Search NASA⌕ Search

SEARCH · Search NASA

Results for “data fidelity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A novel digital tomosynthesis (DTS) reconstruction method using a deformation field map

We developed a novel digital tomosynthesis (DTS) reconstruction method using a deformation field map to optimally estimate volumetric information in DTS images. The deformation field map is solved by using prior information, a deformation model, and new projection data. Patients' previous cone-beam CT (CBCT) or planning CT data are used as the prior information, and the new patient volume to be reconstructed is considered as a deformation of the prior patient volume. The deformation field is solved by minimizing bending energy and maintaining new projection data fidelity using a nonlinear conjugate gradient method. The new patient DTS volume is then obtained by deforming the prior patient CBCT or CT volume according to the solution to the deformation field. This method is novel because it is the first method to combine deformable registration with limited angle image reconstruction. The method was tested in 2D cases using simulated projections of a Shepp-Logan phantom, liver, and head-and-neck patient data. The accuracy of the reconstruction was evaluated by comparing both organ volume and pixel value differences between DTS and CBCT images. In the Shepp-Logan phantom study, the reconstructed pixel signal-to-noise ratio (PSNR) for the 60 deg. DTS image reached 34.3 dB. In the liver patient study, the relative error of the liver volume reconstructed using 60 deg. projections was 3.4%. The reconstructed PSNR for the 60 deg. DTS image reached 23.5 dB. In the head-and-neck patient study, the new method using 60 deg. projections was able to reconstruct the 8.1 deg. rotation of the bony structure with 0.0 deg. error. The reconstructed PSNR for the 60 deg. DTS image reached 24.2 dB. In summary, the new reconstruction method can optimally estimate the volumetric information in DTS images using 60 deg. projections. Preliminary validation of the algorithm showed that it is both technically and clinically feasible for image guidance in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification and Validation Activities for the Multi-Fidelity Toolkit

The Multi-Fidelity Toolkit (MFTK) is a simulation tool being developed at Sandia National Laboratories for aerodynamic predictions of compressible flows over a range of physics fidelities and computational speeds. These models include the Reynolds-Averaged-Navier-Stokes (RANS) equations, the Euler equations, and modified Newtonian aerodynamics (MNA) equations, and they can be invoked independently or coupled with hierarchical Kriging to interpolate between high-fidelity simulations using lower-fidelity data. However, as with any new simulation capability, verification and validation are necessary to gather credibility evidence. This work describes formal code- and solution-verification activities as well as model validation with uncertainty considerations. Code verification is performed on the MNA model by comparing with an analytical solution for flat-plate and inclined-plate geometries. Solution-verification activities include grid-refinement studies of HIFiRE-1 wind tunnel measurements, which are used for validation, for all model fidelities. A thorough treatment of the validation comparison with prediction error and validation uncertainty is also presented.

42 ENGINEERING↗

An adaptive regularization parameter choice strategy for multispectral bioluminescence tomography

Purpose: Bioluminescence tomography (BLT) provides an effective tool for monitoring physiological and pathological activities in vivo. However, the measured data in bioluminescence imaging are corrupted by noise. Therefore, regularization methods are commonly used to find a regularized solution. Nevertheless, for the quality of the reconstructed bioluminescent source obtained by regularization methods, the choice of the regularization parameters is crucial. To date, the selection of regularization parameters remains challenging. With regards to the above problems, the authors proposed a BLT reconstruction algorithm with an adaptive parameter choice rule. Methods: The proposed reconstruction algorithm uses a diffusion equation for modeling the bioluminescent photon transport. The diffusion equation is solved with a finite element method. Computed tomography (CT) images provide anatomical information regarding the geometry of the small animal and its internal organs. To reduce the ill-posedness of BLT, spectral information and the optimal permissible source region are employed. Then, the relationship between the unknown source distribution and multiview and multispectral boundary measurements is established based on the finite element method and the optimal permissible source region. Since the measured data are noisy, the BLT reconstruction is formulated as l{sub 2} data fidelity and a general regularization term. When choosing the regularization parameters for BLT, an efficient model function approach is proposed, which does not require knowledge of the noise level. This approach only requests the computation of the residual and regularized solution norm. With this knowledge, we construct the model function to approximate the objective function, and the regularization parameter is updated iteratively. Results: First, the micro-CT based mouse phantom was used for simulation verification. Simulation experiments were used to illustrate why multispectral data were used rather than monochromatic data. Furthermore, the study conducted using an adaptive regularization parameter demonstrated our ability to accurately localize the bioluminescent source. With the adaptively estimated regularization parameter, the reconstructed center position of the source was (20.37, 31.05, 12.95) mm, and the distance to the real source was 0.63 mm. The results of the dual-source experiments further showed that our algorithm could localize the bioluminescent sources accurately. The authors then presented experimental evidence that the proposed algorithm exhibited its calculated efficiency over the heuristic method. The effectiveness of the new algorithm was also confirmed by comparing it with the L-curve method. Furthermore, various initial speculations regarding the regularization parameter were used to illustrate the convergence of our algorithm. Finally, in vivo mouse experiment further illustrates the effectiveness of the proposed algorithm. Conclusions: Utilizing numerical, physical phantom and in vivo examples, we demonstrated that the bioluminescent sources could be reconstructed accurately with automatic regularization parameters. The proposed algorithm exhibited superior performance than both the heuristic regularization parameter choice method and L-curve method based on the computational speed and localization error.

