Search NASA⌕ Search

SEARCH · Search NASA

Results for “data filtration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Aquifer environment selects for microbial species cohorts in sediment and groundwater

Little is known about the biogeography or stability of sediment-associated microbial community membership because these environments are biologically complex and generally difficult to sample. High-throughput-sequencing methods provide new opportunities to simultaneously genomically sample and track microbial community members across a large number of sampling sites or times, with higher taxonomic resolution than is associated with 16 S ribosomal RNA gene surveys, and without the disadvantages of primer bias and gene copy number uncertainty. We characterized here a sediment community at 5 m depth in an aquifer adjacent to the Colorado River and tracked its most abundant 133 organisms across 36 different sediment and groundwater samples. We sampled sites separated by centimeters, meters and tens of meters, collected on seven occasions over 6 years. Analysis of 1.4 terabase pairs of DNA sequence showed that these 133 organisms were more consistently detected in saturated sediments than in samples from the vadose zone, from distant locations or from groundwater filtrates. Abundance profiles across aquifer locations and from different sampling times identified organism cohorts that comprised subsets of the 133 organisms that were consistently associated. The data suggest that cohorts are partly selected for by shared environmental adaptation.

58 GEOSCIENCES↗

Optimization of Ventilation Energy Demands and Indoor Air Quality in the ZEBRAlliance Homes

High-performance homes require that ventilation energy demands and indoor air quality (IAQ) be simultaneously optimized. In this project, Oak Ridge National Laboratory researchers attempted to bridge these two areas by conducting tests in research houses located in Oak Ridge, TN, that were less than 2 years old, energy-efficient (i.e., expected to consume 50% less energy than a house built per the 2006 IRC), tightly-built, unoccupied, and unfurnished. The team identified air pollutants of concern in the test homes that could generally serve as indicators of IAQ, and conduced field experiments and computer simulations to determine the effectiveness and energy required by various techniques that lessened the concentration of these contaminants. Formaldehyde was selected as the main pollutant of concern from initial air sampling surveys. Field data indicate that concentrations were higher during the summer primarily because emissions from sources rise with increases in temperature. Furthermore, supply ventilation and gas-phase filtration were effective means to reduce formaldehyde concentrations; however, exhaust ventilation had minimal influence on this pollutant. Results from simulations suggest that formaldehyde concentrations obtained while ventilating per ASHRAE 62.2-2010 could be decreased by about 20% from May through September through three strategies: 1) increasing ASHRAE supply ventilation by a factor of two, 2) reducing the thermostat setpoint from 76 to 74°F, or 3) running a gas-phase filtration system while decreasing supply ventilation per ASHRAE by half. In the mixed-humid climate of Oak Ridge, these strategies caused minimal to modest increases in electricity cost of ~$5 to ~$15/month depending on outdoor conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of Ventilation Energy Demands and Indoor Air Quality in High-Performance Homes

High-performance homes require that ventilation energy demands and indoor air quality (IAQ) be simultaneously optimized. We attempted to bridge these two areas by conducting tests in a research house located in Oak Ridge, TN, that was 20 months old, energy-efficient (i.e., expected to consume 50% less energy than a house built per the 2006 IRC), tightly-built (i.e., natural ventilation rate ~0.02 h-1), unoccupied, and unfurnished. We identified air pollutants of concern in the test home that could generally serve as indicators of IAQ, and conduced field experiments and computer simulations to determine the effectiveness and energy required by various techniques that lessened the concentration of these contaminants. Formaldehyde was selected as the main pollutant of concern among the contaminants that were sampled in the initial survey because it was the only compound that showed concentrations that were greater than the recommended exposure levels. Field data indicate that concentrations were higher during the summer primarily because emissions from sources rise with increases in temperature. Furthermore, supply ventilation and gas-phase filtration were effective means to reduce formaldehyde concentrations; however, exhaust ventilation had minimal influence on this pollutant. Results from simulations suggest that formaldehyde concentrations obtained while ventilating per ASHRAE 62.2-2010 could be decreased by about 20% from May through September through three strategies: 1) increasing ASHRAE supply ventilation by a factor of two, 2) reducing the thermostat setpoint from 76 to 74 F, or 3) running a gas-phase filtration system while decreasing supply ventilation per ASHRAE by half. In the mixed-humid climate of Oak Ridge, these strategies caused increases in electricity cost of ~$5 to ~$15/month depending on outdoor conditions.

