Search NASA⌕ Search

SEARCH · Search NASA

Results for “data exchange model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Studies of Localization Effects on Transverse Kinematic Imbalance in the GENIE Generator

The forthcoming Deep Underground Neutrino Experiment (DUNE) requires precise modeling of neutrino--nucleus interactions to achieve its neutrino-oscillation measurement goals. GENIE, the Monte Carlo event generator used by DUNE and other Fermilab-based experiments as a central value model for neutrino-nucleus cross sections, exhibits known discrepancies in comparison to MicroBooNE cross section data, especially when considering neutrino scattering events' transverse kinematic imbalance (TKI). For quasielastic-like measurements, the data show a larger transverse missing momentum tail while maintaining a peak similar to that predicted by the baseline GENIE model. Previous attempts at a solution include variations of final-state interaction (FSI) strengths, incorrectly decreasing both the peak and tail, thus leaving the discrepancy unresolved. This work investigates whether inconsistencies between local and global treatments of intranuclear physics contribute to the observed mismodeling. In this work, GENIE FSI routines have been modified to directly utilize intranuclear particle positions, thereby introducing a newly localized momentum treatment in correlation with the nominal density in both the hA and hN intranuclear cascade models for their 2018 and 2025 variants. Meson-exchange-current (MEC) localization was also tested for the hN 2018 model. Comparisons of the intranuclear nucleons' ("scattering center") momentum and its radial dependence validate the localization implementation. However, while such consistent localization produces modest changes in the proton momentum spectrum at low-to-medium momenta, only small changes are observed in the TKI distributions. These changes are insufficient to account for the discrepancy with MicroBooNE data. Although a localized treatment improves the internal consistency of the GENIE model, the origin of the TKI discrepancy remains unresolved by such a solution.

Bulla, Braden [Ctr. Coll., Danville; Fermilab]↗

Dynamic Behavior of Oval-Twisted Helical Tube Heat Exchanger: Numerical Study with RELAP5-3D

Convective heat transfer characteristics and theoretical thermal stress behaviors are numerically calculated using RELAP5-3D for the helical-coiled once-through steam generator (H-OTSG) and the novel heat exchanger design known as the oval-twisted helically coiled heat exchanger (OTHCHX) under (1) fluctuating wall temperature conditions, (2) square-wave pulsating flow conditions, and (3) the combined effects of fluctuating wall temperature and square-wave pulsating flow conditions. Heat transfer coefficient models for the H-OTSG and OTHCHX were developed based on existing data and implemented into RELAP5-3D, successfully capturing the N⁢uavg behavior within 8% to 10% of the reported data. Under fluctuating wall temperature conditions, the OTHCHX displayed higher N⁢u avg behavior than the H-OTSG. As 𝑓 increased, the $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ decreased. The $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ was higher for the OTHCHX than for the H-OTSG under fluctuating wall temperature conditions. Under pulsating flow conditions, the H-OTSG and OTHCHX displayed much higher 𝑁⁢𝑢 𝑎𝑣𝑔 than under constant flow conditions. The H-OTSG displayed a higher $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ over the OTHCHX. Under combined fluctuating wall temperature and pulsating flow conditions, the augmented heat transfer behavior from the pulsating flow was counteracted by the wall temperature fluctuations, producing slightly higher 𝑁⁢𝑢 𝑎𝑣𝑔 over constant wall temperature, constant flow conditions, but much lower than only constant pulsating flow under constant wall temperature conditions. The effects of simultaneous wall temperature fluctuations and square-wave pulsating flow caused higher $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ than that of only wall temperature fluctuations or pulsating flow. As the Reynolds number (Re) increased, $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ increased. However, when 𝑓=𝑓$_{\dot{m}}$, the $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ showed decreasing values as Re increased. In conclusion, the results indicate that thermal-fluid resonance can help mitigate thermal stresses.

