Search NASA⌕ Search

SEARCH · Search NASA

Results for “directional discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Fundamental benchmarking of the discharge properties of negative electrodes in lead acid batteries

The unprecedented scale of energy storage deployment needed to allow high penetration of intermittent renewable energy sources into the electrical grid places significant economic cost and performance targets on battery technologies. Lead batteries, owing to their highly abundant and inexpensive raw materials, can be considered an important solution to grid storage as long as they achieve high material utilization, fast recharge rates, and long cycle life. To address the limitations in material utilization, we need to revisit the electrochemical processes during the discharge step and answer the following question: what are the fundamental limits of the discharge reaction? In this work we discuss how well-defined lead metal surfaces with nanometer scale roughness allow us to resolve the accessible discharge capacity for both faradaic and non-faradaic processes as a function of electrolyte concentration and in the presence of traditional additives. The direct connection between PbSO 4 layer morphology and discharge rates gives us important insights on the mechanism of discharge as related to the dissolution and passivation events. In conclusion, this work sets the stage for reimagining the design of lead batteries with implications to grid storage applications.

25 ENERGY STORAGE↗

Optimization of simulated high-field side lower hybrid current drive coupling using machine learning predictions of scrape-off layer density

Lower hybrid current drive (LHCD) is a potential source of non-inductive off-axis current drive (CD) for tokamaks. Although LHCD has been successfully deployed on a number of tokamaks, it is highly sensitive to the scrape-off layer (SOL) conditions local to the LHCD launcher. Large gaps between the launcher and plasma core, SOL turbulence, or edge density perturbations due to edge-localized modes can hamper CD or cause large reflected power. These coupling issues in part motivated the installation of an LHCD launcher on the high-field side (HFS) of DIII-D. On the HFS, the SOL is less turbulent and more controllable compared to the low-field side. This quiescence may result in more predictable edge conditions and thus a more predictable CD. Here, in this work, HFS SOL reflectometry measurements are predicted from global plasma parameters using machine learning models. The SOL predictions coupled with the full-wave simulation of the LHCD launcher allow for the prediction of reflected power, directivity, and arcing risk before the discharge. Launcher performance is then optimized using multi-objective Bayesian optimization, finding the shot parameters that result in an optimal SOL density that maximizes CD while minimizing the risk of arcing. The predictions and optimizations of LHCD performance are then accelerated using a surrogate model of the full-wave LHCD simulation.

Bayesian optimization↗

Hyperfine structure and isotope shifts of transitions in neutral and singly ionized ytterbium

The present experimental investigation of the hyperfine structure and isotopic shifts of transitions in neutral and singly-ionized Yb, which constitute a system of some interest to microwave-frequency standards, used counterpropagating pump and probe laser beams directed through a hollow-cathode discharge lamp. The results obtained are in agreement with previous measurements except in the case of the Yb-173(+) 6 2P0 sub 3/2 state, which is more accurately determined.

Berends, R. W.↗

Effect of Correlated Precision Errors on Uncertainty of a Subsonic Venturi Calibration

An uncertainty analysis performed in conjunction with the calibration of a subsonic venturi for use in a turbine test facility produced some unanticipated results that may have a significant impact in a variety of test situations. Precision uncertainty estimates using the preferred propagation techniques in the applicable American National Standards Institute/American Society of Mechanical Engineers standards were an order of magnitude larger than precision uncertainty estimates calculated directly from a sample of results (discharge coefficient) obtained at the same experimental set point. The differences were attributable to the effect of correlated precision errors, which previously have been considered negligible. An analysis explaining this phenomenon is presented. The article is not meant to document the venturi calibration, but rather to give a real example of results where correlated precision terms are important. The significance of the correlated precision terms could apply to many test situations.

