Search NASA⌕ Search

SEARCH · Search NASA

Results for “compute tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Computer tomography of flows external to test models

Computer tomographic techniques for reconstruction of three-dimensional aerodynamic density fields, from interferograms recorded from several different viewing directions were studied. Emphasis is on the case in which an opaque object such as a test model in a wind tunnel obscures significant regions of the interferograms (projection data). A method called the Iterative Convolution Method (ICM), existing methods in which the field is represented by a series expansions, and analysis of real experimental data in the form of aerodynamic interferograms are discussed.

Prikryl, I.↗

Description of a prototype emission-transmission computed tomography imaging system

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

NASA Discipline Musculoskeletal↗

The Nature of Insoluble Organic Matter in Sutter’s Mill and Murchison Carbonaceous Chondrites: Testing the Effect of X-ray Computed Tomography (XCT) and Exploring Parent Body Organic Molecular Evolution

This study analyzed samples of the Murchison and Sutter’s Mill carbonaceous chondrite meteorites in support of the future analysis of samples returned from the asteroid (10155) Bennu by the OSIRIS-REx (Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer) mission. Focusing specifically on the insoluble organic matter (IOM), this study establishes that a total of 1.3 g of bulk sample from a single chondritic meteorite is sufficient to obtain a wide range of cosmochemical information, including light element analysis (H, C, and N), isotopic analysis (D/H, 13 C/ 12 C, and 15 N/ 14 N), and X-ray fluorescence spectroscopy for major elemental abundances. IOM isolated from the bulk meteorite samples was analyzed by light element and isotopic analysis as described above, 1 H and 13 C solid-state nuclear magnetic resonance spectroscopy, Raman spectroscopy, and complete noble gas analyses (abundances and isotopes). The samples studied included a pair from Murchison (CM2), one of which had been irradiated with high-energy X-rays in the course of computed tomographic imaging. No differences between the irradiated and non-irradiated Murchison samples were observed in the many different chemical and spectroscopic analyses, indicating that any X-ray–derived sample damage is below levels of detection. Elemental, isotopic, and molecular spectroscopic data derived from IOM isolated from the Sutter’s Mill sample reveals evidence that this meteorite falls into the class of heated CM chondrites.

planetary science↗

Modeling of polychromatic attenuation using computed tomography reconstructed images

This paper presents a procedure for estimating an accurate model of the CT imaging process including spectral effects. As raw projection data are typically unavailable to the end-user, we adopt a post-processing approach that utilizes the reconstructed images themselves. This approach includes errors from x-ray scatter and the nonidealities of the built-in soft tissue correction into the beam characteristics, which is crucial to beam hardening correction algorithms that are designed to be applied directly to CT reconstructed images. We formulate this approach as a quadratic programming problem and propose two different methods, dimension reduction and regularization, to overcome ill conditioning in the model. For the regularization method we use a statistical procedure, Cross Validation, to select the regularization parameter. We have constructed step-wedge phantoms to estimate the effective beam spectrum of a GE CT-I scanner. Using the derived spectrum, we computed the attenuation ratios for the wedge phantoms and found that the worst case modeling error is less than 3% of the corresponding attenuation ratio. We have also built two test (hybrid) phantoms to evaluate the effective spectrum. Based on these test phantoms, we have shown that the effective beam spectrum provides an accurate model for the CT imaging process. Last, we used a simple beam hardening correction experiment to demonstrate the effectiveness of the estimated beam profile for removing beam hardening artifacts. We hope that this estimation procedure will encourage more independent research on beam hardening corrections and will lead to the development of application-specific beam hardening correction algorithms.

NASA Discipline Musculoskeletal↗

Boosting Noise2Inverse via enhanced model selection for denoising computed tomography data

Synchrotron-based x-ray tomographic imaging enables the examination of the internal structure of materials at high spatial and temporal resolution. Experimental constraints can impose dose and time limits on the measurements, introducing a higher level of noise and artifacts in the reconstructed images. Deep learning has emerged as a powerful tool to remove noise from reconstructed images. Recently, the Noise2Inverse method was designed specifically for denoising reconstructed images without requiring paired noisy and clean images. This method creates multiple statistically independent reconstructions used to pair the data in which training involves transforming one reconstruction into the other, and vice versa. Originally designed to be used after a fixed number of epochs, we see in practice that this approach may not produce the optimal model and may unnecessarily waste computational resources. Therefore, we propose an alternative method of identifying the best model during training that aligns with the Noise2Inverse method. During validation, we compare the model output of the multiple reconstructions among each other. We hypothesize that the best model is the one that produces images with the highest similarity, implying a convergence in the predicted material properties and absorption values. To compare model outputs, we consider the absolute error, square error, structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), and cosine similarity. We evaluate our method on two simulated tomography datasets and two, real-world, low-contrast, high-energy x-ray tomography datasets. We show our approach is more effective at determining the best model, up to an increase of 12.50% and 12.53% in SSIM and PSNR, respectively, while only requiring a fifth of the training time compared to the original approach.