Thermal stress↗

Plant Physiology, Alder and Willow Species, Seward Peninsula, Alaska, 2019

Photosynthetic parameters (Vcmax and Jmax), CO2 response (ACi) curves and dark respiration (Rdark) measurements of tundra shrub species. Data were collected at the NGEE-Arctic Kougarok and Teller study sites on the Seward Peninsula, AK, USA in July 2019. Four species were measured using LI-COR LI-6400 portable gas exchange systems: Alnus viridis ssp. fruticosa, Salix richardsonii and Salix pulchra. The data package files include data files, metadata files, dGPS locations and the complete instrument output for all gas exchange measurements in .csv format. See the related data packages for foliar trait data (leaf mass per area, leaf nitrogen concentration), and leaf spectral reflectance data collected simultaneously on the same shrubs (NGA210, NGA212).The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Revealing the Crystalline Architecture of Semicrystalline Ion Exchange Membranes for the Design of Conductive and Durable Alkaline Anion Exchange Membranes

Alkaline anion exchange membrane (AAEM) fuel cells offer a cost-effective alternative to proton exchange membrane (PEM) fuel cells by eliminating the need for expensive precious metal catalysts. In both PEMs and AAEMs, semicrystalline polymers are a common choice, as the crystalline domains can act as mechanical reinforcements that limit swelling and promote mechanical durability in the material. However, spatially resolved characterization of crystalline organization in ion exchange membranes beyond ensemble-averaged X-ray scattering is underrepresented, likely in part due to ionization damage limitations in soft materials. Here, in this study, we resolve the nanometer-size crystallites in semicrystalline ion exchange membranes by applying cryogenic four-dimensional scanning transmission electron microscopy (cryo-4D-STEM) along with data-processing algorithms designed to optimize signals at a low dose to minimize radiation damage. We investigate the effects of synthesis components, including molecular weight and thermal treatment, on a model system of AAEMs in comparison to Nafion, the most commonly used and commercially successful PEM today. We find that excess water uptake in polymer membranes, a property directly associated with weak mechanical durability and with possible negative impacts on ion conductivity, can be reduced by over 30% by varying the polymer's crystalline morphology through changes in synthesis parameters such as molecular weight and thermal history. Our results indicate that this improvement is correlated with smaller crystalline domains with a more homogeneous distribution. More broadly, these results demonstrate how the crystalline architecture of polymer membranes can be tuned through their chemistry and thermal treatment in order to improve their conductivity and durability for commercial fuel cell performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

M3SF-24LL010301062-Surface Complexation/Ion Exchange Data Integration for Radionuclide Sorption to Clay Minerals

This progress report (Level 3 Milestone Number M3SF-24LL010301062) summarizes research conducted at Lawrence Livermore National Laboratory (LLNL) within the Argillite International Collaborations Work Package SF-24LL01030106. The activity is focused on our long-term commitment to engaging our partners in international nuclear waste repository research. The focus of this milestone is the establishment of international collaborations for sorption modeling and the associated impacts of unlocking larger, community-based datasets. More specifically, we are developing a database framework for Spent Fuel and Waste and Science Technology (SFWST) that is aligned with the Helmholtz Zentrum Dresden Rossendorf (HZDR) and other international sorption database development groups in support of the database needs of the SFWST program.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Localized Interactions in Neutrino Simulations

The Deep Underground Neutrino Experiment (DUNE) requires precise modeling of neutrino--nucleus interactions to achieve its neutrino-oscillation measurement goals. GENIE, the Monte Carlo event generator used by DUNE, exhibits a known discrepancy with MicroBooNE measurements of transverse kinematic imbalance (TKI): the data display a larger high-TKI tail while maintaining a peak similar to that predicted by the baseline GENIE model. Previous variations of final-state interaction (FSI) strength affected both the peak and the tail and therefore did not resolve the discrepancy. This work investigates whether inconsistencies between local and global treatments of intranuclear physics contribute to the observed mismodeling. The GENIE FSI routines were modified to use the particle position when generating nucleons, thereby introducing a local-density treatment in the hA and hN intranuclear models for their 2018 and 2025 implementations. Meson-exchange-current (MEC) localization was also tested for the hN 2018 model. Comparisons of the intranuclear scattering-center momentum and its radial dependence confirm that the localization was implemented as intended. Localization produces modest changes in the proton momentum spectrum, primarily at low momentum, but only a small change in the TKI distribution between approximately \SI{0.25}{\giga\electronvolt} and \SI{0.40}{\giga\electronvolt}. These changes are insufficient to account for the discrepancy with MicroBooNE data. Although a localized treatment improves the internal consistency of the GENIE model, the origin of the TKI discrepancy remains unresolved.

