Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection threshold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The interstellar line spectra of zeta Ophiuchi and zeta Persei and their relation to the short wavelength microwave background radiation

Thirty-one high dispersion Coude spectrograms of zeta Ophiuchi and seven of zeta Persei were numerically synthesized to produce high resolution, low noise spectra in the interval 3650 A to 4350 that yield data on atomic and molecular absorption in well-defined regions of the interstellar medium. The detection threshold is improved by as much as a factor 5 over single plates. Several interstellar lines were discovered in the zeta Oph - 15km/sec cloud and the zeta Per + 13 km/sec cloud.

Bortolot, V. J., Jr.↗

Mie scattering of the interplanetary magnetic field by the whole moon

It is known from the Apollo magnetometer experiments that significant electromagnetic induction takes place in the lunar interior. This induction is excited by fluctuations of the interplanetary magnetic field and is detected by the induced fields on the surface of the moon. These results are reviewed briefly and the formal properties of the theory are discussed. It is shown that the mathematical treatment parallels that for classical electromagnetic scattering. Further the wavelength spectrum of the fluctuations of the interplanetary magnetic field include scales consistent with the radius of the moon. The consequence is that the moon is excited in several modes. Quadrupole and possibly octupole magnetic multipoles are found in the data. The electric type radiation corresponding to transverse magnetic excitation appears suppressed and far below the detection threshold of the magnetometers.

Sonett, C. P.↗

Gated high speed optical detector

The design, fabrication, and test of two gated, high speed optical detectors for use in high speed digital laser communication links are discussed. The optical detectors used a dynamic crossed field photomultiplier and electronics including dc bias and RF drive circuits, automatic remote synchronization circuits, automatic gain control circuits, and threshold detection circuits. The equipment is used to detect binary encoded signals from a mode locked neodynium laser.

Green, S. I.↗

Cartographic quality of ERTS-1 images

Analyses of simulated and operational ERTS images have provided initial estimates of resolution, ground resolution, detectability thresholds and other measures of image quality of interest to earth scientists and cartographers. Based on these values, including an approximate ground resolution of 250 meters for both RBV and MSS systems, the ERTS-1 images appear suited to the production and/or revision of planimetric and photo maps of 1:500,000 scale and smaller for which map accuracy standards are compatible with the imaged detail. Thematic mapping, although less constrained by map accuracy standards, will be influenced by measurement thresholds and errors which have yet to be accurately determined for ERTS images. This study also indicates the desirability of establishing a quantitative relationship between image quality values and map products which will permit both engineers and cartographers/earth scientists to contribute to the design requirements of future satellite imaging systems.

Welch, R. I.↗

Tape Cassette Bacteria Detection System

The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

Source record↗

Redundancy management of inertial systems.

The paper reviews developments in failure detection and isolation techniques applicable to gimballed and strapdown systems. It examines basic redundancy management goals of improved reliability, performance and logistic costs, and explores mechanizations available for both input and output data handling. The meaning of redundant system reliability in terms of available coverage, system MTBF, and mission time is presented and the practical hardware performance limitations of failure detection and isolation techniques are explored. Simulation results are presented illustrating implementation coverages attainable considering IMU performance models and mission detection threshold requirements. The implications of a complete GN&C redundancy management method on inertial techniques are also explored.

Mckern, R. A.↗

Preliminary results on the atmospheres of Io and Jupiter from the Pioneer 10 S-band occultation experiment

The preliminary analysis of data from the Pioneer 10 S-band radio occultation experiment has revealed the presence of an ionosphere on the Jovian satellite Io having an electron density peak of about 60,000 electrons per cubic centimeter at an altitude of approximately 60 to 140 kilometers. This suggests the presence of an atmosphere having a surface number density of about 10 billion to one trillion per cubic centimeter, corresponding to an atmospheric surface pressure of between .1 and 10 nanobar, at or below the detection threshold of the Beta Scorpii stellar occultation. A measurement of the atmosphere of Jupiter was obtained down to the level of about 80 millibars, indicating a large temperature increase at about the 20 millibar level, which cannot be explained by the absorption of solar radiation by methane alone and can possibly be due to absorption by particulate matter.

Kliore, A.↗

A search for posteclipse brightening of Io in 1973. I

Eight eclipse reappearances of the innermost Galilean satellite, Io, were observed during the fall of 1973. The measurements were made using photometers specially designed to cope with the problem of scattered light from Jupiter. Posteclipse brightening of Io was not detected and, if present, was less than our estimated detection threshold of about 0.02 mag.

Millis, R. L.↗

Observations of low energy gamma-ray bursts with SAS-2

The present paper reports on the low-energy gamma-ray bursts observed by the plastic scintillator anticoincidence dome of the Small Astronomy Satellite-2 (SAS-2) gamma-ray telescope. SAS-2 detected two events observed by other satellites and discovered one which was subsequently confirmed by other satellite observations. Two events seen by other satellites were not detected by SAS-2, probably due to earth occultation. The event detection threshold for SAS-2 was almost two orders of magnitude lower than that of the Vela satellites.

