Search NASA⌕ Search

SEARCH · Search NASA

Results for “data card”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Report on ISR-1 High-Altitude Balloon Flight

To test small technologies at lower cost for space science applications, LANL has developed a small high altitude balloon payload that could, in the future, be regularly and inexpensively launched from LANL. A neutron detector, NEMO, was integrated to evaluate its performance in a space-like mixed-radiation environment and collect neutron data in the atmosphere. In collaboration with EES-14, a high-altitude balloon payload was launched from LANL Technical Area 51 on February 27, 2023 and April 17, 2023. For real-time geolocation, a SAM-M8Q M8 GNSS module was used to get position and time, and an Iridium RockBLOCK 9603 was used to communicate with the ground using the Iridium satellite fleet. These modules were all controlled using an Iteaduino Mega microcontroller board. Finally, a High Altitude Science Eagle Flight Computer with a temperature pressure sensor ran independently, writing data to an SD card. All of these modules were powered by a 5 mAh lithium polymer battery. The battery was attached to the bottom of the payload while the remaining electronics were embedded in the underside of the top of the payload. These modules were wired as seen in Figure 1-2. The Iteaduino Mega microcontroller board was programmed to use the RockBLOCK to send a message once every 10 minutes containing neutron and GPS data read off the NEMO and SAM M8Q, respectively. Once the message send attempt finished, the RockBLOCK would be slept for the rest of the 10 minute interval. The Eagle Flight Computer ran continuously throughout the flight, taking data every 6 seconds. The RockBLOCK message data was set up to be delivered from the Iridium satellite fleet to a website, where it was stored and parsed to create live maps and plots for analysis and balloon retrieval. The RockBLOCK message data was additionally configured to be sent to an email as a fail-safe. The payload was ground-tested successfully for over 50 hours, with multiple revisions occurring to best prepare for conditions at altitude and improve the software and firmware to fix any issues that cropped up with the data pipeline. Additional to the balloon payload, the flight had an attached iMet-4 radiosonde and Garmin T5 GPS Dog Collar. The radiosonde provided GPS and meteorological data. The T5 dog collar is used along with a Garmin Astro 430 to track the balloon at a range of up to 9 miles for retrieval. The balloon itself was initially a 1600 g meteorological balloon with an attached High Altitude Science parachute, both of which can be seen in Figure 1-3. After the first flight, the EES team swapped to a Rocketman parachute.

42 ENGINEERING↗

Using NVMe Gen3 PCIe SSD Cards in High-density Servers for High-performance Big Data Transfer Over Multiple Network Channels

This Technical Note describes how the Zettar team came up with a data transfer cluster design that convincingly proved the feasibility of using high-density servers for high-performance Big Data transfers. It then outlines the tests, operations, and observations that address a potential over-heating concern regarding the use of Non-Volatile Memory Host Controller Interface Specification (NVMHCI aka NVM Express or NVMe) Gen 3 PCIe SSD cards in high-density servers. Finally, it points out the possibility of developing a new generation of high-performance Science DMZ data transfer system for the data-intensive research community and commercial enterprises.

97 MATHEMATICS AND COMPUTING↗

The Metropolis Monte Carlo method with CUDA enabled Graphic Processing Units

We present a CPU–GPU system for runtime acceleration of large molecular simulations using GPU computation and memory swaps. The memory architecture of the GPU can be used both as container for simulation data stored on the graphics card and as floating-point code target, providing an effective means for the manipulation of atomistic or molecular data on the GPU. To fully take advantage of this mechanism, efficient GPU realizations of algorithms used to perform atomistic and molecular simulations are essential. Our system implements a versatile molecular engine, including inter-molecule interactions and orientational variables for performing the Metropolis Monte Carlo (MMC) algorithm, which is one type of Markov chain Monte Carlo. By combining memory objects with floating-point code fragments we have implemented an MMC parallel engine that entirely avoids the communication time of molecular data at runtime. Our runtime acceleration system is a forerunner of a new class of CPU–GPU algorithms exploiting memory concepts combined with threading for avoiding bus bandwidth and communication. The testbed molecular system used here is a condensed phase system of oligopyrrole chains. A benchmark shows a size scaling speedup of 60 for systems with 210,000 pyrrole monomers. Our implementation can easily be combined with MPI to connect in parallel several CPU–GPU duets. -- Highlights: •We parallelize the Metropolis Monte Carlo (MMC) algorithm on one CPU—GPU duet. •The Adaptive Tempering Monte Carlo employs MMC and profits from this CPU—GPU implementation. •Our benchmark shows a size scaling-up speedup of 62 for systems with 225,000 particles. •The testbed involves a polymeric system of oligopyrroles in the condensed phase. •The CPU—GPU parallelization includes dipole—dipole and Mie—Jones classic potentials.