Bulla, Braden [Unlisted, US, IL]↗

Improving ProtoDUNE pion cross-section measurements with NuGraph Michel-electron tagging

Understanding hadron-argon interactions is essential for precise neutrino energy reconstruction and final-state interaction modeling in liquid-argon time projection chamber (LArTPC) experiments such as DUNE. In particular, pion absorption and charge-exchange processes constitute significant sources of systematic uncertainty in neutrino oscillation measurements. ProtoDUNE-SP, a large-scale LArTPC prototype operated at the CERN Neutrino Platform and exposed to charged-particle test beams in the few-GeV range, enables direct measurements of these processes. This work focuses on the measurement of differential cross sections for pion absorption and charge exchange using the 2 GeV/c pion beam data from the ProtoDUNE-SP run. A key component of this analysis is the identification of Michel electrons from $\pi \rightarrow \mu \rightarrow e$ decay chains, which helps separate different interaction topologies and improves background rejection. Michel electron identification will also assist in reliably calibrating the electromagnetic response in ProtoDUNE-SP data and for the future DUNE detectors. In this analysis, we apply NuGraph to identify Michel electrons. NuGraph is a graph neural network that models detector hits as nodes connected by spatial and temporal edges for particle and topology classification in LArTPC detectors. We first benchmark NuGraph’s Michel electron classification performance using ICEBERG data, a small-scale LArTPC prototype used for DUNE electronics and reconstruction development, and then transfer the approach to ProtoDUNE-SP. This poster presents the analysis strategy, NuGraph-based classification studies, and discusses how these developments are expected to improve the pion cross-section measurement.

Razafinime, Soamasina Herilala [Cincinnati U.] (OR↗

Exploring CO 2 reduction and crossover in membrane electrode assemblies

Electrochemical CO 2 reduction (CO 2 R) using renewable electricity is a key pathway toward synthesizing fuels and chemicals. In this study, multi-physics modeling is used to interpret experimental data obtained for CO 2 R to CO using Ag catalysts in a membrane electrode assembly. The one-dimensional model is validated using measured CO 2 crossover and product formation rates. The kinetics of CO formation are described by Marcus–Hush–Chidsey kinetics, which enables accurate prediction of the experimental data by accounting for the reorganization of the solvent during CO 2 R. Further, the results show how the performance is dictated by competing phenomena including ion formation and transport, CO 2 solubility, and water management. The model shows that increasing the ion-exchange capacity of the membrane and surface area of the catalyst increases CO formation rates by >100 mA cm –2 without negatively impacting CO 2 utilization. Here we provide insights into how to manage the trade-off between productivity and CO 2 utilization in CO 2 electrolyzers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Downscaled Daily 1 km Climate Data (NEX-GDDP-CMIP6) for Southeast Texas. Full ensemble of downscaled CMIP6 climate projections at 1 km daily resolution.

For the SETx-UIFL, the daily NASA Earth Exchange Global Daily Downscaled Projections (NEX-GDDP-CMIP6) dataset climate projections were downscaled from approximately 27 km to 1 km. The SETx dataset provides very high-resolution climate data for the historical period (1950–2014) and future scenarios derived from CMIP6 global models under the four Tier 1 Shared Socioeconomic Pathways (SSPs 1.26, 2.45, 3.70, and 5.85), developed for the IPCC Sixth Assessment Report. A subset of ten NEX-GDDP-CMIP6 models was selected to represent a balance of model families, climate sensitivities, and availability across scenarios, ensuring a diverse and reliable ensemble for regional analysis. Selected models: BCC-CSM2-MR, CESM2, CMCC-ESM2, CNRM-ESM2-1, EC-Earth3, FGOALS-g3, GFDL-CM4, MPI-ESM1-2-HR, MRI-ESM2-0, NorESM2-MM. Daily variables downscaled include tasmax, tasmin, tas, pr, hurs, huss, rsds, rlds, and sfcWind.

