Search NASA⌕ Search

SEARCH · Search NASA

Results for “charge-coupled device (CCD)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A dual charge-coupled device /CCD/, astronomical spectrometer and direct imaging camera. I - Optical and detector systems

The MASCOT (MIT Astronomical Spectrometer/Camera for Optical Telescopes), an instrument capable of simultaneously performing both direct imaging and spectrometry of faint objects, is examined. An optical layout is given of the instrument which uses two CCD's mounted on the same temperature regulated detector block. Two sources of noise on the signal are discussed: (1) the CCD readout noise, which results in a constant uncertainty in the number of electrons collected from each pixel; and (2) the photon counting noise. The sensitivity of the device is limited by the sky brightness, the overall quantum efficiency, the resolution, and the readout noise of the CCD. Therefore, total system efficiency is calculated at about 15%.

Meyer, S. S.↗

Scanning with charge-coupled devices

Results are presented of an investigation of six modes of using CCDs for searches of gamma-ray bursters, debris in geosynchronous space, satellites of asteroids, brown dwarfs, the tenth planet, comets, cometesimals, and various types of asteroids. A new discipline in astrophysics, 'scannerscopy', i.e., surveying with a CCD rather than with photography at a Schmidt telescope, is described. It uses the CCD in scanning rather than in sequencing of stare exposures as is done at most observatories, which can save telescope time and obviates the need for flat-fielding. Attention is given to the Tektronix 2048 x 2048 CCD, 38 arcmin wide, which is used to a limiting magnitude of 20.5 V. It is also shown to be successful for discovering rare and small near-earth asteroids. Possibilities with cameras on spacecraft that pass through the asteroid belt are described.

Gehrels, Tom↗

Iridium Film For Charge-Coupled Device

Usability extended to different environments. Application of thin film of iridium to back surface of back-surface-illuminated charge-coupled device expected to increase and stabilize quantum efficiency at wavelengths less than 4,500 Angstrom. Enhances quantum efficiency according to principle discussed in "Metal Film Increases CCD Output" (NPO-16815). Does not react with hydrogen, so device need not be kept in oxygen: Advantage where high absorption of ultraviolet light by oxygen undesirable; for example, when device used to make astronomical observations from high altitudes.

Hecht, Michael H.↗

Programmable convolution via the chirp Z-transform with CCD's

Technique filtering by convolution in frequency domain rather than in time domain presents possible solution to problem of programmable transversal filters. Process is accomplished through utilization of chip z-transform (CZT) with charge-coupled devices

Buss, D. D.↗

X-Ray Diffraction Apparatus

An x-ray diffraction apparatus for use in analyzing the x-ray diffraction pattern of a sample is introduced. The apparatus includes a beam source for generating a collimated x-ray beam having one or more discrete x-ray energies, a holder for holding the sample to be analyzed in the path of the beam, and a charge-coupled device having an array of pixels for detecting, in one or more selected photon energy ranges, x-ray diffraction photons produced by irradiating such a sample with said beam. The CCD is coupled to an output unit which receives input information relating to the energies of photons striking each pixel in the CCD, and constructs the diffraction pattern of photons within a selected energy range striking the CCD.

Blake, David F.↗

Charge-coupled device imaging spectroscopy of Mars. I - Instrumentation and data reduction/analysis procedures

This paper describes the collection, reduction, and analysis of 0.4-1.0-micron Mars imaging spectroscopy data obtained during the 1988 and 1990 oppositions from Mauna Kea Observatory and provides a general outline for the acquisition and analysis of similar imaging spectroscopy data sets. The U.H. 2.24-m Wide Field Grism CCD Spectrograph was used to collect 13 3D image cubes covering 90 percent of the planet south of 50 deg N in the 0.4-0.8 micron region and covering 55 percent of the planet south of 50 deg N in the 0.5-1.0 micron region. Spectra extracted from these image cubes reveal the detailed character of the Martian near-UV to visible spectrum. Images at red wavelengths reveal the 'classical' albedo markings at 100-500 km spatial resolution while images at blue wavelengths show little surface feature contrast and are dominated by condensate clouds/hazes and polar ice.

