Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

(abstract) Cryogenic Telescope Test Facility

An optical test Dewar is being constructed with the unique capability to test mirrors of diameter less than or equal to 1 m, f less than or equal to 6, at temperatures from 300 to 4.2 K with a ZYGO Mark IV interferometer. The design and performance of this facility will be presented.

cryogenic Dewar optical test mirrors liquid helium↗

IABG CSiC Mirror

CSiC has been proposed as a material for large cryogenic mirrors because of its unique material properties. However, there is limited experience in the cryogenic optical performance of CSiC mirrors. Therefore, a CSiC mirror was fabricated for NASA MSFC by IABG, polished by General Optics and cryogenic tested by MSFC in its XRCF. This presentation will review the history of this mirror and summarize the results of its cryogenic testing.

Stahl, H. Philip↗

The E-3 Test Facility at Stennis Space Center: Research and Development Testing for Cryogenic and Storable Propellant Combustion Systems

This paper will provide the reader a broad overview of the current upgraded capabilities of NASA's John C. Stennis Space Center E-3 Test Facility to perform testing for rocket engine combustion systems and components using liquid and gaseous oxygen, gaseous and liquid methane, gaseous hydrogen, hydrocarbon based fuels, hydrogen peroxide, high pressure water and various inert fluids. Details of propellant system capabilities will be highlighted as well as their application to recent test programs and accomplishments. Data acquisition and control, test monitoring, systems engineering and test processes will be discussed as part of the total capability of E-3 to provide affordable alternatives for subscale to full scale testing for many different requirements in the propulsion community.

Pazos, John T.↗

Below Ambient and Cryogenic Thermal Testing

Methods and apparatus for the testing of below-ambient temperature thermal insulation systems have been developed based on boiloff calorimetry. Boiloff calorimetry provides a direct measure of heat flow for below-ambient temperature conditions. The effective thermal conductivity (ke) and heat flux (q) of a test specimen are calculated for a fixed environmental condition (warm boundary temperature; cold boundary temperature; ambient or vacuum pressure). Through its heat of vaporization, liquid nitrogen (LN2) serves as the energy meter. Different apparatus have been built for flat-plate, cylindrical, and pipeline test specimens. Boundary temperatures can range from 353 K down to 77 K (80 C to -196 C). By interposing different insulation layers on the cold boundary, the cryogenic boiloff method is suitable for a wide range of below-ambient temperature applications. A cylindrical apparatus, Cryostat-100, as well as the pipeline test apparatus, Cryostat-P100, are thermally guarded and directly measure absolute thermal performance in watts. Pipe insulation systems can be mechanical, double-walled, or vacuum-jacketed including materials such as foams, cellular glass, aerogel blankets, clam-shell panels, and multilayer insulation. Two test pipelines, 12-meter-long, are mounted between two cold box assemblies. The test pipeline diameter is from 25-mm to 76-mm while the maximum outside diameter including insulation is up to 204-mm. The cold pipe tester design and test methods are discussed, as well as results for select thermal insulation materials. Progress toward a comparative type, bench-top cold pipe tester (Cryostat-P200) is also discussed.

