Search NASA⌕ Search

SEARCH · Search NASA

Results for “communications and cybersecurity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Cybersecurity Considerations for Hydrogen Infrastructure in Airport Environments

This report explores key cybersecurity concerns and best practices within environments that serve as reference points for the development of hydrogen fueling infrastructure for aviation. This cybersecurity analysis leverages prior NREL studies: 1) hydrogen fueling station component validation to identify vulnerabilities and failure events documented in physical equipment, and 2) electric aircraft charging infrastructure analysis to explore primary cybersecurity vulnerabilities. It reviews the criticality of digitized technologies in sustaining hydrogen fuel production, storage, and fueling systems, noting cybersecurity concerns that are universal to power systems and industrial control systems in general. In considering cybersecurity vulnerabilities within a future landscape of hydrogen energy for aviation applications, a reference architecture was intended to reveal the points of connection between assets and the potential sensors that are vulnerable to manipulation in the event of compromised access or communication within a SCADA system. A generalized reference architecture can help stakeholders, engineers, or strategists understand connections, criticalities, and standard practices when it comes to designing and planning for new systems. There are several gaps to account for in assessing the future of hydrogen production, storage, and fueling for aviation. Engaging stakeholders, including aircraft manufacturers, electric utilities, site property owners, and local communities, will inform decision-making around site structure, operations, and resources for future hydrogen fueling infrastructure to understand operational needs and cybersecurity awareness. Cybersecurity mitigation strategy must consider physical attack vectors that emerge with the integration of hydrogen systems into existing airport security requirements. The cybersecurity risk assessment contained in this report is an entry point into potential future granular-level analyses to be conducted as part of hazard and risk assessments for safe aviation hydrogen infrastructure, determining how the scale of hydrogen fuel infrastructure for aviation impacts the volume of cyber attack vectors, and what, if any, are the vulnerabilities associated with different types of on-board hydrogen systems. In this nascent development phase, assessing how best to integrate cybersecurity practices into an evolving U.S. aviation landscape provides critical insights into building increased awareness and stakeholder engagement to support a cyber-resilient infrastructure.

08 HYDROGEN↗

Cybersecurity Considerations for Emerging Energy Technologies

AI, cloud computing, post-quantum cryptography, zero-trust architectures, microgrids, and virtual power plants. What do these things have in common? They are all emerging technologies in the clean energy space that will be a critical part of grid modernization efforts. As we work towards clean energy and decarbonization targets, these technologies, developed to solve real-world problems, will help us reach goals and achieve new efficiencies as the paradigm of grid operation shifts. However, there are growing concerns about the cybersecurity risks associated with these trending topics as they are used in critical infrastructure applications. This talk will cover gaps, challenges, and opportunities for the secure implementation of grid modernization solutions and novel energy applications of state-of-the-art networking and communications. Proactive risk mitigation strategies, including the application of cyber-informed engineering, will be discussed. Practical applications of these techniques will help provide countermeasures to the impact of cyberattacks on critical infrastructure technologies in a new, digitized grid landscape.

14 SOLAR ENERGY↗

5G Securely Energized and Resilient: Task 2 and 3 Progress Report

The 5G Securely Energized and Resilient project implemented at the National Renewable Energy Laboratory is sponsored by the Office of the Under Secretary of Defense and is designed to demonstrate the successful deployment of 5G-6G (FutureG) technologies in the context of electrical microgrid scenarios. Through implementation of this project, cybersecurity researchers were able to design a platform to better understand the fundamental system architecture, limitations, and benefits of 5G systems supporting energy system requirements. Although the work for this project was developed in the context of “FutureG Advanced Component Development & Prototypes,” which is a U.S. Department of Defense effort to ensure communications system resilience in the context of military deployments, the results can also apply to communications for electrical grids in general. Several key points were established in Tasks 2 and 3 of this project that are further expanded on in the body of this document.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantum Key Distribution Applicability to Smart Grid Cybersecurity Systems

To meet the increasing demand for electricity and to have a more reliable and resilient electric grid against conventional and extreme events, grid modernization is more crucial now than ever before. This will require the development and deployment of devices that provide advanced communication capabilities. The overall efficiency, reliability, and resilience of the smart grid will be inextricably linked to the exchange of information between these devices. Unfortunately, the increased information flow will increase the potential attack surface and introduce new vulnerabilities. While a smarter grid will depend critically on information flow, these benefits will be accrued only if that information can be protected. Nowadays, information is secured in smart grids primarily through cryptography. However, with the increasing number of sophisticated attacks as well as the increasing computational power, the security of the “classical” cryptographic algorithms is threatened. Quantum information science offers solutions to this problem, specifically quantum key distribution (QKD), which provides a means for the generation and secure distribution of symmetric cryptographic keys. The security of QKD stems ultimately from the very nature of quantum physics. In this paper, we investigate the applicability of QKD to the various smart grid sectors and specific use cases. We have identified 18 smart grid use cases of interest for QKD suitability together with 7 QKD factors used for the assessment of the various use cases. For each use case, the impact to security of the loss of confidentiality, integrity, and/or availability is specified. In addition, the suitability of QKD is assessed for each use case with respect to multiple factors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Role-Based Access Control Policy for Smart Grid Applications: An Offline Deep Reinforcement Learning Approach