Hun, Diana E↗

Gas and liquid measurements in air-water bubbly flows

Local measurements of gas- and liquid-phase flow parameters are conducted in an air-water two-phase flow loop. The test section is a vertical pipe with an inner diameter of 50 mm and a height of 3.2 m. The measurements are performed at z/D = 10. The gas-phase measurements are performed using a four-sensor conductivity probe. The data taken from this probe are processed using a signal processing program to yield radial profiles of the void fraction, bubble velocity, and interfacial area concentration. The velocity measurements of the liquid-phase are performed using a state-of-the-art Particle Image Velocimetry (PIV) system. The raw PIV images are acquired using fluorescent particles and an optical filtration device. Image processing is used to remove noise in the raw PIV images. The statistical cross correlation is introduced to determine the axial velocity field and turbulence intensity of the liquid-phase. Measurements are currently being performed at z/D = 32 to provide a more complete data set. These data can be used for computational fluid dynamic model development and validation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reassessment of True Core Collapse Differential Pressure Values for Filter Elements in Safety Critical Environments - 13076

As the areas of application for diverse filter types increases, the mechanics and material sciences associated with the hardware and its relationship with more and more arduous process environments becomes critical to the successful and reliable operation of the filtration equipment. Where the filter is the last safe barrier between the process and the life environment, structural integrity and reliability is paramount in both the validation and the ethical acceptability of the designed equipment. Core collapse is a key factor influencing filter element selection, and is an extremely complex issue with a number of variables and failure mechanisms. It is becoming clear that the theory behind core collapse calculations is not always supported with real tested data. In exploring this issue we have found that the calculation method is not always reflective of the true as tested collapse value, with the calculated values being typically in excess or even an order of magnitude higher than the tested values. The above claim is supported by a case study performed by the author, which disproves most of what was previously understood to be true. This paper also aims to explore the various failure mechanisms of different configurations of filter core, comparing calculated collapse values against real tested values, with a view to understanding a method of calculating their true collapse value. As the technology is advancing, and filter elements are being used in higher temperature, higher pressure, more radioactive and more chemically aggressive environments, confidence in core collapse values and data is crucial. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental and Modeled Assessment of Interventions to Reduce PM2.5 in a Residence during a Wildfire Event

Increasingly large and frequent wildfires affect air quality even indoors by emitting and dispersing fine/ultrafine particulate matter known to pose health risks to residents. With this health threat, we are working to help the building science community develop simplified tools that may be used to estimate impacts to large numbers of homes based on high-level housing characteristics. In addition to reviewing literature sources, we performed an experiment to evaluate interventions to mitigate degraded indoor air quality. We instrumented one residence for one week during an extreme wildfire event in the Pacific Northwest. Outdoor ambient concentrations of PM2.5 reached historic levels, sustained at over 200 μg/m3 for multiple days. Outdoor and indoor PM2.5 were monitored, and data regarding building characteristics, infiltration, and mechanical system operation were gathered to be consistent with the type of information commonly known for residential energy models. Two conditions were studied: a high-capture minimum efficiency rated value (MERV 13) filter integrated into a central forced air (CFA) system, and a CFA with MERV 13 filtration operating with a portable air cleaner (PAC). With intermittent CFA operation and no PAC, indoor corrected concentrations of PM2.5 reached 280 μg/m3, and indoor/outdoor (I/O) ratios reached a mean of 0.55. The measured I/O ratio was reduced to a mean of 0.22 when both intermittent CFA and the PAC were in operation. Data gathered from the test home were used in a modeling exercise to assess expected I/O ratios from both interventions. The mean modeled I/O ratio for the CFA with an MERV 13 filter was 0.48, and 0.28 when the PAC was added. The model overpredicted the MERV 13 performance and underpredicted the CFA with an MERV 13 filter plus a PAC, though both conditions were predicted within 0.15 standard deviation. The results illustrate the ways that models can be used to estimate indoor PM2.5 concentrations in residences during extreme wildfire smoke events.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Data and methods to estimate fetal dose from fluoroscopically guided prophylactic hypogastric artery balloon occlusion