97 MATHEMATICS AND COMPUTING↗

Computational Offload with BlueField Smart NICs

The recent introduction of a new generation of "smart NICs" have provided new accelerator platforms that include CPU cores or reconfigurable fabric in addition to traditional networking hardware and packet offloading capabilities. While there are currently several proposals for using these smartNICs for low-latency, in-line packet processing operations, there remains a gap in knowledge as to how they might be used as computational accelerators for traditional high-performance applications. This work aims to look at benchmarks and mini-applications to evaluate possible benefits of using a smartNIC as a compute accelerator for HPC applications. We investigate NVIDIA's current-generation BlueField-2 card, which includes eight Arm CPUs along with a small amount of storage, and we test the networking and data movement performance of these cards compared to a standard Intel server host. We then detail how two different applications, YASK and miniMD can be modified to make more efficient use of the BlueField-2 device with a focus on overlapping computation and communication for operations like neighbor building and halo exchanges. Our results show that while the overall compute performance of these devices is limited, using them with a modified miniMD algorithm allows for potential speedups of 5 to 20% over the host CPU baseline with no loss in simulation accuracy.

97 MATHEMATICS AND COMPUTING↗

Multichannel low power time-to-digital converter card with 21 ps precision and full scale range up to 10 μs

We present a Time-to-Digital Converter (TDC) card with a compact form factor, suitable for multichannel timing instruments or for integration into more complex systems. The TDC Card provides 10 ps timing resolution over the whole measurement range, which is selectable from 160 ns up to 10 μs, reaching 21 ps rms precision, 1.25% LSB rms differential nonlinearity, up to 3 Mconversion/s with 400 mW power consumption. The I/O edge card connector provides timing data readout through either a parallel bus or a 100 MHz serial interface and further measurement information like input signal rate and valid conversion rate (typically useful for time-correlated single-photon counting application) through an independent serial link.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unattended Dual Current Monitor (UDCM) FY17 Summary Report

The UDCM is a low current measurement device designed to record pico-amp to micro-amp currents from radiation detectors. The UDCM is the planned replacement for the IAEA’s obsolete MiniGRAND data acquisition module. Preliminary testing of the UDCM at the IAEA facilities lead to the following recommendations from the IAEA: Increase the measurement range. Lower range by a factor of 5 and upper range by 2 orders of magnitude; Modifications to the web interface; Increase programmable acquisition time to 3600s; Develop a method to handle current offsets and negative current; Error checking when writing data to the uSD card; and Writing BID files along with the currently stored BI0 files.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A VXS [VITA41] Trigger Processor for the 12GEV Experimental Programs at Jefferson Lab

The VXS_Trigger_Processor [VTP] was developed and commissioned for CLAS12 in the fall of 2016. This board is a VITA41 switch card and it collects data from a variety of front-end TDC and Flash ADC modules. The VTP has since been used in several experiments at Jefferson Lab serving as the L1 trigger module for a variety of detector types, such as stacked calorimeters, strip calorimeters, time-of-flight, Cerenkov, hodoscopes, drift chambers, and silicon strips. Trigger algorithms implemented include cluster finding (1D, 2D), drift chamber segment and road finding, geometry matching between various detectors, particle counting, and general global trigger bit processing. The VTP is also capable of reading out each front-end crate with up to 40Gbps Ethernet which is an enormous increase compared to the currently used 200MB/s VME bus. Recent progress has been made to show that a firmware and software upgrade can enable existing Jefferson Lab front-end crates to operate in a streaming DAQ mode. In February 2020, tests will be performed on a full calorimeter and matched hodoscope which are components of the CLAS12 Forward Tagger detector system with beam in Hall B. This paper details the hardware performance, triggered, and streaming applications that have been implemented using the VTP for several experiments at Jefferson Lab.

