Search NASA⌕ Search

SEARCH · Search NASA

Results for “digital pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Alternative signal processing techniques for a pulsed laser Doppler velocimeter system

The laser Doppler velocimeter system (LDV) being tested at NASA MSFC, Alabama, relies on a bank of classical filters for processing the returned lidar signal. Due to the complexity of this conventional filter system, alternative signal processing methods have been proposed for obtaining the Doppler spectrum. The fast Fourier transform (FFT) and the pulse-pair estimator are two techniques which appear to offer some advantages over the existing system. The work reported employs digital computer simulation to compare and evaluate these two processing methods for determining the first and second moments of the LDV velocity spectrum.

Calhoun, M. D.↗

Pulse compression using binary phase codes

In most MST applications pulsed radars are peak power limited and have excess average power capacity. Short pulses are required for good range resolution, but the problem of range ambiguity (signals received simultaneously from more than one altitude) sets a minimum limit on the interpulse period (IPP). Pulse compression is a technique which allows more of the transmitter average power capacity to be used without sacrificing range resolution. As the name implies, a pulse of power P and duration T is in a certain sense converted into one of power nP and duration T/n. In the frequency domain, compression involves manipulating the phases of the different frequency components of the pulse. One way to compress a pulse is via phase coding, especially binary phase coding, a technique which is particularly amenable to digital processing techniques. This method, which is used extensively in radar probing of the atmosphere and ionosphere is discussed. Barker codes, complementary and quasi-complementary code sets, and cyclic codes are addressed.

Farley, D. T.↗

Real-Time Keratometer

Optical/electronic keratometer system produces contour map of corneal surface illuminated by infrared light pulses. Prevents operator error and eliminates need to apply fluorescent liquids to cornea. Keratometer provides both video display and numerical recording for corneal-transplant and radial-keratotomy surgery and for contact-lens fitting. Optical system of keratometer, circular grating pattern transmitted to corneal surface reflected onto identical circular grating on surface of fiber plate, producing Moire pattern. Data-analysis-and-display mode, laser light pulsed, and Moire pattern converted to digital information in frame grabber. Digital picture information sent to computer for processing and display.

Frazer, Robert E.↗

Processing Laser-Velocimetric Data By Vector Scanning

Velocity plots obtained in minutes instead of hours. Velocity scanning technique for processing flow-field data from pulsed-laser-velocimetry images into two-dimensional velocity-vector maps. Requires no special equipment other than charge-coupled-device (CCD) camera, circuitry to digitize output of camera, and computer. Once image data digitized, all processing done in computer.

Wernet, Mark P.↗

High Sensitivity Readout and Data Processing for Environmental Spectral Radiation Measurements

We have developed a new version of high sensitivity electronics front end and analog signal processing for use with high pressure ionization chambers in environmental radiation measurements. The readout circuit provides low noise signal readout from individual events of gas ionization. Readout electronics is connected to the analog-to?digital converter providing continuous high rate data sampling. The data processing algorithm allows noise rejection and extraction of pulse shape and amplitude information related to the ionization loss in the gas for each ionization event. The output of the detector could be presented in a traditional way as the accumulated ionization charge per unit time, and as a signal amplitude spectroscopic distribution. Results of the initial evaluation are presented. These results were obtained using the designed electronics connected to the RSS-1013 Reuter-Stokes high pressure ionization chamber filled with Ar at 25 atm. The HPIC detector was tested using cosmic radiation and several external radiation sources. Combined measurements of total ionization and ionization spectrum in the detector provide a new type of powerful instrument capable of better separation between the natural background radiation and the radiation form external sources, as well as the improved low energy gamma radiation detection.

