Search NASA⌕ Search

SEARCH · Search NASA

Results for “current limiters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Ion Transport and Crystal Rotation in Plastic Crystal Electrolytes Under Applied Electric Fields

Organic ionic plastic crystal electrolytes, containing a plastic crystal and lithium salt, offer a potential balance between mechanical and electrochemical properties for solid state lithium-ion battery electrolytes. These electrolytes contain multiple mobile ionic species (three or four), resulting in complex transport mechanisms which have not yet been established. Plastic crystals are defined by long-range positional order and short-range rotational disorder. It is therefore necessary to quantify changes in the local crystal structure of the electrolyte as current flows through it. Herein, we examine the electrochemical properties of pyrrolidinium-based plastic crystal electrolytes containing lithium salt and zwitterion additives, including measurements of current fraction and limiting current. We obtain species-specific insight into electrolyte transport using pulsed-field gradient nuclear magnetic resonance spectroscopy and find that, while the zwitterion additive increases ionic conductivity, it decreases lithium diffusivity with respect to other ionic components. With operando spatiotemporally resolved wide-angle X-ray scattering we observe location-specific crystal rotations due to the passage of ionic current. In conclusion, we posit that reducing energy dissipation due to rotation is essential for using plastic crystal electrolytes in practical applications.

Yap, Kyra M. K. [University of California, Berkele↗

Out of time order correlation of the Hubbard model with random local disorder

The out-of-time-order correlator (OTOC) serves as a powerful tool for investigating quantum information spreading and chaos in complex systems. We present a method employing non-equilibrium dynamical mean-field theory and coherent potential approximation combined with diagrammatic perturbation on the Schwinger–Keldysh contour to calculate the OTOC for correlated fermionic systems subjected to both random disorder and electron interaction. Furthermore, our key finding is that random disorder enhances the OTOC decay in the Hubbard model for the metallic phase in the weakly interacting limit. However, the current limitation of our perturbative solver restricts the applicability to weak interaction regimes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Production of Heavy α -Elements and 44 Ti in Cas A: Comparison to Abundances from 1D Core-collapse Supernova Models and Evidence for Carbon–Oxygen Shell Mergers

The merger between the carbon (C) and oxygen (O) shells hours to days before the collapse of a massive star significantly changes its nucleosynthesis, which is reflected in the elemental ratios observed in supernova remnants (SNRs). We present a nucleosynthesis study of 44 Ti production in core-collapse supernovae (CCSNe), highlighting large silicon (Si), sulfur (S), calcium (Ca), and, most importantly, argon (Ar) to neon (Ne) ratios as diagnostics for carbon–oxygen (C–O) shell mergers. We compare yields from eight different sets of CCSNe models to observations of Cassiopeia A (Cas A), and show that C–O shell mergers are consistently the models that best match X-ray and infrared observations. These models produce high Ar/Ne ratios (≳0.1), due to 20 Ne depletion and production of 36 Ar and 38 Ar, while lower ratios are obtained from nonmerger cases. Based on the Ar/Ne diagnostic, we compare the range of expected 44 Ti produced by C–O shell mergers, which is up to ∼20%–30% of the overall 44 Ti, but expected to be located outside the reverse shock. Based on the sets of models considered, the photon flux expected from the 44 Ti synthesized in the C–O shell merger in Cas A is below the NuSTAR and COSI detection limits, compatible with current limits locating most of the 44 Ti interior to the reverse shock, but might be detectable from proposed missions like ASCENT. Finally, for the SNR of 1987A, a dominant C–O merger origin of the observed 44 Ti is unlikely based on the observed redshift in its 44 Ti line.

79 ASTRONOMY AND ASTROPHYSICS↗

Self-healing fuse

Fast-acting current limiting device provides current overload protection for vulnerable circuit elements and then re-establishes conduction path within milliseconds. Fuse can also perform as fast-acting switch to clear transient circuit overloads. Fuse takes advantage of large increase in electrical resistivity that occurs when liquid metal vaporizes.

Jones, N. D.↗

Power electronic applications for Space Station Freedom

NASA plans to orbit a permanently manned space station in the late 1990s, which requires development and assembly of a photovoltaic (PV) power source system to supply up to 75 kW of electrical power average during the orbital period. The electrical power requirements are to be met by a combination of PV source, storage, and control elements for the sun and eclipse periods. The authors discuss the application of power electronics and controls to manage the generation, storage, and distribution of power to meet the station loads, as well as the computer models used for analysis and simulation of the PV power system. The requirements for power source integrated controls to adjust storage charge power during the insolation period current limiting, breaker interrupt current values, and the electrical fault protection approach are defined. Based on these requirements, operating concepts have been defined which then become drivers for specific system and element design.

