Search NASA⌕ Search

SEARCH · Search NASA

Results for “directional cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Aircraft electric motor with integrated cooling system

Aircraft electric motors include a motor unit having a rotor and a stator. The stator includes a plurality of windings and cooling channels arranged to provide cooling thereto. A drive unit is configured to drive operation of the motor unit. A cooling system includes a working fluid arranged within a cooling fluid flow path, wherein the cooling fluid flow path includes a liquid cooling path configured to direct flow of the working fluid through, at least, the cooling channels of the motor unit and a vapor cooling path configured to direct flow of the working fluid through the drive unit and a separator arranged upstream of each of the liquid cooling path and the vapor cooling path and configured to direct a liquid portion of the working fluid into the liquid cooling path and configured to direct a vapor portion of the working fluid into the vapor cooling path.

Alahyari, Abbas A.↗

Direct numerical simulations of turbulent premixed cool flames: Global and local flame dynamics analysis

The cool flame dynamics, especially in turbulent flows, is of great interest for both practical application and fundamental research. Here, in this study, a series of direct numerical simulations of turbulent premixed n-C 7 H 16 /O 2 /O 3 /N 2 cool flames are performed, with the focus on the influence of turbulence intensity (u'/S L , where S L is the laminar flame speed) on the flame structure as well as the global and local cool flame dynamics. It is found that the cool flame front is considerably wrinkled by turbulence at high u'/S L , leading to significantly thickened turbulent cool flame brush and largely altered local reactivity compared with the reference laminar flame. However, the turbulent flame structure in the temperature space is found to be insensitive to u'/S L . Besides, with increasing u'/S L , the normalized turbulent cool flame speed (S L /S L ) is monotonically increased, attributed to substantial augmentation on the flame surface area (A T /A L ), while the stretching factor (I 0 ) remains almost constant and is smaller than 1. The underlying mechanisms for such variations are revealed through local flame dynamics analysis. Specifically, the local flame displacement speed S d is found to be strongly negatively correlated with flame curvature; meanwhile, such negative correlation and the probability distribution function (PDF) of flame curvature are barely influenced by u'/S L , leading to a weak dependence of I 0 on u'/S L . In contrast, the PDF of the tangential strain rate is found to span a much wider range and shift to the positive side as u'/S L increases, suggesting that the enhanced tangential strain rate is the main cause for the increase in surface area of the turbulent premixed cool flame. Finally, the influence of equivalence ratio on above findings is found to be insignificant, indicating that although the local reactivity of turbulent premixed cool flames is altered due to the differential diffusion, the resultant flame- stretch interaction is insensitive to the equivalence ratio. This study presents some unique cool flame dynamics that are distinct from hot flames, which can help improve the understanding and modeling of turbulent cool flames.

Cool flames↗

High sensitivity real-time NVR monitor

A real time non-volatile residue (NVR) monitor, which utilizes surface acoustic wave (SAW) resonators to detect molecular contamination in a given environment. The SAW resonators operate at a resonant frequency of approximately 200 MHz-2,000 MHz which enables the NVR monitor to detect molecular contamination on the order of 10.sup.-11 g-cm.sup.-2 to 10.sup.-13 g-cm.sup.2. The NVR monitor utilizes active temperature control of (SAW) resonators to achieve a stable resonant frequency. The temperature control system of the NVR monitor is able to directly heat and cool the SAW resonators utilizing a thermoelectric element to maintain the resonators at a present temperature independent of the environmental conditions. In order to enable the direct heating and cooling of the SAW resonators, the SAW resonators are operatively mounted to a heat sink. In one embodiment, the heat sink is located in between the SAW resonators and an electronic circuit board which contains at least a portion of the SAW control electronics. The electrical leads of the SAW resonators are connected through the heat sink to the circuit board via an electronic path which prevents inaccurate frequency measurement.

