Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

TPSAS-NF1676L-31770-DND

HREBSD (high resolution electron backscatter diffraction) is a scanning electron microscope based diffraction technique that measures stress, elastic strain and dislocation density in crystalline materials with a spatial resolution on the order of tens of nanometers. This information represents a glut of quantitative data that may be directly incorporated in microscale crystal plasticity models. However, concerns over the accuracy of HREBSD make integration of microscopy data with material models problematic. This presentation addresses a number of issue concerning the accuracy of HREBSD, including pattern center error, cross-correlation error and random noise. Additionally, a computational framework is presented that allows for rapid, non-deterministic calibration of material models. Finally, several tests cases are presented where HREBSD is cross-validated with other diffraction techniques: X-ray diffraction, electron channeling contrast imaging and transmission electron microscopy. The accuracy of HREBSD, when incorporating these new techniques, is sufficient to measure local stress to below 10 MPa and to detect individual dislocations.

Timothy J Ruggles↗

Growth of twin-free heteroepitaxial diamond on Ir/YSZ/Si(111)

Heteroepitaxial nucleation and growth of twin-free diamond on Ir(111) is reported. The bias enhanced nucleation (BEN) technique was applied in a microwave plasma chemical vapor deposition setup to induce diamond nucleation on the new multilayer stack Ir/YSZ/Si(111). We demonstrate that the gathering of the diamond nuclei in so-called 'domains', a pattern formation process unique for diamond nucleation on iridium, is also present on Ir(111). The 1-2 nm thick carbon layer deposited by BEN does not show any crystalline diamond structures in electron diffraction and high resolution lattice imaging microscopy. In contrast, x-ray photoelectron diffraction (XPD) measurements yield C 1s diffractograms with clear threefold symmetry. The main features are comparable to measurements on diamond (111) single crystal surfaces. The weaker fine structure in the XPD patterns of the BEN layers is attributed to some disorder due to the harsh ion bombardment. However, this ion bombardment did not induce any measurable amount of twinning as deduced from the threefold symmetry. After 3 h diamond growth, the signal due to twins in the x-ray diffraction pole figures is still below the noise level of {approx}1%. Negligible twinning and the low mosaic spread of 0.96 deg. (tilt) and 1.85 deg. (twist) indicate that these films mark a breakthrough toward heteroepitaxial diamond films with (111) orientation. They provide interesting growth substrates, e.g., for phosphorous doped diamond or for the formation of heterojunction devices by deposition of wurtzite-type wide band gap semiconductor materials.

36 MATERIALS SCIENCE↗

Phase Sensitive X-Ray Diffraction Imaging Study of Protein Crystals

The study of defects and growth of protein crystals is of importance in providing a fundamental understanding of this important category of systems and the rationale for crystallization of better ordered crystals for structural determination and drug design. Yet, as a result of the extremely weak scattering power of x-rays in protein and other biological macromolecular crystals, the extinction lengths for those crystals are extremely large and, roughly speaking, of the order of millimeters on average compared to the scale of micrometers for most small molecular crystals. This has significant implication for x-ray diffraction and imaging study of protein crystals, and presents an interesting challenge to currently available x-ray analytical techniques. We proposed that coherence-based phase sensitive x-ray diffraction imaging could provide a way to augment defect contrast in x-ray diffraction images of weakly diffracting biological macromolecular crystals. I shall examine the principles and ideas behind this approach and compare it to other available x-ray topography and diffraction methods. I shall then present some recent experimental results in two model protein systems-cubic apofemtin and tetragonal lysozyme crystals to demonstrate the capability of the coherence-based imaging method in mapping point defects, dislocations, and the degree of perfection of biological macromolecular crystals with extreme sensitivity. While further work is under way, it is intended to show that the observed new features have yielded important information on protein crystal perfection and nucleation and growth mechanism otherwise unobtainable.

Hu, Z. W.↗

Bragg Coherent Imaging of Fluctuating Domains

This review presents two examples of domain dynamics in crystalline solid state samples which were imaged recently with synchrotron X-rays by Bragg Coherent Diffraction methods. Domains are associated with sub-atomic phase shifts in the structure which are revealed by the strong phase contrast associated with Bragg diffraction. At low temperatures, La2-xSrxNiO4 has an antiferromagnetic spin-ordered phase with correlation lengths of 200 nm; its domains are imaged with magnetic Bragg Ptychography to visualize their slow fluctuations. Hydrothermally synthesized nanocrystalline BaTiO3 is found to be made up of ~50 nm domains using Bragg Coherent Diffraction Imaging; electric field induced movement of its internal domain walls is a likely explanation of the nano-material's anomalously large dielectric constant, which is used in the manufacture of multilayer ceramic capacitors

