Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

New Internet search volume-based weighting method for integrating various environmental impacts

Weighting is one of the steps in life cycle impact assessment that integrates various characterized environmental impacts as a single index. Weighting factors should be based on the society's preferences. However, most previous studies consider only the opinion of some people. Thus, this research proposes a new weighting method that determines the weighting factors of environmental impact categories by considering public opinion on environmental impacts using the Internet search volumes for relevant terms. To validate the new weighting method, the weighting factors for six environmental impacts calculated by the new weighting method were compared with the existing weighting factors. The resulting Pearson's correlation coefficient between the new and existing weighting factors was from 0.8743 to 0.9889. It turned out that the new weighting method presents reasonable weighting factors. It also requires less time and lower cost compared to existing methods and likewise meets the main requirements of weighting methods such as simplicity, transparency, and reproducibility. The new weighting method is expected to be a good alternative for determining the weighting factor. - Highlight: • A new weighting method using Internet search volume is proposed in this research. • The new weighting method reflects the public opinion using Internet search volume. • The correlation coefficient between new and existing weighting factors is over 0.87. • The new weighting method can present the reasonable weighting factors. • The proposed method can be a good alternative for determining the weighting factors.

54 ENVIRONMENTAL SCIENCES↗

Spatial and temporal agreement in climate model simulations of the Interdecadal Pacific Oscillation

Accelerated warming and hiatus periods in the long-term rise of Global Mean Surface Temperature (GMST) have, in recent decades, been associated with the Interdecadal Pacific Oscillation (IPO). Critically, decadal climate prediction relies on the skill of state-of-the-art climate models to reliably represent these low-frequency climate variations. We undertake a systematic evaluation of the simulation of the IPO in the suite of Coupled Model Intercomparison Project 5 (CMIP5) models. We track the IPO in pre-industrial (control) and all-forcings (historical) experiments using the IPO tripole index (TPI). The TPI is explicitly aligned with the observed spatial pattern of the IPO, and circumvents assumptions about the nature of global warming. We find that many models underestimate the ratio of decadal-to-total variance in sea surface temperatures (SSTs). However, the basin-wide spatial pattern of positive and negative phases of the IPO are simulated reasonably well, with spatial pattern correlation coefficients between observations and models spanning the range 0.4–0.8. Deficiencies are mainly in the extratropical Pacific. Models that better capture the spatial pattern of the IPO also tend to more realistically simulate the ratio of decadal to total variance. Of the 13% of model centuries that have a fractional bias in the decadal-to-total TPI variance of 0.2 or less, 84% also have a spatial pattern correlation coefficient with the observed pattern exceeding 0.5. This result is highly consistent across both IPO positive and negative phases. This is evidence that the IPO is related to one or more inherent dynamical mechanisms of the climate system.

54 ENVIRONMENTAL SCIENCES↗

On/Off State Classification of a Reactor Facility Using Gas Effluence Measurements

Inferring on/off operational state of a reactor facility using measurements from an independent monitoring system is critical to the assessment of its compliance to agreements. In this paper, we consider the problem of inferring on/off state of a reactor facility using measurements of Ar-41, Cs-138, and Xe-138 gas effluence types collected at the facility’s off-gas stack. We present classifiers based on thresholding measurements of individual effluence types, and then present fusers that combine their outputs or measurements. We present five fusers based on simple majority rule, Chow’s pattern recognition function, Fisher’s combined p-value statistic, physics-based Poisson radiation counts model, and correlation coefficient method. In addition, we also test five machine learning methods based on non-linear classifiers, which are available as R packages. Finally, our results show that: (i) these gas effluence measurements are effective in inferring on/off state of a reactor facility; for example, best fusers achieve ~97% detection at ~1% false alarm rate, and (ii) fusers that combine all effluence types based on physics-based models, correlation coefficient and Fisher’s method outperform simple majority rule, Chow’s fusers and machine learning methods, as well as when they are applied to individual and pairs of effluence types.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Estimation of total cloud cover from solar radiation observations at Lake Rotorua, New Zealand

