Search NASA⌕ Search

SEARCH · Search NASA

Results for “device physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Analytical carrier density and quantum capacitance for graphene

A disorder based analytical carrier density for graphene is presented here. The carrier density, a basic property of all semiconductors, is obtained based on exponential distribution describing the potential fluctuations induced by impurities and shows good agreement with numerical results. The quantum capacitance is subsequently derived from the carrier density, with a good agreement with experimental measurements. A method for extracting the gate coupling function is also proposed, which relates the internal surface potential with the external applied gate voltage. The essential properties of graphene device physics, such as the temperature, material disorder, and surface potential dependences, are captured in these analytical equations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photophysics in emerging photovoltaics

Emerging photovoltaic technologies continue to march forward with power conversion efficiencies of lead halide perovskite solar cells (PSCs) nearing 26%, perovskite-Si tandems now exceeding the single junction detailed balance limit of 33%, and organic solar cells (OSCs) showing efficiencies nearing 20%. Yet, some of the photophysics underpinning PSCs and OSCs remain unresolved. A better understanding will enable more efficient and photostable solar cells and optoelectronic devices in the future. Here, this special issue collects the latest cutting-edge research in the photophysics of PSCs and OSCs, contributed by experts on spectroscopy, theory, device physics, and materials science.

14 SOLAR ENERGY↗

THz cyclotron resonance of a 2D hole gas in a GaN/AlN heterostructure

The recent discovery of highly conducting two-dimensional hole gases (2DHGs) in GaN/AlN heterojunctions has opened the door to efficient complementary GaN electronics, a long-standing challenge in wide-bandgap semiconductor device physics. Electrical transport studies and simulations indicate that both heavy- and light-hole valence bands are occupied in these 2DHGs, but direct experimental characterization of the fundamental parameters of the mobile holes remains at an early stage. Here, we use time-domain terahertz spectroscopy and pulsed magnetic fields up to 31 T to directly measure cyclotron resonance of the mobile 2D holes in these GaN-based 2DHGs at low temperature (8 K), revealing key material properties including effective masses, densities, scattering times, and mobilities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Application of control system studio for the NOvA detector control system

In the NO A experiment, the Detector Controls System (DCS) provides a method for controlling and monitoring important detector hardware and environmental parameters. It is essential for operating the detector and is required to have access to roughly 370,000 independent programmable channels via more than 11,600 physical devices. In this paper, we demonstrate an application of Control System Studio (CSS), developed by Oak Ridge National Laboratory, for the NO A experiment. The application of CSS for the DCS of the NO A experiment has been divided into three phases: (1) user requirements and concept prototype on a test-stand, (2) small scale deployment at the prototype Near Detector on the Surface, and (3) a larger scale deployment at the Far Detector. We also give an outline of the CSS integration with the NO A online software and the alarm handling logic for the Front-End electronics.

Lukhanin, Gennadiy↗

Backscatter-Immune Injection-Locked Brillouin Laser in Silicon

As self-sustained oscillators, lasers possess the unusual ability to spontaneously synchronize. These nonlinear dynamics are the basis for a simple yet powerful stabilization technique known as injection locking, in which a laser’s frequency and phase can be controlled by an injected signal. Because of its inherent simplicity and favorable noise characteristics, injection locking has become a workhorse for coherent amplification and high-fidelity signal synthesis in applications ranging from precision atomic spectroscopy to distributed sensing. Within integrated photonics, however, these injection-locking dynamics remain relatively untapped—despite significant potential for technological and scientific impact. In this work, we demonstrate injection locking in a silicon photonic Brillouin laser. Injection locking of this monolithic device is remarkably robust, allowing us to tune the laser emission by a significant fraction of the Brillouin gain bandwidth. Harnessing these dynamics, we demonstrate amplification of small signals by more than 23 dB. Moreover, we demonstrate that the injection-locking dynamics of this system are inherently nonreciprocal, yielding unidirectional control and backscatter immunity in an all-silicon system. This device physics opens the door to strategies for phase-noise reduction, low-noise amplification, and backscatter immunity in silicon photonics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensor-Assisted Fault Mitigation in Quantum Computation

