Search NASA⌕ Search

SEARCH · Search NASA

Results for “coordinated optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Gaussian process based optimization of molecular geometries using statistically sampled energy surfaces from quantum Monte Carlo

Optimization of atomic coordinates and lattice parameters remains a significant challenge to the wide use of stochastic electronic structure methods such as quantum Monte Carlo (QMC). Measurements of the forces and stress tensor by these methods contain statistical errors, challenging conventional gradient-based numerical optimization methods that assume deterministic results. Additionally, forces are not yet available for some methods, wavefunctions, and basis sets and when available may be expensive to compute to sufficiently high statistical accuracy near energy minima, where the energy surfaces are flat. Here, we explore the use of Gaussian process based techniques to sample the energy surfaces and reduce sensitivity to the statistical nature of the problem. We utilize Latin hypercube sampling, with the number of sampled energy points scaling quadratically with the number of optimized parameters. Furthermore, we show these techniques may be successfully applied to systems consisting of tens of parameters, demonstrating QMC optimization of a benzene molecule starting from a randomly perturbed, broken symmetry geometry.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fine-tuned local coordination environment of Pt single atoms on ceria controls catalytic reactivity

Constructing single atom catalysts with fine-tuned coordination environments can be a promising strategy to achieve satisfactory catalytic performance. Herein, via a simple calcination temperature-control strategy, CeO 2 supported Pt single atom catalysts with precisely controlled coordination environments are successfully fabricated. The joint experimental and theoretical analysis reveals that the Pt single atoms on Pt 1 /CeO 2 prepared at 550 °C (Pt/CeO 2 -550) are mainly located at the edge sites of CeO 2 with a Pt–O coordination number of ca. 5, while those prepared at 800 °C (Pt/CeO 2 -800) are predominantly located at distorted Ce substitution sites on CeO 2 terrace with a Pt–O coordination number of ca. 4. Pt/CeO 2 -550 and Pt/CeO 2 -800 with different Pt 1 -CeO 2 coordination environments exhibit a reversal of activity trend in CO oxidation and NH 3 oxidation due to their different privileges in reactants activation and H 2 O desorption, suggesting that the catalytic performance of Pt single atom catalysts in different target reactions can be maximized by optimizing their local coordination structures.

36 MATERIALS SCIENCE↗

A BI-LEVEL APPROACH TO FUTURE POWER SYSTEM CO-OPTIMIZATION WITH HIGH PENETRATION OF RENEWABLE ENERGY AND RESPONSIVE DEMAND

Electricity generation accounts for nearly half of the total CO2 emissions in the United States. For this reason, the development and integration of renewable resources will play an essential role in achieving the societal objective of mitigating climate change through reduction of greenhouse gas emissions. In conjunction with the environmental benefits of renewable energy, the most common renewable sources, such as wind and solar, also increase the uncertainties surrounding generation in power systems, which adds significant challenges to the system operation and planning. The uncertainties and forecasting errors surrounding renewable generation are normally addressed through the use of reserves from traditional generators. At greater levels of renewable penetration, sufficient generator reserves may not be available or economically viable. In contrast, the promise of demand-side resources in this arena lies in the spatially widespread availability, rapid response potential, and lower cost of features that already exist in the system. However, the challenge of responsive demand arises from the need to understand, manage, and incentivize a very large number of resources to participate effectively in efficient operation of the complex power system. Since demand response comes from the distribution system, microgrids as the basic building blocks of future distribution systems will be a critical environment for the study of demand response. To support integration of microgrids with flexible loads in future power systems, the operational mode of power systems will need to evolve. Therefore, it is going to be critical to have new and efficient co-optimization methods for coordination of the various power market participants and the scheduling of resources in the power systems of the future. Motivated by the rapid increase in renewable penetration, the need for effective demand response programs, and a changing system structure, this dissertation seeks to define a new strategy that supports co-optimization of various participants in power systems with emphasis on high renewable penetration and demand response. This strategy has three components; 1) an exploration of the capabilities of different types of demand response programs in a microgrid, 2) development and implementation of a bi-level framework for co-optimization of the main grid with high renewable penetration and a microgrid with demand response capabilities, and 3) expansion of the bi-level framework from a microgrid to a general distribution system to explore the advantages of the bi-level co-optimization approach over the traditional optimization approach. Conclusions of this work illustrate that the stochastic rolling horizon approach could effectively manage the operation of a microgrid with various demand response programs. In addition, the bi-level approach is a promising co-optimization framework for the transmission and distribution levels that could increase system renewable penetration and reduce operation costs. Compared to the traditional framework, the bi-level framework yields more equitable cost sharing patterns among the market participants as well as better support for the power system evolution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Direct construction of optimized stellarator shapes. Part 1. Theory in cylindrical coordinates