Pickrell, Roy L.↗

Small-Signal Stability of Grid-Forming Converters Under Fault Conditions

Threshold virtual impedance (TVI)-based current limiting for grid-forming converters (GFMs) has gained great interest due to its ability to maintain voltage source behaviour during faults. However, sequence component extraction (SCE) and negative-sequence control (NSC) are often overlooked in small-signal stability assessments during faults. This paper develops small-signal sequence impedance models for GFMs under four well-known SCE methods based on TVI current limiting control during symmetrical fault conditions. Using the developed impedance models, the impacts of SCE and NSC, and the voltage and current control loop bandwidths, on system stability during faults are investigated. Additionally, since negative-sequence TVI (TVI-) is typically added along with its positive-sequence counterpart, which is often inductive, inductive and resistive TVI- are examined. The findings suggest that a higher voltage or current control loop bandwidth has a negative impact on system stability, while SCE and NSC largely reduce the stable range for voltage and current control loop bandwidth during faults, and that the severity of such impacts is determined by the particular SCE method. Furthermore, it is observed that inductive TVI- significantly degrades system stability, while resistive TVI- can enhance stability when suitable SCE methods are appropriately selected and designed. Matlab/Simulink electromagnetic transient simulations validate these analytical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, ate- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

14 SOLAR ENERGY↗

A Generic and Multi-Functional Electromagnetic Transient Model for Grid-Following Inverter: Preprint

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD TM software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, aB- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

grid following inverter↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

Power Actuation and Switching Module Test Results

The X2000 Power System Electronics (PSE) is a Jet Propulsion Laboratory (JPL) task to develop a new generation of power system building blocks for use on future deep-space missions. The effort includes the development of electronic components and modules that can be used as building blocks in the design of generic spacecraft power systems. All X2000 avionics components and modules are designed for use in centralized or distributed spacecraft architectures. The Power Actuation and Switching Module (PASM) has been developed under the X2000 program. This component enables a modular and scalable design approach for power switching applications, which can result in a wide variety of power switching architectures using this simple building block. The PASM is designed to provide most of the necessary power switching functions of spacecraft for various Deep Space missions including future missions to Mars, comets, Jupiter and its moons. It is fabricated using an ASIC process that is tolerant of high radiation. The development included two application specific integrated circuits (ASICs) and support circuitry all packaged using High Density Interconnect (HDI) technology. It can be operated in series or parallel with other PASMs. It can be used as a high-side or low-side switch and it can drive thruster valves, pyrotechnic devices such as NASA standard initiators, bus shunt resistors, and regular spacecraft component loads. Each PASM contains two independent switches with internal current limiting and over-current trip-off functions to protect the power subsystem from load faults. During turnon and turnoff each switch can limit the rate of current change (di/dt) to a value determined by the user. Three-way majority-voted On/Off commandability and full switch status telemetry (both analog and digital) are built into the module. This paper is a follow up to the one presented at he IECEC 2004 conference that will include the lessons learned and test results from the development.

X2000↗

Power Actuation and Switching Module Development

The Deep Space Avionics (DSA) Project is developing a Power Actuation and Switching Module (PASM). This component enables a modular and scalable design approach for power switching applications, which can result in a wide variety of power switching architectures using this simple building block. The PASM is designed to provide most of the necessary power switching functions of spacecraft for various Deep Space missions including future missions to Mars, comets, Jupiter and its moons. It is fabricated using an A SIC process that is tolerant of high radiation. The development includes two application specific integrated circuits (ASICs) and support circuitry all packaged using High Density Interconnect (HDI) technology. It can be operated in series or parallel with other PASMs, It can be used as a high-side or low-side switch and it can drive thruster valves, pyrotechnic devices such as NASA standard initiators, bus shunt resistors, and regular spacecraft component loads. Each PASM contains two independent switches with internal current limiting and over-current trip-off functions to protect the power subsystem from load faults. During turnon and turnoff each switch can limit the rate of current change (di/dt) to a value determined by the user. Threeway majority-voted On/Off commandability and full switch status telemetry (both analog and digital) are built into the module. This paper describes the development process used to design, model, fabricate, and test these compact and versatile power switches. Preliminary test results from prototype HDI PASM hardware are also discussed.

Power Actuation and Switching Module (PASM)↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters: Preprint

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

Cation Crossover Limits Accessible Current Densities for Zero-Gap Alkaline CO2 Reduction to Ethylene

Traditional CO2 reduction systems often fail in an alkaline environment due to the interaction of CO2 with a high-pH electrolyte, where carbonate and bicarbonate ion formation results in potassium-containing salt precipitation. The presence of the salt crystals causes a reduction in the selectivity of the electrolyzer toward CO2 conversion. Here, the critical operational variables, which elicit the salting out process, are investigated (i.e., ion transport). When the electrolyzer exceeds a critical current density, H2 evolution dominates CO2 reduction due to salt formation, which is confirmed by postmortem cross-sectional SEM-EDS of the electrode. The critical current density decreases with an increasing membrane thickness or anolyte ionic strength. Cathode salt formation is mediated by the unmitigated crossover of cations from the anolyte to the cathode across an anion exchange membrane, through which cations are imperfectly excluded. It is likely that electric field-driven migration promotes an increase in concentration of potassium across the membrane, until, at the critical current density for that electrolyzer arrangement, the concentration of potassium and bicarbonate ions exceeds the solubility limit of KHCO3, leading to salt precipitation.