Persad, Geeta↗

Vegetation Warming Experiment: Environmental Conditions, Utqiagvik (Barrow), Alaska, 2018

Environmental conditions measured in five warming chambers and paired ambient control plots located on the Barrow Environmental Observatory (BEO), Utqiagvik, Alaska from 16 June - 24 September, 2018. These data were recorded in support of the Zero Power Warming (ZPW) vegetation warming experiment, a series of single season vegetation warming treatments conducted over four years from 2017-2021 (no experiment in 2020). Air temperature and humidity, infrared surface (canopy) temperature, soil temperature, soil moisture, NDVI (normalized difference vegetation index), PRI (photochemical reflectance index), solar radiation and chamber venting were recorded in each chamber at 1 minute intervals. Ambient air temperature, humidity, solar radiation and uplooking PRI and NDVI were measured at a centrally located meteorology station. Vapor pressure deficit (VPD) was calculated and included in the final processed data products. Data has undergone full QA/QC and is presented as 1 minute data, and hourly and daily aggregate data products. This data package includes unprocessed raw data (*.dat files), processed data (*.csv) and metadata including a full description of sensors, calculations and processing (*.csv, *.pdf). See related NGEE-Arctic "Vegetation Warming Experiment" data packages for leaf-level gas exchange and other leaf trait data; chamber, plot and landscape phenocamera images; thaw depth, and GPS locations of chambers and ambient plots.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Vegetation Warming Experiment: Environmental conditions, Utqiagvik (Barrow), Alaska, 2019

Environmental conditions measured in five warming chambers and paired ambient control plots located on the Barrow Environmental Observatory (BEO), Utqiagvik, Alaska from 19 June – 25 September, 2019. These data were recorded in support of the Zero Power Warming (ZPW) vegetation warming experiment, a series of single season vegetation warming treatments conducted over four years from 2017–2021 (no experiment in 2020). Air temperature and humidity, infrared surface (canopy) temperature, soil temperature, soil moisture, NDVI (normalized difference vegetation index), PRI (photochemical reflectance index), solar radiation and chamber venting were recorded in each chamber at 1 minute intervals. Ambient air temperature, humidity, solar radiation and uplooking PRI and NDVI were measured at a centrally located meteorology station. Vapor pressure deficit (VPD) was calculated and included in the final processed data products. Data has undergone full QA/QC and is presented as 1 minute data, and hourly and daily aggregate data products. This data package includes unprocessed raw data (*.dat files), processed data (*.csv) and metadata including a full description of sensors, calculations and processing (*.csv, *.pdf). See related NGEE-Arctic "Vegetation Warming Experiment" data packages for leaf-level gas exchange and other leaf trait data; chamber, plot and landscape phenocamera images; thaw depth, and GPS locations of chambers and ambient plots.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Fast Dynamic Internal Predictive Power Scheduling Approach for Power Management in Microgrids: Preprint

This paper presents a Dynamic Internal Predictive Power Scheduling (DIPPS) approach for optimizing power management in microgrids, particularly focusing on external power exchanges among diverse prosumers. DIPPS utilizes a dynamic objective function with a time-varying binary parameter to control the timing of power transfers to the external grid, facilitated by efficient usage of energy storage for surplus renewable power. The microgrid power scheduling problem is modeled as a mixed-integer nonlinear programming (MINLP-PS) and subsequently transformed into a mixed-integer linear programming (MILPPS) optimization through McCormick's relaxation to reduce computational complexity. A predictive window window with 6 data points is solved at an average of 0.92s, a 97.6% improvement over the 38.27s required for the MINLP-PS formulation, implying the numerical feasibility of the DIPPS approach for real-time implementation. Finally, the approach is validated against a static objective using real-world load data across three case studies with different time-varying parameters, demonstrating the ability of DIPPS to optimize power exchanges and efficiently utilize distributed resources while shifting the external power transfers to specified time durations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Toward first principles-based simulations of dense hydrogen

