Search NASA⌕ Search

SEARCH · Search NASA

Results for “coherence measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Soot-particle core-shell and fractal structures from small-angle X-ray scattering measurements in a flame

We have characterized soot particles measured in situ in a laminar co-flow ethylene-air diffusion flame using small-angle X-ray scattering (SAXS). The analysis includes temperature measurements made with coherent anti-Stokes Raman spectroscopy (CARS) and complements soot volume-fraction and maturity measurements made with laser-induced incandescence (LII). We compared the results of fits to the SAXS measurements using a unified model and a fractal core-shell model. Power-law parameters yielded by the unified model indicate that aggregates of primary particles are in the mass-fractal regime, whereas the primary particles are in the surface-fractal regime in the middle of the flame. Higher and lower in the flame, the primary-particle power-law parameter approaches 4, suggesting smooth primary particles. Furthermore, these trends are consistent with fits using the fractal core-shell model, which indicate that particles have an established core-shell structure in the middle of the flame and are internally homogeneous at higher and lower heights in the flame. Primary-particle size distributions derived using the fractal core-shell model demonstrate excellent agreement with distributions inferred from transmission electron microscopy (TEM) images in the middle of the flame. Higher in the flame, a second small mode appears in the size distributions, suggesting particle fragmentation during oxidation. Surface oxidation would explain (1) aggregate fragmentation and (2) loss of core-shell structure leading to smoother primary-particle surfaces by removal of carbon overlayers. SAXS measurements are much more sensitive to incipient and young soot particles than LII and demonstrate significant volume fraction from particles low in the flame where the LII signal is negligible.

42 ENGINEERING↗

Direct Monitoring of Conical Intersection Passage via Electronic Coherences in Twisted X-Ray Diffraction

Quantum coherences in electronic motions play a critical role in determining the pathways and outcomes of virtually all photophysical and photochemical molecular processes. However, the direct observation of electronic coherences in the vicinity of conical intersections remains a formidable challenge. Here we propose a novel time-resolved twisted x-ray diffraction technique that can directly monitor the electronic coherences created as the molecule passes through a conical intersection. We show that the contribution of electronic populations to this signal is canceled out when using twisted x-ray beams that carry a light orbital angular momentum, providing a direct measurement of transient electronic coherences in gas-phase molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Proposal for a quantum random number generator using coherent light and a non-classical observable

The prototype quantum random number (random bit) generator (QRNG) consists of one photon at a time falling on a 50:50 beam splitter followed by random detection in one or the other output beams due to the irreducible probabilistic nature of quantum mechanics. Due to the difficulties in producing single photons on demand, in practice, pulses of weak coherent (laser) light are used. In this paper, we take a different approach, one that uses moderate coherent light. It is shown that a QRNG can be implemented by performing photon-number parity measurements. For moderate coherent light, the probabilities of obtaining even or odd parity in photon counts are 0.5 each. Photon counting with single-photon resolution can be performed through use of a cascade of beam splitters and single-photon detectors, as was done recently in a photon-number parity-based interferometry experiment involving coherent light. We highlight the point that unlike most quantum-based random number generators, our proposal does not require the use of classical de-biasing algorithms or post-processing of the generated bit sequence.

Gerry, Christopher C.↗

Direct observation of entangled electronic-nuclear wave packets

We present momentum resolved covariance measurements of entangled electronic-nuclear wave packets created and probed with octave spanning phaselocked ultrafast pulses. We launch vibrational wave packets on multiple electronic states via multiphoton absorption, and probe these wave packets via strong field double ionization using a second phaselocked pulse. Momentum resolved covariance mapping of the fragment ions highlights the nuclear motion, while measurements of the yield as a function of the relative phase between pump and probe pulses highlight the electronic coherence. The combined measurements allow us to directly visualize the entanglement between the electronic and nuclear degrees of freedom and follow the evolution of the complete wavefunction. Published by the American Physical Society 2024

Moğol, Gönenç↗

Projective imaging of high-energy nuclei via coherent exclusive vector meson production in electron-nucleus collisions

One of the major goals of modern nuclear experiments is to study the distributions of gluons inside nuclei at high energy. A key measurement is the coherent exclusive vector meson (VM) production in diffractive electron-nucleus collisions, where the gluon spatial distribution inside the nucleus can be obtained through a Fourier transform of the squared nuclear momentum transfer (|t|) distribution. This research aims to overcome the two main obstacles of the |t| measurement: limited precision in measuring |t| arising from the momentum resolution of the outgoing electron and the overwhelming incoherent background. We demonstrate that by measuring the projected |t| distribution along the direction perpendicular to the electron scattering plane, the effect of the outgoing electron’s momentum resolution can be effectively mitigated, and the diffractive pattern is largely restored. Furthermore, we propose to measure the angular distribution of the VM’s decay daughters to statistically remove the incoherent background.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Measurement of Sub-GeV nu_mu Charged-Current Coherent Pion Production on Argon in MicroBooNE

