Search NASA⌕ Search

SEARCH · Search NASA

Results for “cyber security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Cybersecurity at the Grid Edge: Protecting LA's Energy Systems in a Connected World

Join SoCalGas and the National Laboratory of the Rockies (NLR) for an insightful webinar on securing operational technology and energy systems. Los Angeles has the second-largest metro by population in the nation, making it vital to protect the energy infrastructure that powers day-to-day life. However, cybersecurity for energy systems is an immense challenge due to an increasing number of interconnected devices and stakeholders. While there was traditionally a limited need to secure energy infrastructure, the grid is only becoming smarter and more software-defined. Amid aging infrastructure and evolving cyber threats, the need to ensure the security of energy is at an all-time high. Together, SoCalGas and NLR are assessing the current state-of-the-art of the energy ecosystem to understand gaps in current best practices and technologies relevant to powering the city of Los Angeles.

97 MATHEMATICS AND COMPUTING↗

A Survey of Cyber Threat

Multiple companies are competing to develop human-crewed and unmanned aerial vehicles to provide flight in urban environments. With the growth of aerial systems and future airborne vehicle networks and the need to enable secure data exchange and service interactions within Urban Air Mobility (UAM) environments, cybersecurity has come to the forefront as a topic, highlighting the need to protect these networks from cyber-attacks. This paper will identify potential threats, vulnerabilities, and weaknesses of UAM environments, that could lead to system compromises and disruptions.

Cyber Security↗

Digital-Threat Bias and Psychological Distance: Barriers to Foundational Digital-Security Improvement

Modern life is held together by a web of digital dependencies that enable and provide delivery of critical services and functions—think the provision of utilities such as electricity and water, as well as our dependency on digital services for social and economic services (internet, communication, etc.). As this dependency grows, the complexity related to the delivery of these critical services increases as well. As complexity increases, the understanding of the risk and impact associated with potential disruption, degradation, or destruction—due to either malicious or non-malicious events of those digitally enabled functions—decreases. One potential explanation for the difficulty to 1) understand the risks faced and 2) address them appropriately and effectively is the abstractness and psychological distance assigned to “digital threat.” The complexity of these digitally enabled services creates a perceived complicatedness; as a result, digital threats are treated differently than similarly devasting (but more easily understood) kinetic or physical threats. How we categorize these threats also matters. Acts of cyber-enabled sabotage to critical infrastructure need to be defined as irregular warfare. By inadequately defining the threat, we compound the problem. Acknowledging this digital-threat bias is foundational to improving the ability to protect critical infrastructure. Using construal-level theory and psychological-distance concepts provides an intriguing starting point to address these issues, to reframe the challenges faced, and pursue more effective critical infrastructure security and defense policy.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Advanced Research on Integrated Energy Systems (ARIES) Cyber Range Overview and Threat-to-Consequence Demonstration

This presentation was presented at the Aggregation and Grid Security Workshop - held on June 17-18, 2025, at NREL in Golden, Colorado. The goal of the two-day workshop was to address the critical cybersecurity challenges for the future electric grid. The threat-to-consequence demonstration showcases NREL's capability to model, simulate, test, and evaluate cyberattacks targeting energy systems that coincide with natural hazards, as well as the ramifications for the energy grid as a whole.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CIE Analysis Process for Engineered Systems

"CIE Analysis Process for Engineered Systems" outlines a comprehensive methodology for integrating Cyber-Informed Engineering (CIE) principles into both new and existing engineered systems. Sponsored by the U.S. Department of Energy’s Office of Cybersecurity, Energy Security, and Emergency Response (DOE CESER), the process aims to achieve cyber-informed decisions by producing functional security requirements for new systems and retrofitting existing systems to mitigate digital risks. The document details a step-by-step approach, including mission and function definition, digital asset awareness, consequence analysis, and mitigation analysis. It emphasizes the importance of documenting mechanical, electrical, programmable, and network components to protect system functions and provides examples and considerations for each step. The ultimate goal is to ensure that engineered systems remain resilient against cyber threats, maintaining safety, performance, and reliability.