The confinement of the guiding-centre trajectories in a stellarator is determined by the variation of the magnetic field strength $B$ in Boozer coordinates $(r,\unicode[STIX]{x1D703},\unicode[STIX]{x1D711})$ , but $B(r,\unicode[STIX]{x1D703},\unicode[STIX]{x1D711})$ depends on the flux surface shape in a complicated way. Here we derive equations relating $B(r,\unicode[STIX]{x1D703},\unicode[STIX]{x1D711})$ in Boozer coordinates and the rotational transform to the shape of flux surfaces in cylindrical coordinates, using an expansion in distance from the magnetic axis. A related expansion was done by Garren and Boozer ( Phys. Fluids B, vol. 3, 1991 a , 2805) based on the Frenet–Serret frame, which can be discontinuous anywhere the magnetic axis is straight, a situation that occurs in the interesting case of omnigenity with poloidally closed $B$ contours. Our calculation in contrast does not use the Frenet–Serret frame. The transformation between the Garren–Boozer approach and cylindrical coordinates is derived, and the two approaches are shown to be equivalent if the axis curvature does not vanish. The expressions derived here help enable optimized plasma shapes to be constructed that can be provided as input to VMEC and other stellarator codes, or to generate initial configurations for conventional stellarator optimization.

Physics↗

What Can We Learn from US National Transmission Studies?

Multiple US regions have announced new electricity transmission plans, are actively revisiting the future role of transmission, and could benefit from findings from recent national-scale transmission studies. A review of seven national studies shows that significant transmission expansion is cost-optimal for serving new demand, integrating additional resources, and supporting grid reliability. A majority of the reviewed scenarios, which span a range of policy and technology assumptions, include at least a doubling of the transmission system by 2050. The national studies find substantial net system cost savings from transmission expansion and high benefit-cost ratios for transmission investments. The results are derived through multi-value, nationally coordinated, co-optimized, multi-scenario modeling, which is an approach that could yield lower-cost pathways compared to current industry planning practices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transmission-distribution long-term volt-var planning considering reactive power support capability of distributed PV

High penetration of grid-edge, inverter-based photovoltaic (PV) can cause significant voltage fluctuations not only at the distribution but also at the sub-transmission levels due to PV output intermittency. Traditional reactive power planning approaches do not consider intermittency, nor the possibility of coordinating the control of existing and future volt-ampere reactive resources. This paper proposes a reactive power planning tool for sub-transmission systems to mitigate voltage violations and fluctuations caused by high PV penetration and intermittency with a minimum investment cost. The planning tool coordinates with an optimization-based volt-var operational tool for: a) modeling the coordination of all existing var assets in both sub-transmission and distribution systems to reduce the need of new equipment, and b)selecting a set of scenarios with voltage violations, derived from PV intermittency c) testing the final investment decision. The tool obtains an investment need for each intermittency scenario with a proposed optimal power-flow framework with efficient techniques to handle a high number of discrete variables. Two options are provided for final planning decision: i) a conservative direct combination of investment need solutions and ii) a machine learning-based selection of representative investment needs at most time steps. The final investment decision options are verified using a realistic large-scale sub-transmission system and 5-minute PV and load data. The results show a significant voltage performance improvement with a lower investment cost for additional var equipment compared to conventional approaches.