CT↗

X-Ray Computed Tomography: The First Step in Mars Sample Return Processing

The Mars 2020 rover mission will collect and cache samples from the martian surface for possible retrieval and subsequent return to Earth. If the samples are returned, that mission would likely present an opportunity to analyze returned Mars samples within a geologic context on Mars. In addition, it may provide definitive information about the existence of past or present life on Mars. Mars sample return presents unique challenges for the collection, containment, transport, curation and processing of samples [1] Foremost in the processing of returned samples are the closely paired considerations of life detection and Planetary Protection. In order to achieve Mars Sample Return (MSR) science goals, reliable analyses will depend on overcoming some challenging signal/noise-related issues where sparse martian organic compounds must be reliably analyzed against the contamination background. While reliable analyses will depend on initial clean acquisition and robust documentation of all aspects of developing and managing the cache [2], there needs to be a reliable sample handling and analysis procedure that accounts for a variety of materials which may or may not contain evidence of past or present martian life. A recent report [3] suggests that a defined set of measurements should be made to effectively inform both science and Planetary Protection, when applied in the context of the two competing null hypotheses: 1) that there is no detectable life in the samples; or 2) that there is martian life in the samples. The defined measurements would include a phased approach that would be accepted by the community to preserve the bulk of the material, but provide unambiguous science data that can be used and interpreted by various disciplines. Fore-most is the concern that the initial steps would ensure the pristine nature of the samples. Preliminary, non-invasive techniques such as computed X-ray tomography (XCT) have been suggested as the first method to interrogate and characterize the cached samples without altering the materials [1,2]. A recent report [4] indicates that XCT may minimally alter samples for some techniques, and work is needed to quantify these effects, maximizing science return from XCT initial analysis while minimizing effects.

Welzenbach, L. C.↗

X-Ray Computed Tomography Monitors Damage in Composites

The NASA Lewis Research Center recently codeveloped a state-of-the-art x-ray CT facility (designated SMS SMARTSCAN model 100-112 CITA by Scientific Measurement Systems, Inc., Austin, Texas). This multipurpose, modularized, digital x-ray facility includes an imaging system for digital radiography, CT, and computed laminography. The system consists of a 160-kV microfocus x-ray source, a solid-state charge-coupled device (CCD) area detector, a five-axis object-positioning subassembly, and a Sun SPARCstation-based computer system that controls data acquisition and image processing. The x-ray source provides a beam spot size down to 3 microns. The area detector system consists of a 50- by 50- by 3-mm-thick terbium-doped glass fiber-optic scintillation screen, a right-angle mirror, and a scientific-grade, digital CCD camera with a resolution of 1000 by 1018 pixels and 10-bit digitization at ambient cooling. The digital output is recorded with a high-speed, 16-bit frame grabber that allows data to be binned. The detector can be configured to provide a small field-of-view, approximately 45 by 45 mm in cross section, or a larger field-of-view, approximately 60 by 60 mm in cross section. Whenever the highest spatial resolution is desired, the small field-of-view is used, and for larger samples with some reduction in spatial resolution, the larger field-of-view is used.

Baaklini, George Y.↗

Improving Bone-Health Monitoring in Astronauts: Recommended Use of Quantitative Computed Tomography [QCT] for Clinical and Operational Decisions by NASA

DXA measurement of areal bone mineral density [aBMD,g/cm2] is required by NASA for assessing skeletal integrity in astronauts. Due to the abundance of population-based data that correlate hip and spine BMDs to fragility fractures, BMD is widely applied as a predictor of fractures in the general aging population. In contrast, QCT is primarily a research technology that measures three-dimensional , volumetric BMD (vBMD,mg/cm3) of bone and is therefore capable of differentiating between cortical and trabecular components. Additionally, when combined with Finite Element Modeling [FEM], a computational tool, QCT data can be used to estimate the whole bone strength of the hip [FE strength] for a specific load vector. A recent report demonstrated that aBMD failed to correlate with incurred changes in FE strength (for fall and stance loading) by astronauts over typical 180-day ISS (International Space Station) missions. While there are no current guidelines for using QCT data in clinical practice, QCT increases the understanding of how bone structure and mineral content are affected by spaceflight and recovery on Earth. In order to understand/promote/consider the use of QCT, NASA convened a panel of clinicians specializing in osteoporosis. After reviewing the available, albeit limited, medical and research information from long-duration astronauts (e.g., data from DXA, QCT, FEM, biochemistry analyses, medical records and in-flight exercise performance) the panelists were charged with recommending how current and future research data and analyses could inform clinical and operational decisions. The Panel recommended that clinical bone tests on astronauts should include QCT (hip and lumbar spine) for occupational risk surveillance and for the estimation of whole hip bone strength as derived by FEM. FE strength will provide an improved index that NASA could use to select astronauts of optimal bone health for extended duration missions, for repeat missions or for specific mission operations.

Sibonga, J. D.↗

Investigating the History of Aubrites Using X-Ray Computed Tomography and Bulk Partition Coefficients

The aubrites are a unique group of differentiated meteorites that formed on parent bodies with oxygen fugacities (ƒO2) from ~2 to ~6 log units below the iron-wustite buffer. At these highly reduced condi- tions, elements deviate from the geochemical behavior exhibited at terrestrial ƒO2, and may form FeO-poor silicates, Si-bearing metals, and exotic sulfides. Geochemical examinations of aubrites, such as mineral major-element compositions, bulk-rock compositions, O isotopes, and crystallization ages, are crucial to understand their formation and evolution at extreme ƒO2 conditions. In this study, we determine partitioning relationships of elements between bulk silicate, sulfide, and metal phases within aubrites, and compare the results to partition coefficients determined from petrologic experiments run under mercurian conditions. While previous studies have described the petrology and 2D modal abundances of aubrites, this work provides the first 3D view of aubritic mineralogies, which are com- pared to the available 2D data. Constraints of 3D modal abundances will increase the accuracy of computed bulk distribution coefficients; therefore, 3D scans of aubrite samples are imperative. We utilize X-ray computed tomogra- phy (XCT) to non-destructively analyze the distribution and abundances of mineral phases in aubrites and locate composite clasts of sulfide grains for future analysis.

Wilbur, Z. E.↗