Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Determination of jet calibration and energy resolution in proton–proton collisions at $\sqrt{s} = 8~\hbox {TeV}$ using the ATLAS detector

The jet energy scale, jet energy resolution, and their systematic uncertainties are measured for jets reconstructed with the ATLAS detector in 2012 using proton–proton data produced at a centre-of-mass energy of 8 TeV with an integrated luminosity of 20fb -1 . Jets are reconstructed from clusters of energy depositions in the ATLAS calorimeters using the anti-k t algorithm. A jet calibration scheme is applied in multiple steps, each addressing specific effects including mitigation of contributions from additional proton–proton collisions, loss of energy in dead material, calorimeter non-compensation, angular biases and other global jet effects. The final calibration step uses several in situ techniques and corrects for residual effects not captured by the initial calibration. Furthermore, these analyses measure both the jet energy scale and resolution by exploiting the transverse momentum balance in γ + jet, Z + jet, dijet, and multijet events. A statistical combination of these measurements is performed. In the central detector region, the derived calibration has a precision better than 1% for jets with transverse momentum 150 GeV < p T < 1500 GeV, and the relative energy resolution is (8.4 ± 0.6)% for p T =100 GeV and (23 ± 2)% for p T =20 GeV. The calibration scheme for jets with radius parameter R = 1.0, for which jets receive a dedicated calibration of the jet mass, is also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mass reconstruction of heavy neutral leptons from stopped mesons

Heavy neutral leptons (HNLs), depending on their mass and mixing, can be efficiently produced in meson decays from the target or absorber in short- to medium-baseline accelerator neutrino experiments, leaving detectable signals through their decays inside the neutrino detectors. We show that the currently running ICARUS experiment at Fermilab can reconstruct the HNL mass and explore new HNL parameter space in the mass range of 70–190 MeV. The mass reconstruction is enabled by two ingredients: (i) simple two-body kinematics of HNL production from stopped kaon decays at the NuMI absorber, followed by HNL decay into a charged-lepton pair and neutrino at the detector, and (ii) high resolution of Liquid Argon Time Projection Chamber (LArTPC) detectors in reconstructing final state particles. Our mass reconstruction method is robust under realistic energy resolution and angular smearing of the charged leptons, and is applicable to any LArTPC detector. We also discuss the synergy between ICARUS and future facilities like DUNE near detector and PIP-II beam dump in probing the HNL parameter space. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of selenium addition to the cadmium-zinc-telluride matrix for producing high energy resolution X-and gamma-ray detectors

Abstract Both material quality and detector performance have been steadily improving over the past few years for the leading room temperature radiation detector material cadmium-zinc-telluride (CdZnTe). However, although tremendous progress being made, CdZnTe still suffers from high concentrations of performance-limiting defects, such as Te inclusions, networks of sub-grain boundaries and compositional inhomogeneity due to the higher segregation coefficient of Zn. Adding as low as 2% (atomic) Se into CdZnTe matrix was found to successfully mitigate many performance-limiting defects and provide improved compositional homogeneity. Here we report record-high performance of Virtual Frisch Grid (VFG) detector fabricated from as-grown Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 ingot grown by the Traveling Heater Method (THM). Benefiting from superior material quality, we achieved superb energy resolution of 0.77% at 662 keV (as-measured without charge-loss correction algorithms) registered at room temperature. The absence of residual thermal stress in the detector was revealed from white beam X-ray topographic images, which was also confirmed by Infra-Red (IR) transmission imaging under cross polarizers. Furthermore, neither sub-grain boundaries nor their networks were observed from the X-ray topographic image. However, large concentrations of extrinsic impurities were revealed in as-grown materials, suggesting a high likelihood for further reduction in the energy resolution after improved purification of the starting material.

36 MATERIALS SCIENCE↗

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors↗

A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector

The dual-axis duo-lateral position-sensitive silicon detector was developed to detect charged particles with high quality position and energy resolution. When these detectors were used with conventional signal processing electronics, an empirically determined correction was used to improve energy resolution. In this work, the waveforms from the detector after preamplification are studied in detail to investigate position information contained in the waveforms. A 7.22 MeV/nucleon alpha particle beam was impinged directly on a masked dual-axis duo-lateral detector. Data obtained using a 228 Th alpha particle source was also used. Here, by studying the waveform characteristics that give rise to the position-dependent distortions, a new summed trigger analysis method has been developed to significantly improve linearity in position reconstruction without sacrificing energy resolution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of defects in melt and solution grown perovskite CsPbBr 3 single crystals

Recently, there has been considerable interest in x-ray and gamma ray detectors with large volume and high energy resolution that operate at room temperature. To improve detector energy resolution, the carrier mobility-lifetime product needs to be increased, and the electronic trap state concentration needs to be minimized. Defect concentrations in the part per billion range can alter the charge transport and carrier recombination lifetime. In this work, thermally stimulated current spectroscopy measurements were systematically carried out in bulk halide perovskite single crystals of CsPbBr 3 over a temperature range of 80–320 K. The origins and trap parameters of CsPbBr 3 crystals from the solution growth and melt growth procedures were determined and compared. Trap concentrations were ranged from 1 × 10 11 to 1 × 10 16 cm –3 . Appreciable detector performance was observed for CsPbBr3 crystals with trap concentrations less than 1 × 10 14 cm –3 . The comparison of spectral responses of crystal samples grown using two different methods shows that, after purification, solution-grown crystals are comparable to melt-grown crystals in terms of low defect concentration and improved detector performance. Finally, for an improved mobility-lifetime product and enhanced spectral response to high energy radiation from fissile materials, trap states in either type of a crystal ingot must be reduced closer to 10 11 cm –3 .