Bell, James F., III↗

Spectral analysis using CCDs

Charge-coupled devices (CCDs) are ideally suited for performing sampled-data transversal filtering operations in the analog domain. Two algorithms have been identified for performing spectral analysis in which the bulk of the computation can be performed in a CCD transversal filter; the chirp z-transform and the prime transform. CCD implementation of both these transform algorithms is presented together with performance data and applications.

Hewes, C. R.↗

Application of the Active Pixel Sensor Concept to Guidance and Navigation

Charge-coupled devices (CCDs) have been used extensively in the past in star trackers and fine guidance systems. A new technology, the active pixel sensor, is a possible successor to CCDs. This technology potentially features the same sensitivity and performance of the CCD with additional improvements. These improvements include random access capability, easy window-of-interest readout, non-destructive readout for signal-to-noise improvement, high radiation tolerance, simplified clocking voltages, and easy integration with other on-chip signal processing circuitry. The state-of-the-art of this emerging technology and its potential application to guidance and navigation systems is discussed.

Eisenman, Allan R.↗

A Three-Year Program of Micro- and Nano-System Technology Development for X-Ray Astronomy

For many years the work at MIT aimed at the development of new concepts and technologies for space experiments in high-energy astrophysics, but not explicitly supported by flight programs, has been supported. This work has yielded new devices and techniques for X-ray astronomy, primarily low-noise, deep-depletion charge-coupled devices (CCDS) for spectrally-resolved X-ray imaging, and high-performance transmission gratings for high-resolution X-ray spectroscopy. Among the most significant recent achievements have been the development by G. Ricker and associates of the X-ray CCD camera flying on ASCA, and currently in development for AXAF and Astro-E, and the development by C. Canizares and associates of thick, 200 nm-period transmission gratings employing the phenomenon of phase shifting for high-resolution X-ray spectroscopy up to energies of 8- 1 0 keV that is essential for the operation of the AXAF High Energy Transmission Grating Spectrometer (HETGS). Through the current SR&T grant, the latter technology is now being extended successfully to the fabrication of 100 nm-period transmission gratings, which have twice the dispersion of the AXAF gratings. We note that, among other outcomes, the modest investments of past SR&T Grants at MIT resulted in the development of the key technologies for fully one-half of the scientific instrumentation on AXAF. In addition, NASA flight programs that have benefited from previous SR&T support at MIT include the SAS 3 X-ray Observatory, which carried the first rotation modulation collimator, the Focal Plane Crystal Spectrometer (FPCS) on the Einstein Observatory, the CCD cameras on ASCA and planned for Astro-E, the High Energy Transient Experiment (HETE), the Solar EUV Monitor on the Solar and Heliospheric Observatory (SOHO), the Medium Energy Neutral Atom imager (MENA) on the Image for Magnetopause-to-aurora Global Exploration (IMAGE) mission, and the recently-approved Two Wide-Angle Imaging Neutral-atom Spectrometers (TWINS) Mission of Opportunity.

Canizares, Claude R.↗

Galactic cosmic ray exposure estimates for SAGE-3 mission in polar orbit

An analysis of the effects of galactic cosmic ray (GCR) exposures on charge-coupled devices (CCDs) was performed for the SAGE-III 5-year mission in sun-synchronous orbit between 1996 and 2001. A detailed environment model used in conjunction with a geomagnetic vertical cut-off code provides the predicted 5-year fluence of GCR ions. A computerized solid model of the spacecraft was used to define the effective shield thickness distribution around the CCD detector. The particle fluences at the detector location are calculated with the Langley heavy-ion transport code, and these fluences are used in conjunction with estimated nuclear stopping powers to evaluate dosimetric quantities related to the detector degradation. A previous study analyzing effects of trapped particle and solar flare protons indicated an approximate 20 percent reduction in detector sensitivity for the mission. The galactic cosmic ray contribution was thought to be relatively small and therefore was not previously analyzed. The present study provides quantification of the GCR effects, which are found to contribute less than 1 percent of the total environment degradation.

