An Analysis of Nuclear-Rocket Nozzle Cooling

A nuclear-rocket regenerative-cooling analysis was conducted over a range of reactor power of 46 to 1600 megawatts and is summarized herein. Although the propellant (hydrogen) is characterized by a large heat-sink capacity, an analysis of the local heat-flux capability of the coolant at the nozzle throat indicated that, for conventional values of system pressure drop, the cooling capability was inadequate to maintain a selected wall temperature of 1440 R. Several techniques for improving the cooling capability were discussed, for example, high pressure drop, high wall temperature, refractory wall coatings, thin highly conductive walls, and film cooling. In any specific design a combination of methods will probably be utilized to achieve successful cooling.

Robbins, William H.↗

Review and status of liquid-cooling technology for gas turbines

A review was conducted of liquid-cooled turbine technology. Selected liquid-cooled systems and methods are presented along with an assessment of the current technology status and requirements. A comprehensive bibliography is presented.

Vanfossen, G. J., Jr.↗

Development of Passive Fuel Cell Thermal Management Technology

The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA exploration program. The passive thermal management system relies on heat conduction within the cooling plate to move the heat from the central portion of the cell stack out to the edges of the fuel cell stack rather than using a pumped loop cooling system to convectively remove the heat. Using the passive approach eliminates the need for a coolant pump and other cooling loop components which reduces fuel cell system mass and improves overall system reliability. Previous analysis had identified that low density, ultra-high thermal conductivity materials would be needed for the cooling plates in order to achieve the desired reductions in mass and the highly uniform thermal heat sink for each cell within a fuel cell stack. A pyrolytic graphite material was identified and fabricated into a thin plate using different methods. Also a development project with Thermacore, Inc. resulted in a planar heat pipe. Thermal conductivity tests were done using these materials. The results indicated that lightweight passive fuel cell cooling is feasible.

Burke, Kenneth A.↗

Testing of a Neon Loop Heat Pipe for Large Area Cryocooling

Cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks is required for future NASA missions. A cryogenic loop heat pipe (CLHP) can provide a closed-loop cooling system for this purpose and has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A neon CLHP was tested extensively in a thermal vacuum chamber using a cryopump as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components. Tests conducted included loop cool-down from the ambient temperature, startup, power cycle, heat removal capability, loop capillary limit and recovery from a dry-out, low power operation, and long duration steady state operation. The neon CLHP demonstrated robust operation. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully by applying power to both the pump and evaporator without any pre-conditioning. It could adapt to changes in the pump power andor evaporator power, and reach a new steady state very quickly. The evaporator could remove heat loads between 0.25W and 4W. When the pump capillary limit was exceeded, the loop could resume its normal function by reducing the pump power. Steady state operations were demonstrated for up to 6 hours. The ability of the neon loop to cool large areas was therefore successfully verified.

Cryogenics↗

Mergers, cooling flows, and evaporation

Mergers (the capture of cold gas, especially) can have a profound influence on the hot coronal gas of early-type galaxies and clusters, potentially inducing symptoms hitherto attributed to a cooling flow, if thermal conduction is operative in the coronal plasma. Heat can be conducted from the hot phase into the cold phase, simultaneously ionizing the cold gas to make optical filaments, while locally cooling the coronal gas to mimic a cooling-flow. If there is heat conduction, though, there is no standard cooling-flow since radiative losses are balanced by conduction and not mass deposition. Amongst the strongest observational support for the existence of cooling-flows is the presence of intermediate temperature gas with x-ray emission-line strengths in agreement with cooling-flow models. Here, x-ray line strengths are calculated for this alternative model, in which mergers are responsible for the observed optical and x-ray properties. Since gas around 10(exp 4) K is thermally stable, the cold cloud need not necessarily evaporate and hydrostatic solutions exist. Good agreement with the x-ray data is obtained. The relative strengths of intermediate temperature x-ray emission lines are in significantly better agreement with a simple conduction model than with published cooling-flow models. The good agreement of the conduction model with optical, infrared and x-ray data indicates that significantly more theoretical effort into this type of solution would be profitable.

Sparks, W. B.↗

Cosmic-ray heating of cooling flows - A critical analysis

It is shown that a combination of MHD wave-mediated cosmic ray heating and thermal conduction could balance cooling in intracluster media and substantially reduce the rate of inflow. The appropriate system of steady state equations is solved, including a new self-consistent formulation for the cosmic-ray diffusivity. Models which can produce substantial positive temperature gradients in static configurations are found when conduction is reduced by a factor of 10 or more. These models have too-flat thermal pressure profiles compared with observations. It is found that cosmic-ray heating is unlikely either to stabilize positive density perturbations against condensation or to contribute appreciably to the powering of the optical filaments.