36 MATERIALS SCIENCE↗

Cesium lead bromide semiconductor radiation detectors: crystal growth, detector performance and polarization

Cesium lead bromide (CsPbBr 3 ) is an upcoming semiconductor radiation detector that has the potential to match the detection properties of cadmium zinc telluride (CZT) and thallium bromide (TlBr). In this paper, we report on CsPbBr 3 gamma detectors with an uncorrected energy resolution of 2% at 662 keV with photopeak-to-Compton ratios as high as 14.3 and hole mobility-lifetime products (μτ h ) as high as 1.7 × 10 –2 cm 2 V –1 . Furthermore, we demonstrate that the processes employed for material purification and crystal growth of high-performing devices are scalable, and large (up to 65 mm in diameter) ultrahigh purity CsPbBr 3 crystals have been successfully grown. Furthermore by using optimized growth conditions and detector fabrication processes, we were able to mitigate the polarization problem where it was revealed that the polarization process is highly dependent on the crystal quality and the electric field direction with respect to the orientation of the crystal.

30 DIRECT ENERGY CONVERSION↗

CUORE opens the door to tonne-scale cryogenics experiments

The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution – comparable to semiconductor detectors – and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. In this work, a brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor [Poster]

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed. The wirescanner system in the ATR canal is utilized after every reactor cycle by the ATR Radiation Measurements Laboratory (RML) to assess the activation of cobalt and nickel dosimeter wires during the cycle. These wires become activated through exposure to thermal and fast neutrons respectively during the irradiation cycle and are highly radioactive upon shutdown. It is for this reason that the wirescanner is used in the ATR canal rather than transporting the dosimeters to another facility. A scoping study was performed to develop a base-line design to ensure that existing capabilities could be replaced with a new system. The new hardware will enable automated measuring of several flux monitor holders without necessitating the removal of the flux wires. In this way, flux wire measurements will be performed with minimal dose to the technicians and will not be limited by canal operations as is presently the case. The new control and acquisition software will be based on commercially available and supported systems that have a wide user-base to provide long-term stability. An electronically cooled HPGe detector will be used to provide high-resolution gamma-ray measurements, an improvement from the low-resolution sodium-iodide detector that is presently deployed. The electronic cooler eliminates the need for liquid nitrogen to cool the detector head. A new collimator has been designed to house the new detector and allow for sufficient counting rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Demonstration of <2 ns timing resolution for neutrino interaction in the MicroBooNE detector

The MicroBooNE detector, located in the Booster Neutrino Beamline (BNB) at Fermilab, collected data from 2015 to 2021. MicroBooNE’s Liquid Argon Time Projection Chamber is accompanied by a Photon Detection System consisting of 32 PMTs used to measure the argon scintillation light and determine the timing of the neutrino interactions. This work employs improved analysis techniques combining light signals and reconstructed tracks achieving neutrino interaction timing resolution <2 ns. The result obtained allows MicroBooNE to access the 2 ns neutrino pulse structure of the BNB for the first time. The timing resolution achieved enables significant enhancement of cosmic background rejection for all neutrino analyses. Furthermore, the ns timing resolution opens the door for searching new long-lived-particles (e.g. Heavy Neutral Leptons, Higgs Portal Scalars) in MicroBooNE, as well in future large LArTPC experiments, namely SBN and DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗

Synchrotron-based Characterization Techniques for Radiation Detection Materials and Devices: An Overview

High-performance room-temperature radiation detectors (high energy resolution for spectrometers, high spatial resolution for imaging devices, and low defect-density for high flux applications) are needed for photon energies (>20 keV) that are not well suited for silicon detectors. Applications for such radiation detectors include nonproliferation, synchrotron, medical, astrophysics, and homeland security. Material- and device- characterization to understand and solve the limiting factors of radiation detection materials and devices is a core element of a radiation detector development R&D program. This presentation will give an overview on the two main synchrotron-based characterization techniques that have been employed by the authors in the last ~20 years: (1) White Beam X-ray Diffraction Topography and (2) Micron-scale detector mapping. A perfect (one domain) crystal (radiation detection material) is a requirement to achieve a highperformance radiation detector. White Beam X-ray Diffraction Topography (WBXDT) allows the rapid screening of the crystallinity of the detector material. With WBXDT we can quickly screen CZT and other crystals to make sure they have only one domain, and to see the presence of extended defects and strain fields.