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dynamic crystal rotation resolved by high-speed synchrotron X-ray Laue diffraction

Dynamic compression experiments are performed on single-crystal Si under split Hopkinson pressure bar loading, together with simultaneous high-speed (250–350 ns resolution) synchrotron X-ray Laue diffraction and phase-contrast imaging. A methodology is presented which determines crystal rotation parameters, i.e. instantaneous rotation axes and angles, from two unindexed Laue diffraction spots. Two-dimensional translation is obtained from dynamic imaging by a single camera. High-speed motion of crystals, including translation and rotation, can be tracked in real time via simultaneous imaging and diffraction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microstructure-Property Relationships in Epitaxial Cu(In, Ga)Se2 Solar-Cell Absorbers

Epitaxially grown Cu(In,Ga)Se 2 (CIGS) absorber layers were analyzed by various techniques in scanning electron microscopy in order to reveal microstructure-property relationships in these thin films. Owing to their epitaxial nature, these CIGS absorber layers do not contain any grain boundaries, but only anti-phase domains (APDs) and dislocations. By combining electron channeling-contrast imaging, electron backscatter diffraction, and cathodoluminescence (CL), in some cases on identical specimen positions of polished cross-sections of CIGS/Mo/glass stacks, it was possible to correlate the presence and orientations of APDs and dislocations with the lateral distributions of the CL intensity and emission-peak energy. We studied CIGS layers with three different [Ga]/([Ga]+[In]) ratios as well as with and without NaF/KF treatments. Considerable differences between the CIGS layer properties in the microstructure-property relationships were found, depending on the growth parameters. Dislocations in the epitaxial CIGS layers do not tend to exhibit strong CL intensity decreases, which contrasts with the situation in numerous other semiconductor materials.

anti-phase domains↗

High-resolution projection image reconstruction of thick objects by hard x-ray diffraction microscopy

Hard x-ray diffraction microscopy enables us to observe thick objects at high spatial resolution. The resolution of this method is limited, in principle, by only the x-ray wavelength and the largest scattering angle recorded. As the resolution approaches the wavelength, the thickness effect of objects plays a significant role in x-ray diffraction microscopy. In this paper, we report high-resolution hard x-ray diffraction microscopy for thick objects. We used highly focused coherent x rays with a wavelength of {approx}0.1 nm as an incident beam and measured the diffraction patterns of a {approx}150-nm-thick silver nanocube at the scattering angle of {approx}3 deg. We observed a characteristic contrast of the coherent diffraction pattern due to only the thickness effect and collected the diffraction patterns at nine incident angles so as to obtain information on a cross section of Fourier space. We reconstructed a pure projection image by the iterative phasing method from the patched diffraction pattern. The edge resolution of the reconstructed image was {approx}2 nm, which was the highest resolution so far achieved by x-ray microscopy. The present study provides us with a method for quantitatively observing thick samples at high resolution by hard x-ray diffraction microscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamic deformation and fracture of single crystal silicon: Fracture modes, damage laws, and anisotropy

Impact fracture of single-crystal Si is critical to long-term reliability of electronic devices and solar cells for its wide use as components or substrates in semiconductor industry. Single-crystal Si is loaded along two different crystallographic directions with a split Hopkinson pressure bar integrated with an in situ x-ray imaging and diffraction system. Bulk stress histories are measured, simultaneously with x-ray phase contrast imaging (XPCI) and Laue diffraction. Damage evolution is quantified with grayscale maps from XPCI. Single-crystal Si exhibits pronounced anisotropy in fracture modes, and thus fracture strengths and damage evolution. For loading along [11¯ 0] and viewing along [001], (1¯1¯0)[11¯ 0] cleavage is activated and induces horizontal primary cracks followed by perpendicular wing cracks. However, for loading along [011¯] and viewing along [111], random nucleation and growth of shear and tensile-splitting crack networks lead to catastrophic failure of materials with no cleavage. The primary-wing crack mode leads to a lower characteristic fracture strength due to predamage, but a more concentrated strength distribution, i.e., a higher Weibull modulus, compared to the second loading case. Furthermore, the sequential primary cracking, wing cracking and wing-crack coalescence processes result in a gradual increase of damage with time, deviating from theoretical predictions. Particle size and aspect ratios of fragments are discussed with postmortem fragment analysis, which verifies fracture modes observed in XPCI.

