Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Remote Monitoring and Diagnostics of Pitch-Bearing Defects in an MW-Scale Wind Turbine Using Pitch Symmetrical-Component Analysis

Recently, multiple wind turbine failure databases have reviewed that the pitch system is one of the subassemblies with the highest failure rates and largest contributors to the overall downtime. Therefore, there has been an increasing interest to provide remote health monitoring for wind turbine pitch system. While most of the research articles are discussing pitch actuation system (hydraulic or electric actuator) faults only, there is very limited research on pitch-bearing-defect detection. This article provides a remote and hardware-free solution to monitor multiaxis pitch-bearing health condition called pitch symmetrical-component analysis. It leverages readily available low-resolution (100 Hz) electrical measurements, mechanical measurements, and control signals from the existing pitch control platform, and innovatively applies symmetrical-component analysis in multiphase ac system to multiaxis pitch control system and introduces multiaxis pitch-bearing degradation trending curves. This hardware-free solution can be directly applied to the existing wind turbines and successfully give the wind farm operator an early warning before multiaxis pitch bearing fails. It has been proved to be accurate, low cost, and has minimum impacts on turbine normal operation, and has been validated by field data from several North America MW-scale wind farms. This approach turns out to be the first hardware-free (no additional hardware needed) method to remotely monitor and diagnose multiaxis wind turbine pitch-bearing condition.

17 WIND ENERGY↗

Laser diagnostics to characterize the in-flame growth of platinum nanoparticles manufactured by the reactive spray deposition technology

Reactive Spray Deposition Technology (RSDT) is an atmospheric pressure, flame-based advanced manufacturing method used to fabricate Membrane Electrode Assemblies (MEAs) for proton exchange fuel cells and water electrolyzers. RSDT combines the flame synthesis of catalyst nanoparticles and their deposition onto the membrane in one step. The properties of the synthesized nanoparticles, such as their Size Distribution Function (SDF), determine the manufactured electrodes’ performance, which can be evaluated when the deposition is complete via ex-situ characterization of the products. Efforts to improve RSDT for manufacturing state-of-the-art MEAs can be significantly enhanced with integrated laser diagnostics that enable in situ measurement of the synthesized catalyst nanoparticles. This paper reports the implementation of laser diagnostics in an RSDT facility and evaluates their potential to assist the manufacturing process. Laser Light Scattering (LS) and Laser-Induced Incandescence (LII) measurements are performed in the oxygen-rich zone of the flame at various distances from the flame fuel jet nozzle downstream of its luminous region. The measurements quantitatively track the evolution in size and volume fraction of platinum-based nanoparticles in two flames that yield different catalytic properties in the manufactured electrodes. The profiles of the measured nanoparticles’ volume fraction along the flame axis can be estimated a priori so that the average nanoparticle sizes can be measured in quasi-real time via LS. Nanoparticles experience an extremely slow growth rate while being convected at distances from 150 nm to 300 nm from the fuel nozzle. Complementary characterizations of the synthesized nanoparticles are performed ex-situ via High-Angle Annular Darkfield Scanning Transmission Electron Microscopy (HAADF-STEM) image analyses of samples collected on grids at a fixed distance from the fuel jet nozzle. Comparing the results from laser and microscopy techniques not only cross-validates the findings but also provides the parameters to infer the bimodal SDF in-situ and yields evidence that the coagulation efficiency of the synthesized nanoparticles has extremely low values in the investigated zone of the flames.

Rayleigh Light Scattering (LS)↗

Novel Infiltration Diagnostics based on Laser-line Scanning and Infrared Temperature Field Imaging