Nealy, John E.↗

Software simulations of the detection of rapidly moving asteroids by a charge-coupled device

A rendezvous of an unmanned probe to an earth-approaching asteroid has been given a high priority in the planning of interplanetary missions for the 1990s. Even without a space mission, much could be learned about the history of asteroids and comet nuclei if more information were available concerning asteroids with orbits which cross or approach the orbit of earth. It is estimated that the total number of earth-crossers accessible to ground-based survey telescopes should be approximately 1000. However, in connection with the small size and rapid angular motion expected of many of these objects an average of only one object is discovered per year. Attention is given to the development of the software necessary to distinguish such rapidly moving asteroids from stars and noise in continuously scanned CCD exposures of the night sky. Model and input parameters are considered along with detector sensitivity, aspects of minimum detectable displacement, and the point-spread function of the CCD.

Mcmillan, R. S.↗

Radiation damage in scientific charge-coupled devices

Radiation damage is reported on CCDs (charge-coupled devices) that have been primarily exposed to 1.25-MeV gamma rays (Co-60 source). Two important classes of radiation damage are discussed, namely, bulk and ionization effects. Bulk damage or displacement damage is a process in which silicon atoms are displaced from their normal lattice positions by high-energy photons or particles. Single atomic displacements or cluster defect damage is produced, depending on the energy and type of radiation experienced by the detector. Bulk damage creates trapping sites within the CCD's signal channel which in turn degrades charge-transfer efficiency.

Janesick, James↗

Ultraviolet and extreme ultraviolet response of charge-coupled-device detectors

Results of a program to enhance the ultraviolet and extreme ultraviolet response of charge-coupled devices are presented. The ultimate goal of the program is to develop a large format device with both high and stable quantum efficiency from 100 to 3000 A that can be used as a windowless imaging detector in a space environment. Ultraviolet quantum efficiency measurements have been made for several ion-implanted and laser-annealed test CCDs. Quantum efficiencies as high as 22 percent at 2500 A, where the absorption depth in silicon is about 55 A, have been observed in one such test CCD. Quantum efficiency measurements of standard back-illuminated CCDs are also presented.

Stern, R. A.↗

Two-phase charge-coupled device

A charge-transfer efficiency of 99.99% per stage was achieved in the fat-zero mode of operation of 64- and 128-stage two-phase charge-coupled shift registers at 1.0-MHz clock frequency. The experimental two-phase charge-coupled shift registers were constructed in the form of polysilicon gates overlapped by aluminum gates. The unidirectional signal flow was accomplished by using n-type substrates with 0.5 to 1.0 ohm-cm resistivity in conjunction with a channel oxide thickness of 1000 A for the polysilicon gates and 3000 A for the aluminum gates. The operation of the tested shift registers with fat zero is in good agreement with the free-charge transfer characteristics expected for the tested structures. The charge-transfer losses observed when operating the experimental shift registers without the fat zero are attributed to fast interface state trapping. The analytical part of the report contains a review backed up by an extensive appendix of the free-charge transfer characteristics of CCD's in terms of thermal diffusion, self-induced drift, and fringing field drift. Also, a model was developed for the charge-transfer losses resulting from charge trapping by fast interface states. The proposed model was verified by the operation of the experimental two-phase charge-coupled shift registers.