Role-based access control (RBAC) is adopted in the information and communication technology domain for authentication purposes. However, due to a very large number of entities within organizational access control (AC) systems, static RBAC management can be inefficient, costly, and can lead to cybersecurity threats. In this paper, a novel hybrid RBAC model is proposed, based on the principles of offline deep reinforcement learning (RL) and Bayesian belief networks. The considered framework utilizes a fully offline RL agent, which models the behavioral history of users as a Bayesian belief-based trust indicator. Thus, the initial static RBAC policy is improved in a dynamic manner through off-policy learning while guaranteeing compliance of the internal users with the security rules of the system. By deploying our implementation within the smart grid domain and specifically within a Distributed Energy Resources (DER) ecosystem, we provide an end-to-end proof of concept of our model. Finally, detailed analysis and evaluation regarding the offline training phase of the RL agent are provided, while the online deployment of the hybrid RL-based RBAC model into the DER ecosystem highlights its key operation features and salient benefits over traditional RBAC models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Facility Cybersecurity Framework Best Practices

Federal facilities are increasingly adopting automation and connecting to the Internet creating an energy-internet-of-things environment that converges operational technology (OT) and information technology (IT). Today's buildings increasingly weave together networked sensors and cyber and physical systems that enable data to be collected, aggregated, exchanged, stored and monetized in new ways. Building technological advances have created new energy technology, services, markets and value creation opportunities (e.g. transactive energy, two-way grid communications, machine learning, and increased use of renewable and distributed energy resources). But as larger data sets are being exchanged at faster speeds between an increasing number of OT systems, it becomes more difficult to protect the security of the data lifecycle and the physical equipment it interacts with. These challenges are especially difficult to overcome because the economic and environmental gain (interoperability, big data, social networks and ubiquitous information sharing) are driving these prominent trends in the digital age. Often cybersecurity is an afterthought. The U.S. Department of Energy’s (DOE) Federal Energy Management Program (FEMP) funded the Pacific Northwest National Laboratory (PNNL) to develop various cybersecurity tools, trainings, and reports to aid federal facility managers – and other building owners and operators – in better applying frameworks and lessons learned from the National Institute of Standards and Technology (NIST) Cybersecurity Framework (CSF), risk management framework (RMF), DOE’s cybersecurity capability maturity model (C2M2), and a wide variety of industry best practices and guidance documents (i.e., NIST 800 series, Department of Defense United Facilities Criteria). This set of tools, collectively known as the FEMP Facility-Related Control System Cyber Toolkit (FRCS Cyber Toolkit)2, is focused on cybersecurity concerns from facility-related control systems and other operational technology (OT), such as industrial control systems (ICS). The FRCS Cyber Toolkit can be applied across six of the sixteen critical infrastructure sectors designated by the Department of Homeland Security, including government facilities, healthcare and public health, commercial facilities (e.g., public assembly, offices, lodging), financial services (e.g., banking and insurance), emergency services (e.g., fire and police stations), and information technology. With increasingly converged IT and OT systems, it is crucial to address OT cybersecurity considerations and assess how the seam of these two systems could impact the overall cybersecurity posture of a facility. The objective of this report is to provide an overview of the best possible method to use FRCS Cyber Toolkit (section 2.0) and distilled cybersecurity best practices for the federal facilities to address growing non-linear cyber threats (section 3.0). Recommendations in this document are aggregated from several NIST and other documents (see Appendix A for additional details).

97 MATHEMATICS AND COMPUTING↗

Facility Cybersecurity Framework Best Practices Version 2.0

Federal facilities are increasingly adopting automation and connecting to the Internet creating an energy-internet-of-things environment that converges operational technology (OT) and information technology (IT). Today's buildings increasingly weave together networked sensors and cyber and physical systems that enable data to be collected, aggregated, exchanged, stored and monetized in new ways. Building technological advances have created new energy technology, services, markets and value creation opportunities (e.g. transactive energy, two-way grid communications, machine learning, and increased use of renewable and distributed energy resources). But as larger data sets are being exchanged at faster speeds between an increasing number of OT systems, it becomes more difficult to protect the security of the data lifecycle and the physical equipment it interacts with. These challenges are especially difficult to overcome because the economic and environmental gain (interoperability, big data, social networks and ubiquitous information sharing) are driving these prominent trends in the digital age. Often cybersecurity is an afterthought.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Facility Cybersecurity Framework Best Practices Version 2.0

