Search NASA⌕ Search

SEARCH · Search NASA

Results for “digital reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Computational Approaches to Vestibular Research

The Biocomputation Center at NASA Ames Research Center is dedicated to a union between computational, experimental and theoretical approaches to the study of neuroscience and of life sciences in general. The current emphasis is on computer reconstruction and visualization of vestibular macular architecture in three-dimensions (3-D), and on mathematical modeling and computer simulation of neural activity in the functioning system. Our methods are being used to interpret the influence of spaceflight on mammalian vestibular maculas in a model system, that of the adult Sprague-Dawley rat. More than twenty 3-D reconstructions of type I and type II hair cells and their afferents have been completed by digitization of contours traced from serial sections photographed in a transmission electron microscope. This labor-intensive method has now been replace d by a semiautomated method developed in the Biocomputation Center in which conventional photography is eliminated. All viewing, storage and manipulation of original data is done using Silicon Graphics workstations. Recent improvements to the software include a new mesh generation method for connecting contours. This method will permit the investigator to describe any surface, regardless of complexity, including highly branched structures such as are routinely found in neurons. This same mesh can be used for 3-D, finite volume simulation of synapse activation and voltage spread on neuronal surfaces visualized via the reconstruction process. These simulations help the investigator interpret the relationship between neuroarchitecture and physiology, and are of assistance in determining which experiments will best test theoretical interpretations. Data are also used to develop abstract, 3-D models that dynamically display neuronal activity ongoing in the system. Finally, the same data can be used to visualize the neural tissue in a virtual environment. Our exhibit will depict capabilities of our computational approaches and some of our findings from their application. For example, our research has demonstrated that maculas of adult mammals retain the property of synaptic plasticity. Ribbon synapses increase numerically and undergo changes in type and distribution (p<0.0001) in type II hair cells after exposure to microgravity for as few as nine days. The finding of macular synaptic plasticity is pertinent to the clinic, and may help explain some. balance disorders in humans. The software used in our investigations will be demonstrated for those interested in applying it in their own research.

Ross, Muriel D.↗

Hierarchical reconstruction of 3D well-connected porous media from 2D exemplars using statistics-informed neural network

The relationships between porous microstructures and transport properties are of fundamental importance in various scientific and engineering applications. Due to the intricacy, stochasticity and heterogeneity of porous media, reliable characterization and modeling of transport properties often require a complete dataset of internal microstructure samples. However, it is often an unbearable cost to acquire sufficient 3D digital microstructures by purely using microscopic imaging systems. Herein this paper presents a machine learning-based technique to hierarchically reconstruct 3D well-connected porous microstructures from one isotropic or several anisotropic low-cost 2D exemplar(s). To compactly characterize the large-scale microstructural features, a Gaussian image pyramid is built for each 2D exemplar. Local morphology patterns are collected from the Gaussian image pyramids, and then they serve as the training data to embed the 2D morphological statistics into feed-forward neural networks at multiple length levels. By using a specially-developed morphology integration scheme, the 3D morphological statistics at different levels can be inferred from the statistics-informed neural networks. Gibbs sampling is adopted to hierarchically reconstruct 3D microstructures by using multi-level 3D morphological statistics, where the large-scale, regional and local morphological patterns are statistically generated and successively added to the same 3D random field. The proposed method is tested on a series of porous media with distinct morphologies, and the statistical equivalence between the reconstructed and the real microstructures is systematically evaluated by comparing morphological descriptors and transport properties. The results demonstrate that the proposed 2D-to-3D microstructure reconstruction method is a universal and efficient approach to generating morphologically and physically realistic samples of porous media.

42 ENGINEERING↗

From observation to replication: machine-learning-driven quantification and replication of fine-scale fish kinematics and behavior

Long-term quantification of fish behavior is essential for aquatic ecology, wildlife telemetry, and biomechanical device development. However, the observation duration required to obtain reliable behavioral and kinematic metrics remains unclear, and few tools exist to physically reproduce natural swimming motion for controlled experimentation. We address these challenges by developing a generalizable framework that models behavioral reliability (Spearman–Brown reliability index) as a function of observation duration and derives metric-specific monitoring thresholds. Using juvenile white sturgeon (Acipenser transmontanus) as a case study, we demonstrate that the minimum duration needed for reliable estimates varies substantially across kinematic features: to exceed a reliability of 0.8, total distance traveled requires 12 days, average curvature (mm?¹) 15 days, tail-beat frequency (Hz) 8 days, and average speed (body length/s) 17 days. We further bridge digital analysis and physical testing by developing a hardware-in-the-loop simulator that reconstructs machine-learning-derived swimming kinematics with high fidelity (correlation coefficient 0.98–0.99, RMSE 1.22–1.27 mm over a 5-minute segment). This platform enables realistic, repeatable motion stimuli for evaluating aquatic sensing technologies and bio-integrated devices under controlled conditions. Together, these contributions provide a scalable approach for designing long-term behavioral studies and a data-driven connection between ecological observation and robotic experimentation.