36 MATERIALS SCIENCE↗

Spectroscopic Fourth-order Coronagraph for the Characterization of Terrestrial Planets at Small Angular Separations from Host Stars

We propose a new approach for high-contrast imaging at the diffraction limit using segmented telescopes in a modest observation bandwidth. This concept, named “spectroscopic fourth-order coronagraphy,” is based on a fourth-order coronagraph with a focal-plane mask that modulates the complex amplitude of the Airy disk along one direction. While coronagraphs applying the complex amplitude mask can achieve the theoretical limit performance for any arbitrary pupils, the focal-plane mask severely limits the bandwidth. Here, focusing on the fact that the focal-plane mask modulates the complex amplitude along one direction, we noticed that the mask can be optimized for each spectral element generated by a spectrograph. We combine the fourth-order coronagraph with two spectrographs to produce a stellar spectrum on the focal plane and reconstruct a white pupil on the Lyot stop. Based on the wave-front analysis of an optical design applying an Offner-type imaging spectrograph, we found that the achievable contrast of this concept is 10{sup −10} at 1.2–1.5 times the diffraction limit over the wavelength range of 650–750 nm for the entrance pupil of the LUVOIR telescope. Thus, this coronagraph concept could bring new habitable planet candidates not only around G- and K-type stars beyond 20–30 pc but also around very nearby M-type stars. This approach potentially promotes the characterization of the atmospheres of nearby terrestrial planets with future on- and off-axis segmented large telescopes.

47 OTHER INSTRUMENTATION↗

Near-field focusing of an optical wave by diffraction gratings

We report the investigation results for spatially-localised light structures (photonic nanojets) under near-field optical radiation scattering on phase diffraction gratings. Main parameters of photonic nanojets from gratings with sawtooth, rectangular and hemispherical groove profiles are obtained by numerical electrodynamic simulation. It is found that by varying a period, degree of filling, groove shape and parameters of optically contrast coating of the diffraction grating one can control the characteristics of the produced photonic jets in a wide range. (laser beams)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transmission Electron Microscopy of Single Wall Carbon Nanotube/Polymer Nanocomposites: A First-Principles Study

The physics of HRTEM image formation and electron diffraction of SWCNT in a polymer matrix were investigated theoretically on the basis of the multislice method, and the optics of a FEG Super TWIN Philips CM 200 TEM operated at 80 kV. The effect of nanocomposite thickness on both image contrast and typical electron diffraction reflections of nanofillers were explored. The implications of the results on the experimental applicability to study dispersion, chirality and diameter of nanofillers are discussed.

Sola, Francisco↗

Interferometric hard x-ray phase contrast imaging at 204 nm grating period

We report on hard x-ray phase contrast imaging experiments using a grating interferometer of approximately 1/10th the grating period achieved in previous studies. We designed the gratings as a staircase array of multilayer stacks which are fabricated in a single thin film deposition process. We performed the experiments at 19 keV x-ray energy and 0.8 {mu}m pixel resolution. The small grating period resulted in clear separation of different diffraction orders and multiple images on the detector. A slitted beam was used to remove overlap of the images from the different diffraction orders. The phase contrast images showed detailed features as small as 10 {mu}m, and demonstrated the feasibility of high resolution x-ray phase contrast imaging with nanometer scale gratings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

JWST/MIRI Coronagraphic Performances as Measured on-Sky

Context . Characterization of directly imaged exoplanets is one of the most eagerly anticipated science functions of the James Webb Space Telescope . MIRI, the mid-IR instrument, has the capability to provide unique spatially resolved photometric data points in a spectral range never before achieved for such objects. Aims . We aim to present the very first on-sky contrast measurements of the MIRI coronagraphs. In addition to a classical Lyot coronagraph at the longest wavelength, this observing mode implements the concept of the four-quadrant phase mask for the very first time in a space telescope. Methods . We observed single stars together with a series of reference stars to measure raw contrasts as they are delivered on the detector, as well as reference-subtracted contrasts. Results . The MIRI coronagraphs achieve raw contrasts better than 10 −3 at the smallest angular separations (within 1″) and about 10 −5 farther out (beyond 5 ~ 6″). Subtracting the residual diffracted light left behind the coronagraph has the potential to bring the final contrast down to the background- and detector-limited noise floor at most angular separations (a few times 10 −5 at less than 1″). Conclusions . The MIRI coronagraphs behave as expected from simulations. In particular, the raw contrasts for all four coronagraphs are fully consistent with the diffractive model. Contrasts obtained by subtracting reference stars also meet expectations and are fully demonstrated for two four-quadrant phase masks (F1065C and F1140C). The worst contrast, measured at F1550C, is very likely due to a variation in the phase aberrations at the primary mirror during the observations, and not an issue with the coronagraph itself. We did not perform reference star subtraction with the Lyot mask at F2300C, but we anticipate that it would bring the contrast down to the noise floor.