61 RADIATION PROTECTION AND DOSIMETRY↗

High Fidelity Simulations of Air-Cooled Reactor Cavity Cooling System

Nuclear energy is increasingly acknowledged as pivotal in the global shift towards cleaner energy solutions. Advanced nuclear technologies, including High Temperature Gas-cooled Reactors (HTGRs), stand out as appealing options among Generation IV reactors due to their high temperature heat output and potential for cogeneration. HTGR designs incorporate passive safety systems, such as the Reactor Cavity Cooling System (RCCS), which utilize natural principles to manage heat dissipation from the reactor pressure vessel (RPV) during accidents or routine shutdowns. Regulatory bodies require thorough validation of safety systems like the RCCS to ensure they meet specified standards. Consequently, there is a pressing need within the industry for advanced simulation tools capable of assessing these systems’ performance accurately. There is a knowladge gap in the literature concerning high-fidelity data for the RCCS, which motivates the focus of this study. This research focuses on a specific RCCS designed for the Modular High-Temperature Gas Reactor developed by General Atomics (GA- MHTGR). Experimental studies on a scaled version of the air-cooled RCCS of GA-MHTGR were conducted by the University of Wisconsin-Madison. This work contributes to a broader initiative aimed at establishing a numerical benchmark based on the UW-Madison experiments. As first step we performed high fidelity simulations of the experimental facility setup, to analyze flow physics in such systems and validate NekRS and the MOOSE heat transfer and radiation modules.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

2025 Advances in NekRS: Supporting improved performance for nuclear applications

This report presents several 2025 advancements in NekRS, a high-fidelity spectral element CFD code developed at Argonne National Laboratory to support the NEAMS thermal-hydraulics program. The forthcoming v25 release consolidates several of these advances, adding new features for portability across heterogeneous GPU architectures, real-time in situ visualization, improved turbulence modeling, and conjugate heat transfer coupling. Over the past year, NekRS has demonstrated strong scalability and performance on DOE’s leading exascale platforms, including Aurora and Frontier, confirming its readiness for some of the largest and most complex simulations attempted to date. These achievements provide a powerful new platform for high-fidelity data generation, which in turn supports the development and validation of advanced closure models critical for reactor safety and design. Significant algorithmic innovations have also been introduced. A new global runtime h-refinement capability simplifies workflows by reducing mesh preparation burdens and enabling coarse-to-fine restarts. Building on this, a novel multigrid strategy was implemented to accelerate pressure and transport solves at scale, addressing long-standing bottlenecks in exascale CFD. Together, these developments improve both the efficiency and accessibility of high-fidelity simulations for reactor-relevant problems. Collectively, these enhancements represent a major step forward in simulation technology, positioning NekRS as a cornerstone of NEAMS efforts to enable accurate, efficient, and scalable high-fidelity analysis of advanced nuclear systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Behavior of Ullage Bubbles During Blowdown in Low-g Experiment (BUBBLE): Overview of a Cryogenic Tank Depressurization Test

