Search NASA⌕ Search

SEARCH · Search NASA

Results for “centrifugal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Assessing high fidelity multi-component models to facilitate safeguards at Gas Centrifuge Enrichment Plants

We report that the International Atomic Energy Agency (IAEA) inspectors routinely carry out environmental sampling (ES) as a verification method. Collection of environmental swipe samples at various locations in Gas Centrifuge Enrichment Facilities (GCEPs) is an important process in detecting misuse of a declared facility and possibly the existence of undeclared nuclear material. These samples are measured for isotopic composition in uranium containing particles by Thermal Ionization Mass Spectrometry (TIMS) or Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Even though ES is highly effective in detecting the absolute value of enrichments and their deviations from the declared values, it cannot explain the cause of those changes. Several potential explanations can serve as possibilities for particles detected above or other than the declared enrichment. These include normal and non-malicious events such as the design of the enrichment cascades, unintentional failures of the machines, or overshoot during startup of a cascade. It can also be the result of deliberate misuse by the facility operators. The primary objective of this work is to understand how these factors affect the enrichments produced by a cascade and quantify anticipated multi-isotopic concentrations for each case. The following methodology is employed to determine signatures at a particular facility. 1) Utilize a new two-dimensional multi-component diffusion code to obtain centrifuge performance data and use that information to design and perform cascade analysis. Compare and contrast the results with previous 1-D radially averaged solutions from the Pancake code. 2) Design a GCEP cascade with the production goal of 19.75% 235 U for each set of machine data above. Investigate two cascade scenarios that include enrichment of natural uranium (NU) feed to 19.75% 235U in a single cascade compared to a two-step process of NU to 5% and then 5% to 19.75%. 3) Simulate the intentional vs. unintentional off-normal scenarios in the cascades to assess the differences in isotopic concentrations. A non-ideal squared-off cascade model developed at the University of Virginia is used to calculate flow rates and isotopic concentrations of the process gas. The analysis is performed using the Rome machine model operated at 600 m/s rotor speed. The upper and lower bounds of normal and abnormal enrichments in a typical facility are used in conjunction with ES results to understand the root causes of such observations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Continuous-Flow Centrifugal Solid/Liquid Separation for the Recovery of Rare-Earth Elements Containing Particles from Phosphoric Acid Sludge

Phosphoric acid sludge contains acid (~54% P 2 O 5 ) and solid precipitates including rare earth elements (REEs) at concentrations of ~2200 ppm. Low-cost recovery of valuable P 2 O 5 and simultaneous solid separation could be an economically feasible approach to recovering REEs while increasing the production of phosphoric acid. The sludge, however, is a complicated stream that cannot be separated by traditional technologies because of high viscosity and a large solid content (30–40%). Guided by a force balance model, an efficient solid/liquid separation method is demonstrated, using a continuous-flow centrifugal contactor. Additionally, the shear regime is bypassed by introducing the sludge directly into the rotor where a centrifugal force is exerted on the fluid, inducing phase separation. Solid particles are trapped in the contactor. High liquid recovery is demonstrated and the effects of process parameters on solid capture are investigated. Three contactors in series yield 94% recovery of solids containing 1500–2895 ppm of REEs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Centrifugal Generation of Droplet-Based 3D Cell Cultures

Quickly and easily producing uniform populations of microsphere-based 3D cell cultures using droplet-based templating methods has the potential to enable widespread use of such platforms in drug discovery or cancer research. Here, we advance the design of centrifuge-based droplet generation devices, describe the use of this platform for droplet generation with controlled cell occupancy, and demonstrate weeklong culture duration. Using simple-to-construct devices and easily implemented protocols, the initial concentration of encapsulated cells is adjustable up to hundreds of cells per microsphere. This work demonstrates the first instance of using centrifugal droplet-generating devices to produce large numbers of cell-encapsulating microspheres. Applications of this versatile methodology include the rapid formation of templated 3D cell culture populations suitable for suspension culture or large batch bioreactor studies that require uniform populations.

Biochemistry & Molecular Biology↗

Countercurrent Actinide Lanthanide Separation Process (ALSEP) Demonstration Test with a Simulated PUREX Raffinate in Centrifugal Contactors on the Laboratory Scale