This project targets the building energy efficiency problems induced by building infiltration/leaks. The current infiltration inspection techniques often require extensive visual inspection and/or whole building pressure test. These current techniques cannot meet more than three of the below five criteria of ideal infiltration diagnostics: 1. location and extent diagnostics, 2. building-level application, 3. least surface preparation, 4. weather-proof, and 5. non-disruption to building occupants. These techniques are either too expensive or time consuming, and often lack accuracy and repeatability. They are hardly applicable to facades/facades section. The goal of the project was to develop a novel infiltration diagnostics technology based on laser line-scanning and simultaneous infrared temperature imaging. A laboratory scale experimental setup was designed to mimic a model house of well-defined pressure difference below or above the outside pressure. Algorithms and Matlab-based programs had been developed for recognition of the hole location in infrared images. Our experiment based on laser wavelengths of 450 and 1550 nm and laser beam diameters of 4-25 mm showed that the location of the holes could be identified using laser heating; the diagnostic approach however could not readily distinguish between infiltration and non-infiltration points. To significantly improve the scanning throughput and recognition accuracy, a second approach was explored, developed, and extensively tested. It incorporates a liquid spray on the surface to induce extra phase change cooling effect. In this spray method, we termed it as PECIT (Phase-change Enhanced Cooling Infrared Thermography), phase-change enhanced cooling was used, which significantly amplifies the effect of air flow (infiltration and exfiltration). This heat transfer method worked extremely well to identify infiltration and exfiltration locations with high accuracy and increased throughput. The PECIT technique was systematically developed and tested for through holes with diameters 1 mm to 2 mm, and diagonal lines of 0.5 mm width at different camera-wall distances of 46 cm to 200 cm, under different pressure differences from 5 Pa to 20 Pa, and under different wind conditions. The PECIT technique had either met or exceeded the goals proposed in the project. For exfiltration, we achieved 100% accuracy under a much lower pressure difference of 10 Pa (proposed one: 50 Pa with stretch goal of 15 Pa). For infiltration, we achieved >90% accuracy under a much lower pressure difference of 10 Pa (proposed one: 50 Pa with stretch goal of 15Pa). For exfiltration, we achieved 100% accuracy under a much lower pressure difference of 10 Pa. For infiltration, we achieved 100% accuracy under a much lower pressure difference of 10 Pa. The PECIT technique can reach a throughput of 120 m2/h, which is 4 times the proposed goal for the laser line-scanning and simultaneous infrared temperature imaging approach. For commercialization and market penetration, we had meetings with two companies for feedback collection and further improvement for practical use. Also, we have interacted with Office of Intellectual Property and Technology Transfer of Iowa State University for idea disclosure and patent application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dispersion Validation for Flow Involving a Large Structure

The atmospheric dispersion of contaminants in the wake of a large urban structure is a challenging fluid mechanics problem of interest to the scientific and engineering communities. Magnetic Resonance Velocimetry (MRV) is a relatively new technique that leverages diagnostic equipment used primarily by the medical field to make 3D engineering measurements of flow and contaminant dispersal. SIERRA/Fuego, a computational fluid dynamics (CFD) code at Sandia National Labs is employed to make detailed comparisons to the dataset to evaluate the quantitative and qualitative accuracy of the model. The comparison exercise shows good comparison between model and experimental results, with the wake region downstream of the tall building presenting the most significant challenge to the quantitative accuracy of the model. Model uncertainties are assessed through parametric variations. Some observations are made in relation to the future utility of MDV and CFD, and some productive follow-on activities are suggested that can help mature the science of flow modeling and experimental testing.

54 ENVIRONMENTAL SCIENCES↗

Structural insights into the unique recognition module between α-synuclein peptide and nanobody

Nanobodies are single-domain fragments of antibodies with comparable specificity and affinity to antibodies. They are emerging as versatile tools in biology due to their relatively small size. Here, we report the crystal structure of a specific nanobody Nbα-syn01, bound to a 14 amino acid long peptide of α-synuclein (αSyn), a 140-residue protein whose aggregation is associated with Parkinson's disease. The complex structure exhibits a unique binding pattern where the αSyn peptide replaces the N-terminal region of nanobody. Recognition is mediated principally by extended main chain interaction of the αSyn peptide and specificity of the interaction lies in the central 48–52 region of αSyn peptide. Structure-guided truncation of Nbα-syn01 shows tighter binding to αSyn peptide and improved inhibition of α-synuclein aggregation. The structure of the truncated complex was subsequently determined and was indistinguishable to full length complex as the full-length form had no visible electron density for the N-terminal end. These findings reveal the molecular basis for a previously unobserved binding mode for nanobody recognition of α-synuclein, providing an explanation for the enhanced binding, and potential for an alternate framework for structure-based protein engineering of nanobodies to develop better diagnostic and therapeutic tools.