Purpose: To provide data for estimation of fetal radiation dose (D{sub F}) from prophylactic hypogastric artery balloon occlusion (HABO) procedures. Methods: The Monte-Carlo-N-particle (MCNP) transport code and mathematical phantoms representing a pregnant patient at the ninth month of gestation were employed. PA, RAO 20° and LAO 20° fluoroscopy projections of left and right internal iliac arteries were simulated. Projection-specific normalized fetal dose (NFD) data were produced for various beam qualities. The effects of projection angle, x-ray field location relative to the fetus, field size, maternal body size, and fetal size on NFD were investigated. Presented NFD values were compared to corresponding values derived using a physical anthropomorphic phantom simulating pregnancy at the third trimester and thermoluminescence dosimeters. Results: NFD did not considerably vary when projection angle was altered by ±5°, whereas it was found to markedly depend on tube voltage, filtration, x-ray field location and size, and maternal body size. Differences in NFD < 7.5% were observed for naturally expected variations in fetal size. A difference of less than 13.5% was observed between NFD values estimated by MCNP and direct measurements. Conclusions: Data and methods provided allow for reliable estimation of radiation burden to the fetus from HABO.

60 APPLIED LIFE SCIENCES↗

Fission gas bubble identification using MATLAB's image processing toolbox

Automated image processing routines have the potential to aid in the fuel performance evaluation process by eliminating bias in human judgment that may vary from person-to-person or sample-to-sample. This study presents several MATLAB based image analysis routines designed for fission gas void identification in post-irradiation examination of uranium molybdenum (U–Mo) monolithic-type plate fuels. Frequency domain filtration, enlisted as a pre-processing technique, can eliminate artifacts from the image without compromising the critical features of interest. This process is coupled with a bilateral filter, an edge-preserving noise removal technique aimed at preparing the image for optimal segmentation. Adaptive thresholding proved to be the most consistent gray-level feature segmentation technique for U–Mo fuel microstructures. The Sauvola adaptive threshold technique segments the image based on histogram weighting factors in stable contrast regions and local statistics in variable contrast regions. Once all processing is complete, the algorithm outputs the total fission gas void count, the mean void size, and the average porosity. The final results demonstrate an ability to extract fission gas void morphological data faster, more consistently, and at least as accurately as manual segmentation methods. - Highlights: •Automated image processing can aid in the fuel qualification process. •Routines are developed to characterize fission gas bubbles in irradiated U–Mo fuel. •Frequency domain filtration effectively eliminates FIB curtaining artifacts. •Adaptive thresholding proved to be the most accurate segmentation method. •The techniques established are ready to be applied to large scale data extraction testing.

36 MATERIALS SCIENCE↗

Verification of a novel method for tube voltage constancy measurement of orthovoltage x-ray irradiators

Purpose: For orthovoltage x-ray irradiators, the tube voltage is one of the most fundamental system parameters as this directly relates to the dosimetry in radiation biology studies; however, to the best of our knowledge, there is no commercial portable quality assurance (QA) tool to directly test the constancy of the tube voltage greater than 160 kV. The purpose of this study is to establish the Beam Quality Index (BQI), a quantity strongly correlated to the tube voltage, as an alternative parameter for the verification of the tube voltage as part of the QA program of orthovoltage x-ray irradiators. Methods: A multipurpose QA meter and its associated data acquisition software were used to customize the measurement parameters to measure the BQI and collect its time-plot. BQI measurements were performed at 320 kV with four filtration levels on three orthovoltage x-ray irradiators of the same model, one of which had been recently energy-calibrated at the factory. Results: For each of the four filtration levels, the measured BQI values were in good agreement (<5%) between the three irradiators. BQI showed filtration-specificity, possibly due to the difference in beam quality. Conclusions: The BQI has been verified as a feasible alternative for monitoring the constancy of the tube voltage for orthovoltage irradiators. The time-plot of BQI offers information on the behavior of beam energy at different phases of the irradiation time line. In addition, this would provide power supply performance characteristics from initial ramp-up to plateau, and finally, the sharp drop-off at the end of the exposure.

