Search NASA⌕ Search

SEARCH · Search NASA

Results for “data filtration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Wash water reclamation technology for advanced manned spacecraft

The results of an analytical study and assessment of state-of-the-art wash water reclamation technology for advanced manned spacecraft is presented. All non-phase-change unit operations, unit processes, and subsystems currently under development by NASA are considered. Included among these are: filtration, ultrafiltration, carbon adsorption, ion exchange, chemical pretreatment, reverse osmosis, hyperfiltration, and certain urea removal techniques. Performance data are given together with the projected weights and sizes of key components and subsystems. In the final assessment, a simple multifiltration approach consisting of surface-type cartridge filters, carbon adsorption and ion exchange resins receives the highest rating for six-man orbital missions of up to 10 years in duration.

Putnam, D. F.↗

Evaluation of no-MST operations in the SRS ARP for Hanford LAWPS

The Savannah River Site (SRS) Actinide Removal Process has been processing salt waste since 2008. This process includes a filtration step in the 512-S facility. Initial operations included the addition, or strike, of monosodium titanate (MST) to remove soluble actinides and strontium. The added MST and any entrained sludge solids were then separated from the supernate by cross flow filtration. During this time, the filter operations have, on many occasions, been the bottleneck process limiting the rate of salt processing. Recently, 512-S- has started operations utilizing “No-MST” where the MST actinide removal strike was not performed and the supernate was simply pre-filtered prior to Cs removal processing. Direct filtration of decanted tank supernate, as demonstrated in 512-S, is the proposed method of operation for the Hanford Low Activity Waste Pretreatment System (LAWPS) facility. Processing decanted supernate without MST solids has been demonstrated for cross flow filtration to provide a significant improvement in production with the SRS Salt Batches 8 and 9 feed chemistries. The average filtration rate for the first 512-S batch processing cycle using No-MST has increased filtrate production by over 35% of the historical average. The increase was sustained for more than double the amount of filtrate batches processed before cleaning of the filter was necessary. While there are differences in the design of the 512-S and Hanford filter systems, the 512-S system should provide a reasonable indication of LAWPS filter performance with similar feed properties. Based on the data from the 512-S facility and with favorable feed properties, the LAWPS filter, as currently sized at over twice the size of the 512-S filter (532 square feet filtration area versus 235 square feet), has the potential to provide sustained filtrate production at the upper range of the planned LAWPS production rate of 17 gpm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lyman alpha emissions in the outer heliosphere

Since 1993, the Ultraviolet Spectrometers aboard both Voyager 1 and 2, were used to study the Ly-alpha glow pattern backscattered by neutral hydrogen atoms at great distance from the sun. When compared to a radiative transfer calculation for an unperturbed interstellar hydrogen flow into the solar system, the data present an excess of intensity seen in the direction of the incoming interstellar wind. An absolute estimate of this Lyman alpha intensity yields 10 to 15 Rayleighs for each spacecraft. We discuss the possibility that this excess is caused by a gradient of hydrogen at large distance from the Sun due to the filtration of interstellar hydrogen when crossing the heliopause. Comparisons with results from the Baranov-Malama model of neutral-plasma coupling at the heliopause are presented. The data yield a range of possible values for the hydrogen gradient which may be used to infer the location of the heliopause.

Quemerais, E.↗

Emerging technologies and approaches to minimize discharges into Lake Michigan, phase 2 module 4 report.

