Search NASA⌕ Search

SEARCH · Search NASA

Results for “data fidelity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

NSFnets (Navier-Stokes flow nets): Physics-informed neural networks for the incompressible Navier-Stokes equations

In the last 50 years there has been a tremendous progress in solving numerically the Navier-Stokes equations using finite differences, finite elements, spectral, and even meshless methods. Yet, in many real cases, we still cannot incorporate seamlessly (multi-fidelity) data into existing algorithms, and for industrial-complexity applications the mesh generation is time consuming and still an art. Moreover, solving ill-posed problems (e.g., lacking boundary conditions) or inverse problems is often prohibitively expensive and requires different formulations and new computer codes. Here, we employ physics-informed neural networks (PINNs), encoding the governing equations directly into the deep neural network via automatic differentiation, to overcome some of the aforementioned limitations for simulating incompressible laminar and turbulent flows. We develop the Navier-Stokes flow nets (NSFnets) by considering two different mathematical formulations of the Navier-Stokes equations: the velocity-pressure (VP) formulation and the vorticity-velocity (VV) formulation. Since this is a new approach, we first select some standard benchmark problems to assess the accuracy, convergence rate, computational cost and flexibility of NSFnets; analytical solutions and direct numerical simulation (DNS) databases provide proper initial and boundary conditions for the NSFnet simulations. The spatial and temporal coordinates are the inputs of the NSFnets, while the instantaneous velocity and pressure fields are the outputs for the VP-NSFnet, and the instantaneous velocity and vorticity fields are the outputs for the VV-NSFnet. This is unsupervised learning and, hence, no labeled data are required beyond boundary and initial conditions and the fluid properties. The residuals of the VP or VV governing equations, together with the initial and boundary conditions, are embedded into the loss function of the NSFnets. No data is provided for the pressure to the VP-NSFnet, which is a hidden state and is obtained via the incompressibility constraint without extra computational cost. Unlike the traditional numerical methods, NSFnets inherit the properties of neural networks (NNs), hence the total error is composed of the approximation, the optimization, and the generalization errors. Here, we empirically attempt to quantify these errors by varying the sampling (“residual”) points, the iterative solvers, and the size of the NN architecture. For the laminar flow solutions, we show that both the VP and the VV formulations are comparable in accuracy but their best performance corresponds to different NN architectures. The initial convergence rate is fast but the error eventually saturates to a plateau due to the dominance of the optimization error. For the turbulent channel flow, we show that NSFnets can sustain turbulence at , but due to expensive training we only consider part of the channel domain and enforce velocity boundary conditions on the subdomain boundaries provided by the DNS data base. We also perform a systematic study on the weights used in the loss function for balancing the data and physics components, and investigate a new way of computing the weights dynamically to accelerate training and enhance accuracy. In the last part, we demonstrate how NSFnets should be used in practice, namely for ill-posed problems with incomplete or noisy boundary conditions as well as for inverse problems. We obtain reasonably accurate solutions for such cases as well without the need to change the NSFnets and at the same computational cost as in the forward well-posed problems. As a result, we also present a simple example of transfer learning that will aid in accelerating the training of NSFnets for different parameter settings.

97 MATHEMATICS AND COMPUTING↗

Microbeam synchrotron radiation diffraction and fluorescence of oxide layers formed on zirconium alloys at different corrosion temperatures

Autoclave corrosion tests of Zircaloy-4 were performed at temperatures ranging from 274°C to 427 °C to determine how the characteristics of the oxide layer changed with corrosion temperature. Corroded samples were prepared in cross-section and examined at the Advanced Photon Source using x-ray diffraction and fluorescence with sub-micron spatial resolution. These measurements provide high fidelity data for characterization of the oxide layer grown on zirconium alloys over a range of temperatures to better understand the fundamental mechanisms of corrosion. It was found that the size of the monoclinic oxide grains increases with distance from the metal-oxide interface, while the average grain size of the tetragonal oxide phase decreases. This is consistent with the continuous nucleation of a mixture of equiaxed tetragonal and monoclinic grains at the metal-oxide interface, of which only the monoclinic oxide grains that are properly aligned to minimize stresses grow into long columnar oxide grains. The tetragonal phase oxide grains transform to monoclinic oxide once a critical size is reached. While the monoclinic oxide grain size increases with corrosion temperature, the tetragonal phase grain size remains below a maximum value. Evolution of the tetragonal fraction, calculated with the Garvie-Nicholson formula, was observed, with local maxima seen just before transition and local minima seen at oxide locations corresponding to the oxide kinetic transition. No difference was observed in the tetragonal phase fraction in the oxide layers formed at different corrosion temperatures. Detailed fluorescence and diffraction mapping of one sample showed the evolution of the diffraction intensity over a short range in the oxide. In conclusion, this work provides a systematic study revealing fundamental characteristics of the microstructure of Zircaloy-4 oxide layers to further understanding of corrosion resistance of these materials.

