Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Flow Boiling in Microgap Coolers - Suborbital Flight Results

Flow Boiling in Microgap Coolers (FBMC) is a thermal management technique that provides embedded, on-site heat removal for power dense electronic components and systems. The dielectric coolant undergoes liquid-to-vapor phase change as it passes through channels integrated within or between devices. By facilitating direct contact between the coolant and heat-generating devices and relying on phase change, the system provides tight temperature control, hot spot mitigation, very high heat transfer coefficients, and low pumping power. Ground tests demonstrated removal of high heat fluxes (up to 500 kW/m2), very high coefficients of performance (up to 40 W of heat transferred per W of pumping power), and consistent performance across five evaporator orientations under the appropriate conditions. As a follow-on study and to better assess the role of gravity on such two-phase systems, the FBMC payload was developed and flown twice aboard the Blue Origin New Shepard space vehicle in January and May 2019. Each flight exposed the payload to weightlessness (150 seconds below 0.01 g) and shorter periods of high-g during ascent (up to 3 g) and descent (up to 5 g). The flow boiling performance was consistent independent of the acceleration levels, which provides confidence that such systems will provide consistent performance when tested on the ground, orbiting or traveling through weightlessness, and operating on the surface of the Moon, Mars, and other planetary bodies. Details of the flight results, payload development, flight environment, and planned future testing will be presented.

Flow boiling↗

Local Heat Transfer Measurements in Cooler for sCO2 Power Cycles with Dilute Nitrogen and Argon Impurities

An experimental investigation of heat transfer in CO2 and CO2/N2 and CO2/argon mixtures undergoing cooling near the pseudocritical temperature has been conducted. The conditions are representative of direct sCO2 cycle coolers. Three tubing test articles were tested: conventional drawn tubing, an additively manufactured tube with a square cross section, and an additively manufactured tube with a square cross section and ribs angled 60° relative to the flow direction. The axial heat transfer coefficient distribution was determined with local wall temperature measurements. This work concludes that dilute concentrations (< 2%) of nitrogen and argon have a negligible impact on heat transfer coefficient and on friction factor.

Searle, Matthew↗

AIRS PFM Pulse Tube Cooler System-level Performance

JPL's Atmospheric Infrared Sounder (AIRS) instrument is being built to make precision measurements of air temperature over the surface of the Earth as a function of elevation; the flight instrument is in the final stages of assembly and checkout at this time, and uses a pair of TRW pulse tube cryocoolers operating at 55K to cool its sensitive IR focal plane.

AIRS PFM Pulse Tube Cooler System-level JPL's Atmo↗

EMI Performance of the AIRS Cooler and Electronics

The TRW pulse tube cryocooler for JPL's Atmospheric Infrared Sounder (AIRS) instrument is required to meet stringent requirements for radiated electric and magnetic fields, conducted emissions on the input power bus, and electromagnetic susceptivility.

EMI AIRS Cooler Electronics Cryocooler↗

Effect of seasonal anoxia on geochemical cycling in a stratified pond: Comparison to cooler pond conditions 40 years ago

Seasonal stratification in temperate lakes deeper than a few meters creates favorable conditions for pronounced vertical redox zones, often resulting in anaerobic hypolimnions and significant geochemical changes. Here, this study examined thermocline formation and trace element behavior in a seasonally stratified pond amid rising air temperatures. Over two years, data were collected from Pond B at the US Department of Energy Savannah River Site in Aiken, South Carolina. Pond B, a man-made monomictic reservoir, received cooling water from a nuclear reactor from 1961 to 1964. Strong thermal stratification forms a distinct thermocline in May and progresses downward until November. Compared to the 1980s, this study shows a delayed onset and extended duration of stratification. The prolonged summer stratification reduces deep water oxygen replenishment, extending hypoxic conditions. Trace and major elements sampled in the water column revealed strong correlations between As, Fe, and Mn profiles, with concentrations increasing by 1–2 orders of magnitude in the anaerobic hypolimnion. This period captured the seasonal transition from winter mixing to summer stratification to fall overturn. Under anoxic conditions, Fe(III) reduces to Fe(II) in the sediment, releasing dissolved iron into the water column. The extended anoxic periods likely promoted arsenic release from sediments. Prolonged anoxia may enhance arsenic mobilization and solubility in the lake. This study illustrates how climate-induced changes in seasonal stratification of contaminated waters can convert contaminant sinks into sources, offering insights into the cycling of arsenic and other dissolved ions in stratified lakes and their implications for water quality management.

Anoxic conditions↗

Planning for cooler communities: Vacant lots as components of heat resilience in Mesa, Arizona

Vacant lots are often perceived as contributing to negative socioeconomic and environmental impacts on surrounding communities. However, they also offer opportunities for strategic interventions that promote heat resilience. This study uses a decision-scale congruence analytic approach to examine the correlation between extreme heat and community resilience in the context of vacant lots in the city of Mesa, Arizona. By identifying and analyzing over 1,200 vacant lots, we assessed spatial patterns of Community Resilience Estimates (CRE) for Heat and Body Heat Storage (BHS) to understand their correlation at the unit of analysis of vacant lots, where key decisions are made concerning land use. The results reveal a nonrandom spatial distribution of CRE for Heat and BHS across Mesa’s vacant lots. Vacant lots are disproportionately concentrated in neighborhoods with lower resilience, exacerbating heat exposure. Communities with limited access to cooling infrastructure, tree canopy, and other resources experience lowered heat resilience. A positive correlation between CRE for Heat and BHS shows that areas with higher heat exposure tend to have lower community resilience, reinforcing the need for cooling interventions. This study highlights the potential for converting vacant lots into heat-resilient, community-serving spaces. Using our findings, decision makers can identify priority areas and leverage vacant lots to mitigate heat impacts and foster community resilience.

community resilience↗

OPTIMIZATION OF COOLING DISTRIBUTION OF THE EIC SHC COOLER ERL

The Electron-Ion Collider (EIC) Hadron Storage Ring (HSR) will use strong hadron cooling to maintain the beam brightness and high luminosity during long collision ex?periments. An Energy Recovery Linac is used to deliver the high-current high-brightness electron beam for cooling. For the best cooling effect, the electron beam requires low emittance, small energy spread, and uniform longitudinal distribution. In this work, we simulate and optimize the longitudinal laser-beam distribution shaping at the photo?cathode, modeling space charge forces accurately. Machine parameters such as RF cavity phases are optimized in con?junction with the beam distribution using a genetic optimizer. We demonstrate improvement of the cooling distribution in key parameters.

Wang, N.↗