Bowers, William D.↗

Heat transfer distribution on a discontinuously convective cooled surface

An active cooling scheme in which discrete cooling passages are used was investigated. In this scheme, the coolant passages are placed perpendicular to the main stream direction. Streamwise temperature oscillations result from the highly cooled regions, near the coolant channels, being next to regions not directly cooled between the channels. The accuracy of the heat transfer rate predictions by these approximations was evaluated by means of both experimental and numerical investigations. Experiments were conducted at free stream Mach number of 6 with several cooling passages. Heat transfer measurements were made and corresponding theoretical analysis were performed for comparison in evaluating both local and overall deviations in the heat transfer rate.

Piva, R.↗

A direct-interface, fusible heat sink for astronaut cooling

Astronaut cooling during extravehicular activity is a critical design issue in developing a portable life support system that meets the requirements of a space station mission. Some of the requirements are that the cooling device can be easily regenerable and nonventing during operation. In response to this, a direct-interface, fusible heat sink prototype with freezable quick-disconnects was developed. A proof-of-concept prototype was constructed and tested that consists of an elastic container filled with normal tap water and having two quick-disconnects embedded in a wall. These quick-disconnects are designed so that they may be frozen with the ice and yet still be joined to the cooling system, allowing an immediate flow path. The inherent difficulties in a direct-interface heat sink have been overcome, i.e., (1) establishing an initial flow path; (2) avoiding low-flow freeze-up; and (3) achieving adequate heat-transfer rates at the end of the melting process. The requirements, design, fabrication, and testing are discussed.

Lomax, Curtis↗

A direct-interface fusible heat sink for astronaut cooling

Astronaut cooling during extravehicular activity is a critical design issue in developing a portable life support system that meets the requirements of a space station mission. Some the requirements are that the cooling device can be easily regenerable and nonventing during operation. In response to this, a direct-interface, fusible heat sink prototpye with freezable quick-disconnects was developed. A proof-of-concept prototype was constructed and tested that consists of an elastic container filled with normal tap water and having two quick-disconnects embedded in a wall. These quick-disconnects are designed so that they may be frozen with the ice and yet still be joined to the cooling system, allowing an immediate flow path. The inherent difficulties in a direct-interface heat sink have been overcome, i.e., (1) establishing an initial flow path; (2) avoiding low-flow freeze-up; and (3) achieving adequate heat-transfer rates at the end of the melting process. The requirements, design, fabrication, and testing are discussed.

Lomax, Curtis↗

Effects of stratification and charge cooling on combustion in a gasoline direct-injection compression ignition (GDCI) engine

With the development of low temperature engine combustion strategies, performance of gasoline-type fuels under compression ignition conditions has attracted extensive research interest. Meanwhile, for the sake of co-optimization of engines and fuels for future ground transportation, identification and evaluation of general fuel properties should be a core research priority instead of endless testing of specific fuels. In this study, the roles of fuel octane sensitivity in characterizing the ignition performance of gasoline surrogates have been systematically investigated under typical gasoline direct ignition compression ignition (GDCI) engine conditions using 3D combustion CFD simulation, especially considering the subsequent in-cylinder charge stratification and charge cooling. Two different operating conditions, high boost pressure low boost temperature (beyond-RON) case and low boost pressure high boost temperature (beyond-MON) case, were considered. By comparing with our previous zero-dimensional chemical kinetic study of gasoline surrogates in advanced compression ignition (ACI) engines, the effects of stratification and charge cooling on the combustion processes are investigated. It is found that different fuel octane sensitivities lead to slight difference in equivalence ratio stratification and charge cooling due to differences in volatility. However, fuel reactivity is still the more dominant factor than the stratification and charge cooling effects in determining combustion phasing. The present results help to justify the P-T domain framework for engine autoignition analysis of overlapping pressure-temperature trajectory with ignition delay iso-contour. Here, the results also provide useful guidance to the understanding of GCI combustion process, and to the evaluation of controlling fuel properties and the selection of alternative fuels in GCI engines.