Coherent pion production, characterized by a neutrino interacting with an entire nucleus without breaking it apart, results in a forward-going muon, pion, and a low-momentum recoil nucleus. This process provides a sensitive probe of neutrino-nucleus interactions and offers a potential standard candle for neutrino-flux normalization in neutrino-oscillation experiments. We present the first measurement of the flux-averaged charged-current coherent pion production cross section on argon nucleus using the MicroBooNE liquid argon time projection chamber. The analysis employs particle identification together with a data-driven background parameterization to isolate the coherent signal. This measurement uses the full MicroBooNE dataset collected from the Fermilab Booster Neutrino Beam, corresponding to an exposure of 1.26E10^21 protons on target and an average neutrino energy of approximately 0.8 GeV. The result provides the first constraint on charged-current coherent pion production on argon nucleus at sub-GeV energies and supplies important input for improving neutrino interaction modeling in current and future experiments such as DUNE.

Hussain, Adil [Kansas State U.] (ORCID:00000001621↗

Five-second coherence of a single spin with single-shot readout in silicon carbide

An outstanding hurdle for defect spin qubits in silicon carbide (SiC) is single-shot readout, a deterministic measurement of the quantum state. Here, we demonstrate single-shot readout of single defects in SiC via spin-to-charge conversion, whereby the defect’s spin state is mapped onto a long-lived charge state. With this technique, we achieve over 80% readout fidelity without pre- or postselection, resulting in a high signal-to-noise ratio that enables us to measure long spin coherence times. Combined with pulsed dynamical decoupling sequences in an isotopically purified host material, we report single-spin T 2 > 5 seconds, over two orders of magnitude greater than previously reported in this system. The mapping of these coherent spin states onto single charges unlocks both single-shot readout for scalable quantum nodes and opportunities for electrical readout via integration with semiconductor devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Peculiarities of adaptive phase correction of optical wave distortions under conditions of ‘strong’ intensity fluctuations

The reason for the loss of efficiency of adaptive phase correction in the propagation of optical waves in a turbulent atmosphere under conditions of ‘strong’ intensity fluctuations is experimentally explained for the first time. Based on the data from experiments conducted on both horizontal and vertical atmospheric paths, we have found that intensity fluctuations begin to significantly affect phase measurements when the coherence radius of the optical wave becomes less than the radius of the first Fresnel zone. Under these conditions, the main meter of adaptive optics systems, i. e. the Hartmann sensor, no longer provides correct measurements of the phase distribution in the presence of deep amplitude modulation. Based on the study of the behaviour of the mode components of the phase fluctuations reconstructed from the results of measurements in various operating regimes, we have found that, first of all, the amplitudes of the lowest modes of phase fluctuation expansion (tilts, defocusing, and astigmatism) are distorted, which, as the analysis shows, is very different from the regime of weak fluctuations. (atmospheric optics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single Electron Self-coherence and Its Wave/Particle Duality in the Electron Microscope

Intensities in high-resolution phase-contrast images from electron microscopes build up discretely in time by detecting single electrons. A wave description of pulse-like coherent-inelastic interaction of an electron with matter implies a time-dependent coexistence of coherent partial waves. Their superposition forms a wave package by phase decoherence of 0.5 - 1 radian with Heisenbergs energy uncertainty ΔE H = $\hbar$/2 Δt -1 matching the energy loss ΔE of a coherent-inelastic interaction and sets the interaction time Δt. In these circumstances, the product of Planck's constant and the speed of light hc is given by the product of the expression for temporal coherence λ 2 /Δλ and the energy loss ΔE. Experimentally, the self-coherence length was measured by detecting the energy-dependent localization of scattered, plane matter waves in surface proximity exploiting the Goos–Hänchen shift. Chromatic-aberration Cc-corrected electron microscopy on boron nitride (BN) proves that the coherent crystal illumination and phase contrast are lost if the self-coherence length shrinks below the size of the crystal unit cell at ΔE > 200 eV. Finally, in perspective, the interaction time of any matter wave compares with the lifetime of a virtual particle of any elemental interaction, suggesting the present concept of coherent-inelastic interactions of matter waves might be generalizable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Suppression of coherent interference to electric-field-induced second-harmonic (E-FISH) signals for the measurement of electric field in mesoscale confined geometries