The DYRESM-CAEDYM model is a valuable tool for simulating water temperature for biochemical studies in aquatic ecosystem. The model requires inputs of surface short-wave radiation and long-wave radiation or total cloud cover fraction (TC). Long-wave radiation is often not measured directly so a method to determine TC from commonly measured short-wave solar irradiance (E{sub 0}) and theoretical short-wave solar irradiance under a clear sky (E{sub c}) has broad application. A more than 17-year (15 November 1991 to 20 February 2009) hourly solar irradiance data set was used to estimate the peak solar irradiance for each ordinal date over one year, which was assumed to be representative of solar irradiance in the absence of cloud. Comparison between these daily observed values and the modelled clear-sky solar radiation over one year was in close agreement (Pearson correlation coefficient, r = 0.995 and root mean squared error, RMSE = 12.54 W m{sup -2}). The downloaded hourly cloudiness measurements from 15 November 1991 to 20 February 2009 was used to calculate the daily values for this period and then the calculated daily values over the 17 years were used to calculate the average values for each ordinal date over one year. A regression equation between (1 - E{sub 0}/E{sub c}) and TC produced a correlation coefficient value of 0.99 (p > 0.01, n = 71). The validation of this cloud cover estimation model was conducted with observed short-wave solar radiation and TC at two sites. Values of TC derived from the model at the Lake Rotorua site gave a reasonable prediction of the observed values (RMSE = 0.10, r = 0.86, p > 0.01, n = 61). The model was also tested at Queenstown (South Island of New Zealand) and it provided satisfactory results compared to the measurements (RMSE = 0.16, r = 0.67, p > 0.01, n = 61). Therefore the model's good performance and broad applicability will contribute to the DYRESM-CAEDYM accuracy of water temperature simulation when long-wave radiation is not available. (author)

14 SOLAR ENERGY↗

Measurement of regional compliance using 4DCT images for assessment of radiation treatment

Purpose: Radiation-induced damage, such as inflammation and fibrosis, can compromise ventilation capability of local functional units (alveoli) of the lung. Ventilation function as measured with ventilation images, however, is often complicated by the underlying mechanical variations. The purpose of this study is to present a 4DCT-based method to measure the regional ventilation capability, namely, regional compliance, for the evaluation of radiation-induced lung damage. Methods: Six 4DCT images were investigated in this study: One previously used in the generation of a POPI model and the other five acquired at Henry Ford Health System. A tetrahedral geometrical model was created and scaled to encompass each of the 4DCT image domains. Image registrations were performed on each of the 4DCT images using a multiresolution Demons algorithm. The images at the end of exhalation were selected as a reference. Images at other exhalation phases were registered to the reference phase. For the POPI-modeled patient, each of these registration instances was validated using 40 landmarks. The displacement vector fields (DVFs) were used first to calculate the volumetric variation of each tetrahedron, which represents the change in the air volume. The calculated results were interpolated to generate 3D ventilation images. With the computed DVF, a finite element method (FEM) framework was developed to compute the stress images of the lung tissue. The regional compliance was then defined as the ratio of the ventilation and stress values and was calculated for each phase. Based on iterative FEM simulations, the potential range of the mechanical parameters for the lung was determined by comparing the model-computed average stress to the clinical reference value of airway pressure. The effect of the parameter variations on the computed stress distributions was estimated using Pearson correlation coefficients. Results: For the POPI-modeled patient, five exhalation phases from the start to the end of exhalation were denoted by P{sub i}, i=1,...,5, respectively. The average lung volume variation relative to the reference phase (P{sub 5}) was reduced from 18% at P{sub 1} to 4.8% at P{sub 4}. The average stress at phase P{sub i} was 1.42, 1.34, 0.74, and 0.28 kPa, and the average regional compliance was 0.19, 0.20, 0.20, and 0.24 for i=1,...,4, respectively. For the other five patients, their average R{sub v} value at the end-inhalation phase was 21.1%, 19.6%, 22.4%, 22.5%, and 18.8%, respectively, and the regional compliance averaged over all six patients is 0.2. For elasticity parameters chosen from the potential parameter range, the resultant stress distributions were found to be similar to each other with Pearson correlation coefficients greater than 0.81. Conclusions: A 4DCT-based mechanical model has been developed to calculate the ventilation and stress images of the lung. The resultant regional compliance represents the lung's elasticity property and is potentially useful in correlating regions of lung damage with radiation dose following a course of radiation therapy.