Hwang, SungJoo↗

Image improvement and three-dimensional reconstruction using holographic image processing

Holographic computing principles make possible image improvement and synthesis in many cases of current scientific and engineering interest. Examples are given for the improvement of resolution in electron microscopy and 3-D reconstruction in electron microscopy and X-ray crystallography, following an analysis of optical versus digital computing in such applications.

Stroke, G. W.↗

Modeling the Effective Elasticity of Anisotropic Porous Materials

The development and optimization of composite materials designed for thermal protection of NASA’s spacecraft require understanding their physical response to high-enthalpy environments. To predict their macro-scale properties and behavior, high-fidelity 3D simulations are performed at the microscale on realistic representations of these composites. The digital microstructures are generated either synthetically or through X-ray micro-computed tomography reconstructions. One of the main challenges in the prediction of the structural response of heatshield materials is the computation of the effective elasticity of the fibrous composite, as well as the understanding of the deformation and stresses generated at the microscale. These are driven by the fiber layout within the microstructure and the distribution of the infused matrix. In this effort, the micro-mechanical linear elastic behavior of fibrous ablators is modeled using a numerical method based on the Multi-Point Stress Approximation (MPSA) finite volume scheme, a generalization of the more commonly used Multi-Point Flux Approximation (MPFA) that was presented at the 10th Ablation Workshop. To predict the behavior of fibrous and woven architectures, algorithms that compute the local fiber orientation are used. The implementation of the MPSA was verified using analytical solutions, engineering test cases, and compared against legacy Finite Element Analysis (FEA) software. The stress analysis models were then applied to real geometries used by NASA in thermal protection systems such as fibrous preforms and woven materials and the results were compared to experimental data.

Elasticity↗

Laboratory-Based Micro-X-ray Computed Tomography of Energy Materials at Idaho National Laboratory

Abstract The Idaho National Laboratory (INL) has implemented laboratory-based micro-X-ray computed tomography in a laboratory equipped for the examination of highly radioactive samples. This capability provides nondestructive three-dimensional volumetric information on samples to inform subsequent traditional destructive examinations as well as real-world inputs for high-fidelity scientific modeling. Samples can be imaged with spatial resolutions ranging from several hundred nm/voxel up to ~ 100 µm/voxel. The best usable spatial resolution achieved to date is 384 nm/voxel with this instrument, while the highest radiological dose rate of a sample imaged is ~ 60 R/h β/γ on contact. Advanced data analysis, including custom tomographic reconstruction and segmentation methods, have also been developed to support this capability. In addition to traditional digital X-ray radiography and tomography, this instrument is also able to visualize in situ tensile and compression testing as well as perform diffraction contrast tomography. This work describes the X-ray computed tomography post-irradiation examination capabilities at INL, as well as detailing a variety of applications this instrument has examined.

36 MATERIALS SCIENCE↗

Conceptual issues of softcopy photogrammetric workstations

A conceptual approach to digital photogrammetry is presented. Automation of photogrammetric processes on digital photogrammetric workstations is considered with particular attention given to the automatic orientation and the surface reconstruction module. It is suggested that major progress toward autonomous softcopy workstations depends more on advances on the conceptual level rather than on refinement of system components such as hardware and algorithms.

