Development and validation of a gamma-ray detection response model for neutron-diagnosed subcritical experiments

In a neutron-diagnosed subcritical experiment, a highly sensitive and fast detector is required to accurately determine the true fission γ-ray emission rate from an object composed of special nuclear material under interrogation, in addition to a proper detector response model for use in forward modeling. We present the development of a detector response model that is based in GEANT4 and uses post-processing techniques to include photomultiplier tube time and pulse height response effects. We also define a set of detector performance evaluation metrics that emphasized our experimental objectives. A suite of time and pulse height response measurements for several diverse detector assemblies are described. These assemblies were simulated with this response model and benchmarked against the laboratory measurements. This response model reproduces the pulse height curve shapes and performance hierarchy of the measured detectors well. Additionally, the simulated time response curves exhibit reasonable agreement with counterpart measurements. These measurements and simulation results together suggest that a large volume EJ-299-49 plastic scintillator that is mated to an ultraviolet transmitting plastic light guide and relies on total internal reflection for light transport to the photocathode will provide significantly faster timing, increase pulse height by a factor of 3, and require 25% less γ rays to meet experimental needs, compared to the candidate detector design developed prior to the availability of this response model. Application of this response model and associated performance metrics in the context of large-scale design sensitivity studies is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heated Surface Temperatures Measured by Infrared Detector in a Cascade Environment

Investigators have used infrared devices to accurately measure heated surface temperatures. Several of these applications have been for turbine heat transfer studies involving film cooling and surface roughness, typically, these measurements use an infrared camera positioned externally to the test section. In cascade studies, where several blades are used to ensure periodic flow, adjacent blades block the externally positioned camera's views of the test blade. To obtain a more complete mapping of the surface temperatures, researchers at the NASA Glenn Research Center fabricated a probe with an infrared detector to sense the blade temperatures. The probe size was kept small to minimize the flow disturbance. By traversing and rotating the probe, using the same approach as for total pressure surveys, one can find the blade surface temperatures. Probe mounted infrared detectors are appropriate for measuring surface temperatures where an externally positioned infrared camera is unable to completely view the test object. This probe consists of a 8-mm gallium arsenide (GaAs) lens mounted in front of a mercury-cadmium-zinc-tellurium (HgCdZnTe) detector. This type of photovoltaic detector was chosen because of its high sensitivity to temperature when the detector is uncooled. The particular application is for relatively low surface temperatures, typically ambient to 100 C. This requires a detector sensitive at long wavelengths. The detector is a commercial product enclosed in a 9-mm-diameter package. The GaAs lens material was chosen because of its glass-like hardness and its good long-wavelength transmission characteristics. When assembled, the 6.4-mm probe stem is held in the traversing actuator. Since the entire probe is above the measurement plane, the flow field disturbance in the measurement plane is minimized. This particular probe body is somewhat wider than necessary, because it was designed to have replaceable detectors and lenses. The signal for the detector is fed through the hollow probe body. The detector's signal goes to an externally mounted preamplifier. The detector assembly, along with a preamplifier, is calibrated as a function of the surface temperature for various detector temperatures. The output voltage is a function of both the detector and object temperatures.

Boyle, Robert J.↗

Developing a Novel Platform for Characterizing Thermoelectric Materials for Uncooled Detectors for Land Imaging Applications

Thermal land imaging (imaging at ~8-14 micron optical wavelength) is an essential tool for understanding and managing terrestrial freshwater resources. Current thermal imaging instruments employ low temperature detectors, which require cryocoolers. Consequently, cost-saving reductions in size, weight, and power can be achieved by employing uncooled detectors. One uncooled detector concept, which NASA is pursuing, is a thermopile detector with sub-micron thick doped-Si thermoelectric materials. In order to characterize the thermoelectric properties of the doped silicon, we designed and optimized a novel apparatus. This simple apparatus measures the Seebeck coefficient with thermally isolated stages and LABVIEW automation. We optimized thermal stability using PID tuning and optimized the thermal contact between the thin film samples and stages using electrically conductive springs. Utilizing our apparatus, we measured the Seebeck coefficient of 0.45 micron thick phosphorus-doped single crystal Si samples bonded to alumina substrates. Using these Seebeck coefficient measurements and four-wire electrical resistivity measurements, we determined the relationship between the thermoelectric figure of merit and dopant concentration. These characterization results for doped-Si will guide our thermopile detector design to provide an optimal and competitive detector alternative for future thermal imaging instruments.