We propose a method for assisting fault mitigation in quantum computation through the use of sensors, co-located near physical qubits. Specifically, we consider using transition edge sensors co-located on silicon substrates hosting superconducting qubits to monitor for energy injection from ionizing radiation that has been demonstrated to increase decoherence in transmon qubits. We generalize from these two physical device concepts and explore the potential advantages of co-located sensors to assist fault mitigation in quantum computation. In the simplest scheme, co-located sensors beneficially assist rejection of calculations potentially affected by environmental disturbances. Investigating the potential computational advantage further required development of an extension to the standard formulation of quantum error correction. In a specific case the standard three-qubit, bit flip quantum correction code, we show that given a 20% overall error probability per qubit, approximately 90% of repeated calculation attempts are correctable. However, when sensor-detectable errors account for 45% of overall error probability, the use of colocated sensors uniquely associated with independent qubits, boosts the fraction of correct final-state calculations to 96% at the cost of rejecting 7% of repeated calculation attempts.

Orrell, John L.↗

Coherently coupled quantum oscillators for quantum reservoir computing

Here, we analyze the properties of a quantum system composed of two coherently coupled quantum oscillators and show through simulations that it fulfills the two properties required for reservoir computing: non-linearity and fading memory. We first show that the basis states of this system apply a set of nonlinear transformations on the input signals and thus can implement neurons. We then show that the system exhibits a fading memory that can be controlled by its dissipation rates. Finally we show that a strong coupling between the oscillators is important in order to ensure complex dynamics and to populate a number of basis state neurons that is exponential in the number of physical devices.

Dudas, Julien↗

Asset Monitoring using Smart Sensing and Advanced Analytics for the Distribution Network

As the electric grid transitions into a highly distributed and intelligent grid, electric utilities are becoming increasingly concerned with monitoring the health and performance of their distribution assets. As Internet of Things technologies and data analytics become inexpensive and ubiquitous, low-cost asset monitoring becomes more feasible. Moreover, using edge analytics, computations can be off-loaded to these intelligent sensors to report only actionable information to the cloud. This needs to be done in a highly distributed manner using non-intrusive sensors and device physics that seamlessly integrates with legacy infrastructure. Here, this paper reviews existing sensor based solutions, identifies t heir issues, proposes a novel solution by exploring the required attributes and proposes an approach for low-cost distribution transformer health monitoring.

Asset monitoring↗

Modeling and Analysis of Hybrid Pixel Detector Deficiencies for Scientific Applications

Semiconductor hybrid pixel detectors often consist of a pixellated sensor layer bump bonded to a matching pixelated readout integrated circuit (ROIC). The sensor can range from high resistivity Si to III-V materials, whereas a Si CMOS process is typically used to manufacture the ROIC. Independent, device physics and electronic design automation (EDA) tools are used to determine sensor characteristics and verify functional performance of ROICs respectively with significantly different solvers. Some physics solvers provide the capability of transferring data to the EDA tool. However, single pixel transient simulations are either not feasible due to convergence difficulties or are prohibitively long. A simplified sensor model, which includes a current pulse in parallel with detector equivalent capacitor, is often used; even then, spice type top-level (entire array) simulations range from days to weeks. In order to analyze detector deficiencies for a particular scientific application, accurately defined transient behavioral models of all the functional blocks are required. Furthermore, various simulations, such as transient, noise, Monte Carlo, inter-pixel effects, etc. of the entire array need to be performed within a reasonable time frame without trading off accuracy. The sensor and the analog front-end can be modeling using a real number modeling language, as complex mathematical functions or detailed data can be saved to text files, for further top-level digital simulations. Parasitically aware digital timing is extracted in a standard delay format (sdf) from the pixel digital back-end layout as well as the periphery of the ROIC. For any given input, detector level worst-case and best-case simulations are performed using a Verilog simulation environment to determine the output. Each top-level transient simulation takes no more than 10-15 minutes. The impact of changing key parameters such as sensor Poissonian shot noise, analog front-end bandwidth, jitter due to clock distribution etc. can be accurately analyzed to determine ROIC architectural viability and bottlenecks. Hence the impact of the detector parameters on the scientific application can be studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VOLTTRON Version 3.x