We present spatially enhanced electric-field-induced second-harmonic (SEEFISH) generation with a chirped femtosecond beam for measurements of electric field in mesoscale confined geometries subject to destructive spurious second-harmonic generation (SHG). Spurious SHG is shown to interfere with the measured E-FISH signal coherently, and thus simple background subtraction is not sufficient for single-beam E-FISH approaches, especially in a confined system with a large surface-to-volume ratio. The results show that a chirped femtosecond beam is effective in preventing higher-order mixing and white light generation in windows near the beam focal point which further contaminates the SEEFISH signal. The successful measurements of electric field of a nanosecond dielectric barrier discharge in a test cell demonstrated that spurious SHG detected with a congruent traditional E-FISH approach can be eliminated using the SEEFISH approach.

Vorenkamp, Madeline↗

Observation of nonlocal Josephson effect on double InAs nanowires

Short-range coherent coupling of two Josephson junctions (JJs) are predicted to generate a supercurrent in one JJ nonlocally modulated by the phase difference in the other. We report on observation of the nonlocal Josephson effect on double InAs nanowires as experimental evidence of the coherent coupling. We measure one JJ sharing one superconducting electrode with the other JJ and observe switching current oscillation as a control of the nonlocal phase difference. Our result will contribute to engineer novel superconducting phenomena with the short-range coherent coupling.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the impact-parameter dependent azimuthal anisotropy in coherent $ρ$ 0 photoproduction in Pb–Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV

This Letter presents the first measurement of the impact-parameter dependent angular anisotropy in the decay of coherently photoproduced $ρ$ 0 mesons. The $ρ$ 0 mesons are reconstructed through their decay into pion pairs. The measured anisotropy corresponds to the amplitude of the cos(2φ) modulation, where φ is the angle between the two vectors formed by the sum and the difference of the transverse momenta of the pions, respectively. The measurement was performed by the ALICE Collaboration at the LHC using data from ultraperipheral Pb–Pb collisions at a center-of-mass energy of $\sqrt{s_{NN}}$ = 5.02 TeV per nucleon pair. Different impact-parameter regions are selected by classifying the events in nuclear-breakup classes. The amplitude of the cos(2φ) modulation is found to increase by about one order of magnitude from large to small impact parameters. Theoretical calculations describe the measured cos(2φ) anisotropy and its impact-parameter dependence as the result of a quantum interference effect at the femtometer scale, arising from the ambiguity regarding which of the nuclei is the photon source in the interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interferometric Constraints on Spacelike Coherent Rotational Fluctuations

Precision measurements are reported of the cross-spectrum of rotationally induced differential position displacements in a pair of colocated 39 m long, high-power Michelson interferometers. One arm of each interferometer is bent 90° near its midpoint to obtain sensitivity to rotations about an axis normal to the plane of the instrument. The instrument achieves quantum-limited sensing of spatially correlated signals in a broad frequency band extending beyond the 3.9-MHz inverse light travel time of the apparatus. For stationary signals with bandwidth Δf>10 kHz, the sensitivity to rotation-induced strain h of classical or exotic origin surpasses CSDδh

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of drifts on scrape-off layer transport in W7-X

Abstract Drifts affect particle, momentum, and energy transport in the scrape-off layer (SOL) of tokamaks and stellarators, altering plasma flows and creating asymmetries between divertors. To understand how drifts affect SOL transport in the W7-X island divertor, an experiment was performed to compare plasmas with matched core parameters but opposite magnetic field directions, and therefore opposite drift transport directions. Parallel flow measurements made with coherence imaging spectroscopy are interpreted with the aid of a diagnostic forward model and a 1D simple SOL model that includes the E × B drift. In low-density plasmas ( n ‾ e < 2 × 10 19 m −3 ), the poloidal E × B drift induces a large poloidal density asymmetry within the island SOL, as measured by divertor Langmuir probes. This in turn causes the parallel flow stagnation point to shift from the position halfway between targets to the X-point in the drift direction, leading to near-unidirectional flow throughout the SOL. As density increases, the effects of the poloidal E × B drift decrease substantially, resulting in a smaller density asymmetry and the development of a counter-streaming flow pattern. For the entire density range probed in this experiment ( n ‾ e = 1.5 − 6 × 10 19 m −3 ), the experimental observations are more consistent with the effects of the poloidal E × B drift than the radial E × B drift.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A global analysis strategy to resolve neutrino NSI degeneracies with scattering and oscillation data