Reid, Riley A.↗

Bolometric detector systems for IR and mm-wave space astronomy

Recent developments in bolometric detector systems for millimeter and submillimeter wave space astronomy are described. Current technologies meet all the requirements for the high frequency instrument onboard the cosmic background radiation anisotropy satellite/satellite for the measurement of background anisotropies (COBRAS/SAMBA) platform. It is considered that the technologies that are currently being developed will significantly reduce the effective time constant and/or the cooling requirements of bolometric detectors. These technologies lend themselves to the fabrication of the large format arrays required for the Far Infrared and Submillimeter Space Telescope (FIRST). The scientific goals and detector requirements of the COBRAS/SAMBA platform that will use infrared bolometers are reviewed and the baseline detector system is described, including the feed optics, the infrared filters, the cold amplifiers and the warm readout electronics.

Church, S. E.↗

AstroPix: ATLAS-Inspired Silicon Pixels for Future Space-Based Gamma-ray Telescopes

Space-based gamma-ray telescopes such as the Fermi Large Area Telescope have used single sided silicon strip detectors to measure the position of incident gamma-rays with high resolution. At lower energies, two dimensional position information within a single detector is required. This talk investigates the use of monolithic CMOS active pixel silicon sensors –AstroPix – as a novel technology for use in future gamma-ray telescopes. Based upon detectors designed for use in the ATLAS detector at the LHC, AstroPix has the potential to maintain the high energy and angular resolution required of a medium-energy gamma-ray telescope while reducing noise with the dual detection and readout capabilities of a CMOS chip. The status of AstroPix development and testing, as well as outlook for application in future telescopes such as the proposed medium-energy gamma-ray telescope AMEGO-X, will be presented.

Amanda L. Steinhebel↗

Optical design of the Diffuse Infrared Background Experiment for NASA's Cosmic Background Explorer

The conceptual design for a ten-band absolute filter photometer (the Diffuse Infrared Background Experiment) to operate at 2 K and measure galactic and extragalactic infrared radiation in the 1 to 300-micron range and polarization in the 1 to 3.5-micron range is presented, as part of the NASA Cosmic Background Explorer. The telescope optical design, a Gregorian design incorporating bafffles and shades to provide high stray-light rejection, is described. Pupil nonuniformity in the detector-assembly optical design has been limited. It is determined that detector sensitiity requirements can be met, and that the problem of radiation-induced responsivity variations can be solved by minimizing detector-assembly size, providing for in situ thermal annealing, and allowing for frequent detector calibration. Limitations on mirror performance are to be met by fabricating mirrors and structure from the same aluminum 6061 ingot.

Miller, M. S.↗

Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors

Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for “far detectors” of the next generation of neutrino oscillation experiments far exceeds what has been demonstrated so far. Scaling to this larger mass, as well as the requirement for underground construction places a number of additional constraints on the design. A prototype 35-ton cryostat was built at Fermi National Acccelerator Laboratory to test the functionality of the components foreseen to be used in a very large far detector. The Phase I run, completed in early 2014, demonstrated that liquid argon could be maintained at sufficient purity in a membrane cryostat. A time projection chamber was installed for the Phase II run, which collected data in February and March of 2016. The Phase II run was a test of the modular anode plane assemblies with wrapped wires, cold readout electronics, and integrated photon detection systems. While the details of the design do not match exactly those chosen for the DUNE far detector, the 35-ton TPC prototype is a demonstration of the functionality of the basic components. Measurements are performed using the Phase II data to extract signal and noise characteristics and to align the detector components. A measurement of the electron lifetime is presented, and a novel technique for measuring a track's position based on pulse properties is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Planar Particle Imaging Doppler Velocimetry Developed

