Search NASA⌕ Search

SEARCH · Search NASA

Results for “delay”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A parametrically programmable delay line for microwave photons

Delay lines that store quantum information are crucial for advancing quantum repeaters and hardware efficient quantum computers. Traditionally, they are realized as extended systems that support wave propagation but provide limited control over the propagating fields. Here, we introduce a parametrically addressed delay line for microwave photons that provides a high level of control over the stored pulses. By parametrically driving a three-wave mixing circuit element that is weakly hybridized with an ensemble of resonators, we engineer a spectral response that simulates that of a physical delay line, while providing fast control over the delay line’s properties. We demonstrate this novel degree of control by choosing which photon echo to emit, translating pulses in time, and even swapping two pulses, all with pulse energies on the order of a single photon. We also measure the noise added from our parametric interactions and find it is much less than one photon.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Attosecond time delays in the body frame for photodetachment from molecular anions

Attosecond time delays in molecular photoionization at low energies are dominated by the contribution of the Coulomb phase, which diverges as the energy of the photoelectron decreases towards zero. With calculations on core-electron ejection from CN – and C 2 – we demonstrate that in photodetachment of molecular anions the absence of the long-range Coulomb interaction in the final state can reveal the delays of narrow low-energy shape resonances that do not generally occur in photoionization. Delays of several femtoseconds can be associated with such resonances. Finally, the angular dependence of photodetachment time delays in the body frame is highly sensitive to short-range anisotropies in the electron-molecule interaction as well as to the initial state.

74 ATOMIC AND MOLECULAR PHYSICS↗

Decay studies of the 𝛽-delayed neutron emitters 87 Br and 88 Br measured by means of the Modular Total Absorption Spectrometer at ORNL HRIBF

The β decays of 87 Br, 88 Br, and 87 Kr were measured with the Modular Total Absorption Spectrometer (MTAS) at Oak Ridge National Laboratory’s Holifield Radioactive Ion Beam Facility (HRIBF). Both bromine isotopes are β-delayed neutron emitters that have large cumulative fission yields and were identified as top-priority cases for total absorption study by the Nuclear Energy Agency in 2007. Our investigations corroborate that the decay schemes of 87 Br and 88 Br suffer from the so-called pandemonium effect. Unique MTAS properties enable direct neutron measurements. Here, we present MTAS-derived β-delayed neutron spectra, β-delayed neutron emission probabilities of P n ( 87 Br) = 2.36(24)%, and P n ( 88 Br) = 6.4(6)%, and the β-delayed neutron transitions intensity of 4(2)% to the first excited 87 Kr state, populated in the β-neutron decay of 88Br. Incorporating new data into calculations of the electromagnetic decay heat component emitted during thermal neutron fission of 235 U and 239 Pu improves agreement with experimental data up to approximately 80 s after fission. The estimation of the nuclear reactor $\bar{ν}_e$ flux results in changes of up to 1% in the expected $\bar{ν}_e$ interactions with the detector material for 235 U, 238 U, 239Pu, and 241 Pu.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exploring 𝛽 decay and 𝛽-delayed neutron emission in exotic 46,47 Cl isotopes

In this paper, 𝛽 − and 𝛽-delayed neutron decays of 46,47 Cl are reported from an experiment carried out at the National Superconducting Cyclotron Laboratory using the Beta Counting System. The half-lives of both 46 Cl and 47 Cl were extracted. Based on the delayed 𝛾-ray transitions observed, the level structure of 𝑁=28 46 Ar was determined. Completely different sets of excited states above the first 2 + state in 46 Ar were populated in the 46 Cl 𝛽⁢0⁢𝑛 and 47 Cl 𝛽⁢1⁢𝑛 decay channels. Two new 𝛾-ray transitions in 47 Ar were identified from the very weak 47 Cl 𝛽⁢0⁢𝑛 decay. Furthermore, 46 Cl 𝛽⁢1⁢𝑛 and 47 Cl 𝛽⁢2⁢𝑛 were also observed to yield different population patterns for levels in 45 Ar, including states of different parities. Here, the experimental results allow us to address some of the open questions related to the delayed neutron emission process. For isotopes with large neutron excess and high 𝑄 𝛽 values, delayed neutron emission remains an important decay mode and can be utilized as a powerful spectroscopic tool. Experimental results were compared with shell-model calculations using the FSU and 𝑉 MU effective interactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spectrograph stabilization using a single-delay interferometer on the Hale Telescope

