Shock induced magnetic effects in fine particle iron dispersions

Magnetic effects associated with shock induced transformation of fcc antiferromagnetic iron precipitates in polycrystalline copper disks at levels up to 5 GPa in weak magnetic fields (H not greater than 0.5 Oe) were investigated. The demagnetization and anisotropy associated with second order transition, the effects of plastic deformation in imparting magnetic anisotropy and magnetic hardening, and the influence of post shock thermal transients on magnetization associated with recovery, recrystallization and grain growth were studied. It was found that on the microsecond time scale of the shock induced first order transformation, the field sense is recorded in the transformed iron particles. For a given particle size the degree of transformation of fcc iron depends on the level of the shock. For a given shock level the resultant magnetic properties depend on the particle size distribution, with maximum effects noted in specimens with 400 to 600 A particles.

Wasilewski, P. J.↗

Lodestone-explanation for magnetic properties and characterization of the source of magnetic hardening

The microstructure of Class I lodestones was investigated by X-ray diffraction and by optical and transmission electron microscopy, and the behavior of lodestone magnetization was studied at temperatures of 4 to 825 K. It was found that intense magnetization is associated with the gamma Fe2O3-Fe3O4 intergrowth. Thermal demagnetization of the lodestone studied was nearly complete at 300 C. The loss of natural remanence was found to be associated with transformation of gamma Fe2O3 to alpha Fe2O3.

Wasilewski, P. J.↗

A review of the NASA/OAST cryogenic coolers technology program

Low and ultra low temperature cryogenic cooler systems for future space missions include mechanical, solid cryogen, gas adsorption, superfluid helium, helium-3, and magnetic (adiabatic demagnetization) coolers. Operating lifetimes required vary from a few weeks for a Shuttle/Spacelab mission to as long as nine years for missions to the outer planets. Temperature requirements vary from tens to tenths of kelvin. At the higher temperature, cooling loads for detectors, instruments and associated shields may be as high as 15 watts. The general requirements for low and ultra low temperature and techniques that can be employed to achieve these temperatures at expected heat loads are discussed. The NASA Centers involved in the R & T efforts and the type of cooler systems on which they are focusing their effort are considered as well as the thrust of R & T effort for each cooler type. Projected missions that will use the technology are identified.

Lundholm, J. G., Jr.↗

On the natural remanent magnetism of certain mare basalts

The natural remanent magnetization (NRM) and magnetic properties of five fine-grain mare basalts were investigated. The NRM of two vitrophyres has a large soft component, and the directional stability during AF demagnetization is poor. The remaining samples have NRM which is too soft to be of thermal origin and yet too hard to be simply isothermal contamination. It is suggested that the NRM of the samples could be shock remanent magnetization.

Fuller, M.↗

Models of an early lunar dynamo

The hypothesis that a dynamo once existed in the moon, and hence was the source of lunar paleomagnetism, is tested using a model for the global thermoremanent magnetization of spherical lithospheres. Various models of an ancient lunar dipole field are used which incorporate intensity variations and reversals, and which are consistent with lunar sample paleointensities. It is found that non-reversing lunar dynamos which have simple exponential decay histories beginning at 4.6 b.y. ago are inconsistent with this limit, unless the moon has been thoroughly demagnetized to a depth of tens of kilometers by impacts or other processes. An early lunar dynamo cannot be excluded by global scalar measurements unless the permanent lunar dipole moment is shown to be significantly less than 10 to the 13th power G/cu cm by future spacecraft measurements, which may be technologically impossible; vector measurements of lunar magnetic anomalies over the whole moon offer a possibility of determining the source of the field which magnetized the lunar crust.

Srnka, L. J.↗

Testing of the permanent magnet material Mn-Al-C for potential use in propulsion motors for electric vehicles

The development of Mn-Al-C permanent magnets is reviewed. The general properties of the material are discussed and put into perspective relative to alnicos and ferrites. The traction motor designer's demands of a permanent magnet for potential use in electric vehicle drives are reviewed. Tests determined magnetic design data and mechanical strength properties. Easy axis hysteresis and demagnetization curves, recoil loops and other minor loop fields were measured over a temperature range from -50 to 150 C. Hysteresis loops were also measured for three orthogonal directions (the one easy and two hard axes of magnetization). Extruded rods of three different diameters were tested. The nonuniformity of properties over the cross section of the 31 mm diameter rod was studied. Mechanical compressive and bending strength at room temperature was determined on individual samples from the 31 mm rod.