Two current techniques exist for the measurement of planar, three-component velocity fields. Both techniques require multiple views of the illumination plane in order to extract all three velocity components. Particle image velocimetry (PIV) is a high-resolution, high accuracy, planar velocimetry technique that provides valuable instantaneous velocity information in aeropropulsion test facilities. PIV can provide three-component flow-field measurements using a two-camera, stereo viewing configuration. Doppler global velocimetry (DGV) is another planar velocimetry technique that can provide three component flow-field measurements; however, it requires three detector systems that must be located at oblique angles from the measurement plane. The three-dimensional configurations of either technique require multiple (DGV) or at least large (stereo PIV) optical access ports in the facility in which the measurements are being conducted. Optical access is extremely limited in aeropropulsion test facilities. In many cases, only one optical access port is available. A hybrid measurement technique has been developed at the NASA Glenn Research Center, planar particle image and Doppler velocimetry (PPIDV), which combines elements from both the PIV and DGV techniques into a single detection system that can measure all three components of velocity across a planar region of a flow field through a single optical access port. In the standard PIV technique, a pulsed laser is used to illuminate the flow field at two closely spaced instances in time, which are recorded on a "frame-straddling" camera, yielding a pair of single-exposure image frames. The PIV camera is oriented perpendicular to the light sheet, and the processed PIV data yield the two-component velocity field in the plane of the light sheet. In the standard DGV technique, an injection-seeded Nd:YAG pulsed laser light sheet illuminates the seeded flow field, and three receiver systems are used to measure three components of velocity. The receiver systems are oriented at oblique angles to the light sheet in order to accurately resolve the three-component velocity. Each DGV receiver system contains two cameras, which share a common view of the illuminated flow through a beam-splitting cube. One camera views the illuminated flow directly (reference camera) and the second camera images the illuminated flow through an iodine vapor cell (signal camera). The laser frequency (wavelength) is adjusted so that the Doppler-shifted light from particles in the flow falls on an iodine absorption feature, see the following graph. The iodine vapor cell acts as a frequency-to-velocity filter by modulating the intensity of the transmitted light as a function of the flow velocity (Doppler shift). The ratio of the signal and reference images yields the component of the flow velocity along the bisector of the laser sheet propagation direction and the receiver system observation direction. The hybrid system employs a single-component DGV receiver system configured to simultaneously acquire PIV image data, as shown in the following diagram. The cameras used in the DGV receiver are replaced with PIV frame-straddling cameras, and the receiver system views the illuminated light sheet plane at 90 (as in the standard PIV configuration).

Wernet, Mark P.↗

BESST: A Miniature, Modular Radiometer

A new radiometer assembly has been developed that incorporates modular design principles in order to provide flexibility and versatility. The assembly, shown in Figure 1, is made up of six modules plus a central cubical frame. A small thermal imaging detector is used to determine the temperature of remote objects. To improve the accuracy of the temperature reading, frequent calibration is required. The detector must view known temperature targets before viewing the remote object. Calibration is achieved by using a motorized fold mirror to select the desired scene the detector views. The motor steps the fold mirror through several positions, which allows the detector to view the calibration targets or the remote object. The details, features, and benefits of the radiometer are described in this paper.

Warden, Robert↗

TES Detector Noise Limited Readout Using SQUID Multiplexers

The availability of superconducting Transition Edge Sensors (TES) with large numbers of individual detector pixels requires multiplexers for efficient readout. The use of multiplexers reduces the number of wires needed between the cryogenic electronics and the room temperature electronics and cuts the number of required cryogenic amplifiers. We are using an 8 channel SQUID multiplexer to read out one-dimensional TES arrays which are used for submillimeter astronomical observations. We present results from test measurements which show that the low noise level of the SQUID multiplexers allows accurate measurements of the TES Johnson noise, and that in operation, the readout noise is dominated by the detector noise. Multiplexers for large number of channels require a large bandwidth for the multiplexed readout signal. We discuss the resulting implications for the noise performance of these multiplexers which will be used for the readout of two dimensional TES arrays in next generation instruments.