Hudson, S. T.↗

Experimental Investigation of a Direct-drive Hall Thruster and Solar Array System at Power Levels up to 10 kW

As NASA considers future exploration missions, high-power solar-electric propulsion (SEP) plays a prominent role in achieving many mission goals. Studies of high-power SEP systems (i.e. tens to hundreds of kilowatts) suggest that significant mass savings may be realized by implementing a direct-drive power system, so NASA recently established the National Direct-Drive Testbed to examine technical issues identified by previous investigations. The testbed includes a 12-kW solar array and power control station designed to power single and multiple Hall thrusters over a wide range of voltages and currents. In this paper, single Hall thruster operation directly from solar array output at discharge voltages of 200 to 450 V and discharge powers of 1 to 10 kW is reported. Hall thruster control and operation is shown to be simple and no different than for operation on conventional power supplies. Thruster and power system electrical oscillations were investigated over a large range of operating conditions and with different filter capacitances. Thruster oscillations were the same as for conventional power supplies, did not adversely affect solar array operation, and were independent of filter capacitance from 8 to 80 ?F. Solar array current and voltage oscillations were very small compared to their mean values and showed a modest dependence on capacitor size. No instabilities or anomalous behavior were observed in the thruster or power system at any operating condition investigated, including near and at the array peak power point. Thruster startup using the anode propellant flow as the power 'switch' was shown to be simple and reliable with system transients mitigated by the proper selection of filter capacitance size. Shutdown via cutoff of propellant flow was also demonstrated. A simple electrical circuit model was developed and is shown to have good agreement with the experimental data.

Snyder, John S.↗

Experimental study of high-energy single-pulse nanosecond discharges in pin-to-pin configuration

Single-pulse pin-to-pin nanosecond pulsed discharges in ambient air (gap distances of 3–7 mm) were investigated at high pulse energies (∼20–30 mJ deposited energy per 11 ns full width at half maximum pulse). A Michelson interferometry setup (532 nm continuous-wave laser) was employed to record time-resolved interferograms of the discharge, enabling spatially resolved calculation of the electron number density. An intensified charge-coupled device camera was used to capture the spatiotemporal evolution of the discharge (streamer formation and spark channel development), and Coherent Anti-Stokes Raman Spectroscopy (CARS) was used to measure post-discharge N 2 vibrational temperatures. Discharge current and voltage were monitored with a back-current shunt. The discharge was initiated with simultaneous cathode-directed and anode-directed streamers that bridge the gap within ∼1 ns and form a luminous, filamentary plasma channel immediately after breakdown. Laser interferometry measurements showed peak electron number densities of the order of 10 1 7–10 18 cm −3 , occurring about 15–20 ns after pulse arrival at the discharge gap. Shorter gap discharges yielded higher peak electron densities, consistent with the higher energy density in the smaller gaps. Spatially, the electron density was highest near the electrodes and decreased toward the midgap region, with 5 and 7 mm gaps exhibiting a pronounced drop in the central channel. CARS indicated initial vibrational temperatures of approximately 4000–6000 K in the spark core of ∼50 ns after the discharge onset, decaying on a ∼500 ns timescale as the plasma cooled and recombined.

Coherent anti-Stokes Raman spectroscopy↗

Townsend to glow discharge transition for a nanosecond pulse plasma in helium: space charge formation and resulting electric field dynamics

Stark polarization spectroscopy is used to investigate the temporal evolution of the electric field distribution in the cathode region of a nanosecond pulsed discharge in helium at 120 Torr. The measurements are performed on the He I transition at 492.19 nm, during the early stages of the discharge formation. The experimental results are compared with the predictions of a 1D fluid model. Time-resolved ICCD images show that the discharge develops as a diffuse, cathode-directed ionization wave with a Townsend-like feature before transitioning into a glow-like structure. Near anode instabilities characterized by filament formation were observed near the high voltage electrode. Within 30 ns, a reduction of the sheath thickness to about 250 μm is observed, coinciding with a gradual increase of the discharge current and proportional increase in electric field at the cathode. Additionally, the cathode electric field corresponding to this sheath with a thickness of 250 μm is about 40 kV cm -1 . A subsequent steep increase of the discharge current leads to a further reduction of the sheath width. The electric field evolution as obtained by the fluid model is in excellent agreement with the measurements and shows that an enhanced ionization near the cathode is causing the space charge formation responsible for the increase in electric field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of additively manufactured surface roughness on small diameter plenums with multiple side discharges for high temperature gas turbine blade cooling applications