We describe a technique for spectrograph stabilization useful when conventional mitigation techniques of vacuum tanks, thermal insulation, and laser frequency comb may be impractical, expensive, heavy, or bulky. This includes spectrographs on airborne platforms or mounted on telescopes where they suffer a changing gravity vector or other drifts. Placing a fixed-delay interferometer in series with a spectrograph forms an externally dispersed interferometer (EDI). This produces a uniform sinusoidal comb multiplying input spectrum, creating (through heterodyning) beats (moiré patterns). In Fourier space for low frequencies up to the comb frequency, the moiré generated signal counter-rotates to ordinary spectra under an unknown disperser wavenumber drift Δx. This generates a large negative feedback signal useful in a conceptual control loop, to converge rapidly to a stable spectrum and yield Δx. A modified EDI data analysis algorithm (“crossfading”) combines frequency-weighted moiré with conventional spectrum to cancel net output spectrum reaction to Δx. Needing only a single-delay, this is a practical improvement over prior crossfading analyses requiring multiple delays. We test crossfading on ThAr data near 4850 cm−1 taken on Hale telescope in an earlier project. In a single pass, we reduce drift 20 times. Using seven iterations, we reduce 0.5 cm−1 (31 km/s Doppler equivalent) drift to 4×10−7 cm−1 (2.5 cm/s). The interferometer delay can wander, because linearity of phase versus wavenumber interpolates science features between bracketing calibrating spectral references. Second, mathematically reversing the heterodyning effect doubles effective spectral resolution without changing disperser slit.

Erskine, David J [Lawrence Livermore National Labo↗

Delayed Neutron Temporal Signatures for Uranium Enrichment Measurement NA-241 SGTech (Final Report)

Nondestructive determination of uranium enrichment is a core capability for nuclear material accounting and control (NMAC) and safeguards verification measurements; however, traditional gamma spectroscopy-based techniques for enrichment measurement rely on significant assumptions of material composition and geometry, precluding their use in scenarios where a heterogeneous spatial distribution of enrichments is encountered. As an alternative, we are developing a technique to use delayed neutron temporal signatures for the measurement of uranium enrichment. Each uranium isotope has unique delayed neutron group yields, resulting in a unique delayed neutron decay time profile which can be analyzed to determine enrichment without the need for calibration sources. As part of this effort, we performed a series of measurement campaigns in which we used an active well coincidence counter (AWCC) retrofitted with commercial D-D and D-T generators to evaluate the operational characteristics of this method in response to a set of uranium enrichment and mass standards, as well as representative diversion scenarios in which either “concealed” enriched uranium is shielded by depleted uranium or declared enriched uranium is “hollowed out” and replaced with a central region of depleted uranium. A standard operating procedure and best practices were compiled to facilitate the use of delayed neutron-based enrichment measurements for international safeguards inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SBASI: Actuated pyrotechnic time delay initiator

A precision pyrotechnic time delay initiator for missile staging was developed and tested. Incorporated in the assembly is a single bridgewire Apollo standard initiator (SBASI) for initiation, a through-bulkhead-initiator to provide isolation of the SBASI output from the delay, the pyrotechnic delay, and an output charge. An attempt was made to control both primary and secondary variables affecting functional performance of the delay initiator. Design and functional limit exploration was performed to establish tolerance levels on manufacturing and assembling operations. The test results demonstrate a 2% coefficient of variation at any one temperature and an overall 2.7% coefficient of variation throughout the temperature range of 30 to 120 F. Tests were conducted at simulated operational altitude from sea level to 200,000 feet.

Salter, S. J.↗

The effect of visual-motion time delays on pilot performance in a pursuit tracking task

A study has been made to determine the effect of visual-motion time delays on pilot performance of a simulated pursuit tracking task. Three interrelated major effects have been identified: task difficulty, motion cues, and time delays. As task difficulty, as determined by airplane handling qualities or target frequency, increases, the amount of acceptable time delay decreases. However, when relatively complete motion cues are included in the simulation, the pilot can maintain his performance for considerably longer time delays. In addition, the number of degrees of freedom of motion employed is a significant factor.

Miller, G. K., Jr.↗

The SAS-3 delayed command system

To meet the requirements arising from the increased complexity of the power, attitude control and telemetry systems, a full redundant high-performance control section with delayed command capability was designed for the Small Astronomy Satellite-3 (SAS-3). The relay command system of SAS-3 is characterized by 56 bystate relay commands, with capability for handling up to 64 commands in future versions. The 'short' data command service of SAS-1 and SAS-2 consisting of shifting 24-bit words to two users was expanded to five users and augmented with a 'long load' data command service (up to 4080 bits) used to program the telemetry system and the delayed command subsystem. The inclusion of a delayed command service ensures a program of up to 30 relay or short data commands to be loaded for execution at designated times. The design and system operation of the SAS-3 command section are analyzed, with special attention given to the delayed command subsystem.

Hoffman, E. J.↗

DSS range delay calibrations: Current performance level

A means for evaluating Deep Space Station (DSS) range delay calibration performance was developed. Inconsistencies frequently noted in these data are resolved. Development of the DSS range delay data base is described. The data base is presented with comments regarding apparent discontinuities. Data regarding the exciter frequency dependence of the delay values are presented. The improvement observed in the consistency of current DSS range delay calibration data over the performance previously observed is noted.