36 MATERIALS SCIENCE↗

Deep learning of experimental electrochemistry for battery cathodes across diverse compositions

Artificial intelligence (AI) has emerged as a tool for discovering and optimizing novel battery materials. However, the adoption of AI in battery cathode representation and discovery is still limited due to the complexity of optimizing multiple performance properties and the scarcity of high-fidelity data. Here, we present a machine learning model (DRXNet) for battery informatics and demonstrate the application in the discovery and optimization of disordered rocksalt (DRX) cathode materials. We have compiled the electrochemistry data of DRX cathodes over the past 5 years, resulting in a dataset of more than 19,000 discharge voltage profiles on diverse chemistries spanning 14 different metal species. Learning from this extensive dataset, our DRXNet model can capture critical features in the cycling curves of DRX cathodes under various conditions. Our approach offers a data-driven solution to facilitate the rapid identification of novel cathode materials, accelerating the development of next-generation batteries for carbon neutralization.

25 ENERGY STORAGE↗

DDxNet: a deep learning model for automatic interpretation of electronic health records, electrocardiograms and electroencephalograms

Effective patient care mandates rapid, yet accurate, diagnosis. With the abundance of non-invasive diagnostic measurements and electronic health records (EHR), manual interpretation for differential diagnosis has become time-consuming and challenging. This has led to wide-spread adoption of AI-powered tools, in pursuit of improving accuracy and efficiency of this process. While the unique challenges presented by each modality and clinical task demand customized tools, the cumbersome process of making problem-specific choices has triggered the critical need for a generic solution to enable rapid development of models in practice. In this spirit, we develop DDxNet, a deep architecture for time-varying clinical data, which we demonstrate to be well-suited for diagnostic tasks involving different modalities (ECG/EEG/EHR), required level of characterization (abnormality detection/phenotyping) and data fidelity (single-lead ECG/22-channel EEG). Using multiple benchmark problems, we show that DDxNet produces high-fidelity predictive models, and sometimes even provides significant performance gains over problem-specific solutions.

60 APPLIED LIFE SCIENCES↗

High-Fidelity Velocity and Concentration Measurements of Turbulent Buoyant Jets

Accurate models of turbulent buoyant flows are essential for the design of the cooling circuit of nuclear reactors and passive safety systems. However, available models fail to fully capture the physics of turbulent mixing when buoyancy becomes predominant with respect to momentum. Therefore, high-fidelity experiments of well-controlled fundamental flows are needed to develop and validate more accurate models. We analyze experiments of positive and negative turbulent buoyant jets, both in uniform and stratified environments, with the aim of understanding the thermal hydraulics of turbulent mixing with variable density and providing high-fidelity data for the development and validation of turbulence models. Non-intrusive, simultaneous particle image velocimetry and laser-induced fluorescence measurements were carried out to acquire instantaneous velocity and concentration fields on a vertical section parallel to the axis of a jet in the self-similar region. The refractive index matching method was applied to measure high-resolution buoyant jets with up to 8.6% density difference. These data are free of the typical errors that characterize optical measurements of buoyancy-driven flows (e.g. natural and mixed convection) where the refractive index of the fluid is inhomogeneous throughout the measurement domain. Turbulent statistics and entrainment of buoyant jets in uniform and stratified environments are presented. These data are compared with non-buoyant jets in a uniform environment, as a reference to investigate the effects of buoyancy and stratification on turbulent mixing. The results will be used for the assessment of current turbulence models and as a basis for the development of a new model that captures turbulent mixing.

laser induced fluorescence↗

Revealing the Structure and Dynamics of Self-Generated Electric and Magnetic Fields Near Plasma Stagnation in Laser-Driven Hohlraums