60 APPLIED LIFE SCIENCES↗

The formation of correlated states and optimization of the tunnel effect for low-energy particles under nonmonochromatic and pulsed action on a potential barrier

We consider peculiarities of the formation of a coherent correlated state (CCS) of a low-energy particle under frequency modulation of parameters of a harmonic oscillator that contains this particle by a broadband nonmonochromatic or asymmetric pulsed action. It is shown that in the case of modulation with frequency-normalized intensity, the maximum efficiency of CCS formation corresponds to a narrow-band action, while broadband modulation is optimal for the action with a constant spectral density. As in the case of monochromatic modulation, the maximum correlation coefficient, |r|{sub max}, under the nonmonochromatic action corresponds to parametric resonance at frequency Ω ≈ 2ω{sub 0}. Under a pulsed action, the maximum efficiency of CCS formation and, hence, the maximum probability of the tunnel effect, correspond to pulsed modulation with a short leading edge and a long trailing edge. In particular, under the action of a pulsed magnetic field with an amplitude of 10 kOe and the leading edge duration of 2 × 10{sup –7} s on a gas with deuterium ions, a CCS can be formed with the correlation coefficient |r|{sub max} ≈ 0.9998, for which the tunneling effect probability under the dd interaction at temperature T ≈ 300–500 K increases from D{sub r=0} ≈ 10{sup −80} to D{sub |r|{sub m{sub a{sub x=0.9998}}}}≈0.1. This process can occur in a gas with particle number density n < n{sub cr} ≈ 10{sup 17} cm{sup −3}. The method of CCS formation makes it possible to explain the results of an experiment in which substantial isotope changes were detected when a pulsed electric current and magnetic-field generation occurred.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Locoregional Control of Non-Small Cell Lung Cancer in Relation to Automated Early Assessment of Tumor Regression on Cone Beam Computed Tomography

Purpose: Large interindividual variations in volume regression of non-small cell lung cancer (NSCLC) are observable on standard cone beam computed tomography (CBCT) during fractionated radiation therapy. Here, a method for automated assessment of tumor volume regression is presented and its potential use in response adapted personalized radiation therapy is evaluated empirically. Methods and Materials: Automated deformable registration with calculation of the Jacobian determinant was applied to serial CBCT scans in a series of 99 patients with NSCLC. Tumor volume at the end of treatment was estimated on the basis of the first one third and two thirds of the scans. The concordance between estimated and actual relative volume at the end of radiation therapy was quantified by Pearson's correlation coefficient. On the basis of the estimated relative volume, the patients were stratified into 2 groups having volume regressions below or above the population median value. Kaplan-Meier plots of locoregional disease-free rate and overall survival in the 2 groups were used to evaluate the predictive value of tumor regression during treatment. Cox proportional hazards model was used to adjust for other clinical characteristics. Results: Automatic measurement of the tumor regression from standard CBCT images was feasible. Pearson's correlation coefficient between manual and automatic measurement was 0.86 in a sample of 9 patients. Most patients experienced tumor volume regression, and this could be quantified early into the treatment course. Interestingly, patients with pronounced volume regression had worse locoregional tumor control and overall survival. This was significant on patient with non-adenocarcinoma histology. Conclusions: Evaluation of routinely acquired CBCT images during radiation therapy provides biological information on the specific tumor. This could potentially form the basis for personalized response adaptive therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of aerosol vertical profiles on satellite-estimated surface particle sulfate concentrations