42 - ENGINEERING↗

Data Centers and Digital Assurance Workshop 3 – Mitigations for Digital Assurance Risks

The third session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 18, 2025, focused on developing mitigation strategies for digital assurance risks identified in previous workshops. Hosted by Idaho National Laboratory (INL) and ScottMadden, the session emphasized the application of Cyber-Informed Engineering (CIE) to data center infrastructure, particularly at the utility–data center interface. Participants revisited and ranked key digital assurance risks, including architecture and interface weaknesses, governance gaps, and AI-enabled threats. The workshop introduced the 12 principles of CIE, advocating for consequence-focused design, engineered controls, and secure information architecture to proactively reduce cyber-physical vulnerabilities. These principles were applied to critical data center systems such as power distribution, UPS, cooling, SCADA/BMS, and grid-forming batteries. The session also addressed governance challenges at the interconnection boundary, highlighting the need for clear roles in telemetry sharing, firmware management, and trip settings. Special attention was given to emerging risks from behind-the-meter (BTM) generation, including reverse-power flow and the integration of small modular reactors (SMRs), which shift data centers from large loads to complex generation nodes. Participants explored how interconnection agreements can serve as enforceable instruments for digital assurance, and reviewed gaps in current standards such as NERC CIP, IEC 62443, and IEEE 1547. The workshop concluded with pathways to standardization, including model agreement language, state-level programs, and expanded NERC guidance. INL also presented tools and frameworks for secure procurement and supplier risk management, reinforcing the need for integrated engineering and policy solutions to secure the evolving data center–grid ecosystem. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Informed Engineering (CIE) Principles Slide Presentation [Slides]

This document describes the concept and application of Cyber-Informed Engineering (CIE), a methodology that integrates cyber threat awareness into all stages of the systems engineering life cycle. It delineates how CIE enhances the security posture of critical infrastructure systems, which are increasingly targeted by sophisticated cyber threats. The exposition proceeds to methodically walk through the twelve foundational principles of CIE, each serving as a strategic guidepost for embedding cybersecurity into the fabric of system design, development, operation, and maintenance. The principles highlight the importance of proactive and comprehensive security measures that span from risk assessment to continuous improvement, ensuring that systems are not only designed with security in mind but are also resilient in the face of evolving cyber threats.

42 ENGINEERING↗

Supporting U.S. National Security Through Cybersecurity Partnerships

At NLR, we're studying energy evolutions and threats to understand the challenges they pose and uncover ways to leverage grid advancements to achieve more secure, defensible, and reliable systems. Our integrated research approach bridges the gap between cyber threats and real-world consequences to deliver actionable solutions that reduce vulnerabilities and help strengthen U.S. national security.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Design and Evaluation of Zero Trust Architecture for Electric Vehicle Charging Infrastructure: EVs @ Scale Series on EV Charging Station Cybersecurity

Implementing a zero trust architecture can significantly bolster the security of electric vehicle (EV) charging infrastructure. EV charging infrastructure includes numerous networked interfaces, each of which can present potential vulnerabilities. When these vulnerabilities are exploited, they can compromise the entire system, leading to severe operational and security risks. Zero trust is a security model that operates on the principle of "never trust, always verify," which helps manage the attack surface and limit the scope of any potential compromises. Fundamentally, this model ensures that no entity, whether inside or outside the network, is trusted by default. The design principles of zero trust include continuous verification, strict deny-by-default access controls, and micro-segmentation. Continuous verification ensures that every request is thoroughly checked, regardless of its origin. Strict access controls enforce the principle of least privilege, allowing users and devices only the minimum necessary access to perform their functions. Micro-segmentation involves dividing the network into smaller, isolated segments to prevent lateral movement in case of a breach. In the context of EV charging infrastructure, zero trust can be implemented through various strategies. For example, multi-factor authentication (MFA) can be required for engineers to access the management interfaces and control systems of charging stations. Real-time monitoring and analysis of network traffic can help detect and respond to anomalies. Systems that do not need to communicate with each other can be micro-segmented to enhance security. All communications should adhere to predefined policies to be permitted. Additionally, encrypting communications can protect sensitive information exchanged between chargers and management systems. This paper presents a zero trust architecture specifically designed for EV charging infrastructure. Implementing zero trust not only mitigates risks but also builds a resilient infrastructure capable of withstanding and quickly recovering from cyber threats. The architecture addresses six defined security objectives. A comprehensive test plan is developed to assess the architecture against these objectives, and the results of the evaluation are reported. This approach is essential for maintaining the reliability and integrity of EV charging services in an increasingly interconnected and vulnerable digital landscape. This is the first in a planned series of papers exploring the implementation of zero trust in EV charging infrastructure. Each paper will delve into different aspects and applications of zero trust, highlighting how various work processes and requirements can lead to distinct architectural designs. These architectures will be tailored to address specific security challenges and operational needs within the EV charging ecosystem, ensuring a robust and adaptable security framework.