VOLTTRON™ is an agent execution platform providing services to its agents that allow them to easily communicate with physical devices and other resources. VOLTTRON™ delivers an innovative distributed control and sensing software platform that supports modern control strategies, including agent-based and transaction-based controls. It enables mobile and stationary software agents to perform information gathering, processing, and control actions. VOLTTRON™ can independently manage a wide range of applications, such as HVAC systems, electric vehicles, distributed energy or entire building loads, leading to improved operational efficiency.

Source record↗

VOLTTRON Version 4

VOLTTRON™ is an agent execution platform providing services to its agents that allow them to easily communicate with physical devices and other resources. VOLTTRON™ delivers an innovative distributed control and sensing software platform that supports modern control strategies, including agent-based and transaction-based controls. It enables mobile and stationary software agents to perform information gathering, processing, and control actions. VOLTTRON™ can independently manage a wide range of applications, such as HVAC systems, electric vehicles, distributed energy or entire building loads, leading to improved operational efficiency.

Source record↗

VOLTTRON Version 5.0

VOLTTRON is an agent execution platform providing services to its agents that allow them to easily communicate with physical devices and other resources. VOLTTRON delivers an innovative distributed control and sensing software platform that supports modern control strategies, including agent-based and transaction-based controls. It enables mobile and stationary software agents to perform information gathering, processing, and control actions. VOLTTRON can independently manage a wide range of applications, such as HVAC systems, electric vehicles, distributed energy or entire building loads, leading to improved operational efficiency.

Source record↗

Web Based Beamline Control System (Bluesky Web) v0.1.0

Bluesky Web is a web based interface that provides beam line controls to the end user. It allows users to issue commands to various physical devices at a beam line end station like motors and cameras. It utilizes an open source Python library (Bluesky) as the controller. It uses Bluesky to also allow for running "plans" or a sequence of device operations that can be used when running an experiment. This program is different from other controls technologies because it is intended to be open source and can be accessed from a web browser, as opposed to other paid software that is run as a stand-alone application on a computer.

De Leon, Seij↗

Laboratory Upgrade Point Absorber (LUPA) CAD Files

The Laboratory Upgrade Point Absorber (LUPA) is an open-source wave energy converter designed and tested by Oregon State University. The computer-aided design (CAD) files are provided here in two forms: the original SOLIDWORKS (2021) model as "LUPA SOLIDWORKS.zip" and as a STEP file "LUPA-A1000.step". The bill of materials is provided as an Excel file with assemblies (LUPA-Axxx), part numbers (LUPA-Axxx-Pyyy), part descriptions, manufacturers, and manufacturer part numbers. This comprehensive CAD model represents LUPA as it was deployed in Fall 2022 testing at the O.H. Hinsdale Wave Research Laboratory. The mass properties including mass, center of gravity, and moments of inertia have been overridden for some parts and assemblies to match the physical device properties as determined from experiments. This appears as "overridden by user" when viewing mass properties in SOLIDWORKS. The LUPA-A1000.SLDASM file from the LUPA SOLIDWORKS.zip folder is the topmost assembly, open this file to see the entire model as one assembly. See "PMEC Page", "OpenEI Wiki Page", and the "Signature Project Page" resources below for more information on LUPA.

16 TIDAL AND WAVE POWER↗

Electrochemical strain microscopy: Probing ionic and electrochemical phenomena in solids at the nanometer level

Atomistic and nanometer scale mechanisms of electrochemical reactions and ionic flows in solids in the nanometer-micron range persist as terra incognito in modern science. While structural and electronic phenomena are now accessible to electron and scanning probe microscopy (SPM) techniques, probing nanoscale electrochemistry requires the capability to probe local ionic currents. Here, we discuss principles and applications of electrochemical strain microscopy (ESM), a technique based on probing minute deformations induced by electric bias applied to an SPM tip. ESM imaging and spectroscopy are illustrated for several energy storage and conversion materials. We further argue that down-scaling of physical device structures based on oxides necessitates ionic and electrochemical effects to be taken into account. Future pathways for ESM development are discussed

Jesse, Stephen↗

Stress testing on silicon carbide electronic devices for prognostics and health management.