Abdelnour, Z.↗

Axial-field permanent magnet motors for electric vehicles

The modelling of an anisotropic alnico magnet for the purpose of field computation involves assigning a value for the material's permeability in the transverse direction. This is generally based upon the preferred direction properties, being all that are easily available. By analyzing the rotation of intrinsic magnetization due to the self demagnetizing field, it is shown that the common assumptions relating the transverse to the preferred direction are not accurate. Transverse magnetization characteristics are needed, and these are given for Alnico 5, 5-7, and 8 magnets, yielding appropriate permeability values.

Campbell, P.↗

Anomalous magnetizations in 3.4 b.y. old Barberton Mountain Land samples

The ratio of natural remanence (NRM) to saturation remanence is exceedingly high for a number of basaltic to ultramafic samples from the 3.4 billion year old Barberton Mountain Land greenstone belt, South Africa. Although conventional paleointensity methods indicate paleofields of several oersteds, demagnetization curves plotted on logarithmic scale clearly show the NRM in these samples to be unlike thermal remanence. It is probable that the observed NRM is a chemical remanence related to the greenschist metamorphic event, and that the intense magnetizations are the result of internally generated, rather than external fields.

Cisowski, S. M.↗

Stable NRM and mineralogy in Allende - Chondrules

The main objective of the present investigation is related to a description of the magnetic and mineralogic contrasts between chondrules which have a natural remanent magnetization (NRM) vector that is ultrastable during alternating field (AF) demagnetization, and those which have unstable NRM vectors when subjected to the same treatment. The results presented in the present investigation together with new magnetic results from Allende listed in a summary provided by Wasilewski (1981) are used as a basis to argue that the stable NRM in Allende was acquired during a sulfidation event. Attention is given to magnetic phases in Allende, experimental results obtained in magnetic studies conducted with 20 chondrules, and a magnetization model for Allende.

Wasilewski, P. J.↗

Bolometer and photosensitive detector systems for IR

In order to achieve the full sensitivity required for future space astronomy applications, IR detector systems will have to be cooled to 0.1 K or less. The feasibility of such cryocooling has been demonstrated for the established laboratory technique of adiabatic demagnetization, and it has been shown that bolometers made from compensated silicon, with ion-implanted contacts, come close to calculated ultimate performance limits. Unlike bolometers, silicon and germanium photoconductors are highly wavelength-dependent. Useful wavelengths are presented for the most promising photodetectors based on these materials. It is noted that, as the relevant microelectronic technology advances, array detectors in the near-IR may be expected to approach the size and performance of large, intrinsic silicon CCD arrays now available for optical wavelengths.

Low, F. J.↗

Motorized Cyrogenic Valve

Remotely-controlled cryogenic valve operates over temperature range from room temperature to 2 K. Valve used in helium dilution refrigerators, cryostats and adiabatic-demagnetization refrigerators.

Salerno, L.↗

Testing of the permanent magnet material Mn-Al-C for potential use in propulsion motors for electric vehicles

The development of Mn-Al-C permanent magnets is reviewed. The general properties of the material are discussed and put into perspective relative to alnicos and ferrites. The commercial material now available is described by the manufacturer's data. The traction motor designer's demands of a permanent magnet for potential use in electric vehicle drives are reviewed. From this, a list of the needed specific information is extracted. A plan for experimental work is made which would generate this information, or verify data supplied by the producer. The results of these measurements are presented in the form of tables and graphs. The tests determined magnetic design data and some mechanical strength properties. Easy axis hysteresis and demagnetization curves, recoil loops and other minor loop fields were measured over a temperature range from -50 C to +150 C. Hysteresis loops were also measured for three orthogonal directions (the easy and 2 hard axes of magnetization).

Abdelnour, Z. A.↗

Sub-Kelvin temperatures in space

It is pointed out that the use of temperatures below 1 K in space would provide a significant improvement in several areas of research. The sensitivity of bolometers, for instance, can be improvead by as much as a factor of 50, if the operating temperature is lowered from 1.5 K to 0.3 K. A decrease in temperature to 0.1 K can provide even an improvement up to three orders of magnitude. Detectors based on the utilization of such improvements could be employed for far-infrared (100-1000 microns) photometry and spectroscopy in the low-background conditions of space. The study of critical phenomena in He-3/He-4 mixtures is also of interest, taking into account investigations at the tricritical point (0.87 K), which represents the junction of a first-order and a second-order transition. Tests in space are needed because gravity-related effects make adequate tests on earth impossible. He-3 refrigeration can be used to attain temperatures below 1 K. Adiabatic demagnetization can produuce temperatures below 0.3 K.