60 APPLIED LIFE SCIENCES↗

Low serum zinc is associated with elevated risk of cadmium nephrotoxicity

Background: Despite animal evidence suggests that zinc modulates cadmium nephrotoxicity, limited human data are available. Objective: To test the hypothesis that low serum zinc concentrations may increase the risk of cadmium-mediated renal dysfunction in humans. Methods: Data from 1545 subjects aged 20 or older in the National Health and Nutrition Examination Survey (NHANES), 2011–2012 were analyzed. Renal function was defined as impaired when estimated glomerular filtration rate (eGFR) fell below 60 ml/min/1.73 m{sup 2} and/or the urinary albumin-to-creatinine ratio surpassed 2.5 in men and 3.5 mg/mmol in women. Results: Within the study cohort, 117 subjects had reduced eGFR and 214 had elevated urinary albumin. After adjusting for potential confounders, subjects with elevated blood cadmium (>0.53 μg/L) were more likely to have a reduced eGFR (odds ratio [OR]=2.21, 95% confidence interval [CI]: 1.09–4.50) and a higher urinary albumin (OR=2.04, 95% CI: 1.13–3.69) than their low cadmium (<0.18 μg/L) peers. In addition, for any given cadmium exposure, low serum zinc is associated with elevated risk of reduced eGFR (OR=3.38, 95% CI: 1.39–8.28). A similar increase in the odds ratio was observed between declining serum zinc and albuminuria but failed to reach statistical significance. Those with lower serum zinc/blood cadmium ratios were likewise at a greater risk of renal dysfunction (p<0.01). Conclusions: This study results suggest that low serum zinc concentrations are associated with an increased risk of cadmium nephrotoxicity. Elevated cadmium exposure is global public health issue and the assessment of zinc nutritional status may be an important covariate in determining its effective renal toxicity. - Highlights: • Blood cadmium was associated with increased risk of nephrotoxicity. • Low serum zinc may exacerbate risk of cadmium-mediated renal dysfunction. • Both zinc deficiency and elevated cadmium exposure are global public health issues. • Nutritional status is important in the assessment of cadmium nephrotoxicity.

54 ENVIRONMENTAL SCIENCES↗

Capture and Decomposition of the Nerve Agent Simulant, DMCP, Using the Zeolitic Imidazolate Framework (ZIF-8)

Understanding mechanisms of decontamination of chemical warfare agents (CWA) is an area of intense research aimed at developing new filtration materials to protect soldiers and civilians in case of state-sponsored or terrorist attack. In this study, we employed complementary structural, chemical, and dynamic probes and in situ data collection, to elucidate the complex chemistry, capture, and decomposition of the CWA simulant, dimethyl chlorophosphonate (DMCP). Our work reveals key details of the reactive adsorption of DMCP and demonstrates the versatility of zeolitic imidazolate framework (ZIF-8) as a plausible material for CWA capture and decomposition. Here, the in situ synchrotron-based powder X-ray diffraction (PXRD) and pair distribution function (PDF) studies, combined with Fourier transform infrared (FT-IR) spectroscopy, X-ray photoelectron spectroscopy (XPS), zinc K-edge X-ray absorption near edge structure (XANES), and Raman spectroscopies, showed that the unique structure, chemical state, and topology of ZIF-8 enable accessibility, adsorption, and hydrolysis of DMCP into the pores and revealed the importance of linker chemistry and Zn 2+ sites for nerve agent decomposition. DMCP decontamination and decomposition product(s) formation were observed by thermogravimetric analysis, FT-IR spectroscopy, and phosphorus (P) K-edge XANES studies. Differential PDF analysis indicated that the average structure of ZIF-8 (at the 30 Å scale) remains unchanged after DMCP dosing and provided information on the dynamics of interactions of DMCP with the ZIF-8 framework. Using in situ PXRD and diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS), we showed that nearly 90% regeneration of the ZIF-8 structure and complete liberation of DMCP and decomposition products occur upon heating.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-J-224: Impact of 4D PET/CT On PERCIST Classification of Lung and Liver Metastases in NSLC and Colorectal Cancer

Purpose: To quantify the impact of 4D PET/CT on PERCIST metrics in lung and liver tumors in NSCLC and colorectal cancer patients. Methods: 32 patients presenting lung or liver tumors of 1–3 cm size affected by respiratory motion were scanned on a GE Discovery 690 PET/CT. The bed position with lesion(s) affected by motion was acquired in a 12 minute PET LIST mode and unlisted into 8 bins with respiratory gating. Three different CT maps were used for attenuation correction: a clinical helical CT (CT-clin), an average CT (CT-ave), and an 8-phase 4D CINE CT (CT-cine). All reconstructions were 3D OSEM, 2 iterations, 24 subsets, 6.4 Gaussian filtration, 192×192 matrix, non-TOF, and non-PSF. Reconstructions using CT-clin and CT-ave used only 3 out of the 12 minutes of the data (clinical protocol); all 12 minutes were used for the CT-cine reconstruction. The percent change of SUVbw-peak and SUVbw-max was calculated between PET-CTclin and PET-CTave. The same percent change was also calculated between PET-CTclin and PET-CTcine in each of the 8 bins and in the average of all bins. A 30% difference from PET-CTclin classified lesions as progressive metabolic disease (PMD) using maximum bin value and the average of eight bin values. Results: 30 lesions in 25 patients were evaluated. Using the bin with maximum SUVbw-peak and SUVbw-max difference, 4 and 13 lesions were classified as PMD, respectively. Using the average bin values for SUVbw-peak and SUVbw-max, 3 and 6 lesions were classified as PMD, respectively. Using PET-CTave values for SUVbw-peak and SUVbw-max, 4 and 3 lesions were classified as PMD, respectively. Conclusion: These results suggest that response evaluation in 4D PET/CT is dependent on SUV measurement (SUVpeak vs. SUVmax), number of bins (single or average), and the CT map used for attenuation correction.