An Actinide Lanthanide Separation Process (ALSEP) for the separation of trivalent actinides (An(III)) from simulated raffinate solution was successfully demonstrated using a 32-stage 1 cm annular centrifugal contactor setup. The ALSEP solvent was composed of a mixture of 2-ethylhexylphosphonic acid mono-2-ethylhexyl ester (HEH[EHP]) and N,N,N',N'-tetra-(2-ethylhexyl)-diglycolamide (T2EHDGA) in n-dodecane. Flowsheet calculations and evaluation of the results were done using the Argonne’s Model for Universal Solvent Extraction (AMUSE) code using single-stage distribution data. The co-extraction of Zr(IV) and Pd(II) was prevented using CDTA (trans-1,2-diaminocyclohexane-N,N,N',N'-tetraacetic acid) as a masking agent in the feed. For the scrubbing of co-extracted Mo; citrate-buffered acetohydroxamic acid was used. The separation of An(III) from the trivalent lanthanides (Ln(III)) was achieved using citrate-buffered diethylene-triamine-N,N,N',N",N"-pentaacetic acid (DTPA), and Ln(III) were efficiently back extracted using N,N,N',N'-tetraethyl-diglycolamide (TEDGA). A clean An(III) product was obtained with a recovery of 95% americium and curium. The Ln(III) were efficiently stripped; but the Ln(III) product contained 5% of the co-stripped An(III). The carryover of Am and Cm into the Ln(III) product is attributed to too few actinide stripping stages, which was constrained by the number of centrifugal contactors available. Improved separation would be achieved by increasing the number of An strip stages. The heavier lanthanides (Pr, Nd, Sm, Eu, and Gd) and yttrium were mainly routed to the Ln product, whereas the lighter lanthanides (La and Ce) were mostly routed to the raffinate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Separation of gas mixtures by centrifugation

Magnetohydrodynamic (MHD) centrifuge utilizing electric currents and magnetic fields produces a magnetic force which develops supersonic rotational velocities in gas mixtures. Device is superior to ordinary centrifuges because rotation of gas mixture is produced by MHD force rather than mechanical means.

Park, C.↗

Electrophoresis separator combining centrifugal separation

Centrifugal force causes buffer, chosen to be denser than particles, to move outward and particles to move inward. Electrophoresis force can be made to equal centrifugal force. System tends not to be affected by convection and other disturbances that are so troublesome in conventional electrophoresis systems.

Semon, H. W.↗

Some aversive characteristics of centrifugally generated gravity.

The effective weight of rats was manipulated by centrifugation. Two effective weight levels were obtained. In three escape avoidance conditions a lever press produced a change from a base level of 2.1 g to a response level of 1.1 g. In a punishment condition a response produced a change from a 1.1 g level to a 2.1 g level and in an extinction condition responses had no effect on the 2.1 g effective weight level present. All changes took 30 sec and were maintained for an additional 10 sec before a return to base level was initiated. When responses occurred closer together than the 40 sec, they delayed the return to base level by 40 sec. This 40 sec interval is referred to as response-contingent-time. The response rate and amount of response-contingent-time served as the data. The results confirmed previous data that centrifugation is aversive. The results are interpreted as indicating that the aversiveness is attributable to the increase in effective weight, and that rats can discriminate the different angular velocity-radius of rotation combinations used.

Altman, F.↗

Study of the potential for improving the economics of hydrogen liquefaction through the use of centrifugal compressors and the addition of a heavy water plant

An approach to the liquefaction of hydrogen was developed which permits the application of standard centrifugal compressors in place of reciprocating machines. A second fluid, such as propane, is added to the hydrogen prior to compression to form a mixture having a molecular weight much greater than that of hydrogen alone, so that a standard centrifugal compressor can be used. After compression, the mixture is cooled to cryogenic temperature levels where the propane condenses out of the mixture and is separated as a liquid. Since a small amount of deuterium is produced during hydrogen liquefaction, the potential of recovering deuterium and selling it as a co-product was investigated. Deuterium, in the form of heavy water, can be used in certain nuclear reactors as a neutron moderator to reduce the neutron velocity and enhance the probability of neutron collision with uranium nucleii.

Baker, C. R.↗

System analysis of plasma centrifuges and sputtering

System analyses of cylindrical plasma centrifuges are presented, for which the velocity field and electromagnetic fields are calculated. The effects of different electrode geometrics, induced magnetic fields, Hall-effect, and secondary flows are discussed. It is shown that speeds of 10000 m/sec can be achieved in plasma centrifuges, and that an efficient separation of U238 and U235 in uranium plasmas is feasible. The external boundary-value problem for the deposition of sputtering products is reduced to a Fredholm integral equation, which is solved analytically by means of the method of successive approximations.

Hong, S. H.↗

Centrifugal reciprocating compressor

Efficient compressor uses centrifugal force to compress gas. System incorporates two coupled dc motors, each driving separate centrifugal reciprocating-compressor assembly. Motors are synchronized to accelerate and decelerate alternately.

High, W. H.↗

On the characteristics of centrifugal-reciprocating machines

A method of compressing helium gas for cryogenic coolers is presented which uses centrifugal force to reduce the forces on the connecting rod and crankshaft in the usual reciprocating compressor. This is achieved by rotating the piston-cylinder assembly at a speed sufficient for the centrifugal force on the piston to overcome the compressional force due to the working fluid. The rotating assembly is dynamically braked in order to recharge the working space with fluid. The intake stroke consists of decelerating the rotating piston-cylinder assembly and the exhaust stroke consists of accelerating the assembly.