Combined heat and power (CHP) applications have significant environmental and economic benefits that are consistent with the goals of the U.S. Department of Energy (DOE). One area that is currently being studied includes the potential benefits of CHP turbine operation at higher turbine inlet temperatures. Internal cooling concepts enabled by additive manufacturing (AM) are of primary interest. Here, the effectiveness of internal cooling is hindered by many factors such as velocity distribution of the cooling air to the hot surface considering impingement cooling. To simulate cooling air exiting from a series of orifices for internal cooling in an airfoil, a straight smooth wall tubing with multiple side discharging orifices is used and compared to additively manufactured tubing (Ti6Al4V Grade 23) with orifice size and spacing as well as inner and outer diameters identical to the smooth wall tubing. Similar to flow discharging form perforated pipes, the flow discharged from individual orifices along the tubes in this study is found to be nonuniformly distributed, and the horizontal (axial direction) momentum can be observed from the experimental data. Discharge velocities have been measured with two-dimensional (2D) particle imaging velocimetry (PIV) and single element hot wire anemometry. Numerical analysis has also been conducted to predict the velocity distributions along the orifices in the smooth wall and additive manufacturing (AM) tubing, which are inherited with surface roughness. Numerical and measured results in this study are compared, presented, and discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Relative performance comparison between baseline labyrinth and dual-brush compressor discharge seals in a T-700 engine test

In separate series of YT-700 engine tests, direct comparisons were made between the forward-facing labyrinth and dual brush compressor discharge seals. Compressor speeds to 43 000 rpm, surface speeds to 160 m/s (530 ft/s), pressures to 1 MPa (145 psi), and temperatures to 680 K (765 F) characterized these tests. The wear estimate for 46 hr of engine operations was less than 0.025 mm (0.001 in.) of the Haynes 25 alloy bristles running against a chromium-carbide-coated rub runner. The pressure drops were higher for the dual-brush seal than for the forward-facing labyrinth seal and leakage was lower-with the labyrinth seal leakage being 2-1/2 times greater-implying better seal characteristics, better secondary airflow distribution, and better engine performance (3 percent at high pressure to 5 percent at lower pressure) for the brush seal. (However, as brush seals wear down (after 500 to 1000 hr of engine operation), their leakage rates will increase.) Modification of the secondary flow path requires that changes in cooling air and engine dynamics be accounted for.

Hendricks, Robert C.↗

Double-ended metal halide arc discharge lamp with electrically isolated containment shroud

A double-ended arc discharge lamp includes a sealed, light-transmissive outer jacket, a light-transmissive shroud mounted within the outer jacket and directly supported by the outer jacket, and an arc discharge tube mounted within the shroud. The arc tube is typically a metal halide arc discharge tube. In a preferred embodiment, the shroud includes an outwardly flared portion at each end. The outwardly flared portions space the shroud from the outer jacket and support the shroud within the outer jacket. The outwardly flared portions of the shroud can be affixed to the outer jacket by fusing. The outer jacket can be provided with inwardly extending dimples for locating the shroud with respect to the outer jacket. In another embodiment, the outer jacket includes reduced diameter portions near each end which are attached to the shroud.

Muzeroll, Martin M.↗

Double-ended metal halide arc discharge lamp with electrically isolated containment shroud

A double-ended arc discharge lamp includes a sealed, light-transmissive outer jacket, a light-transmissive shroud mounted within the outer jacket and directly supported by the outer jacket, and an arc discharge tube mounted within the shroud. The arc tube is typically a metal halide arc discharge tube. In a preferred embodiment, the shroud includes an outwardly flared portion at each end. The outwardly flared portions space the shroud from the outer jacket and support the shroud within the outer jacket. The outwardly flared portions of the shroud can be affixed to the outer jacket by fusing. The outer jacket can be provided with inwardly extending dimples for locating the shroud with respect to the outer jacket. In another embodiment, the outer jacket includes reduced diameter portions near each end which are attached to the shroud.

