Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector R&D”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

WoRDMAp Outbrief: Workshop on Radiation Detection Materials [Slides]

Project Goal: Identify pathway to reliably grow and fabricate high-performance radiation detectors for use in a variety of nonproliferation applications. 1. Create 3 working groups (semiconductors, inorganic and organic scintillators) that bring together international R&D subject-matter experts (national laboratories, industry, and academia), end users, and mission stakeholders 2. Reach expert consensus views regarding current materials related technology gaps and define prioritized R&D directions required to resolve these gaps 3. Envisage the future state of next-generation radiation detection materials and quantify the benefits to nuclear security applications 4. Provide a comprehensive expert report to DNN R&D program office to serve as roadmap with recommendations for future high-impact office investment in radiation-detection materials development

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗

Three-Wave Mixing Kinetic Inductance Traveling-Wave Amplifier with Near-Quantum-Limited Noise Performance

We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave (KIT) amplifier, whose noise performance, measured by a shot-noise tunnel junction (SNTJ), approaches the quantum limit. Biased with a dc current, this amplifier operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone and associated parasitic heating compared to conventional four-wave mixing KIT amplifier devices. It consists of a 50 Ω artificial transmission line whose dispersion allows for a controlled amplification bandwidth. We measure $16.5^{+1}_{–1.3}$ dB of gain across a 2 GHz bandwidth with an input 1 dB compression power of –63 dBm, in qualitative agreement with theory. Using a theoretical framework that accounts for the SNTJ-generated noise entering both the signal and idler ports of the KIT amplifier, we measure the system-added noise of an amplification chain that integrates the KIT amplifier as the first amplifier. This system-added noise, 3.1 ± 0.6 quanta (equivalent to 0.66 ± 0.15 K) between 3.5 and 5.5 GHz, is the one that a device replacing the SNTJ in that chain would see. This KIT amplifier is therefore suitable to read large arrays of microwave kinetic inductance detectors and promising for multiplexed superconducting qubit readout.

42 ENGINEERING↗

Measurement of the e + e - → $ {B}_s^0{\overline{B}}_s^0X $ cross section in the energy range from 10.63 to 11.02 GeV using inclusive $ {D}_s^{+} $ and D 0 production

We report the first measurement of the inclusive e + e - → $b\bar{b}$ → D$^±_s$ X and e + e - → $b\bar{b}$ → D 0 / $\overline{D}^0$ X cross sections in the energy range from 10.63 to 11.02 GeV. Based on these results, we determine σ(e + e - → ${B}_s^0{\overline{B}}_s^0$ X) and σ(e + e - → $B\overline{B}$ X) in the same energy range. We measure the fraction of ${B}_s^0$ events at Υ(10860) to be f s = (${22.0}_{-2.1}^{+2.0}$)%. We determine also the ratio of the ${B}_s^0$ inclusive branching fractions $\mathcal{B}$(${B}_s^0$ → D 0 / $\overline{D}^0$X)/$\mathcal{B}$(${B}_s^0$ → ${D}_s^{\pm }$X) = 0.416 ± 0.018 ± 0.092. The results are obtained using the data collected with the Belle detector at the KEKB asymmetric-energy e + e - collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of multi neutron-to-gamma converter array for measuring time resolved ion temperature of inertial confinement fusion implosions

The ion temperature varying during inertial confinement fusion implosions changes the amount of Doppler broadening of the fusion products, creating subtle changes in the fusion neutron pulse as it moves away from the implosion. A diagnostic design to try to measure these subtle effects is introduced—leveraging the fast time resolution of gas Cherenkov detectors along with a multi-puck array that converts a small amount of the neutron pulse into gamma-rays, one can measure multiple snapshots of the neutron pulse at intermediate distances. Further, precise measurements of the propagating neutron pulse, specifically the variation in the peak location and the skew, could be used to infer time-evolved ion temperature evolved during peak compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2× 6.1× 7.0 m3. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, dE/dx calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Field Design Concept for Second Interaction Region of the Electron-Ion Collider

Efficient realization of the scientific potential of the Electron Ion Collider (EIC) calls for addition of a future second Interaction Region (2nd IR) and a detector in the RHIC IR8 region after the EIC project completion. The second IR and detector are needed to independently cross-check the results of the first detector, and to provide measurements with complementary acceptance. The available space in the existing RHIC IR8 and maximum fields achievable with NbTi superconducting magnet technology impose constraints on the 2nd IR performance. Since commissioning of the 2nd IR is envisioned in a few years after the first IR, such a long time frame allows for more R&D on the Nb₃Sn magnet technology. Thus, it could provide a potential alternative technology choice for the 2nd IR magnets. Presently, we are exploring its potential benefits for the 2nd IR performance, such as improvement of the luminosity and acceptance, and are also assessing the technical risks associated with use of Nb₃Sn magnets. In this paper, we present the current progress of this work.