The aerosol vertical distribution is an important factor in determining the relationship between satellite retrieved aerosol optical depth (AOD) and ground-level fine particle pollution concentrations. We evaluate how aerosol profiles measured by ground-based lidar and simulated by models can help improve the association between AOD retrieved by the Multi-angle Imaging Spectroradiometer (MISR) and fine particle sulfate (SO4) concentrations using matched data at two lidar sites. At the Goddard Space Flight Center (GSFC) site, both lidar and model aerosol profiles marginally improve the association between SO4 concentrations and MISR fractional AODs, as the correlation coefficient between cross-validation (CV) and observed SO4 concentrations changes from 0.87 for the no-scaling model to 0.88 for models scaled with aerosol vertical profiles. At the GSFC site, a large amount of urban aerosols resides in the well-mixed boundary layer so the column fractional AODs are already excellent indicators of ground-level particle pollution. In contrast, at the Atmospheric Radiation Measurement Program (ARM) site with relatively low aerosol loadings, scaling substantially improves model performance. The correlation coefficient between CV and observed SO4 concentrations is increased from 0.58 for the no-scaling model to 0.76 in the GEOS-Chem scaling model, and the model bias is reduced from 17% to 9%. In summary, despite the inaccuracy due to the coarse horizontal resolution and the challenges of simulating turbulent mixing in the boundary layer, GEOS-Chem simulated aerosol profiles can still improve methods for estimating surface aerosol (SO4) mass from satellite-based AODs, particularly in rural areas where aerosols in the free troposphere and any long-range transport of aerosols can significantly contribute to the column AOD.

54 ENVIRONMENTAL SCIENCES↗

Characterization of the quantum state of top quark pairs produced in proton-proton collisions at $\sqrt{s}$ = 13 TeV using the beam and helicity bases

Measurements of the spin correlation coefficients in the beam basis are presented for top quark-antiquark $(t\bar{t}⁢)$ systems produced in proton-proton collisions at $\sqrt{s}$ = 13 TeV collected by the CMS experiment in 2016–2018, and corresponding to an integrated luminosity of 138 fb −1 . The $t\bar{t}$ system is reconstructed from final states containing an electron or muon and jets. Together with the previously reported results in the helicity basis, these measurements are used to decompose the system into the Bell and spin eigenstates in various kinematic regions. The spin correlation coefficients are also used to evaluate properties of the $t\bar{t}$ quantum state, such as the purity, von Neumann entropy, and entanglement. All results are consistent with standard model predictions.

Hayrapetyan, Aram [Yerevan Physics Institute]↗

R2 relaxometry based MR imaging for estimation of liver iron content: A comparison between two methods

Purpose: To compare the reproducibility and accuracy of R2-relaxometry MRI for estimation of liver iron concentration (LIC) between in-house analysis and FDA-approved commercially available third party results. Methods: All MR studies were performed on a 1.5T scanner. Multi-echo spin-echo scans with a fixed TR and increasing TE values of 6 ms, 9 ms, 12 ms, 15 ms, and 18 ms (spaced at 3 ms intervals) were used. Post-processing of the images to calculate mean relaxivity, R2, included drawing of regions of interest to include the whole liver on mid-slice. The relationship between liver R2 values and estimated LIC calculated with in-house analysis and values reported by an external company (FerriScan{sup ®}, Resonance Health, Australia) were assessed with correlation coefficients and Bland–Altman difference plots. Continuous variables are presented as mean ± standard deviation. Significance was set at p value < 0.05. Results: 474 studies from 175 patients were included in the study (mean age 10.4 ± 4.2 years (range 1–18 years); 254 studies from girls, 220 studies from boys). LIC ranged from 0.6 to 43 mg/g dry tissue, covering a broad range from normal levels to extremely high iron levels. Linearity between proprietary and in-house methods was excellent across the observed range for R2 (31.5 to 334.8 s{sup −1}); showing a correlation coefficient of r = 0.87, p < 0.001. Bland–Altman R2 difference plot between the two methods shows a mean bias of + 21.5 s{sup −1} (range − 47.0 to + 90.0 s{sup −1} between two standard deviations). LIC reported by FerriScan{sup ®} compared with LIC estimated in-house with R2 as reported by FerriScan{sup ®} agreed strongly, (r = 1.0, p < 0.001). Conclusion: R2 relaxometry MR imaging for liver iron concentration estimation is reproducible between proprietary FDA-approved commercial software and in-house analysis methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Arctic Amplification in the Community Earth System Models (CESM1 and CESM2)

