Formulas establish audio range inductance in beryllium coils
Mathematical modeling is used to determine the effects of resistance and capacitance upon the audio-inductance range of beryllium hammer coils and beryllium nylon-potted coils.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Mathematical modeling is used to determine the effects of resistance and capacitance upon the audio-inductance range of beryllium hammer coils and beryllium nylon-potted coils.
Report examines relationship between coil loss and frequency and heat loss in coil as a function of the magnetic field H. Information is of value to manufacturers of superconducting magnets, motors and generators.
A retrospective summary is presented of the performance of the two-coil superconducting pilot rig which preceded the NASA Lewis bumpy torus. The NASA Lewis bumpy torus facility consists of 12 superconducting coils, each with a 19 cm i.d. and capable of producing magnetic field strengths of 3.0 teslas on their axes. The magnets are equally spaced around a major circumference 1.52 m in diameter, and are mounted with the major axis of the torus vertical in a single vacuum tank 2.59 m in diameter. The design value of maximum magnetic field on the magnetic axis (3.0 T) has been reached and exceeded.
An empirical relation is presented which allows simple computation of volume-averaged winding fields from central fields for coils of small rectangular cross sections. This relation suggests that, in certain applications, ac-loss minimization can be accomplished by use of low winding densities, provided that hysteresis losses are independent of winding density. The ac-loss measurements on coils wound of twisted multifilamentary composite superconductors show no significant dependence on ac losses on winding density, thus permitting the use of winding density as an independent design parameter in loss minimization.
New replaceable carbon insert for deflection coil in electron-beam welder promises to decrease maintenance costs. Inserts made from materials other than carbon (not yet tried) are less expensive, thus reducing costs even further. With carbon insert, deflection coils last longer and are easier to maintain.
Flat coil has rigid printed circuit substrate. New coil structure minimizes RF electric field near glass walls of plasma vessel; therefore reduces direct electron bombardment of glass. Design lends itself well to high production and standardized dimensions.
The coil planet centrifuge uses a centrifugal force field to provide separation of particles based on differences in sedimentation rates by flow through a rotating coiled tube. Three main separations are considered: (1) single phase fresh sheep and human erythrocytes, (2) single phase fixed heep and human erythrocytes, and (3) electrophoretically enhanced single phase fresh sheep and human erythrocytes.
Winding copper tubing on jig ensures reproducible performance. Sequence of steps insures consistent fabrication of levitation-and-melting coils. New method enables technician to produce eight coils per day, 95 percent of them acceptable. Method employs precise step-by-step procedure on specially designed wrapping and winding jig.
Waveform of back-electromotive force reveals defects. Simple pulse test reveals defects in inductor coils. Devised for use on servovalve solenoid coils on Space Shuttle, test also applicable to transformer windings, chokes, relays, and the like.
Proposed electromagnetic gun includes electromagnet coil, turns of which commutated in sequence along barrel. Electrical current fed to two armatures by brushes sliding on bus bars in barrel. Interaction between armature currents and magnetic field from coil produces force accelerating armature, which in turn, pushes on projectile. Commutation scheme chosen so magnetic field approximately coincides and moves with cylindrical region defined by armatures. Scheme has disadvantage of complexity, but in return, enables designer to increase driving magnetic field without increasing armature current. Attainable muzzle velocity increased substantially.
A magnet has been built by the National High Magnetic Field Laboratory for NASA on a cost reimbursement contract. The magnet is intended to demonstrate the technology and feasibility of building a magnet for space based crystal growth. A Bitter magnet (named after Francis Bitter, its inventor) was built consisting of four split coils electrically in series and hydraulically in parallel. The coils are housed in a steel vessel to reduce the fringe field and provide some on-axis field enhancement. The steel was nickel plated and Teflon coated to minimize interaction with the water cooling system. The magnet provides 0.14 T in a 184 mm bore with 3 kW of power.