Muzeroll, Martin M.↗

Electronic Switch Arrays for Managing Microbattery Arrays

Integrated circuits have been invented for managing the charging and discharging of such advanced miniature energy-storage devices as planar arrays of microscopic energy-storage elements [typically, microscopic electrochemical cells (microbatteries) or microcapacitors]. The architecture of these circuits enables implementation of the following energy-management options: dynamic configuration of the elements of an array into a series or parallel combination of banks (subarrarys), each array comprising a series of parallel combination of elements; direct addressing of individual banks for charging/or discharging; and, disconnection of defective elements and corresponding reconfiguration of the rest of the array to utilize the remaining functional elements to obtain the desited voltage and current performance. An integrated circuit according to the invention consists partly of a planar array of field-effect transistors that function as switches for routing electric power among the energy-storage elements, the power source, and the load. To connect the energy-storage elements to the power source for charging, a specific subset of switches is closed; to connect the energy-storage elements to the load for discharging, a different specific set of switches is closed. Also included in the integrated circuit is circuitry for monitoring and controlling charging and discharging. The control and monitoring circuitry, the switching transistors, and interconnecting metal lines are laid out on the integrated-circuit chip in a pattern that registers with the array of energy-storage elements. There is a design option to either (1) fabricate the energy-storage elements in the corresponding locations on, and as an integral part of, this integrated circuit; or (2) following a flip-chip approach, fabricate the array of energy-storage elements on a separate integrated-circuit chip and then align and bond the two chips together.

Mojarradi, Mohammad↗

Relative performance comparison between baseline labyrinth and dual-brush compressor discharge seals in a T-700 engine test

In separate series of T-700 engine tests, direct comparisons were made between the forward-facing labyrinth and dual-brush compressor discharge seals. Compressor speeds to 43,000 rpm, surface speeds to 160 m/s (530 ft/s), pressures to 1 MPa (145 psi), and temperatures to 680 K (765 F) characterized these tests. The wear estimate for 40 hr of engine operations was less than 0.025 mm (0.001 in.) of the Haynes 25 alloy bristles running against a chromium-oxide-coated rub runner. The pressure drops were higher for the dual-brush than for the forward-facing labyrinth seal, implying better seal characteristics and engine performance for the brush seal. Modification of the secondary flow path requires that changes in cooling air and engine dynamics be accounted for.

Hendricks, Robert C.↗

Enhancing Streamflow Forecast and Extracting Insights Using Long-Short Term Memory Networks With Data Integration at Continental Scales

Recent observations with varied schedules and types (moving average, snapshot, or regularly spaced) can help to improve streamflow forecasts, but it is challenging to integrate them effectively. Based on a long short-term memory (LSTM) streamflow model, we tested multiple versions of a flexible procedure we call data integration (DI) to leverage recent discharge measurements to improve forecasts. DI accepts lagged inputs either directly or through a convolutional neural network unit. DI ubiquitously elevated streamflow forecast performance to unseen levels, reaching a record continental-scale median Nash-Sutcliffe Efficiency coefficient value of 0.86. Integrating moving-average discharge, discharge from the last few days, or even average discharge from the previous calendar month could all improve daily forecasts. Directly using lagged observations as inputs was comparable in performance to using the convolutional neural network unit. Importantly, we obtained valuable insights regarding hydrologic processes impacting LSTM and DI performance. Before applying DI, the base LSTM model worked well in mountainous or snow-dominated regions, but less well in regions with low discharge volumes (due to either low precipitation or high precipitation-energy synchronicity) and large interannual storage variability. DI was most beneficial in regions with high flow autocorrelation: it greatly reduced baseflow bias in groundwater-dominated western basins and also improved peak prediction for basins with dynamical surface water storage, such as the Prairie Potholes or Great Lakes regions. However, even DI cannot elevate performance in high-aridity basins with 1-day flash peaks. Despite this limitation, there is much promise for a deep-learning-based forecast paradigm due to its performance, automation, efficiency, and flexibility.

54 ENVIRONMENTAL SCIENCES↗

Optimized V1G and V2G Electric Vehicle Fleet Management and Grid Transaction at Marine Corps Air Station Miramar in San Diego, CA