60 APPLIED LIFE SCIENCES↗

Unattended Monitoring of Uranium Holdup with Scintillating Fibers

This work evaluated the use of scintillating fiber (SciFi) radiation sensors as a cost-effective, unattended monitoring technique for uranium holdup accumulation in reprocessing equipment. With ruggedized packaging and an outer diameter of less than 1 cm, scintillating fibers offer deployment flexibility. Additionally, plastic scintillating fibers coupled with standard optical fibers provide an affordable option to monitor locations kilometers away from a localized control room or data acquisition (DAQ) system. These combinations of characteristics along with their relatively low manufacturing costs make scintillating fibers ideal for installation at key measurement points such as pipes, valves, and filtration systems.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

The Function of Two Radical‐SAM Enzymes, HcgA and HcgG, in the Biosynthesis of the [Fe]‐Hydrogenase Cofactor

Abstract In the biosynthesis of the iron‐guanylylpyridinol (FeGP) cofactor, 6‐carboxymethyl‐5‐methyl‐4‐hydroxy‐2‐pyridinol ( 1 ) is 3‐methylated to form 2 , then 4‐guanylylated to form 3 , and converted into the full cofactor. HcgA‐G proteins catalyze the biosynthetic reactions. Herein, we report the function of two radical S ‐adenosyl methionine enzymes, HcgA and HcgG, as uncovered by in vitro complementation experiments and the use of purified enzymes. In vitro biosynthesis using the cell extract from the Methanococcus maripaludis Δ hcgA strain was complemented with HcgA or precursors 1 , 2 or 3 . The results suggested that HcgA catalyzes the biosynthetic reaction that forms 1 . We demonstrated the formation of 1 by HcgA using the 3 kDa cell extract filtrate as the substrate. Biosynthesis in the Δ hcgG system was recovered by HcgG but not by 3 , which indicated that HcgG catalyzes the reactions after the biosynthesis of 3 . The data indicated that HcgG contributes to the formation of CO and completes biosynthesis of the FeGP cofactor.

Arriaza‐Gallardo, Francisco J.↗

The Function of Two Radical‐SAM Enzymes, HcgA and HcgG, in the Biosynthesis of the [Fe]‐Hydrogenase Cofactor

Abstract In the biosynthesis of the iron‐guanylylpyridinol (FeGP) cofactor, 6‐carboxymethyl‐5‐methyl‐4‐hydroxy‐2‐pyridinol ( 1 ) is 3‐methylated to form 2 , then 4‐guanylylated to form 3 , and converted into the full cofactor. HcgA‐G proteins catalyze the biosynthetic reactions. Herein, we report the function of two radical S ‐adenosyl methionine enzymes, HcgA and HcgG, as uncovered by in vitro complementation experiments and the use of purified enzymes. In vitro biosynthesis using the cell extract from the Methanococcus maripaludis Δ hcgA strain was complemented with HcgA or precursors 1 , 2 or 3 . The results suggested that HcgA catalyzes the biosynthetic reaction that forms 1 . We demonstrated the formation of 1 by HcgA using the 3 kDa cell extract filtrate as the substrate. Biosynthesis in the Δ hcgG system was recovered by HcgG but not by 3 , which indicated that HcgG catalyzes the reactions after the biosynthesis of 3 . The data indicated that HcgG contributes to the formation of CO and completes biosynthesis of the FeGP cofactor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Topological Data Analysis for Particulate Gels