We compare the Arctic amplification (AA) produced by the two Community Earth System Models CESM1 and CESM2, members of the CEMIP5 (Coupled Models Intercomparison Project phase 5) and CEMIP6 collections, respectively. We find that the CESM1 model reproduces the recent high values of the AA deduced from the observed temperature much better than the CESM2. The correlation coefficient within the 1970–2012 time period between CESM1-simulated AA and the observed one is 0.47, while the CESM2 simulation leads to an anticorrelation of r = –0.53. Even the more successful model (CESM1) is not able to reproduce recent high AA values of 4–5. The main cause of this failure is the model’s overestimate of the rate of increase in the mean global temperature in years post 1990. When the CESM1 model’s simulated trend of the mean global temperature is replaced in the expression for the AA by the observed temperature trend, the correlation coefficient increases from 0.47 to 0.75. The CESM1 model is among the best north American models in AA simulation while the CESM2 model is among the least successful.

54 ENVIRONMENTAL SCIENCES↗

Aerosol and cloud microphysics covariability in the northeast Pacific boundary layer estimated with ship-based and satellite remote sensing observations: NE Pacific Aerosol-Cloud Interactions

Ship measurements collected over the northeast Pacific along transects between the port of Los Angeles (33.7°N, 118.2°W) and Honolulu (21.3°N, 157.8°W) during May to August 2013 were utilized to investigate the covariability between marine low cloud microphysical and aerosol properties. Ship-based retrievals of cloud optical depth (τ) from a Sun photometer and liquid water path (LWP) from a microwave radiometer were combined to derive cloud droplet number concentration Nd and compute a cloud-aerosol interaction (ACI) metric defined as ACICCN = ∂ ln(Nd)/∂ ln(CCN), with CCN denoting the cloud condensation nuclei concentration measured at 0.4% (CCN0.4) and 0.3% (CCN0.3) supersaturation. Analysis of CCN0.4, accumulation mode aerosol concentration (Na), and extinction coefficient (σext) indicates that Na and σext can be used as CCN0.4 proxies for estimating ACI. ACICCN derived from 10 min averaged Nd and CCN0.4 and CCN0.3, and CCN0.4 regressions using Na and σext, produce high ACICCN: near 1.0, that is, a fractional change in aerosols is associated with an equivalent fractional change in Nd. ACICCN computed in deep boundary layers was small (ACICCN = 0.60), indicating that surface aerosol measurements inadequately represent the aerosol variability below clouds. Satellite cloud retrievals from MODerate-resolution Imaging Spectroradiometer and GOES-15 data were compared against ship-based retrievals and further analyzed to compute a satellite-based ACICCN. Satellite data correlated well with their ship-based counterparts with linear correlation coefficients equal to or greater than 0.78. Combined satellite Nd and ship-based CCN0.4 and Na yielded a maximum ACICCN = 0.88–0.92, a value slightly less than the ship-based ACICCN, but still consistent with aircraft-based studies in the eastern Pacific.

Painemal, David↗

Analyzing the impact of intrafraction motion: Correlation of different dose metrics with changes in target D{sub 95%}

Purpose: A number of techniques are available to determine the dosimetric impact of intrafraction motion during intensity modulated radiation therapy (IMRT). Motion-induced dose perturbations can be determined both computationally and experimentally using a number of different dosimetric metrics. However, these measures may lead to different conclusions regarding the clinical impact of motion. This study compares the analysis of identical dose perturbations using different dosimetric metrics. Calculated changes in target D{sub 95%} are used as a reference. Methods: A total of 3768 motion-encoded dose distributions were calculated for nine lung tumor patients. The motion-encoded dose distributions were compared to static dose distributions using three dosimetric metrics: 2D {gamma}, 3D {gamma}, and histogram analysis. Each of these metrics was used to analyze dose perturbations both globally and within the target structure. Furthermore, the failing voxels were analyzed separately according to failure mode, i.e., under vs. over-dosed voxels. Metrics were evaluated based on their agreement with changes in target D{sub 95%}. Evaluations included the metrics' maximum average sensitivity and specificity (MASS) in detecting unacceptable deliveries, a coefficient correlated to ranking ({tau}), and the linear correlation coefficient, r. Results: Of the evaluated metrics, the histogram metric restricted to the under-dosed voxels within the target agreed best with changes in target D{sub 95%}. This metric achieved a MASS of 0.93, a {tau} of 0.69, and an r-value of 0.85. In comparison, the unrestricted 2D {gamma} metric achieved MASS = 0.77, {tau} = 0.40, and r = 0.67. Restricting the 2D {gamma} test both geographically and in failure mode increased the MASS to 0.85, {tau} to 0.70, and the r-value to 0.80. Conclusions: This study suggests that any clinical decisions based solely on an unrestricted 2D {gamma} metric are suboptimal. A geographic and failure mode restriction can improve results. The remaining uncertainties with non-DVH (dose volume histogram) based metrics should be kept in mind when they are used to evaluate the dosimetric impact of target motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying Leaf Chlorophyll Concentration of Sorghum from Hyperspectral Data Using Derivative Calculus and Machine Learning