14 SOLAR ENERGY↗

Enhanced Power Grid Maintenance Planning and Quantum-Inspired Combinatorial Prospects

Efficient and reliable scheduling of maintenance for power generation and transmission infrastructure is essential for minimizing operational costs and ensuring grid stability. This paper introduces an integrated optimization framework for coordinated maintenance scheduling of generators and transmission lines under resource and reliability constraints. The model minimizes a composite cost function including maintenance and generation costs, as well as penalties for delayed maintenance, while satisfying N−1 security constraints, operational limits, and crew availability. Case studies on the IEEE 300-bus test system demonstrate the effectiveness of the proposed approach in producing feasible and cost-effective maintenance schedules. To address scalability and combinatorial complexity, the model is mapped into a Quadratic Unconstrained Binary Optimization (QUBO) problem, enabling exploration of solution approaches based on Quantum Imaginary Time Evolution (QITE). While the QUBO reformulation provides a foundation for future quantum-inspired optimization, this study focuses primarily on the development and demonstration of the classical optimization framework and illustrates the potential applicability of QITE in large-scale maintenance scheduling.

Chen, Yang [ORNL] (ORCID:0000000271693874)↗

Enabling Structure/Interface Regulation for High Performance Ni-Rich Cathodes

Here, further commercialization of Ni-rich layered cathodes is hindered by severe structure/interface degradation and kinetic hindrance that occur during electrochemical operation, which leads to safety risks and reduced range in electric vehicles (EVs). Herein, by selecting elements with different solubility properties, a multifunctional strategy that synchronously fabricates perovskite-type SrZrO 3 coating and Sr/Zr co-doping is employed to strengthen the structure/interface stability and the Li + transport mobility of LiNi 0.85 Co 0.10 Mn 0.05 O 2 (NCM). Perovskite-type SrZrO 3 protective layers formed on the particle surface can substantially mitigate the unexpected interfacial side reactions and surface phase transitions. In addition, a robust crystal framework is constructed by optimizing local O coordination through the introduction of strong Zr-O bonds. Notably, Li + diffusion kinetics is effectively improved due to expanded cell parameters and O-Li-O slab spacing with the incorporation of large-diameter Sr pillar ions, as revealed by X-ray diffraction. As a result, the Sr/Zr-modified NCM achieves a remarkable capacity retention of 99.4% after 200 cycles at 1 C, and a high rate capacity of 168.9 mAh g -1 at 10 C. This work opens new avenues to develop high-performance NCM cathodes with high energy and high power for EVs with long calendar life.

25 ENERGY STORAGE↗

Assessing the performance of global thermostat adjustment in commercial buildings for load shifting demand response

Abstract Efficiently leveraging new sources of flexibility is critical to mitigating load balancing challenges posed by variable renewable resources. The thermal inertia of commercial buildings allows us to shift their power consumption on minute to hourly timescales to provide demand response to the grid while maintaining occupant comfort. Global thermostat adjustment (GTA) provides a readily available and scalable approach for implementing load shifting demand response using commercial heating, ventilation, and air conditioning (HVAC) systems, since it leverages the inherent sophistication of modern building automation systems. However, there is an incomplete understanding of GTA’s performance for this purpose and its impact on building systems and occupant comfort. In this paper, we explore the performance of GTA by analyzing results from nearly nine hundred experiments on eight university campus buildings in Michigan and North Carolina. Using GTA, we manipulate each building’s thermostat setpoints causing the building to shift its power consumption with respect to its baseline. We quantify the magnitude of HVAC power response, energy use of HVAC subsystems, and impact on occupant comfort. Finally, we connect our experimental results with power system operation using an optimization model that coordinates GTA actions across a large collection of grid-interactive efficient buildings (GEBs) to reduce high ramp rates on the grid and mitigate renewable energy curtailment. Overall, our work finds that the impacts on HVAC subsystems are often complex, and may result in additional energy being consumed by fans and terminal reheat. These effects must be considered when using GTA for load shifting. Additionally, we demonstrate that occupant comfort, as assessed by indoor temperature and humidity, can be maintained during GTA events. From a societal perspective, our modeling work finds that the additional renewable energy that can be integrated through the use of GTA strategies eclipses any additional energy consumed by buildings.