59 BASIC BIOLOGICAL SCIENCES↗

Limitations of cetane number to predict transient combustion phenomena in high-pressure fuel sprays

Fundamental understanding of in-cylinder processes in diesel engines is important to screen emerging biofuels and advanced combustion modes that can reduce greenhouse gas emissions and regulated pollutants including soot. In this study, the role of fuel properties on spray development and combustion is investigated by systematically isolating chemical and thermophysical effects. Three different fuels are considered, two with similar chemical properties and two with similar thermophysical properties with one fuel common to both groups. Experiments are performed in a constant-pressure flow chamber de-signed to provide stable test conditions and facilitate acquisition of at least 150 injections in quick succession for each fuel under reacting conditions at high-pressure, high-temperature ambient conditions using a modified conventional diesel engine injector. Further, high speed optical diagnostics including rainbow schlieren deflectometry, OH* chemiluminescence, and a two-color pyrometry system are employed to simultaneously image the transient spray and reacting jets. Image analysis is performed to determine liquid length, vapor penetration length, timing and location of first stage and main ignition events, lift-off location, total soot mass, and more. Results show that fuels with similar chemical properties or cetane number (CN) exhibit similar delay times for first stage and main ignition events as may be expected, but very different liquid length, first stage and main ignition locations, lift-off length, apparent turbulent flame speed, and soot formation. As such, the ability to characterize candidate biofuels with CN or other parameters derived from simple flame configurations is called into question. In this study, thermo-physical properties controlling the liquid length are identified as the main contributing factor for the observed differences.

33 ADVANCED PROPULSION SYSTEMS↗

Ethanol pyrolysis kinetics using H 2 O time history measurements behind reflected shock waves

The thermal decomposition of ethanol has been studied under pyrolytic conditions behind reflected shock waves in the 1250 to 1677 K temperature range, at an average pressure of 1.31 atm for a mixture highly diluted in Ar. A laser absorption technique was utilized to measure H 2 O time-histories, and the detailed kinetics mechanism (AramcoMech2.0) was selected among various models from the literature based on its a priori agreement with the experimental data. Sensitivity and rate-of-production analyses were performed and showed that the C 2 H 5 OH→C 2 H 4 + H 2 O (R1) decomposition pathway is almost the sole reaction contributing to H 2 O formation at the early times under the present conditions, allowing an a priori direct measurement of its rate coefficient k 1 . The rate coefficient was determined to be defined as the Arrhenius equation k 1 (s -1 ) = 3.37 × 10 11 exp (–27174 K/T), which is in very good agreement with Kiecherer et al. (2015), where k 1 was also directly determined under similar conditions. Secondary chemical reactions taking place in the thermal decomposition have very low influence in the H 2 O formation during the time-frame selected, leading to an uncertainty for k 1 of approximately 20%. The full H 2 O time histories are useful for validating the full ethanol kinetics mechanism for future validation.

42 ENGINEERING↗

Nondestructive diagnostics of charged particle beams in accelerators

The basic techniques for nondestructive diagnostics and detection of losses of charged particle beams used in accelerator engineering are reviewed. The data provided may help choose the systems for diagnostics and detection of losses of beams and give a qualitative picture of the operation principles of such devices. Quantitative characteristics that define the limits of applicability of each diagnostic technique are outlined.

43 PARTICLE ACCELERATORS↗

Failure, modal, and vibration analysis of a reactor pool cooling pump

Two 75 HP pumps redundantly supply cooling water to the reactor pool of the High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory (ORNL). Due to a recent history of premature bearing failures, one of these pumps has undergone maintenance to deal with possible issues of misalignment and base looseness. Vibration analysis and modal analysis including steady state spectrum, operational deflection shape, run up and down order tracking, and modal impact have been utilized to verify the effectiveness of the maintenance and identify possible remaining failure modes. The studies conclude that the pump is, after the maintenance, in an overall good conditional state as per ISO 10816, but a few failure modes remain. These modes consist of some shaft unbalance, considerable shaft misalignment intensified by piping movement, possible motor ground fault, hydrodynamic issues such as cavitation with modal interaction, and base looseness. These failure modes and their supporting data have been used to make suggestions for future maintenance, to verify the effectiveness of the previous maintenance, and to provide a base on which to check future data. This report will cover the testing setup, methodology, analysis results, and maintenance suggestions.

42 ENGINEERING↗

Failure analysis of a cooling pump using modal and vibration analysis

Four pumps redundantly supply cooling water to a system. All four pumps underwent maintenance during a recently scheduled downtime. During preliminary evaluation following maintenance, one pump, the subject of this document, exhibited higher vibration levels compared to the other three pumps. The pump underwent further performance testing to rule out potential damage resulting from the higher vibration. Vibration analysis and modal analysis including steady state spectrum, operational deflection shape, run up transients, and modal impact have been utilized to identify dynamic characteristics that could contribute to the increased vibration levels. This article will cover the testing setup, methodology, analysis results, and recommendations.