Popov, Vladimir↗

Pulse shape discrimination performance of stilbene coupled to low-noise silicon photomultipliers

Pulse shape discrimination (PSD) techniques can be used to discern between neutron and gamma-ray interactions in certain organic scintillators. Traditionally, photomultiplier tubes (PMTs) have been used in organic-scintillator assemblies. However, silicon photomultipliers (SiPMs) have great potential to be used in many applications in which PMTs have been predominantly used, including those utilizing PSD techniques. To evaluate the current state of the art of the SiPM technology, SensL's 6-mm B-Series and C-Series SiPMs were compared to a fast Hamamatsu PMT in conjunction with a 6×6×6-mm3 stilbene organic scintillator to assess the PSD performance of the detector assemblies. Measurements with a Cf-252 source were performed and a figure of merit (FOM) for discriminating between neutron and gamma-ray pulses between 100 keVee and 200 keVee was calculated for each assembly. A digital charge-integration PSD technique was used to process all measured data. The FOM for the B-Series SiPM, PMT, and C-Series SiPM was 1.37, 1.93, and 2.13, respectively. The C-Series SiPM was shown to perform as well as the PMT in the experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monolithic GaAs digitizer for space-based laser pulse spreading effect

A 6-bit 1-GHz digitizer was designed to analyze the 1-ns pulse spreading effects in a space based altimeter. The digitizer consisted of four 4-bit flash A/D converters and a 6-bit encoder. Also, the converter utilized four 4-bit converters and a 4-to-6 bit encoder to achieve 6 bit resolution at the 1 GHz sample rate. The design was unique because it utilized only the inverters and NOR gates for the converters and encoder, hence it could be fabricated using the existing state-of-the-art GaAs processing techniques. This GHz digitizer has many commercial applications. It could be applicable to: (1) digital microwave transmission system for the telecommunication industries, (2) pulse monitoring in high kinetic chemical reactions, (3) transient signals in the medical field, and (4) microwave signals in astronomy.

Lao, Bennig↗

Lidar Luminance Quantizer

This innovation addresses challenges in lidar imaging, particularly with the detection scheme and the shapes of the detected signals. Ideally, the echoed pulse widths should be extremely narrow to resolve fine detail at high event rates. However, narrow pulses require wideband detection circuitry with increased power dissipation to minimize thermal noise. Filtering is also required to shape each received signal into a form suitable for processing by a constant fraction discriminator (CFD) followed by a time-to-digital converter (TDC). As the intervals between the echoes decrease, the finite bandwidth of the shaping circuits blends the pulses into an analog signal (luminance) with multiple modes, reducing the ability of the CFD to discriminate individual events

Quilligan, Gerard↗

Air Shower Measurements with Radio Antennas: The LOPES Project

LOPES is set up at the location of the KASCADE-Grande extensive air shower experiment in Karlsruhe, Germany and aims to measure and calibrate radio pulses from Extensive Air Showers. LOPES is designed as a digital radio interferometer using high bandwidths and fast data processing and profits from the reconstructed air shower observables of KASCADE-Grande. First results of the LOPES experiment are very promising for a future large scale application of the technique to detect cosmic rays of highest energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of a digitizer for the plastic scintillation detectors of time-of-flight mass measurements

A CAEN DT5742 digitizer has been investigated to process the fast signals from the photomultiplier tubes of the time-of-flight detectors for fast ion beams. A test setup consisting of two plastic scintillation detectors and a pulsed laser source provided signals which were recorded by the digitizer and systematically analyzed with different algorithms to derive the amplitude, rise time and arrival time of the detection signal. To obtain the best amplitude and time resolutions, various optimization techniques including peak fitting and signal smoothing, interpolation improvement, and time-walk correction by amplitude and rise time have been performed and compared in detail. Here we compared the time resolutions obtained by three digital algorithms of leading-edge, zero-crossing constant-fraction (ZC-CFD) and direct constant-fraction discriminations. Finally, we found that the best time-of-flight resolution between two PMTs can be achieved as 12 ps by the method using sample minimum for peak location and using the time-walk-resistant ZC-CFD with 4-point interpolation for timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FPGA-based trigger system for the LUX dark matter experiment

LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils resulting from interactions with dark matter particles. Signals from the detector are processed with an FPGA-based digital trigger system that analyzes the incoming data in real-time, with just a few microsecond latency. The system enables first pass selection of events of interest based on their pulse shape characteristics and 3D localization of the interactions. It has been shown to be >99% efficient in triggering on S2 signals induced by only few extracted liquid electrons. It is continuously and reliably operating since its full underground deployment in early 2013. This document is an overview of the systems capabilities, its inner workings, and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Description of a computer simulation of an orbital SAR system

In order to predict the performance of a synthetic aperture radar for a wide variety of system and environmental parameters a computer simulation of the SAR system was developed. This model is a detailed description of the SAR imaging process on a pulse-by-pulse basis. The simulation is implemented as seven computer programs for a CDC Cyber 171 digital computer.