Fesmire, James E.↗

Stress Analysis and Permeability Testing of Cryogenic Composite Feed Line

For the next generation Single-Stage-To-Orbit (SSTO) Reusable Launch Vehicle (RLV), the use of advanced composite materials is highly desirable and critical to the success of the mission. NASA Marshall Space Flight Center (MSFC) has been working with the aerospace industry for many years to develop and demonstrate the cryogenic composite propellant tanks and feed lines technologies. A 50.8-mm diameter composite feed line for the Clipper Graham (DCY.A) was developed and tested. The purpose of the program is to demonstrate the LH2 permeability, composite to composite and metal joints, as well as composite flange interface of the composite feed line. Stress analysis and permeability testing have been performed on this article. Recently, a larger composite feed line design is being investigated and developed at MSFC for potential use in future RLV. The diameter of the feed line is 203 mm and the overall length is approximately 2.2 meters. This one piece unlined feed line consists of three straight tubular sections joined by two 90 degree elbows. The material chosen is IM7/977-3 prepreg fabric. The lay-up pattern is [0/90, plus or minus 45]s and is built up to 18 plies to the flanges at both ends. A preliminary stress analysis has been conducted to identify potential critical stresses and to develop the finite element analysis (FEA) capability of composite feed lines. As expected, the critical stresses occurred at the rims of some flange holes and the onset of the tapered tubular sections. Further analysis is required to determine the loads, flange deflection, vibration, and combined maximum loads. Two permeability-testing apparatuses were also designed for both flat panel specimens and curved feed line sections after impact damage. A larger permeant gas exposed area is required to accurately determine the effect of impact damage on the permeability of the feed line materials. The flat panel tester was fabricated and assembled. Three test coupons were made of graphite/epoxy plain weave prepreg and unidirectional prepreg. The flow rate was calculated by measuring the change of manometer fluid height per unit time. The permeability of the coupons is then calculated according to Darcy's Law. The pressure increase due to the head rise in the manometer was not considered for the initial estimation. The result of the unidirectional composite coupon agreed with that obtained from the DC-XA feed line testing of a similar material. Further improvement on the design may be required to improve the accuracy and efficiency of permeability testing.

Chu, Tsuchin Philip↗

COI Structural Analysis Presentation

This report discusses the structural analysis of the Next Generation Space Telescope Mirror System Demonstrator (NMSD) developed by Composite Optics Incorporated (COI) in support of the Next Generation Space Telescope (NGST) project. The mirror was submitted to Marshall Space Flight Center (MSFC) for cryogenic testing and evaluation. Once at MSFC, the mirror was lowered to approximately 40 K and the optical surface distortions were measured. Alongside this experiment, an analytical model was developed and used to compare to the test results. A NASTRAN finite element model was provided by COI and a thermal model was developed from it. Using the thermal model, steady state nodal temperatures were calculated based on the predicted environment of the large cryogenic test chamber at MSFC. This temperature distribution was applied in the structural analysis to solve for the deflections of the optical surface. Finally, these deflections were submitted for optical analysis and comparison to the interferometer test data.

Cline, Todd↗

Thermal Performance Testing of Cryogenic Insulation Systems

Efficient methods for characterizing thermal performance of materials under cryogenic and vacuum conditions have been developed. These methods provide thermal conductivity data on materials under actual-use conditions and are complementary to established methods. The actual-use environment of full temperature difference in combination with vacuum-pressure is essential for understanding insulation system performance. Test articles include solids, foams, powders, layered blankets, composite panels, and other materials. Test methodology and apparatus design for several insulation test cryostats are discussed. The measurement principle is liquid nitrogen boil-off calorimetry. Heat flux capability ranges from approximately 0.5 to 500 watts per square meter; corresponding apparent thermal conductivity values range from below 0.01 up to about 60 mW/m- K. Example data for different insulation materials are also presented. Upon further standardization work, these patented insulation test cryostats can be available to industry for a wide range of practical applications.

Fesmire, James E.↗

Validation of Heat Transfer Correlations in Line Chill-Down Tests of Cryogenic Fluid in SINDA/FLUINT

Line chill-down is an important process in cryogenic tank propellant management, storage, and usage Complex flow dynamics during these processes: boiling heat transfer (film, transition, and nucleate) Understanding boiling phenomena can lead to efficient line chill-down systems that use less propellant, propellant stored, reducing cost for space missions Line Chill-down heat transfer was modelled using SINDA/FLUINT version 5.8 (SF) Multiple chill-down tests were modelled using: heat transfer correlations readily available in SF using HTN/HTC TIES heat transfer empiricisms developed by the University of Florida (UF) based on a series of liquid nitrogen chill-down tests using SF HTU TIES Chill-down tests modelled: liquid nitrogen tests conducted by the University of Florida horizontal flow, upward flow, and downward flow (Reynolds Numbers ranging 850-231,000)liquid hydrogen tests conducted by NASA Glenn Research Center vertical upward flow (Reynolds Number range of 18,400 - 433,000)The flow rate was measured far downstream of the test section, near the system exit. Where to set the flow rate? SF was highly sensitive, and sometime unstable, setting the test flow rate downstream (the outlet) of the test section model and setting the test pressure upstream (the inlet) of the test section model higher flow rate oscillations at the entrance of the model's test section SF was more stable setting the test flow rate upstream (than the downstream flow rate set case)test pressure was used as an inlet (SF plenum) to set the thermodynamic state (temperature and quality) coming into the system setting the appropriate downstream pressure was the unknown. The pressure drops predicted by SF for the downstream set flow rate boundary condition were much smaller than test section measured pressure drops. The multiphase pressure drop correlations used internally in SF may need to be adjusted. Models with an upstream flow rate set assumed a pressure drop that was small