A report revisits the subject matter of "High-Temperature Coils for Electromagnets" (LEW-17164), NASA Tech Briefs, Vol. 26, No. 8, (August 2002) page 38. To recapitulate: Wires have been developed for use in electromagnets that operate at high temperatures. The starting material for a wire of this type can be either a nickel-clad, ceramic-insulated copper wire or a bare silver wire. The wire is covered by electrical-insulation material that is intended to withstand operating temperatures in the range from 800 to 1,300 F (.430 to .700 C): The starting wire is either primarily wrapped with S-glass as an insulating material or else covered with another insulating material wrapped in S-glass prior to the winding process. A ceramic binding agent is applied as a slurry during the winding process to provide further insulating capability. The turns are pre-bent during winding to prevent damage to the insulation. The coil is then heated to convert the binder into ceramic. The instant report mostly reiterates the prior information and presents some additional information on the application of the ceramic binding agent and the incorporation of high-temperature wire into the windings.
The performance of transition-edge sensors (TES) and their SQUID multiplexed readouts is very sensitive to ambient magnetic field and its fluctuations. In order to run ground experiments on thousands of X-ray TES microcalorimeters with a small uniform ambient magnetic field (< 1 μT, with a uniformity < 0.1 μT), we need a very low ambient field to be trapped into the superconducting magnetic shields. We have designed a sub-Kelvin test platform to reach these specifications. For this purpose, we modeled a new design for the shielding consisting of a series of different mu-metal and superconducting shields, including a niobium shield at 50 mK, a cryoperm (A4K) shield at 3 K, and a mu-metal shield at 300 K. A magnetic field coil is used to vary the local perpendicular magnetic field over the TES array. To optimize this field, we have studied a number of different field-coil designs and the impact of the different shield geometries, in order to reach the required field uniformity.
An experimental rig was designed and constructed at the NASA Glenn Research Center to measure the alternating current (AC) losses of round, multifilament, superconducting (SC), magnesium diboride (MgB2) wire in the temperature range from 20 to 30 K. The rig resembles a permanent magnet (PM) motor with the stator windings omitted. Experiment packs containing the superconductor samples will be placed in the annular space between the rotor and the stator back iron. The original plan was to measure the AC losses by calorimetry using nonboiling liquid hydrogen as the cooling fluid. The present plan is to use helium gas (GHe) under a few bar pressure instead. This report summarizes the calculations that indicate that reasonable results can be obtained, even though the mass density of the GHe will be only a fraction of that of liquid hydrogen. It is necessary to show that the heat transfer coefficient from SC wire to GHe can be high enough, that the temperature rise of the He between the experiment inlet and outlet can be small enough, and that sufficient He flow can be driven by a commercially available He fan. Both straight wire samples to validate loss models and coils to simulate motor stator coils can be tested in the rig. The lowest superconductor temperature that is feasible to reach in the rig is estimated. The temperature range available for samples will be wider with the gaseous He system than it would have been with liquid hydrogen.
Turns-ratio and flux density parameters for four circular coil systems
Magnetic field intensity and field gradients for four octagonal coil systems
Here, this study covers the research and discoveries in two-phase flow-boiling instabilities available in the literature—specifically for a helical-coil steam generator (HCSG), including experimental findings, theoretical research, computational models, and system code analyses—supporting research and development of representative small modular reactors (SMRs). Like other new and advanced reactor systems, water-cooled SMRs require experimental data from both integral and separate thermal-hydraulics test facilities for the verification and validation (V&V) of the computational models and computer codes in order to design and obtain regulatory approval. The complex dynamics of two-phase flow-boiling instabilities includes flow regimes physics phenomena, flow-channel geometries, heat-transfer behavior, and interactions among the solid–liquid-gas within the system boundary, all of which are pivotal for understanding the design and operational challenges of SMRs. This study focuses on identifying the relevant knowledge gaps on boiling instabilities—specifically for a HCSG—and provides insights about future research direction optimizing the transport of thermal energy, mass-flow rates, and boundary conditions that ensure the adequate heat-transfer performance, operational stability, and safety associated with SMR systems.
Since claims of ultra-high (up to ~ 1.5 kiloTesla) magnetic fields appeared in the scientific literature, it became necessary to conduct controlled experiments to determine the validity of these claims and assess the real capability of laser-driven coils (LDCs) to produce high B-field to be used in HEDP (high energy density physics) experiments. This project assessed the viability of generating magnetic fields using LDCs. This was accomplished with a thorough analysis of several focused experiments on the OMEGA EP laser at LLE designed to measure the magnetic field inside LDCs. We demonstrated how problems with prior diagnostic analyses have led to overestimations of the magnetic fields generated from LDCs.