High angular resolution instrumentation↗

Multi-Star Wavefront Control at the Occulting Mask Coronagraph Testbed: Monochromatic Laboratory Demonstration for the Roman Coronagraph Instrument

The Astro2020 decadal survey recommended the Habitable Worlds Observatory (HWO), NASA’s direct imaging flagship mission, with a goal to achieve a statistically robust mission yield of 25 or more potentially habitable exoplanets. One way to achieve is to increase the instrument effectiveness by introducing additional bright, nearby targets. A majority of Sun-like stars have a stellar companion that can introduce additional noise into the field of view of any high-contrast imaging instrument and enabling exoplanet discovery around binary stars represents a path to increased corona graphic instrument efficiency by increasing the available science target pool of bright nearby stars. This includes both of the Alpha Centauri A and B stars which would represent the top science target for direct imaging if companion leakage could be suppressed. Multi-Star Wavefront Control(MSWC) is a technique that removes stellar leakage from both stellar components, enabling direct imaging of exoplanets in many binary star systems which can potentially increase corona graphic instrument effectivenessWe present the latest testbed results obtained with MSWC as part of the technology development effort focusing on demonstrations conducted on the Occulting Mask Coronagraph (OMC) testbed at JPL during thevacuum test window last winter, with an additional vacuum test planned for this fall. The MSWC mask consists of a shaped pupil mask similar to the one used for the Wide-Field of View mode, but also includes a set of superimposed, regularly-spaced dots that serve as a diffraction grating. OMC has a layout similar to the RomanSpace Telescope coronagraph instrument and configured with a binary imaging mode with a MSWC mask using same design as the contributed mask for the Roman coronagraph. Our testbed results represent the first demonstrations of this technique using the recently installed full binary source. We present results demonstrating suppression in the Super-Nyquist regime for the 3rd diffraction order reaching 8.7e-9 contrast with the Roman pupil. In addition, we present results obtained with a physical binary source and running MSWC in a binary star regime demonstrating 9.6e-8 contrast for a geometry matching potential Alpha Centauri observations in a515 nm monochromatic wavelength (similar but bluer than for Band 1) using the 5th diffraction order. Planned demonstrations in the upcoming vacuum window this fall will focus on Band 3d and Band 4 using the full MSWC mode for an Alpha Centauri geometry.

Roman Coronagraph Instrument↗

X-Ray Diffraction and Imaging Study of Imperfections of Crystallized Lysozyme with Coherent X-Rays

Phase-sensitive x-ray diffraction imaging and high angular-resolution diffraction combined with phase contrast radiographic imaging are employed to characterize defects and perfection of a uniformly grown tetragonal lysozyme crystal in symmetric Laue case. The fill width at half-maximum (FWHM) of a 4 4 0 rocking curve measured from the original crystal is approximately 16.7 arcseconds, and defects, which include point defects, line defects, and microscopic domains, have been clearly observed in the diffraction images of the crystal. The observed line defects carry distinct dislocation features running approximately along the <110> growth front, and they have been found to originate mostly at a central growth area and occasionally at outer growth regions. Individual point defects trapped at a crystal nucleus are resolved in the images of high sensitivity to defects. Slow dehydration has led to the broadening of the 4 4 0 rocking curve by a factor of approximately 2.4. A significant change of the defect structure and configuration with drying has been revealed, which suggests the dehydration induced migration and evolution of dislocations and lattice rearrangements to reduce overall strain energy. The sufficient details of the observed defects shed light upon perfection, nucleation and growth, and properties of protein crystals.