Federal facilities are increasingly adopting automation and connecting to the Internet creating an energy-internet-of-things environment that converges operational technology (OT) and information technology (IT). Today's buildings increasingly weave together networked sensors and cyber and physical systems that enable data to be collected, aggregated, exchanged, stored and monetized in new ways. Building technological advances have created new energy technology, services, markets and value creation opportunities (e.g. transactive energy, two-way grid communications, machine learning, and increased use of renewable and distributed energy resources). But as larger data sets are being exchanged at faster speeds between an increasing number of OT systems, it becomes more difficult to protect the security of the data lifecycle and the physical equipment it interacts with. These challenges are especially difficult to overcome because the economic and environmental gain (interoperability, big data, social networks and ubiquitous information sharing) are driving these prominent trends in the digital age. Often cybersecurity is an afterthought.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synergies Between Nuclear Security and Critical Infrastructure: National Legal and Regulatory Frameworks

Nuclear reactors and other nuclear facilities are part of a nation's critical infrastructure assets. Key cross-sector interdependencies, in relation to energy, transportation systems, communications, emergency services, water, information technologies and others, result in inevitable synergies between legal frameworks for the security of nuclear facilities and legal frameworks for the protection of critical infrastructure. The protection of nuclear facilities against sabotage and other malicious acts is paramount in ensuring energy security and thus ensuring uninterrupted energy supply. The protection of other sectors, such as uninterrupted communications, secure water supply, and others, supports a safe and secure operation of nuclear facilities. Some countries rely on broader critical infrastructure frameworks to impose security requirements on nuclear facilities, or to achieve robust cybersecurity systems. This paper will analyze the interdependencies and synergies between the legal and regulatory frameworks for critical infrastructure protection and nuclear facilities' security by comparing various national frameworks. The paper will also propose modalities to leverage the best practices and requirements from each framework towards energy security goals and stronger national nuclear security regimes.

Man, Madalina-Anca↗

MSU IETC ML for Modbus (AN EDGE)

This study explores machine learning for decoding Modbus RTU data using K-Nearest Neighbors (KNN) models. An initial KNN model trained on 8,000 packets achieved 95.15% accuracy. Although ML improves generalization, accuracy still falls short of deterministic methods. These findings have implications for Modbus traffic analysis, intrusion detection in industrial networks, and adaptive error correction in real-time monitoring systems. By refining ML-based decoding, future work could enable more efficient anomaly detection and predictive maintenance in industrial automation and cybersecurity applications.

Communication Protocol↗

Distributed Software-Defined Network Architecture for Smart Grid Resilience to Denial-of-Service Attacks

An important challenge for smart grid security is designing a secure and robust smart grid communications architecture to protect against cyber-threats, such as Denial-of-Service (DoS) attacks, that can adversely impact the operation of the power grid. Researchers have proposed using Software Defined Network frameworks to enhance cybersecurity of the smart grid, but there is a lack of benchmarking and comparative analyses among the many techniques. In this work, a distributed three-controller software-defined networking (D3-SDN) architecture, benchmarking, and comparative analysis with other techniques is presented. The selected distributed flat SDN architecture divides the network horizontally into multiple areas or clusters, where each cluster is handled by a single Open Network Operating System (ONOS) controller. A case study using the IEEE 118-bus system is provided to compare the performance of the presented ONOS-managed D3-SDN, against the POX controller. In addition, the proposed architecture outperforms a single SDN controller framework by a tenfold increase in throughput; a reduction in latency of > 20%; and an increase in throughput of approximately 11% during the DoS attack scenarios.

Agnew Jr., Dennis↗

Defensive Cybersecurity Architecture Design Using Force-on-Force Cyber-Physical Modeling

Currently, nuclear power plant physical security systems are highly dependent on air-gaps as a protective measure against cyber-threats. Cyber-physical threats become more likely as advanced cyber-threat capabilities to jump air-gaps transition into common use. Defending against the emerging threat of cyber-enabled physical intrusions is poorly understood. The consequence of these cyber-physical attacks has no quantitative analysis method to inform risk-informed, performance-based cybersecurity approaches. By modifying the physical security simulation tool Dante, cyber-physical threat consequence was able to be analyzed on a notional facility. The results of this analysis are used to design a Defensive Cybersecurity Architecture (DCSA) for the physical security system to produce example resilience measures for this notional facility. A DCSA defines security levels to provide a graded approach for defending plant functions, and security zones for trusted communication between systems. This approach can be applied to real world systems to produce physical protection systems and response measures that are resilient to cyber-physical threats.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Situational Awareness of Grid Anomalies (SAGA)