Accurate knowledge of the properties of hydrogen at high compression is crucial for astrophysics (e.g., planetary and stellar interiors, brown dwarfs, atmosphere of compact stars) and laboratory experiments, including inertial confinement fusion. There exists experimental data for the equation of state, conductivity, and Thomson scattering spectra. However, the analysis of the measurements at extreme pressures and temperatures typically involves additional model assumptions, which makes it difficult to assess the accuracy of the experimental data rigorously. On the other hand, theory and modeling have produced extensive collections of data. They originate from a very large variety of models and simulations including path integral Monte Carlo (PIMC) simulations, density functional theory (DFT), chemical models, machine-learned models, and combinations thereof. At the same time, each of these methods has fundamental limitations (fermion sign problem in PIMC, approximate exchange–correlation functionals of DFT, inconsistent interaction energy contributions in chemical models, etc.), so for some parameter ranges accurate predictions are difficult. Recently, a number of breakthroughs in first principles PIMC as well as in DFT simulations were achieved which are discussed in this review. Here we use these results to benchmark different simulation methods. We present an update of the hydrogen phase diagram at high pressures, the expected phase transitions, and thermodynamic properties including the equation of state and momentum distribution. Furthermore, we discuss available dynamic results for warm dense hydrogen, including the conductivity, dynamic structure factor, plasmon dispersion, imaginary-time structure, and density response functions. We conclude by outlining strategies to combine different simulations to achieve accurate theoretical predictions that are based on first principles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Derivation of low-energy Hamiltonians for heavy-fermion materials

Here, by utilizing a multiorbital periodic Anderson model with parameters obtained from ab initio band structure calculations, combined with degenerate perturbation theory, we derive effective Kondo-Heisenberg and spin Hamiltonians that capture the interaction among the effective magnetic moments. This derivation encompasses fluctuations via both nonmagnetic 4⁢𝑓 0 and magnetic 4⁢𝑓 2 virtual states, and its accuracy is confirmed through comparison with experimental data obtained from CeIn 3 . The significant agreement observed between experimental results and theoretical predictions underscores the potential of deriving minimal models from first-principles calculations for achieving a quantitative description of 4⁢𝑓 materials. Moreover, our microscopic derivation unveils the underlying origin of anisotropy in the exchange interaction between Kramers doublets, shedding light on the conditions under which this anisotropy may be weak compared to the isotropic contribution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-cost fin-tube heat exchanger design for building thermal energy storage using phase change material

Heat transfer in phase change materials (PCMs) is complex because the melting and freezing fronts change as functions of stored or released heat. In prior attempts to optimize heat exchangers (HXs) in one or two dimensions, complex geometry has often been used to maximize the melt and freeze front area. This complex geometry is difficult and hence expensive to construct. This paper proposes a multiple-scale 3D finite element modeling approach to design fin-tube HXs for low-cost latent thermal energy storage applications. Further, the optimal fin and tube designs were determined at three scales (unit-scale, medium-scale, and large-scale) by modeling the melt and freeze front in three dimensions and using measured bulk thermal properties. The finite element model was validated by comparing it with the experimental data for a referenced design of a similar type. The results indicate that commercially available organic PCMs with low conductivity (<0.3 W/m·K) can have charge and discharge times appropriate for building thermal energy storage (i.e., 4–5 h) with fin-tube HX designs at costs <$26/kWh, even when the temperature difference (5.56°C) between the heat transfer fluid and the PCM phase change temperature is small. However, as the HX increases in length, the temperature reduction along the tube limits some larger-scale designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Trends and Drivers of Terrestrial Sources and Sinks of Carbon Dioxide: An Overview of the TRENDY Project