Schenk, Toni↗

Computing the effective elasticity of anisotropic porous media from X-ray computed micro-tomography images

Development and optimization of composite materials designed for thermal protection of NASA’s spacecraft requires the understanding of their physical response to high-enthalpy environments. To predict their macro-scale properties and behavior, high-fidelity 3D simulations are performed at the micro-scale on realistic representations of these composites. The digital micro-structures are generated either synthetically or through X-ray micro-tomography reconstructions. One of the main challenges in the prediction of heatshield material structural response is the computation of the effective elasticity of the fibrous composite, as well as the understanding of the deformation and stresses generated at the micro-scale. These are driven by the fiber layout within the micro-structure and the distribution of the infused matrix. In this effort, the micro-mechanical linear elastic behavior of fibrous ablators is modeled through the use of a numerical method based on the Multi-Point Stress Approximation (MPSA) finite volume scheme. The MPSA, a generalization of the more commonly used Multi-Point Flux Approximation (MPFA), was discussed in a previous presentation at the 15th USCCN and in reference. To predict the behavior of fibrous and woven architectures, algorithms that compute the local fiber orientation are used. The implementation of the MPSA was verified using analytical solutions, engineering test cases and compared against legacy Finite Element Analysis (FEA) software. The stress analysis models were then applied to real geometries used by NASA in thermal protection systems such as fibrous preforms and woven materials and the results were compared to experimental data.

Federico Semeraro↗

GPS-Based Precision Baseline Reconstruction for the TanDEM-X SAR-Formation

The TanDEM-X formation employs two separate spacecraft to collect interferometric Synthetic Aperture Radar (SAR) measurements over baselines of about 1 km. These will allow the generation ofa global Digital Elevation Model (DEM) with an relative vertical accuracy of 2-4 m and a 10 m ground resolution. As part of the ground processing, the separation of the SAR antennas at the time of each data take must be reconstructed with a 1 mm accuracy using measurements from two geodetic grade GPS receivers. The paper discusses the TanDEM-X mission as well as the methods employed for determining the interferometric baseline with utmost precision. Measurements collected during the close fly-by of the two GRACE satellites serve as a reference case to illustrate the processing concept, expected accuracy and quality control strategies.

Montenbruck, O.↗

Time calibration and synchronization of the scintillation light detection system in ICARUS-T600

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently taking data in the Short Baseline Neutrino (SBN) program at Fermilab (U.S.A.) to search for a possible LSND-like sterile neutrino signal at Δm 2 ≈ 1 eV 2 with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced by the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths installation, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of genuine neutrino interactions. The correct time reconstruction of events requires the precise knowledge of the delay of each PMT channel and a good synchronization of recording electronics, this last based on fast sampling digitizers. To achieve a time resolution better than 1 ns, we perform three consecutive timing corrections deployed at different stages of the optical data flow. Results demonstrate the capability of the ICARUS-T600 light detection system to allow a precise reconstruction of the temporal evolution of each event occurring in the detector and the association of neutrino events with the bunched structure of BNB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pulse Vector-Excitation Speech Encoder

Proposed pulse vector-excitation speech encoder (PVXC) encodes analog speech signals into digital representation for transmission or storage at rates below 5 kilobits per second. Produces high quality of reconstructed speech, but with less computation than required by comparable speech-encoding systems. Has some characteristics of multipulse linear predictive coding (MPLPC) and of code-excited linear prediction (CELP). System uses mathematical model of vocal tract in conjunction with set of excitation vectors and perceptually-based error criterion to synthesize natural-sounding speech.

Davidson, Grant↗

Determination of the implementation of the 3-axis attitude motion simulator digital position controller

The digital position controller implemented in the control computer of the 3-axis attitude motion simulator is mathematically reconstructed and documented, since the information supplied with the executable code of this controller was insufficient to make substantial modifications to it. Also developed were methodologies to introduce changes in the controller which do not require rewriting the software. Finally, recommendations are made on possible improvement to the control system performance.

Magana, Mario E.↗

The EGRET high energy gamma ray telescope

The Energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory (GRO) is sensitive in the energy range from about 20 MeV to about 30,000 MeV. Electron-positron pair production by incident gamma photons is utilized as the detection mechanism. The pair production occurs in tantalum foils interleaved with the layers of a digital spark chamber system; the spark chamber records the tracks of the electron and positron, allowing the reconstruction of the arrival direction of the gamma ray. If there is no signal from the charged particle anticoincidence detector which surrounds the upper part of the detector, the spark chamber array is triggered by two hodoscopes of plastic scintillators. A time of flight requirement is included to reject events moving backward through the telescope. The energy of the gamma ray is primarily determined by absorption of the energies of the electron and positron in a 20 cm deep NaI(Tl) scintillator.