The modern power industry becomes more vulnerable to cyber events due to the growing interconnectivity, interdependence, and complexity of the electric power grid. High-fidelity modeling and simulation tools that support the preventative risk analysis on potential cyber-relevant events is essential for ensuring the situational awareness of the system operator as it provides an inexpensive and risk-free environment to test the system responses under various cyber-relevant events and hereby can support research on cyber anomaly detection, optimal protective resource allocation, and mitigation measures. In this webinar, we will share NREL's cybersecurity research capabilities by highlighting the development of a scalable cyber-physical event test bed and demonstration with real hardware in the loop. The developed cyber-physical event test bed is backboned by an integrated transmission, distribution, and communication dynamic co-simulation framework and a plug-and-play cyber event generation module. It is designed to be modular and compatible with parallel computing, and thereby supports large-scale system simulations at an affordable computation cost. The test bed can capture millisecond-to-minutes dynamic frequency and voltage responses under cyber events from the bulk transmission system to the active distribution systems and distributed energy resources at the grid edge.

co-simulation↗

Precursor Analysis Report: Industroyer Targeting Ukraine Electric Power Transport Utility (Ukrenergo) 2016

The Industroyer Targeting Ukraine Electric Power Transport Utility (Ukrenergo) 2016 Precursor Analysis Report leverages publicly available information about the December 2016 cyber attack against the Ukrainian Ukrenergo electric transmission utility and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. Industroyer is a modular malware framework designed to deploy several Industrial Control System (ICS) protocol-specific attack payloads to disrupt electricity distribution. Adversaries deployed Industroyer within the target network on a Microsoft Windows endpoint capable of directly manipulating or communicating with ICS. Industroyer abuses the functionality of a targeted ICS’s legitimate control system to achieve its intended impact. Adversaries likely first gained access to Ukrenergo enterprise networks in early 2016 after a successful spearphishing campaign against organizations in the electric power sector. Adversaries then began capturing credentials beginning on 1 December 2016. This allowed access to the ICS environment at the Pivnichna electric transmission substation outside Kyiv through a device dual-homed on the Information Technology (IT) and ICS networks. Adversaries conducted discovery, targeting, and access to this device using information and previously captured credentials from compromised enterprise IT machines. Finally, the adversaries deployed and launched the Industroyer malware just before midnight on 17 December. By midnight, Ukrenergo had lost control of a targeted substation, resulting in electric power outages for over an hour in the city of Kyiv and the Kyiv region. Researchers and analysts identified 31 unique techniques (used in a sequence of 33 steps) utilized during the attack with a total of 846 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Twenty-nine of the identified techniques used during the Industroyer cyber attack were precursors to the triggering event. Analysis identified 548 observables associated with these precursor techniques, 353 of which were assessed to have an increased likelihood of being perceived in the 300 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Systems and methods for detecting and mitigating cyber attacks on power systems comprising distributed energy resources

Extensive deployment of interoperable distributed energy resources (DER) on power systems is increasing the power system cybersecurity attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid-support functions which can drastically influence power quality, voltage, and the generation-load balance. Investigations of the impact to the power system in scenarios where communications and operations of DER are controlled by an adversary show that each grid-support function exposes the power system to distinct types and magnitudes of risk. The invention provides methods for minimizing the risks to distribution and transmission systems using an engineered control system which detects and mitigates unsafe control commands.

97 MATHEMATICS AND COMPUTING↗

Systems and methods for detecting and mitigating cyber attacks on power systems comprising distributed energy resources

Extensive deployment of interoperable distributed energy resources (DER) on power systems is increasing the power system cybersecurity attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid-support functions which can drastically influence power quality, voltage, and the generation-load balance. Investigations of the impact to the power system in scenarios where communications and operations of DER are controlled by an adversary show that each grid-support function exposes the power system to distinct types and magnitudes of risk. The invention provides methods for minimizing the risks to distribution and transmission systems using an engineered control system which detects and mitigates unsafe control commands.

Johnson, Jay Tillay↗

Safeguarding the Grid: Diverse Resources for Resilience [In My View]

Reports on the vulnerability of the power grid. From wildfires, hurricanes, and floods to cyberattacks, the grid is vulnerable to natural and human-made disasters, which can cause widespread outages that last from hours to months and leave lasting economic impacts. Imagine a coastal region in the United States that has just been hit by a hurricane and lost all power. Besides the electricity infrastructure going out, communications networks, rail transportation, and gasoline pumps may also stop working after the emergency event, which often delays repair efforts to the grid. Unresponsive communications make it difficult to dispatch workers to repair the grid, and missing transportation links delay shipments of replacement equipment for the grid’s restoration.

cybersecurity↗