Leaf chlorophyll concentration (LCC) is an important indicator of plant health, vigor, physiological status, productivity, and nutrient deficiencies. Hyperspectral spectroscopy at leaf level has been widely used to estimate LCC accurately and non-destructively. This study utilized leaf-level hyperspectral data with derivative calculus and machine learning to estimate LCC of sorghum. We calculated fractional derivative (FD) orders starting from 0.2 to 2.0 with 0.2 order increments. Additionally, 43 common vegetation indices (VIs) were calculated from leaf spectral reflectance factor to make comparisons with reflectance-based data. Within the modeling pipeline, three feature selection methods were assessed: Pearson’s correlation coefficient (PCC), partial least squares based variable importance in the projection (VIP), and random forest-based mean decrease impurity (MDI). Finally, we used partial least squares regression (PLSR), random forest regression (RFR), support vector regression (SVR), and extreme learning regression (ELR) to estimate the LCC of sorghum. Results showed that: (1) increasing derivative order can show improved model performance until certain order for reflectance-based analysis; however, it is inconclusive to state that a particular order is optimal for estimating LCC of sorghum; (2) VI-based modeling outperformed derivative augmented reflectance factor-based modeling; (3) mean decrease impurity was found effective in selecting sensitive features from large feature space (reflectance-based analysis), whereas simple Pearson’s correlation coefficient worked better with smaller feature space (VI-based analysis); and (4) SVR outperformed all other models within reflectance-based analysis; alternatively, ELR with VIs from original reflectance yielded slightly better results compared to all other models.

47 OTHER INSTRUMENTATION↗

A framework to measure myocardial extracellular volume fraction using dual-phase low dose CT images

Purpose: Myocardial extracellular volume fraction (ECVF) is a surrogate imaging biomarker of diffuse myocardial fibrosis, a hallmark of pathologic ventricular remodeling. Low dose cardiac CT is emerging as a promising modality to detect diffuse interstitial myocardial fibrosis due to its fast acquisition and low radiation; however, the insufficient contrast in the low dose CT images poses great challenge to measure ECVF from the image. Methods: To deal with this difficulty, the authors present a complete ECVF measurement framework including a point-guided myocardial modeling, a deformable model-based myocardium segmentation, nonrigid registration of pre- and post-CT, and ECVF calculation. Results: The proposed method was evaluated on 20 patients by two observers. Compared to the manually delineated reference segmentations, the accuracy of our segmentation in terms of true positive volume fraction (TPVF), false positive volume fraction (FPVF), and average surface distance (ASD), were 92.18% ± 3.52%, 0.31% ± 0.10%, 0.69 ± 0.14 mm, respectively. The interobserver variability measured by concordance correlation coefficient regarding TPVF, FPVF, and ASD were 0.95, 0.90, 0.94, respectively, demonstrating excellent agreement. Bland-Altman method showed 95% limits of agreement between ECVF at CT and ECVF at MR. Conclusions: The proposed framework demonstrates its efficiency, accuracy, and noninvasiveness in ECVF measurement and dramatically advances the ECVF at cardiac CT toward its clinical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of the Spin Correlation in the Top Quark Pair Production using the Dilepton Events in 1.96-TeV Proton-Antiproton Collisions