Hartman, R. C.↗

Performance Assessment of Different Pulse Reconstruction Algorithms for the ATHENA X-Ray Integral Field Unit

The X-ray Integral Field Unit (X-IFU) microcalorimeter, on-board Athena, with its focal plane comprising 3840 Transition Edge Sensors (TESs) operating at 90 mK, will provide unprecedented spectral-imaging capability in the 0.2-12 keV energy range. It will rely on the on-board digital processing of current pulses induced by the heat deposited in the TES absorber, as to recover the energy of each individual events. Assessing the capabilities of the pulse reconstruction is required to understand the overall scientific performance of the X-IFU, notably in terms of energy resolution degradation with both increasing energies and count rates. Using synthetic data streams generated by the X-IFU End-to-End simulator, we present here a comprehensive benchmark of various pulse reconstruction techniques, ranging from standard optimal filtering to more advanced algorithms based on noise covariance matrices. Beside deriving the spectral resolution achieved by the different algorithms, a first assessment of the computing power and ground calibration needs is presented. Overall, all methods show similar performances, with the reconstruction based on noise covariance matrices showing the best improvement with respect to the standard optimal filtering technique. Due to prohibitive calibration needs, this method might however not be applicable to the X-IFU and the best compromise currently appears to be the so-called resistance space analysis which also features very promising high count rate capabilities.

microcalorimeters↗

Super Resolution Digital Image Correlation (SR-DIC): an Alternative to Image Stitching at High Magnifications

Abstract Background High-resolution Digital Image Correlation (DIC) measurements have previously been produced by stitching of neighboring images, which often requires short working distances. Separately, the image processing community has developed super resolution (SR) imaging techniques, which improve resolution by combining multiple overlapping images. Objective This work investigates the novel pairing of super resolution with digital image correlation, as an alternative method to produce high-resolution full-field strain measurements. Methods First, an image reconstruction test is performed, comparing the ability of three previously published SR algorithms to replicate a high-resolution image. Second, an applied translation is compared against DIC measurement using both low- and super-resolution images. Third, a ring sample is mechanically deformed and DIC strain measurements from low- and super-resolution images are compared. Results SR measurements show improvements compared to low-resolution images, although they do not perfectly replicate the high-resolution image. SR-DIC demonstrates reduced error and improved confidence in measuring rigid body translation when compared to low resolution alternatives, and it also shows improvement in spatial resolution for strain measurements of ring deformation. Conclusions Super resolution imaging can be effectively paired with Digital Image Correlation, offering improved spatial resolution, reduced error, and increased measurement confidence.

Hansen, R. S.↗

Slip localization behavior at triple junctions in nickel-base superalloys

Incipient slip localization in the vicinity of hundreds of grain boundary triple junctions (TJs) in a lightly deformed nickel-base superalloy IN718 is studied using a combination of three-dimensional (3D) crystal plasticity finite element (CPFE) modeling, high resolution digital image correlation (HR-DIC) and 3D electron back-scatter diffraction tomography (3D EBSD). A 3D reconstruction method enables identification of thousands of TJs and correspondence of any observed slip bands with their originating TJ lines below the specimen surface. Here, we present a large-scale CPFE model of the experimental 3D microstructure composed of high-fidelity representation of the TJ lines and the boundaries and interiors of the parent grains and use it to calculate the local micromechanical response and slip activity of all TJs at the onset of macroscopic yielding. Statistical analysis of the calculated quantities reveal TJs develop larger stress concentration and grain-average re-orientation than grain interiors and grain boundaries, however no substantial differences in cumulative slip were found among these microstructural regions. We find that TJs with observed slip bands generate lower grain-average re-orientation, fewer active slip systems, and more localized slip on a single system than those without. The distinctions in the reorientation and slip activity are stronger in TJs that experience more intense slip.

36 MATERIALS SCIENCE↗

Third order digital-to-analog converter

System, consisting of sample and hold digital-to-analog converter, clock circuit, sample delay circuit, initial condition circuit and interpolator circuit, improves accuracy of reconstructed analog signal without increasing sample rates.

Dotson, W. P.↗

The automation of the stellar proper motion survey

A microdensitometer, scanning pairs of star plates of identical areas of the sky taken a decade apart, is coupled to a magnetic tape unit through a data acquisition system. This system performs an image density threshold level selection for each plate and a buffer memory system to smooth the data flow as well as analog and digital display controls. The data from the tape are processed later by a large scale high speed computer which reconstructs the scanned images, discovers, measures, and documents stellar proper motions by precise comparison of corresponding areas of the two star plates to detect those images which have moved at least 0.10 seconds annually in the time interval between the exposures.

Newcomb, J. S.↗