The Great Lakes Initiative (GLI) established the new water quality-based discharge criteria for mercury (Hg), thereby increasing the need for many municipal and industrial wastewater treatment plants in the region to lower the mercury in their effluents. Information on deployable technologies to satisfy these requirements for industrial and municipal dischargers in the Great lakes region is scarce. Therefore, BP funded Purdue University Calumet and Argonne to identify deployable Hg removal technologies to meet the GLI discharge criterion at its Whiting Refinery in Indiana. The joint PUC/Argonne project was divided into 2 phases. Results from Phase I and Phase II Modules 1-3 have been previously reported. This report summarizes the work done in Phase 3 Module 4, which consisted of the pilot scale testing of Hg removal technologies previously selected in Module 3. The pilot testing was an Argonne/PUC jointly directed project that was hosted at and funded by the BP refinery in Whiting, IN. As two organizations were involved in data analysis and interpretation, this report combines two independent sets of evaluations of the testing that was done, prepared respectively by Argonne and Purdue. Each organization retains sole responsibility for its respective analysis conclusions and recommendations. Based on Module 3 bench testing with pre-Effluent To Lake (pre-ETL) and clarifier effluent (CE) samples from the Whiting refinery, three different technologies were chosen for pilot testing: (1) Ultrafiltration (using GE ZeeWeed(reg sign) Technology, 0.04 {mu}m pore size and made up of PVDF) for particulate mercury removal; (2) Adsorption using Mersorb(reg sign) LW, a sulfur-impregnated activated carbon, for dissolved mercury removal if present and (3) The Blue PRO(reg sign) reactive filtration process for both particulate and dissolved (if present) mercury removal. The ultrafiltration and the Blue PRO(reg sign) reactive filtration pilot studies were done simultaneously at the BP Whiting refinery using a slipstream of wastewater taken just prior to the Effluent to lake (pre-ETL) outfall. It was the intention of this pilot testing to demonstrate proof of concept, i.e. can the discharge limits obtained at bench scale be consistently met at the pilot scale. Although Mersorb(reg sign) LW was selected for dissolved mercury removal testing, this technology was not pilot tested because of a lack of dissolved mercury in the test wastewater during the pilot study. The overall objective of this pilot testing was to demonstrate the effectiveness of the tested technologies with continuous and varying feed conditions to meet the GLI criterion (1.3 ppt). Optimization for full-scale design was outside of the scope of this work. In addition to demonstrating whether the Hg criterion can be met, information on residue generation rate, frequency of backwashing and other maintenance issues were collected to better understand the implications for a full-scale system.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Harrell Monosodium Titanate Lot #081811

Monosodium titanate (MST) for use in the Actinide Removal Process (ARP) must be qualified and verified in advance. A single qualification sample for each batch of material is sent to SRNL for analysis, as well as a statistical sampling of verification samples. The Harrell Industries Lot No.081811 qualification and 12 verification samples met all the requirements in the specification, with the possible exception of the geometric standard deviation for particle size. Two subsamples from the qualification sample were analyzed, giving results of 3.82 and 3.28, respectively, for the geometric standard deviation. The specification is {le}3.5. The results for both samples met the remaining particle size specifications, i.e. <10 vol% below 0.8 {mu}m and <1 vol% above 37 {mu}m. Filtration behavior of the current batch is expected to be near that of recent batches. SRNL recommends acceptance of this material. SRNL also recommends performing a statistical review of particle size data for the MST lots from this vendor to assess whether an improved material specification is appropriate.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Occurrence of vancomycin-resistant and -susceptible Enterococcus spp. in reclaimed water used for spray irrigation