ABBOTT, David↗

Mission Analysis Program for Solar Electric Propulsion (MAPSEP). Volume 2: User's manual for earth orbital MAPSEP

The trajectory simulation mode (SIMSEP) requires the namelist SIMSEP to follow TRAJ. The SIMSEP contains parameters which describe the scope of the simulation, expected dynamic errors, and cumulative statistics from previous SIMSEP runs. Following SIMSEP are a set of GUID namelists, one for each guidance correction maneuver. The GUID describes the strategy, knowledge or estimation uncertainties and cumulative statistics for that particular maneuver. The trajectory display mode (REFSEP) requires only the namelist TRAJ followed by scheduling cards, similar to those used in GODSEP. The fixed field schedule cards define: types of data displayed, span of interest, and frequency of printout. For those users who can vary the amount of blank common storage in their runs, a guideline to estimate the total MAPSEP core requirements is given. Blank common length is related directly to the dimension of the dynamic state (NDIM) used in transition matrix (STM) computation, and, the total augmented (knowledge) state (NAUG). The values of program and blank common must be added to compute the total decimal core for a CDC 6500. Other operating systems must scale these requirements appropriately.

Source record↗

Stability Statistics Data Base System

Stability Statistics Data Base System is written entirely in FORTRAN and does not require use of outside data-management routines. Is used with directly-accessible data base containing simple card images. Four FORTRAN modules implement edit, sort, report-generation, and other functions.

Kwok, G. Y.↗

Archival of aircraft scatterometer data from AAFE RADSCAT missions

Aircraft scatterometer data obtained over the ocean with the Radiometer-Scatterometer (RADSCAT) instrument is documented. The normalized radar cross section data was obtained at 13.9 GHz for a variety of ocean surface wind conditions, which are also presented. All such valid RADSCAT ocean scatterometer data for which surface truth was obtained are included, except for ice research missions during the last year of RADSCAT's lifetime. Aircraft scatterometer data obtained for the SEASAT underflights were with a second instrument, the Airborne Microwave Scatterometer (AMSCAT). The RADSCAT data are archived on card image computer tapes and on microfiche.

Schroeder, L. C.↗

STS-99 Countdown Status Briefing

After an introduction by Bruce Buckingham (NASA Public Affairs), participants Jeff Spaulding (NASA Test Director, Scott Higginbotham (STS-99 Payload Manager), and Ed Priselac (Shuttle Weather Officer) proceed with the countdown status briefing. They expressed that the opening countdown was proceeding well and servicing of the cryotanks was completed. The launch pad closeouts continued and the tanking process was in order. There was a card failure in the data handling processor, so a backup system was used.

Source record↗

622-Mbps Orthogonal Frequency Division Multiplexing Modulator Developed

The Communications Technology Division at the NASA Lewis Research Center is developing advanced electronic technologies for the space communications and remote sensing systems of tomorrow. As part of the continuing effort to advance the state-of-the art in satellite communications and remote sensing systems, Lewis is developing a programmable Orthogonal Frequency Division Multiplexing (OFDM) modulator card for high-data-rate communication links. The OFDM modulator is particularly suited to high data-rate downlinks to ground terminals or direct data downlinks from near-Earth science platforms. It can support data rates up to 622 megabits per second (Mbps) and high-order modulation schemes such as 16-ary quadrature amplitude modulation (16-ary QAM) or 8- phase shift keying (8PSK). High order modulations can obtain the bandwidth efficiency over the traditional binary phase shift keying (BPSK) or quadrature phase shift keying (QPSK) modulator schemes. The OFDM modulator architecture can also be precompensated for channel disturbances and alleviate amplitude degradations caused by nonlinear transponder characteristics.

Nguyen, Na T.↗

Enabling Experimental Evolution: Multi-Parameter Sensor System Integration into a Culture/Stressor Biofluidics System

Experimental evolution (EE) exposes microbial communities to ecological stressors, simulating dynamics up to near-extinction events. Combined with comparative sequencing and other molecular tools, such data can inform the genetic and other biological mechanisms underlying extremophile adaptation, and other observed effects. Automating this type of experiment using biofluidics can mitigate many traditional obstacles, including delays in assay results and environment adjustment and the need for many replicates. A first-generation device for automating EE procedures, the Automated Adaptive Directed Evolution Chamber (AADEC), was developed at NASA Ames. UV-C radiation was the stressor, an LED-photodiode array measured optical density, magnetic agitation and peristaltic pump systems ensured nutrient availability, and Arduino microcontrollers provided control. Escherichia coli in LB kanamycin media was used for testing and performance verification. A manual laboratory procedure with timed exposure to UV-C was performed to typify tolerance acquisition. Approximately a 106 factor increase in survival ratio was recorded over multiple iterations. Currently, a second-generation device is being developed integrating more real-time sensors: redox potential (ORP), indicating available/consumed metabolic energy; dissolved oxygen (DO), indicating aerobic/anaerobic growth; pH, indicating metabolic products; and electrical conductivity (EC), another indicator of metabolic products. The EC sensor system was constructed and calibrated in-house and matched commercial sensors in the required range. A Raspberry Pi computer automated the electrical system, allowing real-time data acquisition. The fluidics card was made of CNC-milled polycarbonate for biocompatibility. Each sensor parameter can also be used as a selection pressure alone or in combination with others to create extreme microbial environments. As a proof of concept, this work demonstrated sensor operation in one pair of growth-sensor chambers. It can be expanded to a multi-chamber system to enable inter-culture comparisons and multi-population studies. The prior Arduino system will be ported to the RPi system. Future stressors to be added include thermal, reactive oxygen species, and varying nutrient availability.