33 ADVANCED PROPULSION SYSTEMS↗

CIEPAT for Photovoltaic System Resilience

The Cyber-Informed Engineering Photovoltaic Analysis Tool (CIEPAT) was developed in collaboration with the U.S. Department of Energy's Office of Cybersecurity, Energy Security, and Emergency Response (CESER). This tool is an energy source subcomponent integrated into the CIEMAT ecosystem and is developed to enhance the security and resilience of Photovoltaic installations by incorporating Cyber-Informed Engineering (CIE) principles into the deployment of PV systems.

14 SOLAR ENERGY↗

Partially Observable Games for Secure Autonomy

Technology development efforts in autonomy and cyber-defense have been evolving independently of each other, over the past decade. In this paper, we report our ongoing effort to integrate these two presently distinct areas into a single framework. To this end, we propose the two-player partially observable stochastic game formalism to capture both high-level autonomous mission planning under uncertainty and adversarial decision making subject to imperfect information. We show that synthesizing sub-optimal strategies for such games is possible under finite-memory assumptions for both the autonomous decision maker and the cyber-adversary. We then describe an experimental testbed to evaluate the efficacy of the proposed framework.

Ames, Aaron D.↗

CIEPAT (Cyber-Informed Engineering Photovoltaic Analysis Tool) [SWR-25-171]

The Cyber-Informed Engineering Photovoltaic Analysis Tool (CIEPAT) was developed in collaboration with the U.S. Department of Energy’s Office of Cybersecurity, Energy Security, and Emergency Response (CESER). This tool is a energy source subcomponent integrated into the CIEMAT ecosystem and is developed to enhance the security and resilience of Photovoltaic installations by incorporating Cyber-Informed Engineering (CIE) principles into the deployment of PV systems.

Etigowni, Sriharsha [National Laboratory of the Ro↗

Digital Assurance Checklist for Homeowners and Installers

This document provides a comprehensive Digital Assurance Checklist for securing behind-the-meter energy assets, focusing on both installers and homeowners. As distributed energy resources (DERs) such as solar PV and battery storage become integral to residential energy systems, cybersecurity emerges as a critical component of reliability and safety. The guide outlines actionable steps for installers during pre-installation, commissioning, and post-installation phases, emphasizing practices like network segmentation, credential management, firmware validation, and homeowner education. For homeowners, the document introduces a tiered approach to cyber hygiene—from essential measures like strong Wi-Fi credentials and automatic updates to advanced strategies such as network segmentation, DNS filtering, and intrusion detection. By adopting these practices, stakeholders can mitigate cyber risks, safeguard energy infrastructure, and ensure resilient, secure operation of DER systems. Additional resources and references to industry standards are included to support implementation.

99 - GENERAL AND MISCELLANEOUS↗

Digital Assurance Checklist for Homeowners and Installers

This document provides a comprehensive Digital Assurance Checklist for securing behind-the-meter energy assets, focusing on both installers and homeowners. As distributed energy resources (DERs) such as solar PV and battery storage become integral to residential energy systems, cybersecurity emerges as a critical component of reliability and safety. The guide outlines actionable steps for installers during pre-installation, commissioning, and post-installation phases, emphasizing practices like network segmentation, credential management, firmware validation, and homeowner education. For homeowners, the document introduces a tiered approach to cyber hygiene—from essential measures like strong Wi-Fi credentials and automatic updates to advanced strategies such as network segmentation, DNS filtering, and intrusion detection. By adopting these practices, stakeholders can mitigate cyber risks, safeguard energy infrastructure, and ensure resilient, secure operation of DER systems. Additional resources and references to industry standards are included to support implementation.

99 - GENERAL AND MISCELLANEOUS↗

CIECAT (Cyber-Informed Engineering Commercial Buildings Analysis Tool) [SWR-25-172]

The Cyber-Informed Engineering Commercial Buildings Analysis Tool (CIECAT) was developed in collaboration with the U.S. Department of Energy’s Office of Cybersecurity, Energy Security, and Emergency Response (CESER). This tool is a energy source subcomponent integrated into the CIEMAT ecosystem and is developed to enhance the security and resilience of Commercial Buildings by incorporating Cyber-Informed Engineering (CIE) principles into the Commercial Buildings.