Keskar, Aditya (ORCID:0000000244617980)↗

Framework for X-ray mirror surface shape fitting

For accurate characterization of grazing-incidence X-ray mirrors, we present a comprehensive framework to fit measured surface shapes (either slope or height) of X-ray mirrors used in synchrotron radiation and free-electron laser facilities. We summarize the closed-form expressions of some typical surface shapes of X-ray mirrors including elliptic cylinders, hyperbolic cylinders, ellipsoids, hyperboloids, and diaboloids. This framework is composed of four layers: definition of standard shapes with closed-form expressions, generation of theoretical surface with pose parameters (six degrees of freedom defining an object's position and orientation relative to a coordinate system), parameter optimization with the ability to select which parameters are fit and which are held constant, and the development of user-friendly fitting function wrappers for particular fitting tasks. A few practical fitting examples are demonstrated to verify the effectiveness of the proposed fitting framework. We discuss the physical meanings of the fitting parameters, and provide several examples using the elliptic cylinder and ellipsoid shapes to highlight some features of the framework. Moreover, we provide the presented framework as open-source codes (MATLAB and Python codes available at https://github.com/nsls2omf/xmf) to the community to encourage academic collaboration and further improvements.

36 MATERIALS SCIENCE↗

Phasor Based Control with the Distributed, Extensible Grid Control Platform

This paper describes how to implement Phasor Based Control (PBC) using the Distributed, Extensible Grid Control (DEGC) Platform. PBC is a novel method for controlling distributed energy resources (DER) that coordinates a centralized optimization with distributed feedback controllers to enforce voltage phasor targets. DEGC is an open source software and communication platform designed for general DER control. We deployed PBC at Lawrence Berkeley Lab's FLEXLAB test site, conducting multiple hardware-in-the-loop test runs. Here, we describe how DEGC was used to implement PBC on hardware, and results demonstrating successful deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Framework for Multi Layer Control in Python (FMLC) v1.0

This package is developed as a backend for multi-layer and multi-time domain controller. One example are controller based on [Model Predictive Control] (MPC) where different modules with different time constants have to be coordinated to allow optimal control. In a simple example, the Weather Forecast must be acquired and processed, the MPC is computed, and finally the control is applied. All these modules typically run on the same time step (Time step: 5 minutes), but are different instances within the framework. The framework allows parallelization using the `multiprocessing` module. However, another real-time controller (Time step: 1 second) must be applied to react on instant system disturbances beyond the MPC time step. Last, a supervisory MPC controller (Time step: 1 hour) might be added to ensure global optimality.

Gehbauer, Christoph↗

Advanced Computational Techniques for Improving Resilience of Critical Energy Infrastructure under Cyber-Physical Attacks

In this chapter, we present recent advances in improving the resilience of cyber-physical systems, especially with regards to energy systems. We provide discussions around various types of cyber-physical events that can cause disruptions and new advances in optimization, control, and reinforcement learning (RL) to deal with the challenges posed by such cyber-physical events. The presented methods range from distributed robust optimization, autonomous and coordinated control, reinforcement learning based resilient control and topology reconfiguration in Inter-System resilient control.

Nazir, Mohammad Nawaf [BATTELLE (PACIFIC NW LAB)]↗

Cooperative Automated Cohort Driving on Connected Infrastructure, Arterial Roadways, and Highways: Final Project Demonstration and System-of-Systems Model Correlation

This project seeks to synergize vehicle automated driving and connectivity data to improve mobility and energy efficiency of groups of mixed vehicles operating in close proximity (vehicle cohort) on various infrastructure. A custom cellular communication network links vehicles operating as a cohort with infrastructure to a centralized system-of-systems digital twin with an AI-based optimal behavior planner. The data contained in this set are from final testing and technology demonstrations to U.S. Department of Energy staff at the American Center for Mobility. The data contain single-lane, single-light scenarios; multi-lane, multi-light arterial scenarios; and limited-access highway scenarios. All test cases were derived from simulations and replicated on the test track. The project employed two and four light-duty vehicles with connectivity and drive automation for the testing. The baseline scenario without connectivity was run under the control of the system-of-systems centralized planner but operating each vehicle with an intelligent driver model controlling the velocity, lane utilization, and vehicle gap. This was to ensure the highest compatibility with the simulation in terms of dynamic behavior. The connected cohort case utilized AI optimization to perform coordinated and cooperative control for energy, as well as safe, comfortable behavior for the cohort. The dataset is appropriately named with unconnected and connected designations, with comparisons sharing the same run index number. The included PowerPoint and PDF files describe the test setup and provide an overview of results from the project. ![image](de-EE0009209_March_2023_Data_Arterial_Scenario_Results.png)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A hybrid architecture for volt-var control in active distribution grids