Govinda Raj, Chinmayee↗

VLSI high speed packet processor

The Goddard Space Flight Center Mission Operations and Data Systems Directorate has developed a packet processor card utilizing semicustom very large scale integration (VLSI) devices, microprocessors, and programmable gate arrays to support the implementation of multichannel telemetry data capture systems. This card will receive synchronized error corrected telemetry transfer frames and output annotated application packets derived from this data. An adaptable format capability is provided by the programmability of three microprocessors while the throughput capability of the packet processor is achieved by a data pipeline consisting of two separate RAM systems controlled by specially designed semicustom VLSI logic.

Grebowsky, Gerald J.↗

Portable Electromyograph

A portable electronic apparatus records electromyographic (EMG) signals in as many as 16 channels at a sampling rate of 1,024 Hz in each channel. The apparatus (see figure) includes 16 differential EMG electrodes (each electrode corresponding to one channel) with cables and attachment hardware, reference electrodes, an input/output-and-power-adapter unit, a 16-bit analog-to-digital converter, and a hand-held computer that contains a removable 256-MB flash memory card. When all 16 EMG electrodes are in use, full-bandwidth data can be recorded in each channel for as long as 8 hours. The apparatus is powered by a battery and is small enough that it can be carried in a waist pouch. The computer is equipped with a small screen that can be used to display the incoming signals on each channel. Amplitude and time adjustments of this display can be made easily by use of touch buttons on the screen. The user can also set up a data-acquisition schedule to conform to experimental protocols or to manage battery energy and memory efficiently. Once the EMG data have been recorded, the flash memory card is removed from the EMG apparatus and placed in a flash-memory- card-reading external drive unit connected to a personal computer (PC). The PC can then read the data recorded in the 16 channels. Preferably, before further analysis, the data should be stored in the hard drive of the PC. The data files are opened and viewed on the PC by use of special- purpose software. The software for operation of the apparatus resides in a random-access memory (RAM), with backup power supplied by a small internal lithium cell. A backup copy of this software resides on the flash memory card. In the event of loss of both main and backup battery power and consequent loss of this software, the backup copy can be used to restore the RAM copy after power has been restored. Accessories for this device are also available. These include goniometers, accelerometers, foot switches, and force gauges.

De Luca, Gianluca↗

Growth Curve Parameterization of Metabolic Activity of Yeast Cells for BioSentinel

The goal of the BioSentinel small satellite payload is to measure the effect of deep space radiation on the growth and metabolic activity of yeast cells. Raw test data is generated by fluidics cards containing yeast cells rehydrated at different periods, with metabolic activity measured by the reduction of alamarBlue. Each card well has a sensor array that measures the amount of red, green, and infrared light transmitted through the yeast culture. This illumination data is then converted to absorbance values, which are further converted into concentrations. The ultimate objective is to convert these concentrations into biologically-relevant metrics that can be compared against one another to determine changes due to differential radiation exposure. Beginning with IR absorbance data (corresponding to cell density) from ground studies, three parameters from a sigmoidal growth curve were extracted and analyzed: 𝜆 (lag phase), 𝜇 (max growth rate), and A (max cell growth). The data was fit to the Gompertz model of microbial growth using non-linear regression (Minitab), as the fit error was reduced compared to the simpler logistic growth curve. Graphs showed that the data contained a discrepancy (drift) in the lag phase that is attributable to a slow, constant loss of moisture. Correcting this discrepancy by fitting the first 25 hours of the data to a power function and subtracting these values from the absorbance readings obtained a better statistical fit to the growth curve in the lag phase. A power fit was selected over a linear fit because it reflected the effects of constant volume loss. This correction to the BioSentinel data analysis pipeline will enable quantitative statistical analysis of the effect of different levels of deep space radiation on yeast cells. Future work includes automation of drift correction and curve modeling to extract these parameters directly from data.