Oegelman, H.↗

Capacitively-coupled data receiver clipper stage

Circuit technique compensates for dc offset and asymmetry in dc clipping levels, negates unbalance in input waveform that causes voltage offset at end of data word, blocks any dc component that is generated by asymmetrical operation of clipper, and improves data threshold detection.

Saunders, F. W.↗

A search of the SAS-2 data for pulsed gamma-ray emission from radio pulsars

Data from the SAS-2 high energy gamma ray experiment were examined for pulsed emission from each of 75 radio pulsars which were viewed by the instrument and which have sufficiently well defined period and period derivative information from radio observations to allow for gamma ray periodicity searches. When gamma ray arrival times were converted to pulsar phase using the radio reference timing information, two pulsars, PSR 1747-46 and PSR 1818-04, showed positive effects, each with a probability less than 0.0001 of being a random fluctuation in the data for that pulsar. These are in addition to PSR 0531+21 and PSR 0833-45, previously reported. The results of this study suggest that gamma-ray astronomy has reached the detection threshold for gamma ray pulsars and that work in the near future should give important information on the nature of pulsars.

Ogelman, H. B.↗

A search of the SAS-2 data for pulsed gamma-ray emission from radio pulsars

Data from the SAS-2 high-energy (above 35 MeV) gamma-ray experiment have been examined for pulsed emission from each of 75 radio pulsars which were viewed by the instrument and which have sufficiently well-defined period and period-derivative information from radio observations to allow for gamma-ray periodicity searches. When gamma-ray arrival times were converted to pulsar phase using the radio reference timing information, two pulsars, PSR 1747-46 and PSR 1818-04, showed positive effects, each with a probability of less than 1 part in 10,000 of being a random fluctuation in the data for that pulsar. These are in addition to PSR 0531+21 and PSR 0833-45, previously reported. The results of this study suggest that gamma-ray astronomy has reached the detection threshold for gamma-ray pulsars and that work in the near future should give important new information on the nature of pulsars.

Ogelman, H.↗

The role of fiber optics in mass spectrometer electro-optical ion detection

This paper describes the development of an electro-optical ion detector combining the best features of photographic and electrical ion detection (i.e., wide mass range coverage and low ion detection threshold respectively). A nineteen fold fiber optic image dissector is discussed which reformats the 1 mm x 361 mm mass spectrometer focal plane format to a 19 mm x 19 mm format suitable for vidicon imaging and electronic display of the data.

Norris, D. D.↗

Human Response to Aircraft-Noise-Induced Building Vibration

The effects of noise induced building structure vibration and the rattle of objects on human response to aircraft flyover noise were investigated in a series of studies conducted in both the field and the laboratory. The subjective detection thresholds for vibration and rattle were determined as well as the effect of vibration and rattle upon aircraft noise annoyance.

Cawthorn, J. M.↗

Arrayed receivers for low-rate telemetry

RF carrier array includes one master and slave receiving system to improve overall signal-to-noise ratio. Greater number of slave systems creates additional improvement. Scheme reduces detection threshold of low-rate telemetry signals transmitted from spacecraft, enhancing communications efficiency.

Brockman, M. H.↗

Measurement of suspended solids in lakes and oceans using satellite remote sensing data

Using satellite remote sensing data to measure low concentrations of suspended solids in lakes and oceans requires careful evaluation of background signals from the atmosphere and the water surface. Typical background corrections for Lake Superior are presented and the spectral distribution of the residual radiance from three major categories of turbidity in the lake are determined. The results indicate that for large bodies of water, some general information on atmospheric scattering, water clarity, and the optical properties of suspended solids allows estimates of concentrations of suspended solids to within + or - 0.5 mg/L without using real time ground truth data. Under calibrated conditions the threshold detection level is 0.3 mg/L for the fine particulates dispersed throughout the lake and 1 mg/L for the highly light absorbing effluent from rivers. Comparisons of the minimum reflectance over the open lake areas with reflection from the highly absorbing tannin water from rivers provides a check on the clarity of the atmosphere and the excessive background scatter from the water surface.

Sydor, M.↗

Io control of Jovian radio emission

The possibility of Io controlling Jovian decametric radio emission, particularly in the region below 22 MHz, is discussed. Results of a two-year survey at 26.3 at 26.3 MHz are presented which demonstrate the control of Io over a high-intensity storm component of the radio emission and the independence of a weak radio component from the phase of Io, as was observed at lower frequencies. It is thus hypothesized that Io control is a flux-dependent rather than a frequency-dependent phenomenon, and results of analyses at 18 and 10 MHz which support this hypothesis are presented. The apparent correlation between frequency and Io control is thus shown to result from a selection effect due to the increase of non-Io emission with decreasing frequency and relative antenna detection threshold. This result implies a contiguous Io-controlled source region extending out several Jovian radii along the Io flux tube.

Desch, M. D.↗