42 ENGINEERING↗

Advanced Diagnostics for High Pressure Spray Combustion.

The development of accurate predictive engine simulations requires experimental data to both inform and validate the models, but very limited information is presently available about the chemical structure of high pressure spray flames under engine- relevant conditions. Probing such flames for chemical information using non- intrusive optical methods or intrusive sampling techniques, however, is challenging because of the physical and optical harshness of the environment. This work details two new diagnostics that have been developed and deployed to obtain quantitative species concentrations and soot volume fractions from a high-pressure combusting spray. A high-speed, high-pressure sampling system was developed to extract gaseous species (including soot precursor species) from within the flame for offline analysis by time-of-flight mass spectrometry. A high-speed multi-wavelength optical extinction diagnostic was also developed to quantify transient and quasi-steady soot processes. High-pressure sampling and offline characterization of gas-phase species formed following the pre-burn event was accomplished as well as characterization of gas-phase species present in the lift-off region of a high-pressure n-dodecane spray flame. For the initial samples discussed in this work several species were identified, including polycyclic aromatic hydrocarbons (PAH); however, quantitative mole fractions were not determined. Nevertheless, the diagnostic developed here does have this capability. Quantitative, time-resolved measurements of soot extinction were also accomplished and the novel use of multiple incident wavelengths proved valuable toward characterizing changes in soot optical properties within different regions of the spray flame.

Skeen, Scott A.↗

Two Photon Absorption Laser Induced Fluorescence for Neutral Hydrogen Profile Measurements

The magnitude and spatial dependence of neutral density in magnetic confinement fusion experiments is a key physical parameter, particularly in the plasma edge. Modeling codes require precise measurements of the neutral density to calculate charge-exchange power losses and drag forces on rotating plasmas. However, direct measurements of the neutral density are problematic. In this work, we proposed to construct a laser-based diagnostic capable of providing spatially resolved measurements of the neutral density in the edge of plasma in the DIII-D tokamak. The diagnostic concept is based on two-photon absorption laser induced fluorescence (TALIF). By injecting two beams of 205 nm light (co or counter propagating), ground state hydrogen (or deuterium or tritium) can be excited from the n = 1 level to the n = 3 level at the location where the two beams intersect. Individually, the beams experience no absorption, and therefore have no difficulty penetrating even dense plasmas. After excitation, a fraction of the hydrogen atoms decay from the n = 3 level to the n = 2 level and emit photons at 656 nm (the H α line). Calculations based on the results of previous TALIF experiments in magnetic fusion devices indicated that a laser pulse energy of approximately 3 mJ delivered in 5 ns would provide sufficient signal-to-noise for detection of the fluorescence. In collaboration with the DIII-D engineering staff and experts in plasma edge diagnostics for DIII-D from Oak Ridge National Laboratory (ORNL), WVU researchers designed a TALIF system capable of providing spatially resolved measurements of neutral deuterium densities in the DIII-D edge plasma. The laser systems were specified, purchased, and assembled at WVU. The TALIF system was tested on a low-power hydrogen discharge at WVU and the plan was to move the instrument to DIII-D for installation in collaboration with ORNL researchers. After budget cuts at DIII-D, the DIII-D facility declined to support installation on their tokamak. Instead, after a no-cost extension, the apparatus was moved to the University of Washington-Seattle and successfully tested on the HIT-SI3 spheromak experiment. As a result of this project, TALIF measurements of the absolutely calibrated neutral density hydrogen and deuterium were obtained in a helicon source and in a spheromak, designs were developed for installation of a TALIF system on a tokamak, and a new, xenon-based calibration scheme was proposed and demonstrated. The xenon-calibration scheme eliminates significant problems that were identified with the standard krypton calibration scheme.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dispersion Validation for Flow Involving a Large Structure Revisited: 45 Degree Rotation