Crow, G. L.↗

Microprocessor-based cardiotachometer

Instrument operates reliably even with stress-test electrocardiogram (ECG) signals subject to noise, baseline wandering, and amplitude change. It records heart rate from preamplified, single-lead ECG input signal and produces digital and analog heart-rate outputs which are fed elsewhere. Analog hardware processes ECG input signal, producing 10-ms pulse for each heartbeat. Microprocessor analyzes resulting pulse train, identifying irregular heartbeats and maintaining stable output during lead switching. Easily modified computer program provides analysis.

Crosier, W. G.↗

Detecting Structural Failures Via Acoustic Impulse Responses

Advanced method of acoustic pulse reflectivity testing developed for use in determining sizes and locations of failures within structures. Used to detect breaks in electrical transmission lines, detect faults in optical fibers, and determine mechanical properties of materials. In method, structure vibrationally excited with acoustic pulse (a "ping") at one location and acoustic response measured at same or different location. Measured acoustic response digitized, then processed by finite-impulse-response (FIR) filtering algorithm unique to method and based on acoustic-wave-propagation and -reflection properties of structure. Offers several advantages: does not require training, does not require prior knowledge of mathematical model of acoustic response of structure, enables detection and localization of multiple failures, and yields data on extent of damage at each location.

Bayard, David S.↗

Differential B-dot and D-dot monitors for current and voltage measurements on a 20-MA 3-MV pulsed-power accelerator.

We have developed a system of differential-output monitors that diagnose current and voltage in the vacuum section of a 20-MA 3-MV pulsed-power accelerator. The system includes 62 gauges: 3 current and 6 voltage monitors that are fielded on each of the accelerator's 4 vacuum-insulator stacks, 6 current monitors on each of the accelerator's 4 outer magnetically insulated transmission lines (MITLs), and 2 current monitors on the accelerator's inner MITL. The inner-MITL monitors are located 6 cm from the axis of the load. Each of the stack and outer-MITL current monitors comprises two separate B-dot sensors, each of which consists of four 3-mm-diameter wire loops wound in series. The two sensors are separately located within adjacent cavities machined out of a single piece of copper. The high electrical conductivity of copper minimizes penetration of magnetic flux into the cavity walls, which minimizes changes in the sensitivity of the sensors on the 100-ns time scale of the accelerator's power pulse. A model of flux penetration has been developed and is used to correct (to first order) the B-dot signals for the penetration that does occur. The two sensors are designed to produce signals with opposite polarities; hence, each current monitor may be regarded as a single detector with differential outputs. Common-mode-noise rejection is achieved by combining these signals in a 50-{Omega} balun. The signal cables that connect the B-dot monitors to the balun are chosen to provide reasonable bandwidth and acceptable levels of Compton drive in the bremsstrahlung field of the accelerator. A single 50-{omega} cable transmits the output signal of each balun to a double-wall screen room, where the signals are attenuated, digitized (0.5-ns/sample), numerically compensated for cable losses, and numerically integrated. By contrast, each inner-MITL current monitor contains only a single B-dot sensor. These monitors are fielded in opposite-polarity pairs. The two signals from a pair are not combined in a balun; they are instead numerically processed for common-mode-noise rejection after digitization. All the current monitors are calibrated on a 76-cm-diameter axisymmetric radial transmission line that is driven by a 10-kA current pulse. The reference current is measured by a current-viewing resistor (CVR). The stack voltage monitors are also differential-output gauges, consisting of one 1.8-cm-diameter D-dot sensor and one null sensor. Hence, each voltage monitor is also a differential detector with two output signals, processed as described above. The voltage monitors are calibrated in situ at 1.5 MV on dedicated accelerator shots with a short-circuit load. Faraday's law of induction is used to generate the reference voltage: currents are obtained from calibrated outer-MITL B-dot monitors, and inductances from the system geometry. In this way, both current and voltage measurements are traceable to a single CVR. Dependable and consistent measurements are thus obtained with this system of calibrated diagnostics. On accelerator shots that deliver 22 MA to a low-impedance z-pinch load, the peak lineal current densities at the stack, outer-MITL, and inner-MITL monitor locations are 0.5, 1, and 58 MA/m, respectively. On such shots the peak currents measured at these three locations agree to within 1%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance of a fast digital integrator in on-field magnetic measurements for particle accelerators