By coupling newly developed triparticle charged particle radiography with radiography reconstruction algorithms and novel reconstruction postprocessing techniques, the spatial structure and time evolution of self-generated electric and magnetic fields in laser-driven vacuum hohlraums have been quantitatively revealed. Through high-fidelity data from a series of experiments, it is shown that late in the hohlraum evolution (after the end of laser drive) these fields are strongly correlated in both space and time, providing evidence that their evolution is primarily dominated by advection with the plasma flow. At these late times, plasma flow velocities inferred from both gross radiography analysis and field reconstructions (and corroborated with Thomson scattering measurements) indicate that the plasma is approaching stagnation near the hohlraum axis. Finally, these experiments provide not only new physical insight into spontaneously generated hohlraum fields, but also provide important spatially and temporally resolved information for future benchmarking of numerical codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bayesian Physics Informed Spatio-Temporal Network for Streamflow Data Imputation

Reliable reconstruction of incomplete streamflow records is critical for improving hydrological forecasting, flood preparedness, and water resource management. However, large observational gaps and uncertainties in governing physical parameters limit the accuracy of traditional statistical and machinelearning imputation frameworks. To address these challenges, we develop a Bayesian Physics-Informed Spatio-Temporal Network (BPI-STNet) that jointly captures spatial and temporal dependencies while enforcing hydrologic consistency through embedded physical constraints. The framework integrates a GraphSAGE-LSTM architecture to model spatial connectivity across gauges and temporal flow dynamics, coupled with a Bayesian update mechanism to estimate uncertain parameters in a simplified water-balance framework. Unlike conventional physics-informed networks that rely on sampling-based posterior estimation, BPI-STNet derives an analytic solution to the inverse problem, allowing closed-form Bayesian updates of uncertain parameters Λ={α,β,k} using Gaussian priors and likelihoods. Applied to daily observations from the Susquehanna River Basin (1980-2022), BPI-STNet achieves substantial improvements over a purely data-driven RGNN baseline, which reduced RMSE by 23 % and MAE by 9 %, and achieving an average NSE values up to 0.96. The results demonstrate that coupling Bayesian inference with physics-informed learning yields physically consistent, uncertainty-aware reconstructions that preserve the temporal persistence and statistical distribution of observed flows. The proposed framework establishes a generalizable paradigm for data-sparse hydrologic systems where both data fidelity and physical interpretability are essential.

Krishnan Kutty Ambika, Anukesh [ORNL] (ORCID:00000↗

Scalable Plug-and-Play ADMM with Convergence Guarantees

Plug-and-play priors (PnP) is a broadly applicable methodology for solving inverse problems by exploiting statistical priors specified as denoisers. Recent work has reported the state-of-the-art performance of PnP algorithms using pre-trained deep neural nets as denoisers in a number of imaging applications. However, current PnP algorithms are impractical in large-scale settings due to their heavy computational and memory requirements. This work addresses this issue by proposing an incremental variant of the widely used PnP-ADMM algorithm, making it scalable to problems involving a large number measurements. Here, we theoretically analyze the convergence of the algorithm under a set of explicit assumptions, extending recent theoretical results in the area. Additionally, we show the effectiveness of our algorithm with nonsmooth data-fidelity terms and deep neural net priors, its fast convergence compared to existing PnP algorithms, and its scalability in terms of speed and memory.

97 MATHEMATICS AND COMPUTING↗

GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation

Purpose: Cone-beam CT (CBCT) plays an important role in image guided radiation therapy (IGRT). However, the large radiation dose from serial CBCT scans in most IGRT procedures raises a clinical concern, especially for pediatric patients who are essentially excluded from receiving IGRT for this reason. The goal of this work is to develop a fast GPU-based algorithm to reconstruct CBCT from undersampled and noisy projection data so as to lower the imaging dose. Methods: The CBCT is reconstructed by minimizing an energy functional consisting of a data fidelity term and a total variation regularization term. The authors developed a GPU-friendly version of the forward-backward splitting algorithm to solve this model. A multigrid technique is also employed. Results: It is found that 20-40 x-ray projections are sufficient to reconstruct images with satisfactory quality for IGRT. The reconstruction time ranges from 77 to 130 s on an NVIDIA Tesla C1060 (NVIDIA, Santa Clara, CA) GPU card, depending on the number of projections used, which is estimated about 100 times faster than similar iterative reconstruction approaches. Moreover, phantom studies indicate that the algorithm enables the CBCT to be reconstructed under a scanning protocol with as low as 0.1 mA s/projection. Comparing with currently widely used full-fan head and neck scanning protocol of {approx}360 projections with 0.4 mA s/projection, it is estimated that an overall 36-72 times dose reduction has been achieved in our fast CBCT reconstruction algorithm. Conclusions: This work indicates that the developed GPU-based CBCT reconstruction algorithm is capable of lowering imaging dose considerably. The high computation efficiency in this algorithm makes the iterative CBCT reconstruction approach applicable in real clinical environments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-dimensional cone beam CT reconstruction and enhancement using a temporal nonlocal means method