Spradlin, G. L.↗

Flight-test measurement of the noise reduction of a jet transport delayed flap approach procedure

A delayed flap approach procedure was flight tested using the NASA CV-990 airplane to measure and analyze the noise produced beneath the flight path. Three other types of landing approaches were also flight tested to provide a comparison of the noise reduction benefits to the delayed flap approach. The conventional type of approach was used as a baseline to compare the effectiveness of the other approaches. The decelerating approach is a variation of the delayed flap approach. A detailed comparison of the ground perceived noise generated during the approaches is presented. For this comparison, the measured noise data were normalized to compensate for variations in aircraft weight and winds that occurred during the flight tests. The data show that the reduced flap approach offers some noise reduction, while the delayed flap and decelerating approaches offer significant noise reductions over the conventional approach.

Foster, J. D.↗

The effect of visual-motion time-delays on pilot performance in a simulated pursuit tracking task

An experimental study was made to determine the effect on pilot performance of time delays in the visual and motion feedback loops of a simulated pursuit tracking task. Three major interrelated factors were identified: task difficulty either in the form of airplane handling qualities or target frequency, the amount and type of motion cues, and time delay itself. In general, the greater the task difficulty, the smaller the time delay that could exist without degrading pilot performance. Conversely, the greater the motion fidelity, the greater the time delay that could be tolerated. The effect of motion was, however, pilot dependent.

Miller, G. K., Jr.↗

Development and evaluation of a set of group delay standards

A set of cable assemblies serving as group delay standards having nominal delays of 15, 30, and 60 nsec are described. Various types of measurements were performed on the cable standards, including impedance, microwave phase shift, RF pulse burst delay, modulation pulsed delay, and envelope phase shift measurements. The results of these tests are given, and various sources of error are discussed, in particular, dispersion and internal reflections.

Otoshi, T. Y.↗

Stability analysis for linear systems with time delays

Time delays in the mathematical description of a physical system occur whenever the system is affected not only by conditions at the present time, but also by conditions which have occurred in the past. The tau-decomposition method, as refined by Lee and Hsu, is a method for studying the effects of time delay on the stability of retarded dynamical systems. In this paper, the method is extended to examine the stability and relative stability of: (1) retarded systems with many time delays; and (2) a class of neutral systems with one delay. Applications are included which illustrate the power of the technique.

Barker, L. K.↗

Mikhailov Stability Criterion for Time-delayed Systems

The valid and invalid application of the Mikhailov criterion to linear, time-invariant systems with time delays is discussed. The Mikhailov criterion is a graphical procedure which was developed to examine the stability of linear, time-invariant systems with no time delays. Two equivalent formulations of the criterion are discussed. Results indicate that the first formulation remains valid for time-delayed systems of the retared type, with the understanding that the Mikhailov curve need not necessarily always rotate in the counterclockwise direction for a stable system. Erroneous results in the second formulation are formed when there are time delays in the systems.

Barker, L. K.↗

Delay compensation - Its effect in reducing sampling errors in Fourier spectroscopy

An approximate formula is derived for the spectrum ghosts caused by periodic drive speed variations in a Michelson interferometer. The solution represents the case of fringe-controlled sampling and is applicable when the reference fringes are delayed to compensate for the delay introduced by the electrical filter in the signal channel. Numerical results are worked out for several common low-pass filters. It is shown that the maximum relative ghost amplitude over the range of frequencies corresponding to the lower half of the filter band is typically 20 times smaller than the relative zero-to-peak velocity error, when delayed sampling is used. In the lowest quarter of the filter band it is more than 100 times smaller than the relative velocity error. These values are ten and forty times smaller, respectively, than they would be without delay compensation if the filter is a 6-pole Butterworth.

Zachor, A. S.↗

A Summery of an In-flight Evaluation of Control System Pure Time Delays During Landing Using the F-8 DFBW Airplane

An in-flight investigation of the effect of pure time delays on low L/D space shuttle type landing tasks was undertaken. The results indicate that the sensitivity of the pilot ratings to changes in pure time delay in pitch is strongly affected by the task and only slightly affected by changes in control system augmentation mode. Low L/D spot landings from a lateral offset were twice as sensitive to pure time delay as normal low L/D landings. For comparison purposes, formation flying was also investigated, and was found to be less sensitive to time delay than the landing tasks.

Berry, D. T.↗

Variations in propagation delay times for line ten (TV) based time transfers

Variation in the propagation delay for a 30 km TV (Line Ten) radio link was evaluated for a series of 30 independent measurements. Time marks from TV Channel 5 WTTG in Washington, D.C. were simultaneously measured at the Johns Hopkins University Applied Physics Laboratory and at the United States Naval Observatory against each stations' local cesium standard clocks. Differences in the stations' cesium clocks were determined by portable cesium clock transfers. Thirty independent timing determinations were made. The root mean square deviation in the propagation delay calculated from the timing determinations was 11 ns. The variations seen in the propagation delays are believed to be caused by environmental factors and by errors in the portable clock timing measurements. In correlating the propagation delay variations with local weather conditions, only a moderate dependence on air temperature and absolute humidity was found.

Chiu, M. C.↗