Loewenstein, Michael↗

Effect of free-stream turbulence on film cooling

Film-cooling experiments were conducted at four levels of free-stream turbulence to test the hypothesis that the film-cooling effectiveness is inversely related to the free-stream turbulence level. The hot-gas operating conditions were held constant at a temperature of 590 K, a pressure of 1 atmosphere, and a velocity of 62 m/sec. The film-cooling air was at ambient inlet temperature, and the film-cooling flow rates were 2.5, 5.0, 7.5, and 10.0 percent of the total airflow. Blockage plates with blockage areas of 0, 52, 72, and 90 percent were placed upstream of the film-cooling slot and produced axial turbulence intensities of 7, 14, 23, and 35 percent, respectively. The film-cooling effectiveness decreased as much as 50 percent as the freestream turbulence intensity was increased from 7 to 35 percent. The value of the turbulent mixing coefficient used in previous work was compared with the axial turbulence intensity. The turbulent mixing coefficient was found to be 10 to 40 percent of the axial turbulence intensity.

Marek, C. J.↗

Mathematical equations for heat conduction in the fins of air-cooled engines

The problem considered in this report is that of reducing actual geometrical area of fin-cooling surface, which is, of course, not uniform in temperature, to equivalent cooling area at one definite temperature, namely, that prevailing on the cylinder wall at the point of attachment of the fin. This makes it possible to treat all the cooling surface as if it were part of the cylinder wall and 100 per cent effective. The quantities involved in the equations are the geometrical dimensions of the fin, thermal conductivity of the material composing it, and the coefficient of surface heat dissipation between the fin and the air streams.

Harper, R R↗

Multiphysics Computational Analysis of a Perforated Plate Cooling Flow

A multiphysics analysis of a film cooling flow was conducted using a computational fluid dynamics (CFD) solver in conjunction with a conjugate heat transfer (CHT) solver. The film cooling problem consisted of a square nozzle producing a heated subsonic jet over a perforated plate with three sections of 45 cooling holes each. Results from the multiphysics analysis were compared to a CFD-only approach and experimental results. Reynolds-averaged Navier-Stokes (RANS) computations were employed first, with and without the CHT solver. The multiphysics approach provided much closer agreement with experimentally measured plate temperatures than the CFD-only approach. Comparisons of computed velocities and temperatures were also made with experimental data. Hybrid RANS-large eddy simulation calculations employing the Delayed Detached Eddy Simulation (DDES) approach were also conducted within the multiphysics framework. The DDES approach was unable to resolve turbulent structures in the near wall regions. Hence, the RANS part of the DDES model was used in near wall regions, and produced surface temperatures along with velocity and temperature profiles close to the wall that were very similar to the RANS results. The DDES approach did resolve structures in the outer portion of the boundary layer especially near the end of the plate where the boundary layer was thicker. The key result was the improved surface temperatures produced by the multiphysics approach employing CHT over the fluid-only approach.

Computational Fluid Dynamics↗

Thermal Performance Testing of EMU and OSS Liquid Cooling Garments

A test was conducted to evaluate three factors influencing the thermal performance of liquid cooling garments (LCG): (1) the comparable thermal performance of an Oceaneering developed engineering evaluation unit (EEU) prototype LDG, (2) the effect of the thermal comfort undergarment (TCU), and (3) the performance of a torso or upper body only LCG configuration. To evaluate the thermal performance of each configuration a metabolic test was conducted, utilizing suited subjects to generate the metabolic heat. For this study three (3) test subjects of similar health and weight produced a metabolic load on the LDG configuration by either resting (300-600 BTU/hr), walking at a slow pace (1200 BRU/hr), and walking at a brisk pace (2200 BTU/hr), as outlined in Figure 1, the metabolic profile. During the test, oxygen consumption, heart rate, relative humidity, air flow, inlet and outlet air pressure, inlet and outlet air temperature, delta air temperature, water flow (100 lb/hr), inlet water temperature (64 F), delta water temperature, water pressure, core body temperature, skin temperature, and sweat loss data was recorded. Four different test configurations were tested, with one configuration tested twice, as outlined in Table 1. The test was conducted with the suit subjects wearing the Demonstrator Suit, pressurized to vent pressure (approximately 0.5 psig). The demonstrator suit has an integrated ventilation duct system and was used to create a relevant environment with a captured ventilation return, an integrated vent tree, and thermal insulation from the environment.