Purpose: Four-dimensional cone beam computed tomography (4D-CBCT) has been developed to provide respiratory phase-resolved volumetric imaging in image guided radiation therapy. Conventionally, it is reconstructed by first sorting the x-ray projections into multiple respiratory phase bins according to a breathing signal extracted either from the projection images or some external surrogates, and then reconstructing a 3D CBCT image in each phase bin independently using FDK algorithm. This method requires adequate number of projections for each phase, which can be achieved using a low gantry rotation or multiple gantry rotations. Inadequate number of projections in each phase bin results in low quality 4D-CBCT images with obvious streaking artifacts. 4D-CBCT images at different breathing phases share a lot of redundant information, because they represent the same anatomy captured at slightly different temporal points. Taking this redundancy along the temporal dimension into account can in principle facilitate the reconstruction in the situation of inadequate number of projection images. In this work, the authors propose two novel 4D-CBCT algorithms: an iterative reconstruction algorithm and an enhancement algorithm, utilizing a temporal nonlocal means (TNLM) method. Methods: The authors define a TNLM energy term for a given set of 4D-CBCT images. Minimization of this term favors those 4D-CBCT images such that any anatomical features at one spatial point at one phase can be found in a nearby spatial point at neighboring phases. 4D-CBCT reconstruction is achieved by minimizing a total energy containing a data fidelity term and the TNLM energy term. As for the image enhancement, 4D-CBCT images generated by the FDK algorithm are enhanced by minimizing the TNLM function while keeping the enhanced images close to the FDK results. A forward-backward splitting algorithm and a Gauss-Jacobi iteration method are employed to solve the problems. The algorithms implementation on GPU is designed to avoid redundant and uncoalesced memory access, in order to ensure a high computational efficiency. Our algorithms have been tested on a digital NURBS-based cardiac-torso phantom and a clinical patient case. Results: The reconstruction algorithm and the enhancement algorithm generate visually similar 4D-CBCT images, both better than the FDK results. Quantitative evaluations indicate that, compared with the FDK results, our reconstruction method improves contrast-to-noise-ratio (CNR) by a factor of 2.56-3.13 and our enhancement method increases the CNR by 2.75-3.33 times. The enhancement method also removes over 80% of the streak artifacts from the FDK results. The total computation time is 509-683 s for the reconstruction algorithm and 524-540 s for the enhancement algorithm on an NVIDIA Tesla C1060 GPU card. Conclusions: By innovatively taking the temporal redundancy among 4D-CBCT images into consideration, the proposed algorithms can produce high quality 4D-CBCT images with much less streak artifacts than the FDK results, in the situation of inadequate number of projections.

60 APPLIED LIFE SCIENCES↗

A digitally reconstructed radiograph algorithm calculated from first principles

Purpose: To develop an algorithm for computing realistic digitally reconstructed radiographs (DRRs) that match real cone-beam CT (CBCT) projections with no artificial adjustments. Methods: The authors used measured attenuation data from cone-beam CT projection radiographs of different materials to obtain a function to convert CT number to linear attenuation coefficient (LAC). The effects of scatter, beam hardening, and veiling glare were first removed from the attenuation data. Using this conversion function the authors calculated the line integral of LAC through a CT along rays connecting the radiation source and detector pixels with a ray-tracing algorithm, producing raw DRRs. The effects of scatter, beam hardening, and veiling glare were then included in the DRRs through postprocessing. Results: The authors compared actual CBCT projections to DRRs produced with all corrections (scatter, beam hardening, and veiling glare) and to uncorrected DRRs. Algorithm accuracy was assessed through visual comparison of projections and DRRs, pixel intensity comparisons, intensity histogram comparisons, and correlation plots of DRR-to-projection pixel intensities. In general, the fully corrected algorithm provided a small but nontrivial improvement in accuracy over the uncorrected algorithm. The authors also investigated both measurement- and computation-based methods for determining the beam hardening correction, and found the computation-based method to be superior, as it accounted for nonuniform bowtie filter thickness. The authors benchmarked the algorithm for speed and found that it produced DRRs in about 0.35 s for full detector and CT resolution at a ray step-size of 0.5 mm. Conclusions: The authors have demonstrated a DRR algorithm calculated from first principles that accounts for scatter, beam hardening, and veiling glare in order to produce accurate DRRs. The algorithm is computationally efficient, making it a good candidate for iterative CT reconstruction techniques that require a data fidelity term based on the matching of DRRs and projections.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization

Purpose: Dual-energy CT (DECT) is being increasingly used for its capability of material decomposition and energy-selective imaging. A generic problem of DECT, however, is that the decomposition process is unstable in the sense that the relative magnitude of decomposed signals is reduced due to signal cancellation while the image noise is accumulating from the two CT images of independent scans. Direct image decomposition, therefore, leads to severe degradation of signal-to-noise ratio on the resultant images. Existing noise suppression techniques are typically implemented in DECT with the procedures of reconstruction and decomposition performed independently, which do not explore the statistical properties of decomposed images during the reconstruction for noise reduction. In this work, the authors propose an iterative approach that combines the reconstruction and the signal decomposition procedures to minimize the DECT image noise without noticeable loss of resolution. Methods: The proposed algorithm is formulated as an optimization problem, which balances the data fidelity and total variation of decomposed images in one framework, and the decomposition step is carried out iteratively together with reconstruction. The noise in the CT images from the proposed algorithm becomes well correlated even though the noise of the raw projections is independent on the two CT scans. Due to this feature, the proposed algorithm avoids noise accumulation during the decomposition process. The authors evaluate the method performance on noise suppression and spatial resolution using phantom studies and compare the algorithm with conventional denoising approaches as well as combined iterative reconstruction methods with different forms of regularization. Results: On the Catphan©600 phantom, the proposed method outperforms the existing denoising methods on preserving spatial resolution at the same level of noise suppression, i.e., a reduction of noise standard deviation by one order of magnitude. This improvement is mainly attributed to the high noise correlation in the CT images reconstructed by the proposed algorithm. Iterative reconstruction using different regularization, including quadratic orq-generalized Gaussian Markov random field regularization, achieves similar noise suppression from high noise correlation. However, the proposed TV regularization obtains a better edge preserving performance. Studies of electron density measurement also show that our method reduces the average estimation error from 9.5% to 7.1%. On the anthropomorphic head phantom, the proposed method suppresses the noise standard deviation of the decomposed images by a factor of ∼14 without blurring the fine structures in the sinus area. Conclusions: The authors propose a practical method for DECT imaging reconstruction, which combines the image reconstruction and material decomposition into one optimization framework. Compared to the existing approaches, our method achieves a superior performance on DECT imaging with respect to decomposition accuracy, noise reduction, and spatial resolution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-56: Scan Angle Reduction for a Limited-Angle Intrafraction Verification (LIVE) System

Purpose: To develop a novel adaptive reconstruction strategy to further reduce the scanning angle required by the limited-angle intrafraction verification (LIVE) system for intrafraction verification. Methods: LIVE acquires limited angle MV projections from the exit fluence of the arc treatment beam or during gantry rotation between static beams. Orthogonal limited-angle kV projections are also acquired simultaneously to provide additional information. LIVE considers the on-board 4D-CBCT images as a deformation of the prior 4D-CT images, and solves the deformation field based on deformation models and data fidelity constraint. LIVE reaches a checkpoint after a limited-angle scan, and reconstructs 4D-CBCT for intrafraction verification at the checkpoint. In adaptive reconstruction strategy, a larger scanning angle of 30° is used for the first checkpoint, and smaller scanning angles of 15° are used for subsequent checkpoints. The onboard images reconstructed at the previous adjacent checkpoint are used as the prior images for reconstruction at the current checkpoint. As the algorithm only needs to reconstruct the small deformation occurred between adjacent checkpoints, projections from a smaller scan angle provide enough information for the reconstruction. XCAT was used to simulate tumor motion baseline drift of 2mm along sup-inf direction at every subsequent checkpoint, which are 15° apart. Adaptive reconstruction strategy was used to reconstruct the images at each checkpoint using orthogonal 15° kV and MV projections. Results: Results showed that LIVE reconstructed the tumor volumes accurately using orthogonal 15° kV-MV projections. Volume percentage differences (VPDs) were within 5% and center of mass shifts (COMS) were within 1mm for reconstruction at all checkpoints. Conclusion: It's feasible to use an adaptive reconstruction strategy to further reduce the scan angle needed by LIVE to allow faster and more frequent intrafraction verification to minimize the treatment errors in lung cancer treatments. Grant from Varian Medical System.

