorectal cancer cell growth. This study focused on characterizing the cellular changes in the metastatic colorectal cancer (mCRC) liver tumor microenvironment (TME). Experimental Design: We analyzed a series of microsatellite stable (MSS) mCRCs to the liver, paired normal liver tissue, and peripheral blood mononuclear cells using single-cell RNA sequencing (scRNA-seq). We validated our findings using multiplexed spatial imaging and bulk gene expression with cell deconvolution. Results: We identified TME-specific SPP1-expressing macrophages with altered metabolism features, foam cell characteristics, and increased activity in extracellular matrix (ECM) organization. SPP1+ macrophages and fibroblasts expressed complementary ligand–receptor pairs with the potential to mutually influence their gene-expression programs. TME lacked dysfunctional CD8 T cells and contained regulatory T cells, indicative of immunosuppression. Spatial imaging validated these cell states in the TME. Moreover, TME macrophages and fibroblasts had close spatial proximity, which is a requirement for intercellular communication and networking. In an independent cohort of mCRCs in the liver, we confirmed the presence of SPP1+ macrophages and fibroblasts using gene-expression data. An increased proportion of TME fibroblasts was associated with the worst prognosis in these patients. Conclusions: We demonstrated that mCRC in the liver is characterized by transcriptional alterations of macrophages in the TME. Intercellular networking between macrophages and fibroblasts supports colorectal cancer growth in the immunosuppressed metastatic niche in the liver. These features can be used to target immune-checkpoint–resistant MSS tumors.
Molecular-resolution imaging of ice crystallized from liquid water by cryogenic liquid-cell TEM
Despite the ubiquity of ice, a molecular-resolution image of nanoscopic defects or microstructures in ice crystallized from liquid water has never been obtained. This is mainly due to the difficulties in preparing and preserving crystalline ice samples that can survive under high-resolution imaging conditions. Here, we report the stabilization and Å-resolution electron imaging of ice Ih crystallized from liquid water by developing cryogenic liquid-cell transmission electron microscopy (CRYOLIC-TEM). We combine lattice mapping with molecular dynamics simulations to reveal that ice formation is highly tolerant to nanoscale defects such as misoriented subdomains and trapped gas bubbles, which are stabilized by molecular-scale structural motifs. Importantly, bubble surfaces adopt low-energy nanofacets and create negligible strain fields in the surrounding crystal. These bubbles can dynamically nucleate, grow, migrate, dissolve, and coalesce under electron irradiation and be monitored in situ near a steady state. This work improves our understanding of water crystallization behaviors at a molecular spatial resolution.
Simultaneous imaging and diffraction in the dynamic diamond anvil cell
The ability to visualize a sample undergoing a pressure-induced phase transition allows for the determination of kinetic parameters, such as the nucleation and growth rates of the high-pressure phase. For samples that are opaque to visible light (such as metallic systems), it is necessary to rely on x-ray imaging methods for sample visualization. Here, we present an experimental platform developed at beamline P02.2 at the PETRA III synchrotron radiation source, which is capable of performing simultaneous x-ray imaging and diffraction of samples that are dynamically compressed in piezo-driven diamond anvil cells. This setup utilizes a partially coherent monochromatic x-ray beam to perform lensless phase contrast imaging, which can be carried out using either a parallel- or focused-beam configuration. The capabilities of this platform are illustrated by experiments on dynamically compressed Ga and Ar. Melting and solidification were identified based on the observation of solid/liquid phase boundaries in the x-ray images and corresponding changes in the x-ray diffraction patterns collected during the transition, with significant edge enhancement observed in the x-ray images collected using the focused-beam. These results highlight the suitability of this technique for a variety of purposes, including melt curve determination.
In-Cell Deployment and First Use of Digital Image Correlation for In-Situ Strain Analysis of Irradiated Nuclear Fuel Rods During LOCA Transient
Digital image correlation (DIC) is a noncontact, optical method increasingly used across industries and research environments for acquiring multidimensional strain data. At Oak Ridge National Laboratory’s (ORNL’s) Severe Accident Test Station (SATS), DIC has been extensively applied to study the thermomechanical response of nuclear fuel claddings, yielding fundamental insights into material behavior. However, these efforts have focused exclusively on unirradiated materials and relied on the SATS out-of-cell infrastructure. Efforts over the past two years have been made to extend these capabilities to ORNL’s Irradiated Fuels Examination Laboratory SATS system within the hot-cells to enable testing of irradiated fuel cladding materials. Integrating DIC into the hot-cell SATS infrastructure presents unique challenges, including enabling remote operation of optical equipment and adapting auxiliary hot-cell systems for DIC implementation. This report discusses design, stand-up testing, and application of DIC to an irradiated nuclear fuel cladding segment. A DIC testing rig was successfully built and validated out-of-cell through extensive surrogate tests and calibrations. The rig and specialized DIC furnace were installed in the hot-cell, and a DIC test was successfully conducted. Results from that test correspond to expectations for Zr-based alloys and showed similar uncertainties compared to out-of-cell tests.
Distinguishing Potassium Channel Resting State Conformations in Live Cells with Environment-Sensitive Fluorescence
Ion channels are polymorphic membrane proteins whose high-resolution structures offer images of individual conformations, giving us starting points for identifying the complex and transient allosteric changes that give rise to channel physiology. Here, we report live-cell imaging of voltage-dependent structural changes of voltage-gated Kv2.1 channels using peptidyl tarantula toxins labeled with an environment-sensitive fluorophore, whose spectral shifts enable identification of voltage-dependent conformation changes in the resting voltage sensing domain (VSD) of the channel. We synthesize a new environment-sensitive, far-red fluorophore, julolidine phenoxazone (JP) azide, and conjugate it to tarantula toxin GxTX to characterize Kv2.1 VSD allostery during membrane depolarization. JP has an inherent response to the polarity of its immediate surroundings, offering site-specific structural insight into each channel conformation. Using voltage-clamp spectroscopy to collect emission spectra as a function of membrane potential, we find that they vary with toxin labeling site, the presence of Kv2 channels, and changes in membrane potential. With a high-affinity conjugate in which the fluorophore itself interacts closely with the channel, the emission shift midpoint is 50 mV more negative than the Kv2.1 gating current midpoint. This suggests that substantial conformational changes at the toxin-channel interface are associated with early gating charge transitions and these are not concerted with VSD motions at more depolarized potentials. These fluorescent probes enable study of conformational changes that can be correlated with electrophysiology, putting channel structures and models into a context of live-cell membranes and physiological states.
Switchable resolution in soft x-ray tomography of single cells
The diversity of living cells, in both size and internal complexity, calls for imaging methods with adaptable spatial resolution. Soft x-ray tomography (SXT) is a three-dimensional imaging technique ideally suited to visualizing and quantifying the internal organization of single cells of varying sizes in a near-native state. The achievable resolution of the soft x-ray microscope is largely determined by the objective lens, but switching between objectives is extremely time-consuming and typically undertaken only during microscope maintenance procedures. Since the resolution of the optic is inversely proportional to the depth of focus, an optic capable of imaging the thickest cells is routinely selected. This unnecessarily limits the achievable resolution in smaller cells and eliminates the ability to obtain high-resolution images of regions of interest in larger cells. Here, we describe developments to overcome this shortfall and allow selection of microscope optics best suited to the specimen characteristics and data requirements. We demonstrate that switchable objective capability advances the flexibility of SXT to enable imaging cells ranging in size from bacteria to yeast and mammalian cells without physically modifying the microscope, and we demonstrate the use of this technology to image the same specimen with both optics.