Camarda, Giuseppe S.↗

Performance of CsI:Tl Cyrstal with a Spectrum Matching Photomultiplier Tube

This report documents an effort to improve the energy resolution for a thallium doped cesium iodide (CsI:T1) scintillator paired with a spectrum matching photomultiplier tube (PMT). A comparison of the differences in the pulse height spectra from thallium doped (CsI:T1) and sodium doped (CsI:Na) single crystals with PMTs of different spectrum responses was performed. Results show that energy resolution of the detector only improves 0.5% at room temperature when these scintillators are coupled with a spectrum matching PMT. Based on a spectrum matching PMT, the best results for energy resolution are 7.39% and 7.88% for CsI:T1 and CsI:Na scintillators, respectively. The improvement is primarily attributed to the increase of photon statistics from the increase of photons (N) being detected in the spectrum matching PMT. Other factors, such as optical quantum yield and non-proportionality of the CsI:T1 and CsI:Na crystals, that can affect the energy resolution were also studied and reported. The results indicate that although the use of a spectrum matching PMT enhances the photon statistics, it also exacerbates the nonproportionality response. Consequently, a promised improvement on energy resolution due solely to photon statistics was not fully realized.

36 MATERIALS SCIENCE↗

Surface-Defect-Passivation-Enabled Near-Unity Charge Collection Efficiency in Bromide-Based Perovskite Gamma-Ray Spectrum Devices

Hybrid lead halide perovskites have superior charge transport properties to all-inorganic perovskites, but high-resolution spectroscopic radiation detectors have not been realized. Here we show that surface deep traps severely limit charge collection in formamidinium lead bromide (FAPbBr3) single-crystal devices, despite having a good bulk transport property. Three types of defect on the crystal surface, namely, FA vacancies, uncoordinated lead and Pb-Pb dimers caused by bromide loss, are found to form deep traps, resulting in non-radiative charge recombinations at the metal/perovskite interface. By tailoring the passivation functional groups, we find that ammonium bromide can passivate all these three deep traps on FAPbBr3 surfaces, improving the charge collection efficiency to near unity. The comparable bulk and surface recombination lifetimes indicate that all the surface defects are effectively passivated. Surface passivation also reduces the dark current by 10 times and decreases the dark counts by ~60 times. The energy resolution of the 137Cs spectra acquired using the FAPbBr3 detectors is improved from 5.7% to 1.7% when all the surface defects are passivated without changing the bulk properties, which is the best among solution-grown semiconductor detectors. Surface passivation is stable for more than six months, and FAPbBr3 spectroscopic detectors can operate at unprecedented high temperatures of more than 130 degrees C.

gamma ray↗

Test and characterization of finely segmented pixel CZT detectors for future hard x-ray missions

The NuSTAR (Nuclear Spectroscopic Telescope Array) mission was launched in 2012, and it has successfully deployed the first orbiting telescopes to focus high energy X-ray (3 - 79 keV) light, providing a wealth of new information on high-energy X-rays sources. Follow-up missions, such as the proposed HEX-P, BEST, and FORCE, could perform a deeper black hole census providing a more refined measurement of black hole spins, allowing for greater knowledge about supermassive black holes. Here, these missions are motivated by the recent breakthroughs in the hard X-ray mirror technologies, where mirrors, either made of monolithic silicon segments, or made directly or via replication of shells, demonstrate the feasibility of making hard X-ray mirrors with angular resolutions of 5-10 arc-seconds Half Power Diameter (HPD) compared to the NuSTAR’s 1 arc-minute HPD. Such a high angular resolution requires matched detectors with higher degree of segmentation to fully benefit from the achievable improved spatial resolution. In the above framework, the HEXID ASIC, a novel pixelated front-end suitable for reading out a finely segmented CZT sensor with 150 μm pixel pitch in a hexagonal arrangement has been developed. This readout pixelated chip is capable of processing photon-generated charge packets over a large dynamic range (from 2 keV up to 180 keV), while keeping a low input noise (ENC <20 e - ). In this work, the initial characterization of the ASIC prototype will be presented.

47 OTHER INSTRUMENTATION↗

Radiation effects induced by the energetic protons in 8x8x32 mm3 CdZnTe detectors

We report CdZnTe (CZT) detectors have been used in the past and are being actively considered for future gamma-ray space telescopes. One of the challenges of operating CZT detectors in low Earth orbit is radiation damage caused by energetic protons. Previous studies concluded that fluences of 10 8 -10 9 p/cm 2 are sufficient to cause shifting of peak positions and degradations of energy resolution. Degradation of detectors after proton irradiation has been extensively investigated to determine their radiation resistance limits and performance recovering procedures for their applications in space and nuclear nonproliferation. Here we present the study of radiation effects induced by 100 MeV protons in 3-cm long CdZnTe detectors that we recently proposed for the gamma-ray telescope GECCO. The goal this study is to evaluate the feasibility of using such long CZT detectors in future space missions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