The fast digital integrator has been conceived to face most demanding magnet test requirements with a resolution of 10 ppm, a signal-to-noise ratio of 105 dB at 20 kHz, a time resolution of 50 ns, an offset of 10 ppm, and on-line processing. In this paper, the on-field achievements of the fast digital integrator are assessed by a specific measurement campaign at the European Organization for Nuclear Research (CERN). At first, the architecture and the metrological specifications of the instrument are reported. Then, the recent on-field achievements of (i) {+-}10 ppm of uncertainty in the measurement of the main field for superconducting magnets characterization, (ii) {+-}0.02 % of field uncertainty in quality assessment of small-aperture permanent magnets, and (iii) {+-}0.15 % of drift, in an excitation current measurement of 600 s under cryogenic conditions, are presented and discussed.

43 PARTICLE ACCELERATORS↗

Method for compression testing of composite materials at high strain rates

A method is presented for testing composite materials in compression at strain rates up to approximately 500 per s. The method uses a thin ring specimen (4 in. in diameter, 1 in. wide, six-eight plies thick) loaded dynamically by an external pressure pulse applied explosively through a liquid. Strains in the specimen and in a steel calibration ring are recoorded with a digital processing oscilloscope. Results are plotted by an x-y plotter in the form of a dynamic stress-strain curve. Data analysis is based on a numerical solution of the equation of motion. A computer program is used which involves smoothing and approximation of the strain magnitude, strain rate, and strain acceleration. Dynamic stress-strain curves obtained for 0-deg and 90-deg specimens of two graphite/epoxy composites are presented.

Daniel, I. M.↗

The power of event-driven analytics in Large Scale Data Processing

FeedZai is a software company specialized in creating high-­‐throughput low-­‐latency data processing solutions. FeedZai develops a product called "FeedZai Pulse" for continuous event-­‐driven analytics that makes application development easier for end users. It automatically calculates key performance indicators and baselines, showing how current performance differ from previous history, creating timely business intelligence updated to the second. The tool does predictive analytics and trend analysis, displaying data on real-­‐time web-­‐based graphics. In 2010 FeedZai won the European EBN Smart Entrepreneurship Competition, in the Digital Models category, being considered one of the "top-­‐20 smart companies in Europe". The main objective of this seminar/workshop is to explore the topic for large-­‐scale data processing using Complex Event Processing and, in particular, the possible uses of Pulse in the scope of the data processing needs of CERN. Pulse is available as open-­‐source and can be licensed both for non-­‐commercial and commercial applications. FeedZai is interested in exploring possible synergies with CERN in high-­‐volume low-­‐latency data processing applications. The seminar will be structured in two sessions, the first one being aimed to expose the general scope of FeedZai's activities, and the second focused on Pulse itself: 10:00-11:00 FeedZai and Large Scale Data Processing; Introduction to FeedZai; FeedZai Pulse and Complex Event Processing; Demonstration; Use-Cases and Applications; Conclusion and Q&A. 11:00-11:15 Coffee break 11:15-12:30 FeedZai Pulse Under the Hood; A First FeedZai Pulse Application; PulseQL overview; Defining KPIs and Baselines; Conclusion and Q&A. About the speakers Nuno Sebastião is the CEO of FeedZai. Having worked for many years for the European Space Agency (ESA), he was responsible the overall design and development of Satellite Simulation Infrastructure of the agency. Having left ESA to found FeedZai, Nuno is currently responsible for the whole operations of the company. Nuno holds an M.Eng. in Informatics Engineering for the University of Coimbra, and an MBA from the London Business School. Paulo Marques is the CTO of FeedZai, being responsible for product development. Paulo is an Assistant Professor at the University of Coimbra, in the area of Distributed Data Processing, and an Adjunct Associated Professor at Carnegie Mellon, in the US. In the past Paulo lead a large number of projects for institutions like the ESA, Microsoft Research, SciSys, Siemens, among others, being now fully dedicated to FeedZai. Paulo holds a Ph.D. in Distributed Systems from the University of Coimbra.

97 MATHEMATICS AND COMPUTING↗