33 ADVANCED PROPULSION SYSTEMS↗

Modeling the Influences of Aerosols on Pre-Monsoon Circulation and Rainfall over Southeast Asia

We conduct several sets of simulations with a version of NASA's Goddard Earth Observing System, version 5, (GEOS-5) Atmospheric Global Climate Model (AGCM) equipped with a two-moment cloud microphysical scheme to understand the role of biomass burning aerosol (BBA) emissions in Southeast Asia (SEA) in the pre-monsoon period of February-May. Our experiments are designed so that both direct and indirect aerosol effects can be evaluated. For climatologically prescribed monthly sea surface temperatures, we conduct sets of model integrations with and without biomass burning emissions in the area of peak burning activity, and with direct aerosol radiative effects either active or inactive. Taking appropriate differences between AGCM experiment sets, we find that BBA affects liquid clouds in statistically significantly ways, increasing cloud droplet number concentrations, decreasing droplet effective radii (i.e., a classic aerosol indirect effect), and locally suppressing precipitation due to a deceleration of the autoconversion process, with the latter effect apparently also leading to cloud condensate increases. Geographical re-arrangements of precipitation patterns, with precipitation increases downwind of aerosol sources are also seen, most likely because of advection of weakly precipitating cloud fields. Somewhat unexpectedly, the change in cloud radiative effect (cloud forcing) at surface is in the direction of lesser cooling because of decreases in cloud fraction. Overall, however, because of direct radiative effect contributions, aerosols exert a net negative forcing at both the top of the atmosphere and, perhaps most importantly, the surface, where decreased evaporation triggers feedbacks that further reduce precipitation. Invoking the approximation that direct and indirect aerosol effects are additive, we estimate that the overall precipitation reduction is about 40% due to the direct effects of absorbing aerosols, which stabilize the atmosphere and reduce surface latent heat fluxes via cooler land surface temperatures. Further refinements of our two-moment cloud microphysics scheme are needed for a more complete examination of the role of aerosol-convection interactions in the seasonal development of the SEA monsoon.

SE Asia Monsoon↗

Pilgrim Hot Springs: GEOPHIRES Inputs and Outputs for Direct-Use Geothermal District Heating and Cooling

This dataset includes files for a techno-economic analysis conducted using the GEOPHIRES simulator to examine the feasibility of expanding a larger district heating site in a remote location: Pilgrim Hot Springs, Alaska. Files included here are GEOPHIRES inputs and outputs for five different scenarios with varying demand, cycle, and system design characteristics to analyze. Also included is the link to the GEOPHIRES GitHub, as well as a link to the dataset that contains the energy modelling used to determine the heating demand for the district. For a list of the differences between scenarios, see the included "Input Overview.txt" file. Fields included in the input files are: subsurface technical parameters, surface technical parameters, financial parameters, capital and O&M parameters, as well as simulation parameters. The output files are case reports that summarize all equipment, reservoir characteristics, costs, and heating profiles.

15 GEOTHERMAL ENERGY↗

Stochastic scheduling for commercial building cooling systems: considering uncertainty in zone temperature prediction

Here, this paper presents the first attempt to address the uncertainty in zone temperature prediction with stochastic optimization. The uncertain zone temperature is a process uncertainty and has not been considered in the existing stochastic optimization for building control. To fill this gap, we proposed a novel formulation of stochastic optimization to handle process uncertainty in building control. Specifically, we first examined the accuracy of a typical linear model for predicting zone temperature. We then formulated the scheduling of the building cooling system as a stochastic optimization problem over a 24-hour look-ahead period to minimize the electricity cost of the studied building cooling system. After that, we applied the proposed stochastic load scheduling (SLS) to a direct expansion (DX) cooling system that serves a medium office building. Through simulation with a detailed building energy simulation software, EnergyPlus, we evaluated the operational cost and the thermal comfort compared with a deterministic load scheduling. The operation cost of scheduling was found to vary with the level of zone temperature prediction uncertainty. The proposed SLS can mitigate the impacts of uncertain zone temperature predictions on both operational cost and thermal comfort. The evaluation results indicate that the proposed SLS works better when the uncertainty level is more significant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MEMS Device Being Developed for Active Cooling and Temperature Control