Growth Curve↗

Wireless Self-Acquistion of 12-Lead ECG via Android Smart Phone

Researchers at NASA s Johnson Space Center and at Orbital Research, Inc. (a NASA SBIR grant recipient) have recently developed a dry-electrode harness that allows for self-acquisition of resting 12-lead ECGs by minimally trained laypersons. When used in conjunction with commercial wireless (e.g., Bluetooth(TM) or 802.11-enabled) 12-lead ECG devices and custom smart phone-based software, the collected 12-lead ECG data can also immediately be forwarded from any geographic location within cellular range to the user s physician(s) of choice. The system can also be used to immediately forward to central receiving stations 12-lead ECG data collected during space flight or during activities in any remote terrestrial location supported by an internet or cellular phone infrastructure. The main novel aspects of the system are first, the dry-electrode 12-lead ECG harness itself, and second, an accompanying Android(TM) smart phone-based wireless 12-lead ECG capability. The ECG harness nominally employs dry electrodes manufactured by Orbital Research, Inc, recently cleared through the Food and Drug Administration (FDA). However, other dry electrodes that are not yet FDA cleared, for example those recently developed by Nanosonic, Inc as part of another NASA SBIR grant, can also be used. The various advantageous features of the harness include: 1) laypersons can be quickly instructed on its correct use, remotely if necessary; 2) all tangled "leadwire spaghetti" is eliminated, as is the common clinical problem of "leadwire reversal"; 3) all adhesives and disposables are also eliminated, the harness being fully reusable; if multiple individuals intend to use use the same harness, then standard antimicrobial wipes can be employed to sterilize the dry electrodes (and harness surface if needed) between users; 5) padded cushions at the lateral sides of the torso function to press the left arm (LA) and right arm (RA) dry electrodes mounted on the cushions against sideward or downward-rested arms of the subject; 6) sufficient distal placement of the arm electrodes achieves good electrode abutment to the arms without the need for adhesives, straps, bands, bracelets, or gloves; 7) padding over the sternum avoids "tenting" in the V1 through V3 (and, when present, the V3R) electrode positions; 8) easy-to-don, one-piece design with an adjustable, front-side single point of connection and an adjustable shoulder strap; and 9) Lund or "modified Lund" placement of the dry electrodes, the results of which more effectively reproduce results from "standard" 12-lead ECG placements than do results from Mason-Likar placements. The main limitation of the harness is that "one size does not fit all", meaning that an appropriately sized harness (small, medium, large, etc) must be chosen on the basis of an individual's size. To facilitate the use of the harness with inexpensive, commodity-grade cell phones and tablet devices, 12-lead ECG software is also being developed to accompany the harness for wireless use with Android. For this part of the project, NASA has teamed with TopCoder, Inc and the Harvard-affiliated NASA Tournament Lab in sponsoring java-based software programming contests through TopCoder. While ECG signals from the harness can already be wirelessly received and thoroughly processed (locally or remotely) by commercial-grade conventional (as well as advanced) 12-lead ECG software running on Microsoft Windows(TM), the Android-based software, once completed, will "cast a wider net" by allowing for a greater percentage of cell phone owners to participate in inexpensive, store-and-forward recordings of 12-lead ECGs worldwide, including for example Android cell phone users in many remote, third-world locations. At the time of writing, the Android 12-lead ECG software platform consists of a basic but expanding graphical user interface and accompanying software that: 1) wirelessly receives the 12-lead ECG data stream from a Bluetooth-based, FDA-cleared 12-leaCG device attached to the harness; 2) locally stores the same data in binary format to the SD card on the Android cell phone; and 3) makes the data stream in available in real time, for now to TopCoder's java programming contestants.

Schlegel, Todd T.↗

Processing Particle Data Flows with SmartNICs

Many distributed applications implement complex data flows and need a flexible mechanism for routing data between producers and consumers. Recent advances in programmable network interface cards, or SmartNICs, represent an opportunity to offload data-flow tasks into the network fabric, thereby freeing the hosts to perform other work. System architects in this space face multiple questions about the best way to leverage SmartNICs as processing elements in data flows. In this paper, we advocate the use of Apache Arrow as a foundation for implementing data-flow tasks on SmartNICs. We report on our experiences adapting a partitioning algorithm for particle data to Apache Arrow and measure the on-card processing performance for the BlueField-2 SmartNIC. Our experiments confirm that the BlueField-2’s (de)compression hardware can have a significant impact on in-transit workflows where data must be unpacked, processed, and repacked.

97 MATHEMATICS AND COMPUTING↗