Rhodes, Richard↗

Evaporative cooling of flare plasma

A one-dimensional loop model for the evaporative cooling of the coronal flare plasma was investigated. Conductive losses dominated radiative cooling, and the evaporative velocities were small compared to the sound speed. The profile and evolution of the temperature were calculated. The model was in agreement with soft X-ray observations on the evolution of flare temperatures and emission measures. The effect of evaporation was to greatly reduce the conductive heat flux into the chromosphere and to enhance the EUV emission from the coronal flare plasma.

Antiochos, S. K.↗

Evaluation of water cooled supersonic temperature and pressure probes for application to 2000 F flows

The development of water cooled supersonic probes used to study high temperature jet plumes is addressed. These probes are: total pressure, static pressure, and total temperature. The motivation for these experiments is the determination of high temperature supersonic jet mean flow properties. A 3.54 inch exit diameter water cooled nozzle was used in the tests. It is designed for exit Mach 2 at 2000 F exit total temperature. Tests were conducted using water cooled probes capable of operating in Mach 2 flow, up to 2000 F total temperature. Of the two designs tested, an annular cooling method was chosen as superior. Data at the jet exit planes, and along the jet centerline, were obtained for total temperatures of 900 F, 1500 F, and 2000 F, for each of the probes. The data obtained from the total and static pressure probes are consistent with prior low temperature results. However, the data obtained from the total temperature probe was affected by the water coolant. The total temperature probe was tested up to 2000 F with, and without, the cooling system turned on to better understand the heat transfer process at the thermocouple bead. The rate of heat transfer across the thermocouple bead was greater when the coolant was turned on than when the coolant was turned off. This accounted for the lower temperature measurement by the cooled probe. The velocity and Mach number at the exit plane and centerline locations were determined from the Rayleigh-Pitot tube formula.

Lagen, Nicholas T.↗

A high temperature thermal diffusivity determination procedure for solids and liquids

A new method for measuring the thermal diffusivity of materials at high temperatures is presented. The method is applicable to solids on Earth, and to liquids in the reduced gravity environment of space. It is especially suited to levitated liquid metals at elevated temperatures where thermal diffusivity data is not available. The method is applied in two parts, such that lumped analysis is valid in the first part, and Fourier's law of conduction is valid in the second. In both parts, the spherical specimen is assumed to have been heated to a desired temperature and cooled. An inverse conduction problem is then formulated and solved using Laplace transformation techniques. Using this solution, sample sizes, and experimentally obtained surface temperature history, the thermal diffusivity is determined by minimizing a function that satisifies the heat balance at the surface. Minimization is performed using a modified quasilinearization algorithm. Accuracy is very sensitive to error in the temperature data and increases with better curve fits to the temperature data. An error analysis is also performed, and the effect of errors in the various parameters on the evaluated thermal diffusivity is determined. An experimental study for solids on Earth is suggested, before development for implementation in space.

Bayazitoglu, Yildiz↗

Measured effects of coolant injection on the performance of a film cooled turbine

Tests have been conducted on a 20-inch diameter single-stage air-cooled turbine designed to evaluate the effects of film cooling air on turbine aerodynamic performance. The present paper reports the results of five test configurations, including two different cooling designs and three combinations of cooled and solid airfoils. A comparison is made of the experimental results with a previously published analytical method of evaluating coolant injection effects on turbine performance.

Mcdonel, J. D.↗

Experimental verification of film-cooling concepts on a turbine vane

An investigation was conducted to verify some film cooling concepts applied to gas turbine vanes. The film cooling air was ejected from a single row of holes on the convex surface and a double row of holes of the concave surface. Tests were conducted at a gas temperature of 1260 K, a gas pressure of 3 atmospheres, and a coolant temperature of 280 K. Mass-velocity ratios were varied between 0 and 2.0. Data were taken without film-cooling holes, with film-cooling holes but without blowing, and with blowing. A small amount of blowing into a nonturbulent boundary layer caused an increase in vane temperatures. Film cooling when combined with convection cooling was verified to be more effective than either film or convective cooling alone.

Gladden, H. J.↗

Thermal modulation for gas chromatography

A thermal modulator device for gas chromatography and associated methods. The thermal modulator device includes a recirculating fluid cooling member, an electrically conductive capillary in direct thermal contact with the cooling member, and a power supply electrically coupled to the capillary and operable for controlled resistive heating of the capillary. The capillary can include more than one separate thermally modulated sections.

Hasselbrink, Ernest F.↗

Thermal modulation for gas chromatography

A thermal modulator device for gas chromatography and associated methods. The thermal modulator device includes a cooling member, an electrically conductive capillary in direct thermal contact with the cooling member, and a power supply electrically coupled to the capillary and operable for controlled resistive heating of the capillary.