Etigowni, Sriharsha [National Laboratory of the Ro↗

Total Power Factor Smart Contract with Cyber Grid Guard Using Distributed Ledger Technology for Electrical Utility Grid with Customer-Owned Wind Farm

In modern electrical grids, the numbers of customer-owned distributed energy resources (DERs) have increased, and consequently, so have the numbers of points of common coupling (PCC) between the electrical grid and customer-owned DERs. The disruptive operation of and out-of-tolerance outputs from DERs, especially owned DERs, present a risk to power system operations. A common protective measure is to use relays located at the PCC to isolate poorly behaving or out-of-tolerance DERs from the grid. Ensuring the integrity of the data from these relays at the PCC is vital, and blockchain technology could enhance the security of modern electrical grids by providing an accurate means to translate operational constraints into actions/commands for relays. This study demonstrates an advanced power system application solution using distributed ledger technology (DLT) with smart contracts to manage the relay operation at the PCC. The smart contract defines the allowable total power factor (TPF) of the DER output, and the terms of the smart contract are implemented using DLT with a Cyber Grid Guard (CGG) system for a customer-owned DER (wind farm). This article presents flowcharts for the TPF smart contract implemented by the CGG using DLT. The test scenarios were implemented using a real-time simulator containing a CGG system and relay in-the-loop. The data collected from the CGG system were used to execute the TPF smart contract. The desired TPF limits on the grid-side were between +0.9 and +1.0, and the operation of the breakers in the electrical grid and DER sides was controlled by the relay consistent with the provisions of the smart contract. The events from the real-time simulator, CGG, and relay showed a successful implementation of the TPF smart contract with CGG using DLT, proving the efficacy of this approach in general for implementing electrical grid applications for utilities with connections to customer-owned DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Security Assessment of an LBP16-Protocol-Based Computer Numerical Control Machine

Subtractive manufacturing systems, specifically, computer numerical control machines, have revolutionized the manufacturing industry. Computer numerical control machining is the preferred method for producing finished parts due to its efficiency, speed and suitability for high-volume production. Securing computer numerical control machines is a priority. Compromises or disruptions of these machines can result in significant downtime, loss of productivity and financial loss. This study examines the vulnerabilities and risks associated with computer numerical control machines, in particular, systems utilizing the LBP16 protocol for controller-machine communications. The study reveals that an adversary can execute cyber-physical attacks such as sabotage and denial of service. The potential security threats emphasize the importance of implementing robust security measures to mitigate the cyber risks to computer numerical control machines.

Forihat, Yahya [Virginia Commonwealth University, ↗

Addressing Consequence within Operational Risk (O.T. Gagnon III) 9-18-2024

Addressing Consequence within Operational Risk: Why threats and security are just not that important! When dealing with cyber or physical risk within any critical infrastructure (CI) environment, don’t concern yourself with vulnerabilities and threats, at least not at first! Also, don’t be overly fixated on “securing the systems” within the organization. The endeavor of tackling operational risk focused on consequences in any critical infrastructure environment to include the complex Aviation ecosystem is challenging even for the most resourced entity but can be advanced though a simplified approach: identifying, binning, and prioritizing the infrastructure environment. While no two entities within a single element of the 16 critical infrastructure sectors are exactly alike when it comes to risk, there is a basic process to move toward a greater understanding of operational risk through becoming more informed about the infrastructure environment in which the entity exists. The process starts with bringing internal and external stakeholders and subject matter experts together to analyze key areas such as Information Technology (IT) and Operational Technology (OT) components and points of convergence, analyzing internal and external cyber and physical dependencies, accounting for explosive growth in devices and wireless technology, and leveraging the contributions of people inside and outside the operational environment. Attaining a common understanding of the infrastructure environment as part of addressing consequences within operational risk is not easy to do or resource light, but the process outlined provides the framework to further any entity’s efforts in this space. When it comes to cyber risks, before an organization can consider vulnerabilities within and threats to its operations, it must first have a solid understanding of the consequences existing inside its infrastructure environment. Idaho National Lab’s Consequence-Driven, Cyber-Informed Engineering is offered as an example of this approach to effective and efficient cyber risk mitigation.

99 GENERAL AND MISCELLANEOUS↗