Behavior of Ullage Bubbles during Blowdown in Low-g Experiment (BUBBLE) is a cryogenic tank depressurization drop tower experiment currently being designed at NASA Glenn Research Center. There is a need for liquid level rise data while venting a cryogenic propellant tank below the liquid saturation pressure in a reduced gravity environment. When a cryogenic tank is vented to a vapor pressure below the liquid saturation pressure, bubbles become entrained in the liquid causing the bulk liquid-vapor interface to rise. In reduced gravity, bubble rise velocity is diminished leading to a larger liquid level rise compared to a 1g environment. The purpose of the experiment is to gain further understanding of tank depressurization fluid physics and obtain high-fidelity data for model validation in 1g and reduced gravity environments. On-orbit cryogenic propellant tanks operating at high fill levels must efficiently manage venting operations to avoid the risk of liquid entrainment in the vent line, which could lead to asymmetric control thruster loads, freezing and clogging, and loss of liquid propellant. Validated models could be used to design settling and venting profiles to reduce risk and increase efficiency for cryogenic storage and transfer operations.

tank venting↗

Validation/Uncertainty Quantification for Large Eddy Simulations of the heat flux in the Tangentially Fired Oxy-Coal Alstom Boiler Simulation Facility

The objective of this task is to produce predictive capability with quantified uncertainty bounds for the heat flux in commercial-scale, tangentially fired, oxy-coal boilers. Validation data came from the Alstom Boiler Simulation Facility (BSF) for tangentially fired, oxy-coal operation. This task brings together experimental data collected under Alstom’s DOE project for measuring oxy-firing performance parameters in the BSF with this University of Utah project for large eddy simulation (LES) and validation/uncertainty quantification (V/UQ). The Utah work includes V/UQ with measurements in the single-burner facility where advanced strategies for O2 injection can be more easily controlled and data more easily obtained. Highlights of the work include: • Simulations of Alstom’s 15 megawatt (MW) BSF, exploring the uncertainty in thermal boundary conditions. A V/UQ analysis showed consistency between experimental results and simulation results, identifying uncertainty bounds on the quantities of interest for this system (Subtask 9.1) • A simulation study of the University of Utah’s oxy-fuel combustor (OFC) focused on heat flux (Subtask 9.2). A V/UQ analysis was used to show consistency between experimental and simulation results. • Measurement of heat flux and temperature with new optical diagnostic techniques and comparison with conventional measurements (Subtask 9.3). Various optical diagnostics systems were created to provide experimental data to the simulation team. The final configuration utilized a mid-wave infrared (MWIR) camera to measure heat flux and temperature, which was synchronized with a high-speed, visible camera to utilize two-color pyrometry to measure temperature and soot concentration. • Collection of heat flux and temperature measurements in the University of Utah’s OFC for use is subtasks 9.2 and 9.3 (Subtask 9.4). Several replicates were carried to better assess the experimental error. Experiments were specifically designed for the generation of high-fidelity data from a turbulent oxy-coal flame for the validation of oxy-coal simulation models. Experiments were also conducted on the OFC to determine heat flux profiles using advanced strategies for O2 injection. This is important when considering retrofit of advanced O2 injection in retrofit configurations.

Smith, P.J.↗

Towards improved mesh-designing techniques of spark-ignition engines in the framework of spectral element methods

In the current paper we present an advanced meshing technique to perform high-fidelity numerical simulations in spark ignition (SI) engines. The design of the mesh is critical towards generating physically consistent, high fidelity data especially in regions of complex boundaries inside the cylinder, e.g., near the spark plugs. This is primarily due to the mesh deformation caused by the motion of the valve near the plug and also finer mesh sizes in the spark plug region. In the current work, we demonstrate the use of an overlapping grid (overset) methodology to design the mesh in the spark-plug region in a 2D SI engine-like geometry for a high-order simulation, based on the spectral element method (SEM). The data in the overlapping region is exchanged between the spark-plug geometry and the geometry containing rest of the objects like the piston, cylinder head, valve etc., using a high order spectral interpolation technique. The numerical simulations have been further compared against the standard, single (non-overset) grid, meshing technique for the whole 2D domain. The results further illustrate the capability of overlapping grid methodology in handling mesh deformation compared to the standard grid case and also the ability to capture the flow dynamics with a similar level of fidelity as the standard one

overlapping grids↗

Super-resolution model for overlapping peak detection and improved spatial resolution in high-energy diffraction microscopy