Kittel, P.↗

History, status and future applications of spaceborne cryogenic systems

Cryogenic cooling is employed for an increasing number of space instruments. Cryogenic cooling is needed to provide the required detector response, reduce preamplifier noise, and/or reduce background radiation. Cryogenic cooling is required by instruments employed for applications missions, gamma-ray and X-ray astronomy, cosmic ray measurements, space surveillance, IR astronomy, relativity measurements, superconductivity devices, and basic research experiments. The cooling is provided with the aid of radiant coolers, stored solid cryogen coolers, stored liquid-helium coolers, mechanical coolers, He-3 coolers, adiabatic demagnetization, refrigeration, and higher temperature adsorption and magnetic systems. Radiant coolers will continue to find widespread application for low cooling-load/high-temperature situation. It is pointed out that a long-lifetime closed-cycle, mechanical cooler is one of the most critical space technological needs.

Sherman, A.↗

Integrated optical signal processing with magnetostatic waves

Magneto-optical devices based on Bragg diffraction of light by magnetostatic waves (MSW's) offer the potential of large time-bandwidth optical signal processing at microwave frequencies of 1 to 20 GHz and higher. A thin-film integrated-optical configuration, with the interacting MSW and guided-optical wave both propagating in a common ferrite layer, is necessary to avoid shape-factor demagnetization effects. The underlying theory of the MSW-optical interaction is outlined, including the development of expressions for optical diffraction efficiency as a function of MSW power and other relevant parameters. Bradd diffraction of guided-optical waves by transversely-propagating magnetostatic waves and collinear TE/TM mode conversion included by MSW's have been demonstrated in yttrium iron garnet (YIG) thin films. Diffraction levels as large as 4% (7 mm interaction length) and a modulation dynamic range of approx 30 dB have been observed. Advantages of these MSW-based devices over the analogous acousto-optical devices include: much greater operating frequencies, tunability of the MSW dispersion relation by varying either the RF frequency or the applied bias magnetic field, simple broad-band MSW transducer structures (e.g., a single stripline), and the potential for very high diffraction efficiencies.

Fisher, A. D.↗

He-3 cooling systems for space

The development of a space-compatible He(3) refrigerator would provide a significant improvement in several areas of research in the 0.3 to 1 K temperature range. There are several methods of achieving these temperatures on Earth: He(3) refrigeration, dilution refrigeration, and adiabatic demagnetization refrigeration. The progress of adapting He(3) refrigeration for use in space is described. Various cycles and possible embodiments of He(3) refrigerators are described. Also included is an analysis of the liquid confinement and liquid-vapor phase-separation system. A possible configuration is then analyzed. Finally, the results of ground-based experiments will be discussed.

Kittel, P.↗

Remanent magnetization of a 'paramagnetic' composition in the ilmenite-hematite solid solution stress

In the ilmenite-hematite solid solution series, compositions more ilmenite-rich than Ilm(73)Hem(27) are classically thought to be paramagnetic at room temperature. Ilm(80)Hem(20) samples have nevertheless been synthesized that acquire hard saturation remanent and thermoremanent moments. From analysis of AC demagnetization data, the source of the measured remanence is believed to be a single-domain (SD) like material within the IlM(80)Hem(20) grains themselves. On the basis of transmission electron microscope observations, it is suggested that transformation-induced domain boundaries, which in part are enriched in hematite component relative to the bulk composition of the grains, could act as the magnetic carrier of the SD-like remanence.

Lawson, C. A.↗

Reciprocating Magnetic Refrigerator

Unit cools to 4 K by adiabatic demagnetization. Two porous matrices of paramagnetic material gadolinium/gallium/garnet held in long piston called displacer, machined out of Micarta (phenol formaldehyde polymer). Holes in side of displacer allow heat-exchange fluid to flow to and through matrices within. Piston seals on displacer prevent substantial mixing of fluid in two loops. Magnetic refrigerator provides continuous rather than "one-shot" cooling.

Johnson, D. L.↗