Higa, W. H.↗

Field verification of lateral-torsional coupling effects on rotor instabilities in centrifugal compressors

Lateral and torsional vibration data obtained on a centrifugal compressor train which had shaft instabilities and gear failures is examined. The field data verifies that the stability of centrifugal compressors can be adversely affected by coincidence of torsional natural frequencies with lateral instability frequencies. The data also indicates that excitation energy from gear boxes can reduce stability margins if energy is transmitted either laterally or torsionally to the compressors. The lateral and torsional coupling mechanisms of shaft systems is discussed. The coupling mechanisms in a large industrial compressor train are documented and the potential effect on rotor stability is demonstrated. Guidelines are set forth to eliminate these potential problems by minimizing the interaction of torsional and lateral responses and their effect on rotor stability.

Wachel, J. C.↗

Effects of Ultra-Clean and centrifugal filtration on rolling-element bearing life

Fatigue tests were conducted on groups of 65-millimeter bore diameter deep-groove ball bearings in a MIL-L-23699 lubricant under two levels of filtration. In one test series, the oil cleanliness was maintained at an exceptionally high level (better than a class "000" per NAS 1638) with a 3 micron absolute barrier filter. These tests were intended to determine the "upper limit" in bearing life under the strictest possible lubricant cleanliness conditions. In the tests using a centrifugal oil filter, contaminants of the type found in aircraft engine filters were injected into the filters' supply line at 125 milligrams per bearing-hour. "Ultra-clean" lubrication produced bearing fatigue lives that were approximately twice that obtained in previous tests with contaminated oil using 3 micron absolute filtration and approximately three times that obtained with 49 micron filtration. It was also observed that the centrifugal oil filter had approximately the same effectiveness as a 30 micron absolute filter in preventing bearing surface damage.

Loewenthal, S. H.↗

Effect of weightlessness and centrifugation on red cell survival in rats subjected to space flight

Rats were flown aboard the Soviet biosatellite Cosmos 936 for 18.5 d during August, 1977. Five rats were subjected to near-weightless space flight, as with Cosmos 782, and five rats were subjected to a 1-G force via an on-board centrifuge. These rats and three control groups were injected with 2-(C-14) glycine 19 d preflight. The flight rats were recovered from orbit after 18.5 d of space flight. Erythrocyte hemolysis and lifespan were evaluated in the five groups of rats by quantitation of radioactive carbon monoxide exhaled in the breath which arises from the breakdown of the previously labeled hemoglobin. The results support the previous findings wherein hemolysis was found to increase as a result of weightless space flight. A comparison to the centrifuged animals indicates that artificial gravity attenuates the effect of weightlessness on hemolysis and appears to normalize the hemolytic rate in the early postflight period.

Leon, H. A.↗

Centrifugally driven diffusion of Iogenic plasma

The plasma distribution around Io as measured by Voyager 1 displays an asymmetric discontinuity at Io's orbit that has been suggested to be the signature of centrifugally driven interchange diffusion fed by plasma derived from Io. This hypothesis is explored further and found to be valid. The particular form for the diffusion coefficient appropriate to centrifugally driven turbulence is derived. The nonlinear character of this kind of diffusion is thereby made explicit. Solutions to the nonlinear, time-independent and linearized, time-dependent diffusion equations are given. These display a markedly conservative behavior. The nonlinear, steady state solutions are identical in form to the solutions of the previously studied equation of linear, atmospherically driven diffusion. The linearized, time-dependent solutions exhibit a negative feed-back quality that buffers the response of the density to changes in the source strength. Estimates of the source strength, the diffusion coefficient, and the signal propagation speed are also given.

Siscoe, G. L.↗

Meteor Crater: Energy of formation - Implications of centrifuge scaling

Recent work on explosive cratering has demonstrated the utility of performing subscale experiments on a geotechnic centrifuge to develop scaling rules for very large energy events. The present investigation is concerned with an extension of this technique to impact cratering. Experiments have been performed using a projectile gun mounted directly on the centrifuge rotor to launch projectiles into a suitable soil container undergoing centripetal accelerations in excess of 500 G. The pump tube of a two-stage light-gas gun was used to attain impact velocities of approximately 2 km/sec. The results of the experiments indicate that the energy of formation of any large impact crater depends upon the impact velocity. This dependence, shown for the case of Meteor Crater, is consistent with analogous results for the specific energy dependence of explosives and is expected to persist to impact velocities in excess of 25 km/sec.

Schmidt, R. M.↗