High-capacity cooling options remain limited for many small-scale applications such as microelectronic components, miniature sensors, and microsystems. A microelectromechanical system (MEMS) is currently under development at the NASA Glenn Research Center to meet this need. It uses a thermodynamic cycle to provide cooling or heating directly to a thermally loaded surface. The device can be used strictly in the cooling mode, or it can be switched between cooling and heating modes in milliseconds for precise temperature control. Fabrication and assembly are accomplished by wet etching and wafer bonding techniques routinely used in the semiconductor processing industry. Benefits of the MEMS cooler include scalability to fractions of a millimeter, modularity for increased capacity and staging to low temperatures, simple interfaces and limited failure modes, and minimal induced vibration.

Moran, Matthew E.↗

Cooling rate and dendrite spacing control in direct metal deposition printed Cu-Fe alloys

Over the last several decades, additive manufacturing (AM) has been primarily used for rapid prototyping or to create novel geometries that would be difficult or impossible to create by normal manufacturing methods. More recently, research has been focused on expanding the list of materials that can be made through additive manufacturing, opening a greater range of material properties for this manufacturing method. Due to the unusual conditions during AM, including the high cooling rates and voxel by voxel method of production, AM parts often have anisotropic material microstructures and properties. In this investigation, the laser power, composition, and nozzle head speed during direct metal deposition of copper-iron alloys was varied to understand how the grain structure within the printed parts could be changed and controlled. The resulting dendrite spacing was measured and compared to calculated cooling rates from Gaussian beams on flat plates under similar material and laser properties, which resulted in a cooling rate to dendrite spacing relationship following an inverse square root, as is found in other dendritic systems [Young and Kerkwood, Metall. Trans. A 6, 197–205 (1975)]. Thus, it is demonstrated that in the Cu-Fe system, dendrite spacing can be controlled through manipulation of printing parameters.

36 MATERIALS SCIENCE↗

Curved film cooling admission tube

Effective film cooling to protect a wall surface from a hot fluid which impinges on or flows along the surface is provided. A film of cooling fluid having increased area is provided by changing the direction of a stream of cooling fluid through an angle of from 135 deg. to 165 deg. before injecting it through the wall into the hot flowing gas. The 1, cooling fluid is injected from an orifice through a wall into a hot flowing gas at an angle to form a cooling fluid film. Cooling fluid is supplied to the orifice from a cooling fluid source via a turbulence control passageway having a curved portion between two straight portions. The angle through which the direction of the cooling fluid is turned results in less mixing of the cooling fluid with the hot gas, thereby substantially increasing the length of the film in a downstream direction.

Graham, R. W.↗

Design and Development of a Fluid Immersion Cooled, SiC MOSFET, 37.5 kW, Bi-Directional Motor Converter

NASA's SUb-sonic Single Aft eNgine (SUSAN) aircraft is a concept aircraft whose architecture is that of a subsonic regional jet transport aircraft. SUSAN contains a single turbofan engine coupled to an electrified aircraft propulsion (EAP) system. To provide a path towards this goal, a 25% scale version of the SUSAN aircraft is being researched. A main component of the 25% power train is the Motor And Generator Intelligent Converter (MAGIC). This paper presents the design, development, and initial test results from MAGIC, a 37.5 kW, fluid immersion cooled, silicon carbide (SiC) MOSFET-based, bi-directional converter and controller.

PAO↗

Design and Development of a Fluid Immersion Cooled, SiC MOSFET, 37.5 kW, Bi-Directional Motor Converter

NASA's SUb-sonic Single Aft eNgine (SUSAN) aircraft is a concept aircraft whose architecture is that of a subsonic regional jet transport aircraft. SUSAN contains a single turbofan engine coupled to an electrified aircraft propulsion (EAP) system. To provide a path towards this goal, a 25% scale version of the SUSAN aircraft is being researched. A main component of the 25% power train is the Motor And Generator Intelligent Converter (MAGIC). This paper presents the design, development, and initial test results from MAGIC, a 37.5 kW, fluid immersion cooled, silicon carbide (SiC) MOSFET-based, bi-directional converter and controller.

Immersion↗