Neutrino non-standard interactions (NSI) with the first generation of standard model fermions can span a parameter space of large dimension and exhibit degeneracies that cannot be broken by a single class of experiment. Oscillation experiments, together with neutrino scattering experiments, can merge their observations into a highly informational dataset to combat this problem. We consider combining neutrino-electron and neutrino-nucleus scattering data from the Borexino and COHERENT experiments, including a projection for the upcoming coherent neutrino scattering measurement at the CENNS-10 liquid argon detector. We extend the reach of these data sets over the NSI parameter space with projections for neutrino scattering at a future multi-ton scale dark matter detector and future oscillation measurements from atmospheric neutrinos at the Deep Underground Neutrino Experiment (DUNE). In order to perform this global anal- ysis, we adopt a novel approach using the copula method, utilized to combine posterior information from different experiments with a large, generalized set of NSI parameters. We find that the contributions from DUNE and a dark matter detector to the Borexino and COHERENT fits can improve constraints on the electron and quark NSI parameters by up to a factor of 2 to 3, even when relatively many NSI parameters are left free to vary in the analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

UA'(1): The search for low-mass dark matter in liquid xenon / Infrared Light for Liquid Xenon TPCs

Liquid xenon-based time projection chambers are used in a variety of applications spanning from the search for dark matter or signals from coherent neutrino-nucleus scattering, to detectors used in medicine and for nuclear non-proliferation. Extending the useful energy range of these detectors down to lower energies will prove extremely useful for such applications. However, various sources of single- and few-electron backgrounds limit the utility of experiments such as LZ and XENONnT to searches of lighter dark matter articles in the MeV mass range. These same backgrounds also limit their utility to measure signals from coherent neutrino-nucleus scattering of solar boron-8 neutrinos and Galactic supernovae. This research worked on multiple mitigation strategies to reduce these backgrounds, through improved xenon purity, infrared irradiation, and an improved theoretical understanding. Multiple dedicated liquid xenon setups were built to execute those tests, and data was successfully taken. Liquid xenon purity was shown to have an important impact, but infrared irradiation did not reduce these backgrounds.

47 OTHER INSTRUMENTATION↗

Utah FORGE: Well 16B(78)-32 Drill Core Fracture Analysis Images and Data

This dataset contains drilling core data from well 16B(78)-32, including PDF documents with flattened core images annotated by feature type and core interval, as well as spreadsheets detailing feature morphologies by depth, planar feature measurements, and planar feature orientations rotated to in situ conditions. Core was recovered from three intervals, one per stimulation stage, in the crystalline rocks affected by the stimulation of well 16A(78)-32. Seven core runs were conducted, yielding 135.8 feet of recovered core. Features in the core were categorized into planar fractures, semi-planar fractures, unbroken mineralized fractures, rough fractures, curviplanar fractures, concave-convex surfaces, and planar compositional features such as mylonite or dike-like structures. Planar features were measured while the core was positioned horizontally, with the core axis aligned to a downhole azimuth of 42 degrees. Planar core measurements from stimulations 2 and 3 that could be confidently correlated with FMI data were rotated to in situ orientations. This was done by rotating the planes along vertical and horizontal axes to match the azimuth and inclination data recorded in the directional survey of well 16B(78)-32, as well as applying an axial rotation to resemble the fracture orientations observed in the FMI log at corresponding depths. Coherent sets of planar fracture measurements were made by aligning the core within each 3-foot section of the dissected core barrel, and between adjacent 3-foot sections within a core run by matching rock fabrics, saw cuts and/or tool marks. Where coherent fracture measurements could not be made within a core run, data sets are denoted by a subscript (i.e. 2-Ta and 2-Tb both come from tangent core run number 2).

15 GEOTHERMAL ENERGY↗

Interferometric bunch length measurements of 3 MeV picocoulomb electron beams

We report picosecond bunch length measurements using an interferometric method for a 3 MeV electron beam having bunch charge ranging from 1 to 14 pC. The method senses the single-cycle sub-terahertz (THz) pulse emitted by each electron bunch as coherent transition radiation which, in turn, is analyzed using a Michelson-type interferometer, forming an interferogram that is then processed to yield the nominal electron bunch length. This sub-THz coherent radiation intensity was measured using a quasi-optical detector (QOD) operated at room temperature. This experiment was quite challenging since the divergence angle of the sub-THz pulse emitted by the low-energy electron bunch exceeds ±10°, and its pulse energy at the entrance to the detector was as low as 100 pJ. When compared to a conventional helium-cooled silicon composite bolometer designed for frequencies above 0.5 THz, the QOD provided much better signal-to-noise ratio in the ~80 GHz frequency range, which was critical for the successful measurement of the bunch length.

36 MATERIALS SCIENCE↗