60 APPLIED LIFE SCIENCES↗

TH-E-17A-06: Anatomical-Adaptive Compressed Sensing (AACS) Reconstruction for Thoracic 4-Dimensional Cone-Beam CT

Purpose: The Feldkamp-Davis-Kress (FDK) algorithm currently used for clinical thoracic 4-dimensional (4D) cone-beam CT (CBCT) reconstruction suffers from noise and streaking artifacts due to projection under-sampling. Compressed sensing theory enables reconstruction of under-sampled datasets via total-variation (TV) minimization, but TV-minimization algorithms such as adaptive-steepest-descent-projection-onto-convex-sets (ASD-POCS) often converge slowly and are prone to over-smoothing anatomical details. These disadvantages can be overcome by incorporating general anatomical knowledge via anatomy segmentation. Based on this concept, we have developed an anatomical-adaptive compressed sensing (AACS) algorithm for thoracic 4D-CBCT reconstruction. Methods: AACS is based on the ASD-POCS framework, where each iteration consists of a TV-minimization step and a data fidelity constraint step. Prior to every AACS iteration, four major thoracic anatomical structures - soft tissue, lungs, bony anatomy, and pulmonary details - were segmented from the updated solution image. Based on the segmentation, an anatomical-adaptive weighting was applied to the TV-minimization step, so that TV-minimization was enhanced at noisy/streaky regions and suppressed at anatomical structures of interest. The image quality and convergence speed of AACS was compared to conventional ASD-POCS using an XCAT digital phantom and a patient scan. Results: For the XCAT phantom, the AACS image represented the ground truth better than the ASD-POCS image, giving a higher structural similarity index (0.93 vs. 0.84) and lower absolute difference (1.1*10{sup 4} vs. 1.4*10{sup 4}). For the patient case, while both algorithms resulted in much less noise and streaking than FDK, the AACS image showed considerably better contrast and sharpness of the vessels, tumor, and fiducial marker than the ASD-POCS image. In addition, AACS converged over 50% faster than ASD-POCS in both cases. Conclusions: The proposed AACS algorithm was shown to reconstruct thoracic 4D-CBCT images more accurately and with faster convergence compared to ASD-POCS. The superior image quality and rapid convergence makes AACS promising for future clinical use.

60 APPLIED LIFE SCIENCES↗

MO-FG-204-06: A New Algorithm for Gold Nano-Particle Concentration Identification in Dual Energy CT

Purpose: Gold nano-particle (GNP) has recently attracted a lot of attentions due to its potential as an imaging contrast agent and radiotherapy sensitiser. Imaging the GNP at its low contraction is a challenging problem. We propose a new algorithm to improve the identification of GNP based on dual energy CT (DECT). Methods: We consider three base materials: water, bone, and gold. Determining three density images from two images in DECT is an under-determined problem. We propose to solve this problem by exploring image domain sparsity via an optimization approach. The objective function contains four terms. A data-fidelity term ensures the fidelity between the identified material densities and the DECT images, while the other three terms enforces the sparsity in the gradient domain of the three images corresponding to the density of the base materials by using total variation (TV) regularization. A primal-dual algorithm is applied to solve the proposed optimization problem. We have performed simulation studies to test this model. Results: Our digital phantom in the tests contains water, bone regions and gold inserts of different sizes and densities. The gold inserts contain mixed material consisting of water with 1g/cm3 and gold at a certain density. At a low gold density of 0.0008 g/cm3, the insert is hardly visible in DECT images, especially for those with small sizes. Our algorithm is able to decompose the DECT into three density images. Those gold inserts at a low density can be clearly visualized in the density image. Conclusion: We have developed a new algorithm to decompose DECT images into three different material density images, in particular, to retrieve density of gold. Numerical studies showed promising results.