cryogenic modeling↗

Inverted Outflow Ground Testing of Cryogenic Propellant Liquid Acquisition Devices

NASA is currently developing propulsion system concepts for human exploration. These propulsion concepts will require the vapor free acquisition and delivery of the cryogenic propellants stored in the propulsion tanks during periods of microgravity to the exploration vehicles engines. Propellant management devices (PMDs), such as screen channel capillary liquid acquisition devices (LADs), vanes and sponges have been used for earth storable propellants in the Space Shuttle Orbiter and other spacecraft propulsion systems, but only very limited propellant management capability currently exists for cryogenic propellants. NASA is developing PMD technology as a part of their cryogenic fluid management (CFM) project. System concept studies have looked at the key factors that dictate the size and shape of PMD devices and established screen channel LADs as an important component of PMD design. Modeling validated by normal gravity experiments is examining the behavior of the flow in the LAD channel assemblies (as opposed to only prior testing of screen samples) at the flow rates representative of actual engine service (similar in size to current launch vehicle upper stage engines). Recently testing of rectangular LAD channels has included inverted outflow in liquid oxygen and liquid hydrogen. This paper will report the results of liquid oxygen testing compare and contrast them with the recently published hydrogen results; and identify the sensitivity these results to flow rate and tank internal pressure.

Liquid Oxygen↗

Inverted Outflow Ground Testing of Cryogenic Propellant Liquid Acquisition Devices

NASA is currently developing propulsion system concepts for human exploration. These propulsion concepts will require the vapor free acquisition and delivery of the cryogenic propellants stored in the propulsion tanks during periods of microgravity to the exploration vehicles engines. Propellant management devices (PMD's), such as screen channel capillary liquid acquisition devices (LAD's), vanes and sponges have been used for earth storable propellants in the Space Shuttle Orbiter and other spacecraft propulsion systems, but only very limited propellant management capability currently exists for cryogenic propellants. NASA is developing PMD technology as a part of their cryogenic fluid management (CFM) project. System concept studies have looked at the key factors that dictate the size and shape of PMD devices and established screen channel LADs as an important component of PMD design. Modeling validated by normal gravity experiments is examining the behavior of the flow in the LAD channel assemblies (as opposed to only prior testing of screen samples) at the flow rates representative of actual engine service (similar in size to current launch vehicle upper stage engines). Recently testing of rectangular LAD channels has included inverted outflow in liquid oxygen and liquid hydrogen. This paper will report the results of liquid oxygen testing compare and contrast them with the recently published hydrogen results; and identify the sensitivity of these results to flow rate and tank internal pressure.

Microgravity↗

NASA Prototype All Composite Tank Cryogenic Pressure Tests to Failure with Structural Health Monitoring

This Paper will describe the results of pressurization to failure of 100 gallon composite tanks using liquid nitrogen. Advanced methods of health monitoring will be compared as will the experimental data to a finite element model. The testing is wholly under NASA including unique PZT (Lead Zirconate Titanate) based active vibration technology. Other technologies include fiber optics strain based systems including NASA AFRC technology, Acoustic Emission, Acellent smart sensor, this work is expected to lead to a practical in-Sutu system for composite tanks.