One of the most remarkable properties of the top quark is its extremely short lifetime, which allows us to observe the top quark spin at its production. That means a spin correlation at $t\bar{t}$ production is possible to be observed. In this thesis, we report on a measurement of the correlation coefficient between top quark spin and antitop quark spin in the beam basis at top quark pair production. We select $t\bar{t}$ pair production candidates by requiring two high transverse momentum leptons, two jets and large missing $E_T$ . In order to reconstruct the angular distribution of top quark decay products, we perform full kinematical reconstruction using predicted distributions of $p^{t\bar{t}}_z$ , $p^{t\bar{t}}_T$ and $M_{t\bar{t}}$. We make signal and background templates from admixture of Monte Carlo simulations and data-based background modelings. Then, we perform unbinned likelihood fit of angular distribution of data to signal and background templates and obtain result. This analysis is based on the data of 5.1 $fb^{-1}$ collected with the Collider Detector Facility (CDF) at the Fermilab Tevatron between March 2002 and June 2009. We observe 334 $t\bar{t}$ candidate events. We determine a confidence interval at 68% level for the correlation coefficient $\kappa$ to be -0.520 < $\kappa$ < 0.605 or $\kappa$ = $0.042^{+0.563}_{-0.562}$ on the assumption of $M_{top}$ = 172.5 GeV/$c^2$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diamonds in the rough: a strong case for the inclusion of weak-intensity X-ray diffraction data

Here, new evidence is provided to show that the inclusion of weak-intensity, high-resolution X-ray diffraction data helps to improve the quality of experimental phases by imposing proper constraints on electron-density models during noncrystallographic symmetry averaging. Overwhelming evidence exists to show that the inclusion of weak-intensity, high-resolution X-ray diffraction data helps improve the refinement of atomic models by imposing strong constraints on individual and overall temperature B factors and thus the quality of crystal structures. Some researchers consider these data to be of little value and opt to discard them during data processing, particularly at medium and low resolution, at which individual B factors of atomic models cannot be refined. Here, new evidence is provided to show that the inclusion of these data helps to improve the quality of experimental phases by imposing proper constraints on electron-density models during noncrystallographic symmetry (NCS) averaging. Using electron-density correlation coefficients as criteria, the resolution of data has successfully been extended from 3.1 to 2.5 Å resolution with redundancy-independent merging R factors from below 100% to about 310%. It is further demonstrated that phase information can be fully extracted from observed amplitudes through de novo NCS averaging. Averaging starts with uniform density inside double-shelled spherical masks and NCS matrices that are derived from bound heavy-atom clusters at the vertices of cuboctahedrally symmetric protein particles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Updraft and Downdraft Core Size and Intensity as Revealed by Radar Wind Profilers: MCS Observations and Idealized Model Comparisons

This study explores the updraft and downdraft properties of mature stage mesoscale convective systems (MCSs) in terms of draft core width, shape, intensity, and mass flux characteristics. The observations use extended radar wind profiler (RWP) and surveillance radar datasets from the U.S. Department of Energy Atmospheric Radiation Measurement program for midlatitude (Oklahoma, USA) and tropical (Amazon, Brazil) sites. MCS drafts behave qualitatively similar to previous aircraft and RWP cloud summaries. The Oklahoma MCSs indicate larger and more intense convective up- and downdraft cores, and greater mass flux than Amazon MCS counterparts. However, similar size-intensity relationships and draft vertical profile behaviors are observed for both regions. Additional similarities include weak positive correlations between core intensity and core width (correlation coefficient r ~ 0.5), and increases in draft intensity with altitude. A model-observational intercomparison for draft properties (core width, intensity, mass flux) is also performed to illustrate the potential usefulness of statistical observed draft characterizations. Idealized simulations with the Weather Research and Forecasting model aligned with midlatitude MCS conditions are performed at model grid spacings (?x) that range from 4 km to 250 m. It is shown that the simulations performed at ?x = 250 m at similar mature MCS lifecycle stages are those that exhibit draft intensity, width, mass flux, and shape parameter performances best matching with observed properties.

radar, arm, wind profiler, goamazon↗