Reconstruction quality in Far-field High-Energy Diffraction Microscopy (FF-HEDM) is limited by the spatial resolution of area detectors and the frequent occurrence of overlapping diffraction spots. To address these challenges, we developed a super-resolution (SR) framework using convolutional neural networks (CNNs) to recreate 2D diffraction peaks at up to ×8 resolution from raw detector data. A specialized simulation tool was created to generate synthetic training datasets with varying degrees of peak overlap. Integrated into the Microstructural Imaging using Diffraction Analysis Software (MIDAS), the SR model improves the spatial accuracy and precision of 3D grain reconstruction by an order of magnitude. This approach provides a robust solution for investigation of complex micromechanical states and material classes where the analysis is limited by the presence of overlapping peaks. Furthermore, the methodology developed here can potentially be extended to other techniques that require sub-pixel accuracy for high-fidelity data analysis.

High-energy diffraction microscopy↗

SU-E-I-45: Reconstruction of CT Images From Sparsely-Sampled Data Using the Logarithmic Barrier Method

Purpose: To develop and investigate whether the logarithmic barrier (LB) method can result in high-quality reconstructed CT images using sparsely-sampled noisy projection data Methods: The objective function is typically formulated as the sum of the total variation (TV) and a data fidelity (DF) term with a parameter λ that governs the relative weight between them. Finding the optimized value of λ is a critical step for this approach to give satisfactory results. The proposed LB method avoid using λ by constructing the objective function as the sum of the TV and a log function whose augment is the DF term. Newton's method was used to solve the optimization problem. The algorithm was coded in MatLab2013b. Both Shepp-Logan phantom and a patient lung CT image were used for demonstration of the algorithm. Measured data were simulated by calculating the projection data using radon transform. A Poisson noise model was used to account for the simulated detector noise. The iteration stopped when the difference of the current TV and the previous one was less than 1%. Results: Shepp-Logan phantom reconstruction study shows that filtered back-projection (FBP) gives high streak artifacts for 30 and 40 projections. Although visually the streak artifacts are less pronounced for 64 and 90 projections in FBP, the 1D pixel profiles indicate that FBP gives noisier reconstructed pixel values than LB does. A lung image reconstruction is presented. It shows that use of 64 projections gives satisfactory reconstructed image quality with regard to noise suppression and sharp edge preservation. Conclusion: This study demonstrates that the logarithmic barrier method can be used to reconstruct CT images from sparsely-amped data. The number of projections around 64 gives a balance between the over-smoothing of the sharp demarcation and noise suppression. Future study may extend to CBCT reconstruction and improvement on computation speed.

60 APPLIED LIFE SCIENCES↗

THE CDF ARCHIVE: HERSCHEL PACS AND SPIRE SPECTROSCOPIC DATA PIPELINE AND PRODUCTS FOR PROTOSTARS AND YOUNG STELLAR OBJECTS

We present the COPS-DIGIT-FOOSH (CDF) Herschel spectroscopy data product archive, and related ancillary data products, along with data fidelity assessments, and a user-created archive in collaboration with the Herschel-PACS and SPIRE ICC groups. Our products include datacubes, contour maps, automated line fitting results, and best 1D spectra products for all protostellar and disk sources observed with PACS in RangeScan mode for two observing programs: the DIGIT Open Time Key Program (KPOT-nevans-1 and SDP-nevans-1; PI: N. Evans), and the FOOSH Open Time Program (OT1-jgreen02-2; PI: J. Green). In addition, we provide our best SPIRE-FTS spectroscopic products for the COPS Open Time Program (OT2-jgreen02-6; PI: J. Green) and FOOSH sources. We include details of data processing, descriptions of output products, and tests of their reliability for user applications. We identify the parts of the data set to be used with caution. The resulting absolute flux calibration has improved in almost all cases. Compared to previous reductions, the resulting rotational temperatures and numbers of CO molecules have changed substantially in some sources. On average, however, the rotational temperatures have not changed substantially (<2%), but the number of warm (T{sub rot} ∼ 300 K) CO molecules has increased by about 18%.