Modern active distribution grids are characterized by the increasing penetration of distributed energy resources (DERs). The proper coordination and scheduling of a large numbers of these small-scale and spatially distributed DERs is necessary, and warrants the use of novel distributed approaches. In this paper, we propose a hybrid volt-var control architecture for the distribution grid, which leverages existing centralized and local approaches to planning, decision making, and control, and augments it with distributed optimization and distributed control for DER management. First, we propose a convex model to describe the power physics of distribution grids of meshed topology and unbalanced structure, based on current injection and McCormick Envelopes. Second, we employ the distributed proximal atomic coordination (PAC) algorithm to coordinate DERs to provide voltage support. We implement volt-var optimization by optimally coordinating DERs including PV smart inverters and demand response. We present results using the IEEE-34 bus network, using real data from a distribution feeder in Hawaii, to model load and PV generation. Different levels of DER penetration and objective functions are simulated. Finally, our results show the need for the coordination of DERs to improve voltage profiles, even in networks with existing voltage control devices. Further, we show the need for flexible reactive power capabilities to achieve desired grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Control for Fast Frequency Response and Black-Start using Embedded Storages with Grid-Forming Control

The grid-forming inverter is regarded as the solution for integrating high levels of renewable resources into future power systems. Ensuring the stable operation of grids necessitates that grid-forming inverters offer fast frequency response. This report introduces an optimal control method that coordinates the embedded storage within the grid-forming control model with conventional synchronous generators. The optimized active power reference for the embedded storage is generated using receding horizon optimization control, aiming to keep the center of inertia frequency within acceptable limits. The effectiveness of the proposed control is verified through testing in the IEEE 39-bus system. In addition, with grid-forming capability, we will also investigate the application of using mobile embedded storages as black-start units to provide cranking power to energize non-blackstart generators in a black-start process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Economical and Engineering Aspects of Proactive Demand Participation: Centralized versus Bilateral Control Structure

The electric grid of the U.S. is evolving from a system characterized by large and centralized fossil-fueled power plants and passive customers to a network with high penetration of distributed energy resources and proactive customers. This project facilitated the evolution of the U.S. electric power grid by enabling proactive participation of demands in electricity market at the power distribution system level. This project has three major achievements. First, we designed a centralized distribution system operator managed electricity market and developed a three-phase alternating current optimal power flow algorithm to coordinate the operation of large-scale flexible loads and distributed energy resources. Second, we designed a decentralized bilateral coordinate framework for retail electricity market, where each participating customer is capable of making decisions regarding energy production and consumption based on information received from transactive neighbors. Third, the impacts of centralized and decentralized demand-side participation scheme on power system operations were evaluated with both large-scale simulations and hardware-in-the-loop demonstrations. The major activities and specific accomplishments of the technical tasks are summarized in Section II. The detailed design of centralized/hierarchical and decentralized/bilateral retail electricity markets and the comparison between the two markets are described in Section III. The accomplishments and conclusions of the project are presented in Section IV. The major findings of the project falls into three areas, hierarchical distribution system operator managed electricity market, bilateral electricity market and decentralized market coordination, and comparison of centralized and decentralized market coordination mechanisms. In the area of hierarchical distribution system operator managed electricity market design, an integrated wholesale and retail electricity market was shown to be highly effective in extracting the operational flexibility from distributed energy resources to provide services to the wholesale market. A chordal conversion based convex iteration algorithm is not only computationally efficiency but also achieves global optimal solution in coordinating the operations of a large number of heterogeneous distributed energy resources.In the area of decentralized market coordination approach, we showed that bilateral transactions among proactive customers and decentralized transaction clearing mechanism based on simultaneous second-price sealed-bid auction can encourage truthful bidding strategies from the market participations. In addition, the individual customers can rely on a portfolio optimization approach to maximize their returns while minimizing risks. In the area of comparison of centralized and decentralized market coordination mechanisms, we found that the centralized market design results in higher social welfare and lower wholesale market clearing price for electricity. In general, centralized market design favors distributed energy resources and fixed loads. The decentralized market design mostly benefits flexible loads and conventional generators.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