60 APPLIED LIFE SCIENCES↗

WE-FG-207B-05: Iterative Reconstruction Via Prior Image Constrained Total Generalized Variation for Spectral CT

Purpose: To investigate iterative reconstruction via prior image constrained total generalized variation (PICTGV) for spectral computed tomography (CT) using fewer projections while achieving greater image quality. Methods: The proposed PICTGV method is formulated as an optimization problem, which balances the data fidelity and prior image constrained total generalized variation of reconstructed images in one framework. The PICTGV method is based on structure correlations among images in the energy domain and high-quality images to guide the reconstruction of energy-specific images. In PICTGV method, the high-quality image is reconstructed from all detector-collected X-ray signals and is referred as the broad-spectrum image. Distinct from the existing reconstruction methods applied on the images with first order derivative, the higher order derivative of the images is incorporated into the PICTGV method. An alternating optimization algorithm is used to minimize the PICTGV objective function. We evaluate the performance of PICTGV on noise and artifacts suppressing using phantom studies and compare the method with the conventional filtered back-projection method as well as TGV based method without prior image. Results: On the digital phantom, the proposed method outperforms the existing TGV method in terms of the noise reduction, artifacts suppression, and edge detail preservation. Compared to that obtained by the TGV based method without prior image, the relative root mean square error in the images reconstructed by the proposed method is reduced by over 20%. Conclusion: The authors propose an iterative reconstruction via prior image constrained total generalize variation for spectral CT. Also, we have developed an alternating optimization algorithm and numerically demonstrated the merits of our approach. Results show that the proposed PICTGV method outperforms the TGV method for spectral CT.

60 APPLIED LIFE SCIENCES↗

JANUS: Resilient and Adaptive Data Transmission for Enabling Timely and Efficient Cross-Facility Scientific Workflows

In modern science, the growing complexity of large-scale scientific projects has led to an increasing reliance on cross-facility scientific workflows, where resources and expertise from multiple institutions and geographic locations are leveraged to accelerate scientific discovery. These workflows often require transmitting huge amounts of scientific data through wide-area networks. Although high-speed networks like ESnet and transfer services such as Globus have improved data mobility, several challenges remain. The sheer volume of data can overwhelm network bandwidth, widely used transport protocols such as TCP suffer from inefficiencies due to retransmissions triggered by packet loss, and existing fault-tolerance mechanisms like erasure coding introduce substantial overhead. In this paper, we propose Janus, a resilient and adaptable data transmission approach designed for cross-facility scientific workflows. Unlike traditional TCP-based methods, Janus leverages UDP, integrates erasure coding for fault tolerance, and combines it with error-bounded lossy compression to reduce overhead. This novel design allows users to balance data transmission time and accuracy, optimizing transfer performance based on specific scientific requirements. Additionally, Janus dynamically adjusts erasure coding parameters in response to real-time network conditions, ensuring efficient data transfers even in fluctuating environments. We develop optimization models for determining ideal configurations and implement adaptive data transfer protocols to enhance reliability. Through extensive simulations and real-network experiments, we demonstrate that Janus significantly improves transfer efficiency while maintaining data fidelity.

Esaulov, Vladislav [Georgia State University, Atla↗

HydraGNN v4.0

The new version of HydraGNN v4.0 provides additional core capabilities, such as: Inclusion of multi-body atomistic cluster expansion MACE, polarizable atom interaction neural network PAINN, and equivariant principal neighborhood aggregation (PNAEq) among the message passing layers supported -Inclusion of graph transformers to directly model long-range interactions between nodes that are distant in the graph topology Integration of graph transformers with message passing layers by combining the graph embedding generated by the two mechanisms, which allows for an improved expressivity of the HydraGNN architecture Improved re-implementation of multi-task learning (MTL) to allow its use for stabilized training across imbalanced, multi-source, multi-fidelity data Introduction of multi-task parallelism, a newly proposed type of model parallelism specifically for MTL architectures, which allows to dispatch different output decoding heads to different GPU devices Integration of multi-task parallelism with pre-existing distributed data parallelism to enable a 2D parallelization for distributed training Improved portability of the distributed training across Intel GPUs, which has been testes on ALCF exascale supercomputer Aurora Inclusion of 2-level fine-grained energy profilers portable across NVIDIA, AMD, and Intel GPUs to monitor the power and energy consumption associated with different functions executed by the HydraGNN code during data pre-load and training Restructuring of previous examples and inclusion of new sets of examples to illustrate the download, preprocess, and training of HydraGNN models on new large-scale open-source datasets for atomistic materials modeling (e.g., Alexandria, Transition1x, OMat24, OMol25)

Lupo Pasini, Massimiliano [Oak Ridge National Labo↗