Reclaiming municipal wastewater for agricultural, environmental, and industrial purposes is increasing in the United States to combat dwindling freshwater supplies. However, there is a lack of data regarding the microbial quality of reclaimed water. In particular, no previous studies have evaluated the occurrence of vancomycin-resistant enterococci (VRE) in reclaimed water used at spray irrigation sites in the United States. To address this knowledge gap, we investigated the occurrence, concentration, and antimicrobial resistance patterns of VRE and vancomycin-susceptible enterococci at three U.S. spray irrigation sites that use reclaimed water. We collected 48 reclaimed water samples from one Mid-Atlantic and two Midwest spray irrigation sites, as well as their respective wastewater treatment plants, in 2009 and 2010. Samples were analyzed for total enterococci and VRE using standard membrane filtration. Isolates were purified and then confirmed using biochemical tests and PCR. Antimicrobial susceptibility testing was conducted using the Sensititre® microbroth dilution system. Data were analyzed by two-sample proportion tests and one-way analysis of variance. We detected total enterococci and VRE in 71% (34/48) and 4% (2/48) of reclaimed water samples, respectively. Enterococcus faecalis was the most common species identified. At the Mid-Atlantic spray irrigation site, UV radiation decreased total enterococci to undetectable levels; however, subsequent storage in an open-air pond at this site resulted in increased concentrations of enterococci. E. faecalis isolates recovered from the Mid-Atlantic spray irrigation site expressed intrinsic resistance to quinupristin/dalfopristin; however, non-E. faecalis isolates expressed resistance to quinupristin/dalfopristin (52% of isolates), vancomycin (4%), tetracycline (13%), penicillin (4%) and ciprofloxacin (17%). Our findings show that VRE are present in low numbers in reclaimed water at point-of-use at the sampled spray irrigation sites; however, resistance to other antimicrobial classes is more prevalent, particularly among non-E. faecalis isolates. - Highlights: • Enterococci were recovered in 71% of reclaimed water samples. • Vancomycin-resistant enterococci were detected in 4% of reclaimed water samples. • UV radiation at irrigation sites reduced enterococci to undetectable levels. • Storage of reclaimed water in open-air ponds increased levels of enterococci.

54 ENVIRONMENTAL SCIENCES↗

Scatter-Reducing Sounding Filtration Using a Genetic Algorithm and Mean Monthly Standard Deviation

Retrieval algorithms like that used by the Orbiting Carbon Observatory (OCO)-2 mission generate massive quantities of data of varying quality and reliability. A computationally efficient, simple method of labeling problematic datapoints or predicting soundings that will fail is required for basic operation, given that only 6% of the retrieved data may be operationally processed. This method automatically obtains a filter designed to reduce scatter based on a small number of input features. Most machine-learning filter construction algorithms attempt to predict error in the CO2 value. By using a surrogate goal of Mean Monthly STDEV, the goal is to reduce the retrieved CO2 scatter rather than solving the harder problem of reducing CO2 error. This lends itself to improved interpretability and performance. This software reduces the scatter of retrieved CO2 values globally based on a minimum number of input features. It can be used as a prefilter to reduce the number of soundings requested, or as a post-filter to label data quality. The use of the MMS (Mean Monthly Standard deviation) provides a much cleaner, clearer filter than the standard ABS(CO2-truth) metrics previously employed by competitor methods. The software's main strength lies in a clearer (i.e., fewer features required) filter that more efficiently reduces scatter in retrieved CO2 rather than focusing on the more complex (and easily removed) bias issues.

Mandrake, Lukas↗

NSAIDs acutely inhibit TRPC channels in freshly isolated rat glomeruli

Highlights: {yields} We have established a unique approach to search for physiologically relevant mechanisms of TRPC channels in podocytes. {yields} This study describes endogenous TRPC channels in the isolated decapsulated glomeruli preparation. {yields} We report for the first time that NSAIDs inhibit TRPC channels in podocytes. -- Abstract: Using a novel approach for analysis of TRPC channel activity, we report here that NSAIDs are involved into regulation of TRPC channels in the podocytes of the freshly isolated decapsulated glomeruli. Fluorescence and electron microscopy techniques confirmed the integrity of podocytes in the glomeruli. Western blotting showed that TRPC1, 3 and 6 are highly expressed in the glomeruli. Single-channel patch clamp analysis revealed cation currents with distinct TRPC properties. This is the first report describing single TRPC-like currents in glomerular podocytes. Furthermore, our data provide a novel mechanism of NSAIDs regulation of TRPC channels, which might be implicated in maintaining the glomerular filtration barrier.

60 APPLIED LIFE SCIENCES↗

Cooperative Research and Development Agreement between National Energy Technology Laboratory and University of Texas at Austin [Abstract]

The project is a collaboration in the area of water filtration, including for produced waters from subsurface formations. The collaboration will provide University of Texas at Austin access to the J200 LIBS measurement machine, as well as training, facilities, and experts at NETL. NETL will gain access to UTA’s proprietary membrane samples and analysis results. The goal of this project is to determine the effects of ion depth penetration as a function of exposure on the face of the membrane samples and how this exposure may affect overall filtration efficiency. This work could help bring understanding to improved water filtration for contaminated produced waters. During this project the two parties will work together to generate and analyze experimental data from the novel filter samples to develop a journal paper co-authored by both parties.