Soft gels, formed via the self-assembly of particulate materials, exhibit intricate multiscale structures that provide them with flexibility and resilience when subjected to external stresses. Here, this work combines particle simulations and topological data analysis (TDA) to characterize the complex multiscale structure of soft gels. Our TDA analysis focuses on the use of the Euler characteristic, which is an interpretable and computationally scalable topological descriptor that is combined with filtration operations to obtain information on the geometric (local) and topological (global) structure of soft gels. We reduce the topological information obtained with TDA using principal component analysis (PCA) and show that this provides an informative low-dimensional representation of the gel structure. We use the proposed computational framework to investigate the influence of gel preparation (e.g., quench rate, volume fraction) on soft gel structure and to explore dynamic deformations that emerge under oscillatory shear in various response regimes (linear, nonlinear, and flow). Our analysis provides evidence of the existence of hierarchical structures in soft gels, which are not easily identifiable otherwise. Moreover, our analysis reveals direct correlations between topological changes of the gel structure under deformation and mechanical phenomena distinctive of gel materials, such as stiffening and yielding. In summary, we show that TDA facilitates the mathematical representation, quantification, and analysis of soft gel structures, extending traditional network analysis methods to capture both local and global organization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low thyroid function is not associated with an accelerated deterioration in renal function

Abstract Background Chronic kidney disease (CKD) is frequently accompanied by thyroid hormone dysfunction. It is currently unclear whether these alterations are the cause or consequence of CKD. This study aimed at studying the effect of thyroid hormone alterations on renal function in cross-sectional and longitudinal analyses in individuals from all adult age groups. Methods Individual participant data (IPD) from 16 independent cohorts having measured thyroid stimulating hormone, free thyroxine levels and creatinine levels were included. Thyroid hormone status was defined using clinical cut-off values. Estimated glomerular filtration rates (eGFR) were calculated by means of the four-variable Modification of Diet in Renal Disease (MDRD) formula. For this IPD meta-analysis, eGFR at baseline and eGFR change during follow-up were computed by fitting linear regression models and linear mixed models in each cohort separately. Effect estimates were pooled using random effects models. Results A total of 72 856 individuals from 16 different cohorts were included. At baseline, individuals with overt hypothyroidism (n = 704) and subclinical hypothyroidism (n = 3356) had a average (95% confidence interval) −4.07 (−6.37 to −1.78) and −2.40 (−3.78 to −1.02) mL/min/1.73 m2 lower eGFR as compared with euthyroid subjects (n = 66 542). In (subclinical) hyperthyroid subjects (n = 2254), average eGFR was 3.01 (1.50–4.52) mL/min/1.73 m2 higher. During 329 713 patient years of follow-up, eGFR did not decline more rapidly in individuals with low thyroid function compared with individuals with normal thyroid function. Conclusions Low thyroid function is not associated with a deterioration of renal function. The cross-sectional association may be explained by renal dysfunction causing thyroid hormone alterations.

Meuwese, Christiaan L.↗

Poster - 15: Air kerma rate measurements using a cylindrical free-air ionization chamber on the 05B1-1 beamline at the Canadian Light Source

Purpose: The BioMedical Imaging and Therapy (BMIT) beamlines at the Canadian Light Source offer the opportunity for investigating novel imaging and therapy applications of synchrotron radiation. A necessary component in advancing this research, and in progressing toward clinical applications, is the availability of accurate dosimetry that is traceable to a standards institution. However, dosimetry in this setting is challenging. These beams are typically small, non-uniform, and highly intense. This work describes air kerma rate measurements on a BMIT beamline using a free-air ionization chamber (FAC). Methods: The measurements were taken at the 05B1-1 beamline (∼8 – 100 keV) for several beam qualities with mean energies between 20.0 and 84.0 keV. The Victoreen Model 480 cylindrical FAC, with a specially fabricated 0.52 mm diameter aperture, was used to measure air kerma rates. The required correction factors were determined using a variety of methods: tabulated data, measurements, theoretical calculations and Monte Carlo simulations (EGSnrc user code egs-fac). Results: The experimental air kerma rates measured between 0.270 ± 13.6% and 312 ± 2.7% Gy/min. At lower energies (low filtration), the most impactful correction factors were those for ion recombination and for x-ray attenuation. Conclusions: These measurements marked the first absolute dosimetry performed at the BMIT beamlines. The experimental and Monte Carlo methods developed will allow air kerma rates to be measured under other experimental conditions, provide a benchmark to which other dosimeters will be compared, and provide a reference for imaging and therapy research programs on this beamline.

60 APPLIED LIFE SCIENCES↗