Staguhn, J. G.↗

A demonstrator for a real-time AI-FPGA-based triggering system for sPHENIX at RHIC

The RHIC interaction rate at sPHENIX will reach around 3 MHz in pp collisions and requires the detector readout to reject events by a factor of over 200 to fit the DAQ bandwidth of 15 kHz. Some critical measurements, such as heavy flavor production in pp collisions, often require the analysis of particles produced at low momentum. This prohibits adopting the traditional approach, where data rates are reduced through triggering on rare high momentum probes. We explore a new approach based on real-time AI technology, adopt an FPGA-based implementation using a custom designed FELIX-712 board with the Xilinx Kintex Ultrascale FPGA, and deploy the system in the detector readout electronics loop for real-time trigger decision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A demonstrator for a real-time AI-FPGA-based triggering system for sPHENIX at RHIC

The RHIC interaction rate at sPHENIX will reach around 3 MHz in pp collisions and requires the detector readout to reject events by a factor of over 200 to fit the DAQ bandwidth of 15 kHz. Some critical measurements, such as heavy flavor production in pp collisions, often require the analysis of particles produced at low momentum. This prohibits adopting the traditional approach, where data rates are reduced through triggering on rare high momentum probes. We explore a new approach based on real-time AI technology, adopt an FPGA-based implementation using a custom designed FELIX-712 board with the Xilinx Kintex Ultrascale FPGA, and deploy the system in the detector readout electronics loop for real-time trigger decision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simons Observatory: Characterization of the Large Aperture Telescope Receiver

The Simons Observatory (SO) is a ground-based cosmic microwave background (CMB) survey experiment that currently consists of three 0.42 m small-aperture telescopes and one 6 m large-aperture telescope (LAT), located at an elevation of 5200 m in the Atacama Desert in Chile. At the LAT’s focal plane, SO will install >62,000 transition-edge sensor detectors across 13 optics tubes (OTs) within the Large Aperture Telescope Receiver (LATR), the largest cryogenic camera ever built to observe the CMB. Furthermore we report on the validation of the LATR in the laboratory and the subsequent dark testing and validation within the LAT. We show that the LATR meets cryogenic, optical, and detector specifications required for high-sensitivity measurements of the CMB. At the time of writing, the LATR is installed in the LAT with six OTs (corresponding to >31,000 detectors), and the LAT mirrors and remaining seven OTs are undergoing development.

Astronomical instrumentation↗

BICEP Array: 150 GHz Detector Module Development

The Background Imaging of Cosmic Extragalactic Polarization (BICEP)/Keck (BK) collaboration is currently leading the quest for the highest-sensitivity measurements of the polarized cosmic microwave background (CMB) anisotropies on a degree scale with a series of cryogenic telescopes, of which BICEP Array (BA) is the latest Stage-3 upgrade with a total of ~ 32,000 detectors. The instrument comprises 4 receivers spanning 30–270 GHz, with the low-frequency 30/40 GHz deployed to the South Pole Station in late 2019. The full complement of receivers is forecast to set the most stringent constraints on the tensor-to-scalar ratio r. Building on these advances, the overarching small-aperture telescope concept is already being used as the reference for further Stage-4 experiment design. This paper describes the development of the BICEP Array 150 GHz detector module and its fabrication requirements, with highlights on the high-density time division multiplexing (TDM) design of the cryogenic circuit boards. The low-impedance wiring required between the detectors and the frst stage of superconducting quantum interference device amplifers is crucial to maintaining a stable bias current on the detectors. Here, a novel multilayer FR4 Printed Circuit Board with superconducting traces, capable of reading out up to 648 detectors, is detailed along with its validation tests. An ultra-high-density TDM detector module concept we developed for a CMB-S4-like experiment that allows up to 1920 detectors to be read out is also presented. TDM has been chosen as the detector readout technology for the Cosmic Microwave Background Stage-4 (CMB-S4) experiment based on its proven low-noise performance, predictable costs, and overall maturity of the architecture. The heritage for TDM is rooted in mm- and sub-mm-wave experiments dating back 20 years and has since evolved to support a multiplexing factor of 64x in Stage-3 experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Prototyping the Light Detection of the DUNE Near Detector