54 ENVIRONMENTAL SCIENCES↗

Literature Review for Oxalate Oxidation Processes and Plutonium Oxalate Solubility

A literature review of oxalate oxidation processes finds that manganese(II)-catalyzed nitric acid oxidation of oxalate in precipitate filtrate is a viable and well-documented process. The process has been operated on the large scale at Savannah River in the past, including oxidation of 20 tons of oxalic acid in F-Canyon. Research data under a variety of conditions show the process to be robust. This process is recommended for oxalate destruction in H-Canyon in the upcoming program to produce feed for the MOX facility. Prevention of plutonium oxalate precipitation in filtrate can be achieved by concentrated nitric acid/ferric nitrate sequestration of oxalate. Organic complexants do not appear practical to sequester plutonium. Testing is proposed to confirm the literature and calculation findings of this review at projected operating conditions for the upcoming campaign. H Canyon plans to commence conversion of plutonium metal to low-fired plutonium oxide in 2012 for eventual use in the Mixed Oxide Fuel (MOX) Facility. The flowsheet includes sequential operations of metal dissolution, ion exchange, elution, oxalate precipitation, filtration, and calcination. All processes beyond dissolution will occur in HB-Line. The filtration step produces an aqueous filtrate that may have as much as 4 M nitric acid and 0.15 M oxalate. The oxalate needs to be removed from the stream to prevent possible downstream precipitation of residual plutonium when the solution is processed in H Canyon. In addition, sending the oxalate to the waste tank farm is undesirable. This report addresses the processing options for destroying the oxalate in existing H Canyon equipment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Literature review for oxalate oxidation processes and plutonium oxalate solubility

A literature review of oxalate oxidation processes finds that manganese(II)-catalyzed nitric acid oxidation of oxalate in precipitate filtrate is a viable and well-documented process. The process has been operated on the large scale at Savannah River in the past, including oxidation of 20 tons of oxalic acid in F-Canyon. Research data under a variety of conditions show the process to be robust. This process is recommended for oxalate destruction in H-Canyon in the upcoming program to produce feed for the MOX facility. Prevention of plutonium oxalate precipitation in filtrate can be achieved by concentrated nitric acid/ferric nitrate sequestration of oxalate. Organic complexants do not appear practical to sequester plutonium. Testing is proposed to confirm the literature and calculation findings of this review at projected operating conditions for the upcoming campaign.

HB-line↗

SU-E-I-76: Matching Primary and Scattered X-Ray Spectra for Use in Calculating the Diagnostic Radiation Index of Protection

Purpose: Lightweight lead-free or lead-composite protective garments exploit k-edge interactions to attenuate scattered X-rays. Manufacturers specify the protective value of garments in terms of lead equivalence at a single kVp. This is inadequate, as the protection provided by such garments varies with radiation quality in different use conditions. We present a method for matching scattered X-ray spectra to primary X-ray spectra. The resulting primary spectra can be used to measure penetration through protective garments, and such measurements can be weighted and summed to determine a Diagnostic Radiation Index for Protection (DRIP). Methods: Scattered X-ray spectra from fluoroscopic procedures were modeled using Monte Carlo techniques in MCNP-X 2.7. Data on imaging geometry, operator position, patient size, and primary beam spectra were gathered from clinical fluoroscopy procedures. These data were used to generate scattered X-ray spectra resulting from procedural conditions. Technical factors, including kV and added filtration, that yielded primary X-ray spectra that optimally matched the generated scattered X-ray spectra were identified through numerical optimization using a sequential quadratic programming (SQP) algorithm. Results: The primary spectra generated with shape functions matched the relative flux in each bin of the scattered spectra within 5%, and half and quarter-value layers matched within 0.1%. The DRIP for protective garments can be determined by measuring the penetration through protective garments using the matched primary spectra, then calculating a weighted average according to the expected clinical use of the garment. The matched primary spectra are specified in terms of first and second half-value layers in aluminum and acrylic. Conclusion: Lead equivalence is inadequate for completely specifying the protective value of garments. Measuring penetration through a garment using full scatter conditions is very difficult. The primary spectra determined in this work allow for practical primary penetration measurements to be made with equipment readily available to clinical medical physicists.