The atmospheric dispersion of contaminants in the wake of a large urban structure is a challenging fluid mechanics problem of interest to the scientific and engineering communities. Magnetic Resonance Velocimetry (MRV) and Magnetic Resonance Concentration (MRC) are relatively new techniques that leverage diagnostic equipment used primarily by the medical field to make 3D engineering measurements of flow and contaminant dispersal. SIERRA/Fuego, a computational fluid dynamics (CFD) code at Sandia National Labs is employed to make detailed comparisons to the dataset to evaluate the quantitative and qualitative accuracy of the model. This work is the second in a series of scenarios. In the prior work, a single large building in an array of similar buildings was considered with the wind perpendicular to a building face. In this work, the geometry is rotated by 45 degrees and improved studies are performed for simulation credibility. The comparison exercise shows conditionally good comparisons between the model and experiment. Model uncertainties are assessed through parametric variations. Various methods of quantifying the accuracy between experiments and data are examined Three-dimensional analysis of accuracy is performed. The effort helped identify deficiencies in the techniques used to make these comparisons, and further methods development therefore becomes one of the main recommendations for follow-on work.

42 ENGINEERING↗

Opinions from Users Across the Lifespan about Fully Autonomous and Rideshare Vehicles with Associated Features

Fully autonomous vehicles have the potential to fundamentally transform the future transportation system. While previous research has examined individuals’ perceptions towards fully autonomous vehicles, a complete understanding of attitudes and opinions across the lifespan is unknown. Therefore, individuals’ awareness, acceptance, and preferences towards autonomous vehicles were obtained from 75 participants through interviews with three diverse groups of participants: 20 automotive engineering graduate students who were building an autonomous concept vehicle, 21 non-technical adults, and 34 senior citizens. The results showed that regardless of age, an individual’s readiness to ride in a fully autonomous vehicle and the vehicle’s requirements were influenced by the users’ understanding of autonomous vehicles. All of the engineering students understand what a fully autonomous vehicle is and this group was the most willing to ride especially compared to the seniors, where only half of the seniors knew what a fully autonomous vehicle is and 58.8% were not at all ready to ride one. The desire to have a manual control option or the ability to override the vehicle was common (90% of the engineering students, 95.2% of the adults, and 82.4% of the seniors), especially for individuals who reported not being ready to ride in a fully autonomous vehicle. The majority of all three groups of participants (85% of the engineering students, 81% of the adults, and 52.9% of the seniors) considered it essential that the vehicle should convey information about the vehicle’s status and intended behavior. Diagnostic information about the vehicle was desired by the engineering students (71.4%), who had a technical understanding of autonomous vehicles and current automotive related technologies. When autonomous vehicles are available, most participants anticipate preferring to use them as a rideshare service model (75% of the engineering students, 38% of the adults, and 27% of the seniors) rather than owning (5% of the engineering students, 19% of the adults, and 21% of the seniors) the autonomous vehicle themselves. Regarding the topic of sharing rides with strangers, both the automotive engineering students (90%) and the adults (52.6%) were comfortable with the idea of pooled rideshare in comparison to the seniors (29.4%). In future efforts, it will be important to include potential autonomous vehicle users of a wide age range as well as physical, cognitive, and visual abilities.

Gangadharaiah, Rakesh↗

EXTINCTION DROPLET SIZING MEASUREMENTS IN DIESEL RELEVANT SPRAYS

A new diagnostic for the quantification of Sauter Mean Diameter (SMD) in high-pressure fuel sprays has been recently developed using combined optical and x-ray measurements at the Georgia Institute of Technology and Argonne National Laboratory, respectively. This diagnostic utilizes liquid scattering extinction measurements from diffuse back-illumination (DBI) imaging, conducted at Georgia Tech, and liquid absorption measurements from x-ray radiography, conducted at Argonne’s Advanced Photon Source. The new diagnostic, entitled the Scattering Absorption Measurement Ratio (SAMR), quantifies two-dimensional distributions of path-integrated SMD, enabling construction of the spatial history of drop size development within practical fuel sprays. This technique offers unique benefits over conventional drop-sizing methods in that it can be more robust in optically dense regions of the spray, while also providing high spatial resolution of the corresponding droplet field. The spatially-resolved SMD measurements that result from the SAMR diagnostic will be especially valuable to the engine modeling community for the quantitative validation of spray submodels in engine CFD codes. The methodology for quantification of SMD distributions using the SAMR technique has been previously introduced. This thesis aims to extend the initial development of the SAMR technique by presenting in detail: the experimental methodologies used in the SAMR technique, including the development of an ideal DBI setup for this technique; the data processing methodologies developed by the author; two-dimensional Sauter Mean Diameter measurements within diesel sprays for various experimental conditions; a summary of the various sources of measurement uncertainty; an assessment for how the sources of uncertainty affect the quantified SMD; and paths to improve the technique moving forward. The SMD results show that for low ambient density conditions droplets decrease in size as radial and axial position increases. For high ambient density conditions, however, the droplets show a stable size near the spray centerline and steadily increase in size as distance from the centerline increases. Additionally, this work provides 2-D droplet sizing maps which are particularly useful for model validation.