79 ASTRONOMY AND ASTROPHYSICS↗

An l1-TV algorithm for deconvolution with salt and pepper noise

There has recently been considerable interest in applying Total Variation with an {ell}{sup 1} data fidelity term to the denoising of images subject to salt and pepper noise, but the extension of this formulation to more general problems, such as deconvolution, has received little attention, most probably because most efficient algorithms for {ell}{sup 1}-TV denoising can not handle more general inverse problems. We apply the Iteratively Reweighted Norm algorithm to this problem, and compare performance with an alternative algorithm based on the Mumford-Shah functional.

99 GENERAL AND MISCELLANEOUS↗

Process-Structure-Property Modeling for Severe Plastic Deformation Processes Using Orientation Imaging Microscopy and Data-Driven Techniques

Machining is a severe plastic deformation process, wherein the workpiece material is subjected to high deformation rates and temperatures. During metal machining, the dynamic recrystallization mechanism causes grain refinement into the sub-micron range. In this study, we investigate the microstructure evolution of oxygen-free high conductivity copper (OFHC Cu) subject to a machining process where the cutting speed and rake angle are controlled to manipulate the process strain, strain rate, and temperatures. Microstructures of the deformed chips are quantified using orientation imaging microscopy and novel statistical descriptors that capture the morphology and local lattice misorientations generated during the several mechanistic stages of the dynamic recrystallization process. Mechanical properties of the resulting chips are quantified using spherical nanoindentation protocols. A multiple output Gaussian process regression model is used to simultaneously model the structure-property evolution, which differs from more common approaches that establish such relationships sequentially. This modeling strategy is particularly attractive since it can flexibly provide both structure and property uncertainty estimates. In addition, the statistical modeling framework allows for the inclusion of multi-fidelity data. The statistical metrics utilized serve as efficient microstructure descriptors, which retain the physics of the observed structures without having to introduce ad hoc microstructure feature definitions.

36 MATERIALS SCIENCE↗

Expanded verification and validation studies of hypersonic aerodynamics with multiple physics-fidelity models

Hypersonic aerothermodynamics is an important domain of modern multiphysics simulation. The Multi-Fidelity Toolkit is a simulation tool being developed at Sandia National Laboratories to predict aerodynamic properties for compressible flows from a range of physics fidelities and computational speeds. These models include the Reynolds-averaged Navier–Stokes (RANS) equations, the Euler equations with momentum-energy integral technique (MEIT), and modified Newtonian aerodynamics with flat-plate boundary layer (MNA+FPBL) equations, and they can be invoked independently or coupled with hierarchical Kriging to interpolate between high-fidelity simulations using lower-fidelity data. However, as with any new simulation capability, verification and validation are necessary to gather credibility evidence. This work describes formal code- and solution-verification activities, as well as model validation with uncertainty considerations. Code verification activities on the MNA+FPBL model build on previous work by focusing on the viscous portion of the model. Viscous quantities of interest are compared against those from an analytical solution for flat-plate, inclined-plate, and cone geometries. The code verification methodology for the MEIT model is also presented. Test setup and results of code verification tests on the laminar and turbulent models within MEIT are shown. Solution-verification activities include grid-refinement studies on simulations that model the HIFiRE-1 wind tunnel experiments. These experiments are used for validation of all model fidelities. A thorough validation comparison with prediction error and uncertainty is also presented. Three additional HIFiRE-1 experimental runs are simulated in this study, and the solution verification and validation work examines the effects of the associated parameter changes on model performance. Finally, a study is presented that compares the computational costs and fidelities from each of the different models.

42 ENGINEERING↗

A Survey on Error-Bounded Lossy Compression for Scientific Datasets

Error-bounded lossy compression has been effective in significantly reducing the data storage/transfer burden while preserving the reconstructed data fidelity very well. Many error-bounded lossy compressors have been developed for a wide range of parallel and distributed use cases for years. They are designed with distinct compression models and principles, such that each of them features particular pros and cons. In this article, we provide a comprehensive survey of emerging error-bounded lossy compression techniques. The key contribution is fourfold. (1) We summarize a novel taxonomy of lossy compression into six classic models. (2) We provide a comprehensive survey of 10 commonly used compression components/modules. (3) We summarized pros and cons of 47 state-of-the-art lossy compressors and present how state-of-the-art compressors are designed based on different compression techniques. (4) We discuss how customized compressors are designed for specific scientific applications and use-cases. We believe this survey is useful to multiple communities including scientific applications, high-performance computing, lossy compression, and big data.