61 RADIATION PROTECTION AND DOSIMETRY↗

Results from Evaluation of Representative ASME AG-1 Section FK Radial Flow Dimple Pleated HEPA Filters Under Elevated Conditions - 12002

The American Society of Mechanical Engineers (ASME) has recently added Section FK establishing requirements for radial flow HEPA filters to the Code on Nuclear Air and Gas Treatment (AG-1). Section FK filters are expected to be a major element in the HEPA filtration systems across the US Department of Energy (DOE) complex. Radial flow filters have been used in Europe for some time, however a limited amount of performance evaluation data exists with respect to these new AG-1 Section FK units. In consultation with a technical working group, the Institute for Clean Energy Technology (ICET) at Mississippi State University (MSU)has evaluated a series of representative AG-1 Section FK dimple pleated radial flow HEPA filters. The effects of elevated relative humidity and temperature conditions on these filters are particularly concerning. Results from the evaluation of Section FK filters under ambient conditions have been presented at the 2011 waste management conference. Additions to the previous test stand to enable high temperature and high humidity testing, a review of the equipment used, the steps taken to characterize the new additions, and the filter test results are presented in this study. Test filters were evaluated at a volumetric flow rate of 56.6 m{sup 3}/min (2000 cfm) and were challenged under ambient conditions with Alumina, Al(OH){sub 3}, until reaching a differential pressure of 1 kPa (4 in. w.c.), at which time the filters were tested, unchallenged with aerosol, at 54 deg. C (130 deg. F) for approximately 1 hour. At the end of that hour water was sprayed near the heat source to maximize vaporization exposing the filter to an elevated relative humidity up to 95%. Collected data include differential pressure, temperature, relative humidity, and volumetric flow rate versus time. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analyses of HTF-48-12-20/24 (February, 2012) and Archived HTF-E-05-021 Tank 48H Slurry Samples

Personnel characterized a Savannah River National Laboratory (SRNL) archived sample of Tank 48H slurry (HTF-E-05-021) in addition to the composite of samples HTF-48-12-20 and HTF-48-12-24, which were both retrieved in February 2012. The combined February 2012 sample is referred to as HTF-48-12-20/24 in this report. The results from these analyses are compared with Tank 48H samples analyzed in 2003, 2004, and 2005. This work supports the effort to demonstrate copper-catalyzed peroxide oxidation (CCPO) of organic content in this material. The principal findings with respect to the chemical and physical characteristics of the most recent sample are: (1) The measured potassium tetraphenylborate (KTPB) solid concentration is 1.76 wt %; (2) Titanium was in line with 2004 and 2005 slurry measurements at 897 mg/L, it represents 0.1535 ± 0.0012 wt % monosodium titanate (MST); (3) The measured insoluble solids content was 1.467 wt %; (4) The free hydroxide concentration in the Tank 48H filtrate sample (1.02 ± 0.02 M) is close to the Tank 48H limit (1.0 M); (5) Carbonate reported by total inorganic carbon (TIC, 1.39 ± 0.03 M) is more than double the concentrations measured in past (2003-2005) samples; (6) The soluble potassium content (measured at 286 ± 23 mg/L) in the filtrate is in line with all past measurements; and (7) The measured 137 Cs concentration is 7.81E + 08 ± 3.9E + 07 dpm/mL of slurry (1.33 ± 5% Ci/gallon or 3.18E + 05 ± 5% curies of 137 Cs in the tank) in the slurry which is in agreement with the 2005 report of 3.14E + 05 ± 1.5% curies of 137 Cs in the tank. The filtrate 137 Cs concentration is 2.57E + 07 ± 2.6E + 05 dpm/mL. This result is consistent with previous results. Significant analytical data are summarized in Table 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploratory Research: Transport and Transformation of Particulate Organic Matter in Permeable River Sediments