CO2 reduction↗

Nuclear gamma rays from stellar flares

Solar flare observations are consistent with the phenomenological description that a loop of magnetic flux is convected to the surface of the star and twisted. The resulting inductive current parallel to the field is dissipated at an enhanced rate throughout the field volume by current limiting instabilities. The steady state balance between joule heating and thermal conduction along the field lines of force to the denser, cooler surface establishes a temperature distribution. The expansion of heated and ionized surface layers leads to a pressure balance and hence predictable density and X-ray emission measure. The current limitation instabilities result observationally in the parallel current being transferred to run-away ions that reach a kinetic energy of some finite fraction of the inductive potential drop. The nuclear excitation gamma rays produced by such a run-away ion current are calculated for a white dwarf flare.

Colgate, S. A.↗

Advanced Electric Distribution, Switching, and Conversion Technology for Power Control

The Electrical Power Control Unit currently under development by Sundstrand Aerospace for use on the Fluids Combustion Facility of the International Space Station is the precursor of modular power distribution and conversion concepts for future spacecraft and aircraft applications. This unit combines modular current-limiting flexible remote power controllers and paralleled power converters into one package. Each unit includes three 1-kW, current-limiting power converter modules designed for a variable-ratio load sharing capability. The flexible remote power controllers can be used in parallel to match load requirements and can be programmed for an initial ON or OFF state on powerup. The unit contains an integral cold plate. The modularity and hybridization of the Electrical Power Control Unit sets the course for future spacecraft electrical power systems, both large and small. In such systems, the basic hybridized converter and flexible remote power controller building blocks could be configured to match power distribution and conversion capabilities to load requirements. In addition, the flexible remote power controllers could be configured in assemblies to feed multiple individual loads and could be used in parallel to meet the specific current requirements of each of those loads. Ultimately, the Electrical Power Control Unit design concept could evolve to a common switch module hybrid, or family of hybrids, for both converter and switchgear applications. By assembling hybrids of a common current rating and voltage class in parallel, researchers could readily adapt these units for multiple applications. The Electrical Power Control Unit concept has the potential to be scaled to larger and smaller ratings for both small and large spacecraft and for aircraft where high-power density, remote power controllers or power converters are required and a common replacement part is desired for multiples of a base current rating.

Soltis, James V.↗

Dynamic array processing for computationally intensive expert systems in CLIPS

This paper puts forth an architecture for implementing a loop for advanced data structure of arrays in CLIPS. An attempt is made to use multi-field variables in such an architecture to process a set of data during the decision making cycle. Also, current limitations on the expert system shells are discussed in brief in this paper. The resulting architecture is designed to circumvent the current limitations set by the expert system shell and also by the operating environment. Such advanced data structures are needed for tightly coupling symbolic and numeric computation modules.

Athavale, N. N.↗

Arc discharge supply component protection circuitry

In a mercury-bombardment ion engine, the discharge supply is a high-current low-voltage one that maintains an arc or discharge inside the engine. In a 30-cm engine the supply provides up to 45 volts at about 13 amperes and is referenced at approximately 1100 volts above ground. Due to the engine discharge characteristics, a very slow feedback control loop is required. A high-speed current limit must be used to protect the components in the power conditioner, a pulse-width-modulated bridge inverter. A high-speed cycle-by-cycle current-limit circuit which allows the inverter to continue running in an overcurrent condition is used to protect it. The high-speed current sensing allows the inverter to be turned off each half cycle before the current in the primary of the inverter exceeds a safe level. This permits the inverter to continue to provide current into a discharge or a fault condition, until the feedback control system can actively control the current.

Ahrens, A. F.↗

Random Vibration Testing of Advanced Wet Tantalum Capacitors

Advanced wet tantalum capacitors allow for improved performance of power supply systems along with substantial reduction of size and weight of the systems that is especially beneficial for space electronics. Due to launch-related stresses, acceptance testing of all space systems includes random vibration test (RVT). However, many types of advanced wet tantalum capacitors cannot pass consistently RVT at conditions specified in MIL-PRF-39006, which impedes their use in space projects. This requires a closer look at the existing requirements, modes and mechanisms of failures, specifics of test conditions, and acceptance criteria. In this work, different lots of advanced wet tantalum capacitors from four manufacturers have been tested at step stress random vibration conditions while their currents were monitored before, during, and after the testing. It has been shown that the robustness of the parts and their reliability are mostly due to effective self-healing processes and limited current spiking or minor scintillations caused by RVT do not increase the risk of failures during operation. A simple model for scintillations events has been used to simulate current spiking during RVT and optimize test conditions. The significance of scintillations and possible effects of gas generation have been discussed and test acceptance criteria for limited current spiking have been suggested.

cracking↗