The terrestrial biosphere plays a major role in the global carbon cycle, and there is a recognized need for regularly updated estimates of land-atmosphere exchange at regional and global scales. An international ensemble of Dynamic Global Vegetation Models (DGVMs), known as the “Trends and drivers of the regional scale terrestrial sources and sinks of carbon dioxide” (TRENDY) project, quantifies land biophysical exchange processes and biogeochemistry cycles in support of the annual Global Carbon Budget assessments and the REgional Carbon Cycle Assessment and Processes, phase 2 project. DGVMs use a common protocol and set of driving data sets. A set of factorial simulations allows attribution of spatio-temporal changes in land surface processes to three primary global change drivers: changes in atmospheric CO 2 , climate change and variability, and Land Use and Land Cover Changes (LULCC). Here, we describe the TRENDY project, benchmark DGVM performance using remote-sensing and other observational data, and present results for the contemporary period. Simulation results show a large global carbon sink in natural vegetation over 2012–2021, attributed to the CO 2 fertilization effect (3.8 ± 0.8 PgC/yr) and climate (–0.58 ± 0.54 PgC/yr). Forests and semi-arid ecosystems contribute approximately equally to the mean and trend in the natural land sink, and semi-arid ecosystems continue to dominate interannual variability. The natural sink is offset by net emissions from LULCC (–1.6 ± 0.5 PgC/yr), with a net land sink of 1.7 ± 0.6 PgC/yr. Despite the largest gross fluxes being in the tropics, the largest net land-atmosphere exchange is simulated in the extratropical regions.

58 GEOSCIENCES↗

Preliminary modeling of triply periodic minimal surface (TPMS) structures using RELAP5-3D

With the United States Department of Energy (DOE)’s goal of quadrupling the nation’s nuclear energy supply by 2050, and with the Advanced Fuels Campaign pushing for new types of advanced reactor fuels and geometries, the need has arisen for new nuclear fuel designs. One such design is to swap out current nuclear fuel geometries in exchange for another type of geometry, called a Triply Periodic Minimal Surface (TPMS). TPMSs are self-supporting, infinitely repeating lattices—attributes that lend themselves well to additive manufacturing. These surfaces also possess enhanced heat transfer properties thanks to their internal area changes and large surface-area-to-volume ratios. Their drawback, however, is an increased pressure drop. Given the small amount of correlations and data (Reynolds numbers in the 2,000–8,000 range), and the minimal amount of experience so far obtained by modeling TPMS structures using 1D systems codes such as the Reactor Excursion and Leak Analysis Program (RELAP5-3D), further research into this topic was needed. Using data from the University of Wisconsin - Madison (UW), curve fits were created for both a Heat Transfer Coefficient (HTC) correlation and a Darcy friction factor empirical coefficient correlation. The curves’ coefficients and multipliers were then output and utilized in RELAP5-3D models of two upcoming experiments—Flow Loop for INFLUX Pressure drop (FLIP) and Microreactor Agile Non-nuclear Experimental Test (MAGNET)—aimed at increasing the available data for Reynolds numbers to the 16,000–36,000 range for TPMS structures. The models were run under the conditions utilized by a Computational Fluid Dynamics (CFD) analysis performed by another group at Idaho National Laboratory. Only CFD pressure drop values were obtained from the FLIP test, and those values showed that the RELAP5-3D models had a lower rate of pressure increase in comparison to the CFD values. In addition, there seemed to be a vertical shift upward in the pressure drop for both models whenever the TPMS porosity decreased, and the RELAP5-3D models showed a higher vertical shift in comparison to the CFD values. The MAGNET results did not correspond to any CFD or experimental results against which they could be compared, so they were instead compared against the proposed CFD input conditions. These values were then compared with each other to make sure the model seemed to be performing as expected, paving the way for future tests that can be run for the purpose of further analyses and comparisons. The pressure drop increased with temperature and mass flow rate independently. The temperature change would decrease with increasing mass flow rate and temperature, which was just as we expected based on the fact that the lower viscosity and decreased density would result in higher friction and churning losses. The last metric that was assessed was the enthalpy flow change, which increased with increasing mass flow rate and decreasing temperature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