Kosonocky, W. F.↗

Physics of Hard Spheres Experiment: Significant and Quantitative Findings Made

Direct examination of atomic interactions is difficult. One powerful approach to visualizing atomic interactions is to study near-index-matched colloidal dispersions of microscopic plastic spheres, which can be probed by visible light. Such spheres interact through hydrodynamic and Brownian forces, but they feel no direct force before an infinite repulsion at contact. Through the microgravity flight of the Physics of Hard Spheres Experiment (PHaSE), researchers have sought a more complete understanding of the entropically driven disorder-order transition in hard-sphere colloidal dispersions. The experiment was conceived by Professors Paul M. Chaikin and William B. Russel of Princeton University. Microgravity was required because, on Earth, index-matched colloidal dispersions often cannot be density matched, resulting in significant settling over the crystallization period. This settling makes them a poor model of the equilibrium atomic system, where the effect of gravity is truly negligible. For this purpose, a customized light-scattering instrument was designed, built, and flown by the NASA Glenn Research Center at Lewis Field on the space shuttle (shuttle missions STS 83 and STS 94). This instrument performed both static and dynamic light scattering, with sample oscillation for determining rheological properties. Scattered light from a 532- nm laser was recorded either by a 10-bit charge-coupled discharge (CCD) camera from a concentric screen covering angles of 0 to 60 or by sensitive avalanche photodiode detectors, which convert the photons into binary data from which two correlators compute autocorrelation functions. The sample cell was driven by a direct-current servomotor to allow sinusoidal oscillation for the measurement of rheological properties. Significant microgravity research findings include the observation of beautiful dendritic crystals, the crystallization of a "glassy phase" sample in microgravity that did not crystallize for over 1 year in 1g (Earth's gravity), and the emergence of face-centered-cubic (FCC) crystals late in the coarsening process (as small crystallites lost particles to the slow ripening of large crystallites). Significant quantitative findings from the microgravity experiments have been developed describing complex interactions among crystallites during the growth process, as concentration fields overlap in the surrounding disordered phase. Time-resolved Bragg scattering under microgravity captures one effect of these interactions quite conclusively for the sample at a volume fraction of 0.528. From the earliest time until the sample is almost fully crystalline, the size and overall crystallinity grow monotonically, but the number of crystallites per unit volume (number density) falls. Apparently nucleation is slower than the loss of crystallites because of the transfer of particles from small to large crystals. Thus, coarsening occurs simultaneously with growth, rather than following the completion of nucleation and growth as is generally assumed. In the same sample, an interesting signature appears in the apparent number density of crystallites and the volume fraction within the crystallites shortly before full crystallinity is reached. A brief upturn in both indicates the creation of more domains of the size of the average crystallite simultaneous with the compression of the crystallites. Only the emergence of dendritic arms offers a reasonable explanation. The arms would be "seen" by the light scattering as separate domains whose smaller radii of curvature would compress the interior phase. In fiscal year 1999, numerous papers, a doctoral dissertation, and the PHaSE final report were produced. Although this flight project has been completed, plans are in place for a follow-on colloid experiment by Chaikin and Russel that employs a light microscope within Glenn's Fluids and Combustion Facility on the International Space Station. PHaSE is providing us with a deeper understanding of the nure of phase transitions. The knowledge derived has added to the understanding of condensed matter. In addition, the burgeoning study of the dynamics of colloidal self-assembly may lead to the development of a range of photonic materials that control the desirable properties of light. Thus, applications of ordered colloidal structures include not only ultrastructure ceramics, but also photonic crystals and photothermal nanosecond light-switching devices. Industries dealing with semiconductors, electro-optics, ceramics, and composites stand to benefit from such advancements.

Doherty, Michael P.↗

Development of InSb charge-coupled infrared imaging devices: Linear imager

The following results were accomplished in the development of charge coupled infrared imaging devices: (1) a four-phase overlapping gate with 9 transfers (2-bits) and 1.0-mil gate lengths was successfully operated, (2) the measured transfer efficiency of 0.975 for this device is in excellent agreement with predictions for the reduced gate length device, (3) mask revisions of the channel stop metal on the 8582 mask have been carried out with the result being a large increase in the dc yield of the tested devices, (4) partial optical sensitivity to chopped blackbody radiation was observed for an 8582 9-bit imager, (5) analytical consideration of the modulation transfer function degradation caused by transfer inefficiency in the CCD registers was presented, and (6) for larger array lengths or for the insertion of isolated bits between sensors, improvements in InSb fabrication technology with corresponding decrease in the interface state density are required.

Phillips, J. D.↗

Applications of charge-coupled device transversal filters to communication

The paper discusses the computational power of state-of-the-art charged-coupled device (CCD) transversal filters in communications applications. Some of the performance limitations of CCD transversal filters are discussed, with attention given to time delay and bandwidth, imperfect charge transfer efficiency, weighting coefficient error, noise, and linearity. The application of CCD transversal filters to matched filtering, spectral filtering, and Fourier analysis is examined. Techniques for making programmable transversal filters are briefly outlined.

Buss, D. D.↗

Programmable charge-coupled device /CCD/ correlator for pattern classification

The potential use of charge coupled device (CCD) programmable digital/analog correlators for multispectral data classification is discussed. CCD digital/analog correlator technology and the experimental evaluation of a 32-stage 4-bit test device are presented. The design of an IC for use in a multispectral classification system for 16 sensors and 8 bit accuracy is reviewed.

Mayer, D. J.↗