tanks↗

Cryogenic 160-GHz MMIC Heterodyne Receiver Module

A cryogenic 160-GHz MMIC heterodyne receiver module has demonstrated a system noise temperature of 100 K or less at 166 GHz. This module builds upon work previously described in Development of a 150-GHz MMIC Module Prototype for Large-Scale CMB Radiation (NPO-47664), NASA Tech Briefs, Vol. 35, No. 8 (August 2011), p. 27. In the original module, the local oscillator signal was saturating the MMIC low-noise amplifiers (LNAs) with power. In order to suppress the local oscillator signal from reaching the MMIC LNAs, the W-band (75 110 GHz) signal had to be filtered out before reaching 140 170 GHz. A bandpass filter was developed to cover 120 170 GHz, using microstrip parallel-coupled lines to achieve the desired filter bandwidth, and ensure that the unwanted W-band local oscillator signal would be sufficiently suppressed. With the new bandpass filter, the entire receiver can work over the 140 180-GHz band, with a minimum system noise temperature of 460 K at 166 GHz. The module was tested cryogenically at 20 K ambient temperature, and it was found that the receiver had a noise temperature of 100 K over an 8-GHz bandwidth. The receiver module now includes a microstrip bandpass filter, which was designed to have a 3-dB bandwidth of approximately 120-170 GHz. The filter was fabricated on a 3-mil-thick alumina substrate. The filter design was based on a W-band filter design made at JPL and used in the QUIET (Q/U Imaging ExperimenT) radiometer modules. The W-band filter was scaled for a new center frequency of 150 GHz, and the microstrip segments were changed accordingly. Also, to decrease the bandwidth of the resulting scaled design, the center gaps between the microstrip lines were increased (by four micrometers in length) compared to the gaps near the edges. The use of the 150-GHz bandpass filter has enabled the receiver module to function well at room temperature. The system noise temperature was measured to be less than 600 K (at room temperature) from 154 to 168 GHz. Additionally, the use of a W-band isolator between the receiver module and the local oscillator source also improved the noise temperature substantially. This may be because the mixer was presented with a better impedance match with the use of the isolator. Cryogenic testing indicates a system noise temperature of 100 K or less at 166 GHz. Prior tests of the MMIC amplifiers alone have resulted in a system noise temperature of 65.70 K in the same frequency range (.160 GHz) when cooled to an ambient temperature of 20 K. While other detector systems may be slightly more sensitive (such as SIS mixers), they require more cooling (to 4 K ambient) and are not as easily scalable to build a large array, due to the need for large magnets and other equipment. When cooled to 20 K, this receiver module achieves approximately 100 K system noise temperature, which is slightly higher than single-amplifier module results obtained at JPL (65.70 K when an amplifier is corrected for back-end noise contributions). If this performance can be realized in practice, and a scalable array can be produced, the impact on cosmic microwave background experiments, astronomical and Earth spectroscopy, interferometry, and radio astronomy in general will be dramatic.

Samoska, Lorene A.↗

Mechanical testing of large cryogenic structures

The mechanical testing performed on the Cryogenic Limb Array Etalon Spectrometer (CLAES) instrument installed on the Upper Atmosphere Research Satellite is discussed. The CLAES determines temperatures and concentrations of stratospheric minor species as a function of altitude by measuring the atmospheric infrared emission spectra. CLAES is based on a telescope optical system and infrared spectrometer which are cooled with cryogens.

Newkirk, Roger↗

Ambient and cryogenic temperature testing of a 32-channel CMOS multiplexer

A 32 channel CMOS multiplexer was tested at room temperature and at liquid helium temperature (4.9 K). Voltage gain of the FET input stage, leakage current, electrical crosstalk, and noise as a function of clock frequency were measured. The voltage gain measured at 4.9 K was slightly higher than that measured at 300 K and was independent of clock frequency at both operating temperatures. The off channel leakage current was 0.23 pA/channel at 4.9 K. Electrical crosstalk between adjacent channels (one on, one off) was quite low. The spot noise at 10 Hz, of the CMOS multiplexer operating in the static mode did not vary significantly with operating temperature. In the dynamic mode (3.2 kHz clock) at room temperature, the spot noise at 10 Hz was substantially higher than that measured in the static mode.

Lee, J. H.↗

Cryogenic Optical Testing at the Marshall Space Flight Center

Optical test results of several lightweight mirrors using different instruments will be presented. Several optical figure-testing techniques were used to overcome the vibration problem associated with optical testing with long optical path length.

Eng, Ron↗