33 ADVANCED PROPULSION SYSTEMS↗

Magnetic diagnostics for the lithium tokamak experiment

The lithium tokamak experiment (LTX) is a spherical tokamak with R{sub 0}=0.4 m, a=0.26 m, B{sub TF}{approx}3.4 kG, I{sub P}{approx}400 kA, and pulse length {approx}0.25 s. The focus of LTX is to investigate the novel low-recycling lithium wall operating regime for magnetically confined plasmas. This regime is reached by placing an in-vessel shell conformal to the plasma last closed flux surface. The shell is heated and then coated with liquid lithium. An extensive array of magnetic diagnostics is available to characterize the experiment, including 80 Mirnov coils (single and double axis, internal and external to the shell), 34 flux loops, 3 Rogowskii coils, and a diamagnetic loop. Diagnostics are specifically located to account for the presence of a secondary conducting surface and engineered to withstand both high temperatures and incidental contact with liquid lithium. The diagnostic set is therefore fabricated from robust materials with heat and lithium resistance and is designed for electrical isolation from the shell and to provide the data required for highly constrained equilibrium reconstructions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In Situ Laser Induced Florescence Measurements of Fuel Dilution from Low Load to Stochastic Pre Ignition Prone Conditions

This work employs a novel laser induced fluorescence (LIF) diagnostic to measure fuel dilution in a running single cylinder research engine operated at stochastic pre ignition (SPI) and non-SPI prone conditions. Measurements of LIF based fuel dilution are quantified over a range of engine loads and fuel injection timings for two fuels. The in situ LIF measurements of fuel/lubricant interactions illustrate regions of increased fuel dilution from fuel-wall interactions and is believed to be a fundamental underpinning to generating top ring zone liquid conditions conducive to SPI. Furthermore, a novel level of dye doped in the fuel, between 50 to 500 ppm was used as the fluorescence source, at engine operating speed of 2000r/min from 5 to 18 bar of IMEPg injection timings was swept for two fuels of varying volatility. The direct real time LIF measurements highlight that there are non-linear trends in fuel dilution beyond simple dependencies of fuel volatility, injection duration or injection timing, suggesting that further understanding of spray interaction with engine surfaces and the turbulent field are needed to quantify fuel dilution effects that are conducive to SPI. Moreover, results show the potential of this diagnostic technique as an additional tool for quantifying spray and fuel mixing in fundamental studies deployable across a variety of engine loads from law to full load.

47 OTHER INSTRUMENTATION↗

Halide Perovskites and Their Derivatives for Efficient, High‐Resolution Direct Radiation Detection: Design Strategies and Applications

Abstract The past decade has witnessed a rapid rise in the performance of optoelectronic devices based on lead‐halide perovskites (LHPs). The large mobility‐lifetime products and defect tolerance of these materials, essential for optoelectronics, also make them well‐suited for radiation detectors, especially given the heavy elements present, which is essential for strong X‐ray and γ‐ray attenuation. Over the past decade, LHP thick films, wafers, and single crystals have given rise to direct radiation detectors that have outperformed incumbent technologies in terms of sensitivity (reported values up to 3.5 × 10 6 µC Gy air −1 cm −2 ), limit of detection (directly measured values down to 1.5 nGy air s −1 ), along with competitive energy and imaging resolution at room temperature. At the same time, lead‐free perovskite‐inspired materials (e.g., methylammonium bismuth iodide), which have underperformed in solar cells, have recently matched and, in some areas (e.g., in polarization stability), surpassed the performance of LHP detectors. These advances open up opportunities to achieve devices for safer medical imaging, as well as more effective non‐invasive analysis for security, nuclear safety, or product inspection applications. Herein, the principles behind the rapid rises in performance of LHP and perovskite‐inspired material detectors, and how their properties and performance link with critical applications in non‐invasive diagnostics are discussed. The key strategies to engineer the performance of these materials, and the important challenges to overcome to commercialize these new technologies are also discussed.

36 MATERIALS SCIENCE↗