The overall technical goal of the project was to demonstrate an all-electric bi-directional non-tactical fleet at Marine Corps Air Station (MCAS) Miramar that was integrated and controlled with other distributed energy resources (DERs) (i.e., PV, stationary battery, and building loads) to provide resilience to critical electric loads in the event of grid outages, to minimize charging costs, and to provide economic energy resources to electricity markets. In this project, the specific, technical objectives were: 1. Demonstrate that bi-directional electric vehicles can provide critical complementary services to fixed storage batteries in microgrid applications while performing function as non-tactical vehicles. 2. Demonstrate participation of bi-directional (V2G) and unidirectional (V1G) PEVs for demand management and minimization of charging costs. 3. Demonstrate integration of multiple DERs for grid service participation. US Marine Corps Air Station (MCAS) Miramar in San Diego was the site of this electric vehicle-to-microgrid-utility grid test and demonstration project. Existing microgrid assets in this study included (1) a public works building; (2) a 30-kW rooftop photovoltaic (PV) system and (3) a separate 250 kW carport PV system. In this project, six bi-directional V2G vans were located at the MCAS Miramar’s showcase building-scale microgrid to develop and test technical capabilities that V2G can provide in microgrid applications (e.g., cost reduction and resiliency). These resources provided aggregated demand management and simulated participation in current retail DR programs. The vehicles used in this demonstration were selected because they provided functionality that MCAS Miramar needed, 15 passenger transport and facilities work cargo carrying capacity, and bi-directional charging capability that the research project required. All vehicles in this study were manufactured and distributed by VIA Motors, Inc. There were six vehicles total and each was VIA’s VTRUX eREV V2G model, a modified General Motors Chevrolet 2500 2WD van. Three of the vans were configured as passenger vans and the other three were configured as cargo vans. Each van had an on-board bi-direcrtional inverter/charger, Bel Power Solutions model 350INVCHGT150-120-240-8G nominally rated at +/-15 kW. The VIA van’s charging connector follows the J1772 charging protocol. The bi-directional EVSEs demonstrated in this study were manufactured by Coritech, Inc. Each VGI-80-AC charging station enabled enhanced V2G charging capability to a Clipper Creek CS-100 charging module. The enhanced capabilities included ethernet communication following the SEP2.0 protocol with a distributed energy resource function set and an operator screen displaying real-time SOC, voltage, and current. The VGI-80-AC charging stations are classified as level 2 with a maximum current output of 80 A or effectively 19 kW. The VIA van’s onboard charger limited the charging and discharging power to 15 kW in each direction. A control computer was installed in the EWOC and connected to an existing monitor. The V2G control communication network was a completely stand-alone closed system that did not have any connection to any other networks on the base. A cybersecure remote communication connection was created with a cellular modem, firewall hardware, and a virtual private network configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid regulation services for energy storage devices based on grid frequency

Disclosed herein are representative embodiments of methods, apparatus, and systems for charging and discharging an energy storage device connected to an electrical power distribution system. In one exemplary embodiment, a controller monitors electrical characteristics of an electrical power distribution system and provides an output to a bi-directional charger causing the charger to charge or discharge an energy storage device (e.g., a battery in a plug-in hybrid electric vehicle (PHEV)). The controller can help stabilize the electrical power distribution system by increasing the charging rate when there is excess power in the electrical power distribution system (e.g., when the frequency of an AC power grid exceeds an average value), or by discharging power from the energy storage device to stabilize the grid when there is a shortage of power in the electrical power distribution system (e.g., when the frequency of an AC power grid is below an average value).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reversed-direction 2-point modelling applied to divertor conditions in DIII-D *

Abstract A predictive form of the extended 2-point model known as the ‘reverse 2-point model’, Rev2PM, is applied to a range of detachment levels in the open lower divertor of DIII-D, showing that the experimentally measured electron temperature ( T e ) and pressure ( p e ) at the divertor entrance can be calculated within 50% from target measurements, if and only if a posteriori corrections for convective heat flux are included in the model. Unlike the standard 2-point model, the Rev2PM calculates upstream scrape-off layer (SOL) quantities (such as separatrix T e and p e ) from target conditions (such as T e and parallel heat flux), with volumetric power and momentum losses depending solely on target T e . The Rev2PM is tested against a database of DIII-D inter-ELM divertor Thomson scattering measurements, built from a series of 6 MW, 1.3 MA, LSN H-mode discharges with varied main ion density, drift direction, and nitrogen puffing rate. Measured target T e ranged from 0.4–25 eV over this database, and upstream T e ranged from 5–60 eV. Poor agreement is found between upstream measurements and Rev2PM calculations that assume purely conductive parallel heat transport. However, introducing a posteriori corrections to account for convective heat transport brings the Rev2PM calculations within 50% of the measured upstream values across the dataset. These corrections imply that up to 99% of the parallel heat flux is carried by convection in detached conditions in the DIII-D open lower divertor, though further work is required to assess any potential dependencies on device size or divertor closure.

2-point model↗