Error-Bounded Lossy Compression↗

WE-EF-207-07: Dual Energy CT with One Full Scan and a Second Sparse-View Scan Using Structure Preserving Iterative Reconstruction (SPIR)

Purpose: Conventional dual energy CT (DECT) reconstructs CT and basis material images from two full-size projection datasets with different energy spectra. To relax the data requirement, we propose an iterative DECT reconstruction algorithm using one full scan and a second sparse-view scan by utilizing redundant structural information of the same object acquired at two different energies. Methods: We first reconstruct a full-scan CT image using filtered-backprojection (FBP) algorithm. The material similarities of each pixel with other pixels are calculated by an exponential function about pixel value differences. We assume that the material similarities of pixels remains in the second CT scan, although pixel values may vary. An iterative method is designed to reconstruct the second CT image from reduced projections. Under the data fidelity constraint, the algorithm minimizes the L2 norm of the difference between pixel value and its estimation, which is the average of other pixel values weighted by their similarities. The proposed algorithm, referred to as structure preserving iterative reconstruction (SPIR), is evaluated on physical phantoms. Results: On the Catphan600 phantom, SPIR-based DECT method with a second 10-view scan reduces the noise standard deviation of a full-scan FBP CT reconstruction by a factor of 4 with well-maintained spatial resolution, while iterative reconstruction using total-variation regularization (TVR) degrades the spatial resolution at the same noise level. The proposed method achieves less than 1% measurement difference on electron density map compared with the conventional two-full-scan DECT. On an anthropomorphic pediatric phantom, our method successfully reconstructs the complicated vertebra structures and decomposes bone and soft tissue. Conclusion: We develop an effective method to reduce the number of views and therefore data acquisition in DECT. We show that SPIR-based DECT using one full scan and a second 10-view scan can provide high-quality DECT images and accurate electron density maps as conventional two-full-scan DECT.

60 APPLIED LIFE SCIENCES↗

Detection of multi-reference character imbalances enables a transfer learning approach for virtual high throughput screening with coupled cluster accuracy at DFT cost

Appropriately identifying and treating molecules and materials with significant multi-reference (MR) character is crucial for achieving high data fidelity in virtual high-throughput screening (VHTS). Despite development of numerous MR diagnostics, the extent to which a single value of such a diagnostic indicates the MR effect on a chemical property prediction is not well established. We evaluate MR diagnostics for over 10 000 transition-metal complexes (TMCs) and compare to those for organic molecules. We observe that only some MR diagnostics are transferable from one chemical space to another. By studying the influence of MR character on chemical properties (i.e., MR effect) that involve multiple potential energy surfaces (i.e., adiabatic spin splitting, ΔE H–L , and ionization potential, IP), we show that differences in MR character are more important than the cumulative degree of MR character in predicting the magnitude of an MR effect. Motivated by this observation, we build transfer learning models to predict CCSD(T)-level adiabatic ΔE H–L and IP from lower levels of theory. By combining these models with uncertainty quantification and multi-level modeling, we introduce a multi-pronged strategy that accelerates data acquisition by at least a factor of three while achieving coupled cluster accuracy (i.e., to within 1 kcal mol –1 MAE) for robust VHTS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Fidelity Simulations of Air-Cooled Reactor Cavity Cooling System

High Temperature Gas Reactor (HTGR) designs incorporate passive safety systems (e.g., the Reactor Cavity Cooling System [RCCS]) that utilize natural principles to manage heat dissipation from the reactor pressure vessel (RPV) during accidents or routine shutdowns. The industry community is experiencing a pressing need for advanced simulation tools that can accurately assess the performance of these types of systems. In the literature, a knowledge gap exists concerning high-fidelity data for the RCCS, and this gap is one of the areas of focus of the present study. This research focuses on a specific RCCS designed for General Atomics' Modular High-Temperature Gas Reactor (GA-MHTGR). Experimental studies on a scaled version (can be seen in Figure 1) of the air-cooled RCCS used in GA-MHTGR were conducted by the University of Wisconsin-Madison (UW-Madison). This work contributes to a broader initiative aimed at establishing a numerical benchmark based on the UW-Madison experiments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