Power conversion systems for energy storage and other distributed energy resource applications are among the drivers of the important role that power electronics plays in providing reliable electricity. Wide band gap semiconductors such as silicon carbide (SiC) and gallium nitride (GaN) will help increase the performance and efficiency of power electronic equipment while condition monitoring (CM) and prognostics and health management (PHM) will increase the operational availability of the equipment and thereby make it more cost effective. Voltage and/or temperature stress testing were performed on a number of SiC devices in order to accelerate failure modes and to identify measureable shifts in electrical characteristics which may provide early indication of those failures. Those shifts can be interpreted and modeled to provide prognostic signatures for use in CM and/or PHM. Such experiments will also lead to a deeper understanding of basic device physics and the degradation mechanisms behind failure.

42 ENGINEERING↗

High-Efficiency, Commercial Ready CdTe Solar Cells

Colorado State’s F-PACE project explored several ways to increase the efficiency of CdTe solar cells and to better understand the device physics of those cells under study. Increases in voltage, current, and fill factor resulted in efficiencies above 17%. The three project tasks and additional studies are described in detail in the final report. Most cells studied were fabricated at Colorado State using an industry-compatible single-vacuum closed-space-sublimation (CSS) chamber for deposition of the key semiconductor layers. Additionally, some cells were supplied by First Solar for comparison purposes, and a small number of modules were supplied by Abound Solar.

14 SOLAR ENERGY↗

Fiber optic quench detection via optimized Rayleigh Scattering in high-field YBCO accelerator magnets

Yttrium barium copper oxide (YBCO) coated conductors are known for their ability to operate in the superconducting state at relatively high temperatures, even above the boiling point of liquid nitrogen (77 K). When these same conductors are operated at lower temperatures, they are able to operate in much higher magnetic fields than traditional superconductors like NiTi or Nb 3 Sn. Thus, YBCO superconducting magnets are one of the primary options for generating the high magnetic fields needed for future high energy physics devices. Due to slow quench propagation, quench detection remains one of the primary limitations to YBCO magnets. Fiber optic sensing, based upon Rayleigh scattering, has the potential for spatial resolution approaching the wavelength of light, or very fast temporal resolution at low spatial resolution, and a continuum of combinations in between. This project has studied, theoretically and experimentally, YBCO magnets and Rayleigh scattering quench detection systems to demonstrate feasibility of the systems for YBCO quench protection systems. Under this grant an experimentally validated 3D quench propagation model was used to accurately define the acceptable range of spatial and temporal resolutions for effective quench detection in YBCO magnets and to evaluate present-day and potentially improved YBCO conductors. The data volume and speed requirements for quench detection via Rayleigh scattering required the development of a high performance fiber optic based quench detection/data acquisition system and its integration with an existing voltage tap/thermo-couple based system. In this project, optical fibers are tightly co-wound into YBCO magnet coils, with the fiber on top of the conductor as turn-to-turn insulation. Local changes in the temperature or strain of the conductor are sensed by the optical fiber, which is in close thermal and mechanical contact with the conductor. Intrinsic imperfections in the fiber reflect Rayleigh backscattered laser signals that are shifted by the changes in the fiber that are induced by a local change in the YBCO temperature or strain. One goal of this project was to show that modern technology can be used to interrogate the signals from a (very expensive) YBCO magnet to detect an impending quench in time to protect it from self-destruction. The results show that Rayleigh-backscattering interrogated optical fibers (RIOF) have significant advantages over traditional techniques, including very high spatial resolution and the ability to detect a hot-spot well before the peak local temperature becomes so high that the conductor can be damaged. RIOF quench detection is intrinsically faster than voltage taps, and this intrinsic advantage is greater as the coil size and/or current margin increases. We describe the development and testing program performed under the grant.

43 PARTICLE ACCELERATORS↗