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment with a 70kt liquid argon time projection chamber (LAr TPC) at the Far Detector complex at the Sanford Underground Research Facility (SURF) and a Near Detector (ND) complex planned for the Fermi National Accelerator Laboratory. The ND complex plans for three detector subsystems, including a modular LAr TPC comprised of 35 optically segregated modules. The modular detector design required the development a novel dielectric light readout, the ArCLight technology, which can be operated in a high voltage environment and has a large active surface. A demonstrator of four modular detectors, DUNE ND-LAr 2x2, will operate in 2023 in Fermilab's NuMI beam. After the construction of the modules was completed, they were successfully operated and commissioned in liquid argon using cosmic-ray muons at the University of Bern. This talk will discuss the designs of the light readout systems used in these modules with focus on the construction and commissioning of the ArCLights as well as the performance of the LRS during the tests at Bern.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Temperature control analysis and flight results for the Viking Orbiter 1975 Mars atmospheric water detection instrument

The Mars atmospheric water detector (MAWD) instrument required a temperature of -70 C at the detector. The monochromator housing required +20 C + or - 1 C. This instrument was located on the scan platform, and slewed across two solar panels. The thermal design for the detector was an open flat plate radiator thermally isolated on four 1-in. tubes, with a flexible strap to the detector. MAWD radiator view factors and heat loads from the spacecraft were determined for the Lander on and off, for all angular positions of the scan platform. Subsystem and system tests were performed using the 25-ft diameter solar simulator. In-flight results have shown no anomalies, and no degradation has been observed. Servo-controlled heaters are used to control the temperature.

Kavanagh, H. M.↗

Precision inclusive Higgs physics at e+e- colliders with tracking detectors and without calorimetry

A primary goal of a future e + e - collider program will be the precision measurement of Higgs boson properties. For practical reasons it is of interest to determine the minimal set of detector specifications required to reach this and other scientific goals. Here we investigate the precision obtainable for the e + e - Zh μ + μ - X inclusive cross section and the Higgs boson mass using the di-muon recoil method, considering a detector that has only an inner tracking system within a solenoidal magnetic field, surrounded by many nuclear interaction lengths of absorbing material, and an outer muon identification system. We find that the sensitivity achievable in these measurements with such a tracking detector is only marginally reduced compared to that expected for a general purpose detector with additional electromagnetic and hadronic calorimeter systems. The difference results mainly from multi-photon backgrounds that are not as easily rejected with tracking detectors. We also comment on the prospects for an analogous measurement of the e + e - → Zh → e + e - X inclusive cross section. Finally, we study searches for light scalars utilizing the di-muon recoil method, estimating the projected reach with a tracking or general purpose detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Submillisecond measurements of system optical modulation functions in mosaic focal plane arrays

Measurements of system optical modulation functions (MTF, SWR) may be distorted by time-dependent environmental effects (thermal, vibration, flexure) and by electronics drift. Fast data collection may therefore be advantageous by minimizing drift time. The problem of fast data collection is accentuated when modulation data must be taken on a large number of detectors in a focal plane array. A method has been developed for the generation and storage of knife edge data from focal plane arrays, where data collection time per detector is in the submillisecond range. Once knife edge collects are completed, MTF response is found using conventional convolution techniques. SWR is obtained directly from knife edge response using a computerized simulation algorithm which bypasses use of MTF harmonics. Requirements for detector electronics speed, damping, and dynamic range are considered.

Thurlow, P. E.↗