Hu, Zheng-Wei↗

Multi-Star Wavefront Control at the Occulting Mask Coronagraph Testbed: Monochromatic Laboratory Demonstration for the Roman Coronagraph Instrument

The Astro2020 decadal survey recommended a direct imaging flagship mission with a goal for mission yield of 25 or more potentially habitable exoplanets. A majority of Sun-like stars have a stellar companion that can introduce additional noise into the field of view of any high-contrast imaging instrument and enabling exoplanet discovery around binary stars represents a path to increased coronagraphic instrument efficiency. This includes both of the Alpha Centauri A and B stars which would represent the top science target for direct imaging if companion leakage can be suppressed. Multi-Star Wavefront Control (MSWC) is a technique that removes stellar leakage from both stellar components, enabling direct imaging of exoplanets in many binary star systems. We present the latest testbed results obtained with MSWC as part of the technology development effort focusing on demonstrations conducted on the Occulting Mask Coronagraph (OMC) testbed at JPL. OMC has a layout similar to the Roman Space Telescope coronagraph instrument (CGI) and is outfitted with a MSWC mask with the same design as the contributed mask for the Roman CGI. Our testbed results represent the first demonstrations of this technique using the recently installed full binary source for a geometry matching potential Alpha Centauri observations. Technical Review Abstract: The Astro2020 decadal survey recommended a direct imaging flagship mission with a goal for mission yield of 25 or more potentially habitable exoplanets. A majority of Sun-like stars have a stellar companion that can introduce additional noise into the field of view of any high-contrast imaging instrument and enabling exoplanet discovery around binary stars represents a path to increased coronagraphic instrument efficiency by increasing the available science target pool of bright nearby stars. This includes both of the Alpha Centauri A and B stars which would represent the top science target for direct imaging if companion leakage can be suppressed. Multi-Star Wavefront Control (MSWC) is a technique that removes stellar leakage from both stellar components, enabling direct imaging of exoplanets in many binary star systems . We present the latest testbed results obtained with MSWC as part of the technology development effort focusing on demonstrations conducted on the Occulting Mask Coronagraph (OMC) testbed at JPL during the completed first vacuum window and recent results from the ongoing second vacuum window. The MSWC mask consists of a shaped pupil mask similar to the one used for the Wide-Field of View mode but also includes a set of superimposed, regularly-spaced dots that serve as a diffraction grating. OMC has a layout similar to the Roman Space Telescope coronagraph instrument (CGI) and is configured with a binary imaging mode with a MSWC mask using same design as the contributed mask for the Roman CGI. Our testbed results represent the first demonstrations of this technique using the recently installed full binary source. We present results obtained in Super-Nyquist regime demonstrating suppression in the Super-Nyquist regime for the 3rd diffraction order reaching 8.7e-9 contrast with the Roman pupil. In addition, we present results obtained with the binary-star regime demonstrating 9.6e-8 contrast for a geometry matching potential Alpha Centauri observations in a monochromatic wavelength similar to Band 1. Planned demonstrations in the 2nd vacuum window will focus on Band 3d and Band 4 using the full MSWC mode for an Alpha Centauri geometry.

High-contrast imaging↗

Polycrystalline oxides formation during transient oxidation of (001) Cu-Ni binary alloys studied by in situ TEM and XRD.

The nucleation and growth of Cu{sub 2}O and NiO islands due to oxidation of Cu{sub x}Ni{sub 1-x} (001) films were monitored, at various temperatures, by in situ ultra-high vacuum (UHV) transmission electron microscopy (TEM) and in situ synchrotron X-ray diffraction (XRD). In remarkable contrast to our previous observations of Cu and Cu-Au oxidation, irregular-shaped polycrystalline oxide islands formed with respect to the Cu-Ni alloy film, and an unusual second oxide nucleation stage was noted. In situ XRD experiments revealed that NiO formed first epitaxially, then other orientations appeared, and finally polycrystalline Cu{sub 2}O developed as the oxidation pressure was increased. The segregation of Ni and Cu towards or away, respectively, from the alloy surface during oxidation could disrupt the surface and cause polycrystalline oxide formation.

43 PARTICLE ACCELERATORS↗

Distortions and Stabilization of Simple Cubic Calcium at High Pressure and Low Temperature

Ca-III, the first superconducting calcium phase under pressure, was identified as simple-cubic (sc) by previous X-ray diffraction (XRD) experiments. In contrast, all previous theoretical calculations showed that sc had a higher enthalpy than many proposed structures and had an imaginary (unstable) phonon branch. By using our newly developed submicrometer high-pressure single-crystal XRD, cryogenic high-pressure XRD, and theoretical calculations, we demonstrate that Ca-III is neither exactly sc nor any of the lower-enthalpy phases, but sustains the sc-like, primitive unit by a rhombohedral distortion at 300 K and a monoclinic distortion below 30 K. This surprising discovery reveals a scenario that the high-pressure structure of calcium does not go to the zero-temperature global enthalpy minimum but is dictated by high-temperature anharmonicity and low-temperature metastability fine-tuned with phonon stability at the local minimum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