43 PARTICLE ACCELERATORS↗

Observation of D 2 molecule line emission after massive D 2 injection into runaway electron plateaus in DIII-D

Molecular deuterium line emission is observed in both the visible and ultraviolet (UV) wavelength ranges after massive (> 100 Torr-L) injection of D 2 gas into post-disruption runaway electron (RE) dominated plasmas in the DIII-D tokamak. D 2 UV line emission is found to be the dominant source of radiated power, surpassing D Lyα. Interpretive modeling with a collisional-radiative model (CRM) indicates that D 2 radiation surpasses D radiation because Lyα is strongly trapped, while D 2 UV lines are mostly untrapped. The CRM also indicates that the D 2 line emission is completely dominated by RE impact (rather than thermal electron impact), so the D 2 line emission can serve as a good diagnostic for the spatial localization of REs. Analysis of D 2 visible lines indicates that the D 2 molecules in the plasma are thermally equilibrated with the background plasma, with vibrational, rotational, and kinetic temperatures all near 0.3 eV. D 2 spectroscopy therefore serves as a convenient diagnostic of background plasma temperature. As a result, measurement of D 2 radiated power also appears to serve as a useful diagnostic for constraining neutral transport modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Quantum Nature of the Neutrino

Over the last 100 years we have learned much about the neutrino, but there remain interesting questions about this weakly interacting particle. In particular, at LLNL we are developing an experiment to measure the quantum nature of the neutrino. The 2015 long range plan recom mended tonne-scale neutrinoless double beta decay experiments as the top new project priority and this experiment will target the quantum nature of the neutrino. The LLNL team is motivated and focused on developing the best technology for this experiment which is a liquid xenon time projection chamber called nEXO. Work on nEXO at LLNL started in 2015 with an LDRD and program development funds to de velop the nEXO concept, publish sensitivity predictions, explore alternatives and risks, and to build a credible project team and this effort is on going. In addition, we received research funding from DOE-SC NP and LLNL manages pre-conceptual R&D for the nEXO collaboration a portion of which is executed at LLNL. LLNL has a long history of building large projects, science projects and time projection chambers, but nEXO is in fact the first project of this scale that LLNL is prepared to lead for DOE-SC NP. We have the tools, skills, people and motivation to make nEXO a reality. The current program devel opment dollars are used to prepare the nEXO concept for down select and CD1. These internal LLNL dollars pay for a number of things including project staff to organize the nEXO collaboration for the various reviews, to develop the draft plans and structure to manage the project as well as setting up external advisory committees. The DOE-SC NP base funding is targeted at simulation and analysis of the nEXO concept in preparation for the down select and refinement of the under standing of the detector as well as scientific effort on the large xenon test stand (LXTS) that will burn down one of the largest risks to the nEXO project. Lastly, LLNL is leading the pre-conceptual R&D effort and managing the funds for the nEXO collaboration. LLNL continues to build the best scientific team for nEXO and this year that includes adding Ethan Bernard to lead the efforts on the LXTS. We will also soon add a new postoc, Samuel Hedges, in the fall to the LLNL nEXO team. The effort this year was influenced by the portfolio review, and there were a number of scientific activities led by LLNL to prepare for this review. In addition, we again took a lead role on the new sensitivity paper as well as publishing a paper based analyzing the effects of skin xenon in nEXO. LLNL leads the software and analysis for the project and we continued work in this area as well. High voltage remains a significant risk for the project and we continue to make progress on the LXTS that will mitigate this risk. Lastly we remain active in looking at how to scale the technology to larger scales, and expect to produce a paper on this topic in the near future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Event-by-event direction reconstruction of solar neutrinos in a high light-yield liquid scintillator

The direction of individual B 8 solar neutrinos has been reconstructed using the SNO + liquid scintillator detector. Prompt, directional Cherenkov light was separated from the slower, isotropic scintillation light using time information, and a maximum likelihood method was used to reconstruct the direction of individual scattered electrons. A clear directional signal was observed, correlated with the solar angle. The observation was aided by a period of low primary fluor concentration that resulted in a slower scintillator decay time. This is the first time that event-by-event direction reconstruction in high light-yield liquid scintillator has been demonstrated in a large-scale detector. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g silicon athermal phonon detector with a baseline energy resolution of 4.92 +/- 0.01 eV. This exclusion analysis sets the most stringent dark matter-nucleon cross-section limits for masses from 87--140 MeV/c^2 , with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientic potential of athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

Alkhatib, I↗

Thermodynamic stability of xenon-doped liquid argon detectors

Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we analyze the causes of these instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with $\mathscr{O}$ (1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. In conclusion, this work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Planar laser induced fluorescence mapping of a carbon laser produced plasma

We present measurements of ion velocity distribution profiles obtained by laser induced fluorescence (LIF) on an explosive laser produced plasma. The spatiotemporal evolution of the resulting carbon ion velocity distribution was mapped by scanning through the Doppler-shifted absorption wavelengths using a tunable, diode-pumped laser. The acquisition of these data was facilitated by the high repetition rate capability of the ablation laser (1 Hz), which allowed for the accumulation of thousands of laser shots in short experimental times. By varying the intensity of the LIF beam, we were able to explore the effects of fluorescence power against the laser irradiance in the context of evaluating the saturation vs the non-saturation regime. The small size of the LIF beam led to high spatial resolution of the measurement compared to other ion velocity distribution measurement techniques, while the fast-gate operation mode of the camera detector enabled the measurement of the relevant electron transitions.

Instruments & Instrumentation↗

Detector needs for STS instruments

This white paper contains an analysis of the requirements for the detectors for the initial suite of neutron scattering instruments at the Second Target Station, STS. The detector technologies proposed are compared with the instrument requirements, in-house proficiencies and strengths, and where appropriate, expertise at other facilities. Where relevant, alternative detector options are proposed. The performance gaps between the current state-of-the-art and the required characteristics are identified and projects within the R&D program are proposed in order to close these gaps. Further, neutron beam monitor needs are considered in a similar light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