The hyporheic zone (HZ) is the volume of streambed sediments where surface water and groundwater mix. The mixing of ground and surface water geochemical constituents including organic matter and the presence of large microbial populations create an important location for biogeochemical activity. Large and periodic fluctuations in river stage such as those associated with operation of hydroelectric dams, may enhance downstream hyporheic exchange by reversing the direction of flow to/from the stream on a regular basis. Solute transport in hyporheic zones is affected by river regulation; however, little is known about the transport of particulate organic matter (POM) under these conditions. We performed a laboratory experiment to simulate the transport and retention of POM under conditions simulating flow reversal in the hyporheic zone. Here, POM is created by inoculating artificial river water with algae obtained from the Hanford Reach of the Columbia River. POM transport experiments are then conducted in columns packed with sandy sediments; these data are then used to calibrate a model describing fundamental processes controlling its transport in saturated sediments. Models results reveal that filtration, sorption to sediment, and sorption to previously retained POM are important mechanisms of POM retention in sandy, saturated sediments. Additionally, upon flow direction reversal, POM is readily mobilized leading to effluents concentrations above the initial input concentrations. These findings indicate that river stage changes may change POM storage in the hyporheic zone depending on the type and magnitude of flow variation.

54 ENVIRONMENTAL SCIENCES↗

Mathematical modeling of mass transfer during centrifugal filtration of polydisperse suspensions

A mass-transfer equation, the solution of which for given boundary conditions makes it possible to derive in analytical form a relationship between the extraction of the solid phase of a suspension into the centrifuge effluent and the fineness of the particles, is suggested on the basis of a model; this is of particular importance in connection with the development of a new trend in the utilization of filtering centrifuges - concentration of coal slurries by extraction into the centrifuge effluent of the finest particles, the ash content of which is substantially higher than that of particles of the coarser classes. Results are presented for production studies under conditions at an active establishment (the Neryungrinskaya Enrichment Factory); these results confirmed the adequacy of the mathematical model proposed: convergence of computed and experimental data was within the limits of the experimental error (no more than 3%). The model in question can be used to predict results of suspension separation by centrifugal filtration.

01 COAL, LIGNITE, AND PEAT↗

AUTOMATED DEAD-END ULTRAFILTRATION FOR ENHANCED SURVEILLANCE OF LEGIONELLA 2 PNEUMOPHILA AND LEGIONELLA SPP. IN COOLING TOWER WATERS

Detection of Legionella pneumophila in cooling towers and domestic hot water systems involves concentration by centrifugation or membrane filtration prior to inoculation onto growth media or analysis using techniques such as PCR or immunoassays. The Portable Multi-use Automated Concentration System (PMACS) was designed for concentrating microorganisms from large volumes of water in the field and was assessed for enhancing surveillance of L. pneumophila at the Savannah River Site, SC. PMACS samples (100 L; n = 28) were collected from six towers between August 2010 and April 2011 with grab samples (500 ml; n = 56) being collected before and after each PMACS sample. All samples were analyzed for the presence of L. pneumophila by direct fluorescence immunoassay (DFA) using FITC-labeled monoclonal antibodies targeting serogroups 1, 2, 4 and 6. QPCR was utilized for detection of Legionella spp. in the same samples. Counts of L. pneumophila from DFA and of Legionella spp. from qPCR were normalized to cells/L tower water. Concentrations were similar between grab and PMACS samples collected throughout the study by DFA analysis (P = 0.4461; repeated measures ANOVA). The same trend was observed with qPCR. However, PMACS concentration proved advantageous over membrane filtration by providing larger volume, more representative samples of the cooling tower environment, which led to reduced variability among sampling events and increasing the probability of detection of low level targets. These data highlight the utility of the PMACS for enhanced surveillance of L. pneumophila by providing improved sampling of the cooling tower environment.

15 GEOTHERMAL ENERGY↗