Search NASA⌕ Search

SEARCH · Search NASA

Results for “directional heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Using MathCad to Evaluate Exact Integral Formulations of Spacecraft Orbital Heats for Primitive Surfaces at Any Orientation

With the advent of high speed computing Monte Carlo ray tracing techniques has become the preferred method for evaluating spacecraft orbital heats. Monte Carlo has its greatest advantage where there are many interacting surfaces. However Monte Carlo programs are specialized programs that suffer from some inaccuracy, long calculation times and high purchase cost. A general orbital heating integral is presented here that is accurate, fast and runs on MathCad, a generally available engineering mathematics program. The integral is easy to read, understand and alter. The integral can be applied to unshaded primitive surfaces at any orientation. The method is limited to direct heating calculations. This integral formulation can be used for quick orbit evaluations and spot checking Monte Carlo results.

Pinckney, John↗

Fundamentals of heat measurement

Various methods and devices for obtaining experimental data on heat flux density over wide ranges of temperature and pressure are examined. Laboratory tests and device fabrication details are supplemented by theoretical analyses of heat-conduction and thermoelectric effects, providing design guidelines and information relevant to further research and development. A theory defining the measure of correspondence between transducer signal and the measured heat flux is established for individual (isolated) heat flux transducers subject to space and time-dependent loading. An analysis of the properties of stacked (series-connected) transducers of various types (sandwich-type, plane, and spiral) is used to derive a similarity theory providing general governing relationships. The transducers examined are used in 36 types of derivative devices involving direct heat loss measurements, heat conduction studies, radiation pyrometry, calorimetry in medicine and industry and nuclear reactor dosimetry.

Gerashchenko, O. A.↗

Energy Where it Matters: Delivering Heat to the Membrane/Water Interface for Enhanced Thermal Desalination

The overall goal of the project is the development of a solar-driven membrane distillation (MD) process that can treat high salinity brines (>100 g/L) at a cost below $1.5/m3. The process relies on thermally and electrically conducting MD membranes that deliver solar heat directly to the membrane surface and prevent membrane fouling through the application of electrical potentials to the membrane surface.

14 SOLAR ENERGY↗

Numerical Investigation of Susceptor-Catalyst Design for Ethylene Generation in Radio Frequency Based Reactors

Ethylene is the most widely produced petrochemical component in the world. Whether reactors are heated directly or indirectly via steam, manufacturers use economies of scale to overcome inherent thermodynamic inefficiencies when burning fossil fuels. While allowing large-scale operations to use alternative sources of energy and raw materials, new methods of supplying energy to chemical reactor systems can reduce the energy waste produced by conventional processes. One viable method for effectively supplying energy to reactor systems is electromagnetic (EM) induction heating. Using the properties of radio frequency (RF) waves, heterogeneous catalysts can be precisely targeted for heating inside reactors. Site-selective heating can greatly lower the energy requirements of the process by supplying heat to reaction sites while reducing needless heat transfer elsewhere. In this study, a microscale model was used to help create guidelines for susceptors and catalysts to improve ethylene production. The oxidative dehydrogenation of ethane is investigated by utilizing several catalysts and potential catalyst/susceptor combinations, with heat provided by an EM susceptor. Having the susceptors and catalyst function separately results in higher gradients in both heat and mass transfer, which drives transport through the catalyst region, while still providing adequate heating for endothermic reactions. However, using a susceptive core with a catalyst covering produces the maximum ethylene concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of Turbulence Parameters, Reynolds Number, and Body Shape on Stagnation-Region Heat Transfer

The purpose of the present work was threefold: (1) to determine if a free-stream turbulence length scale existed that would cause the greatest augmentation in stagnation-region heat transfer over laminar levels; (2) to investigate the effect of velocity gradient on stagnation-region heat transfer augmentation by free-stream turbulence; and (3) to develop a prediction tool for stagnation heat transfer in the presence of free-stream turbulence. Heat transfer was measured in the stagnation region of four models with elliptical leading edges that had ratios of major to minor axes of 1:1, 1.5:1, 2.25:1, and 3:1. Five turbulence-generating grids were fabricated; four were square mesh, biplane grids made from square bars. The fifth grid was an array of fine parallel wires that were perpendicular to the model spanwise direction. Heat transfer data were taken at Reynolds numbers ranging from 37 000 to 228 000. Turbulence intensities were in the range of 1.1 to 15.9% while the ratio of integral length scale to leading-edge diameter ranged from 0.05 to 0.30. Stagnation-point velocity gradient was varied by nearly 50%. Stagnation-region heat transfer augmentation was found to increase with decreasing length scale but no optimum length scale was found. Heat transfer augmentation due to turbulence was found to be unaffected by the velocity gradient near the leading edge. A correlation was developed that fit heat transfer data for the square-bar grids to within +/- 4%.

Vanfossen, G. James↗

Hierarchical thermal-conductive polymer nanocomposites for thermal management

Managing heat in electrical conductors is a major challenge to meet the demands for sustainable energy use and electrical reliability, most notably power electronics and energy-critical electrical machines. Achieving such disparate functionalities, such as high temperature thermal and electrical reliability, require rational design and manufacturing of thermal conductor material and its hierarchical structures. Here we present hierarchical thermal-conductive nanocomposites, consisting of nanostructured ceramic conformal coating and aligned ultrahigh molecular weight polyethylene fiber, to tailor heat dissipation in electric conductors. The hybrid aligned thermal interface exhibits a highly desirable temperature dependent anisotropic high thermal conductivity with 0.98W m –1 K –1 and dielectric strength with 3.4. In addition, electrically insulating thermal interfaces demonstrate high-performing and reliable electrical systems under the dynamic load conditions. The surface temperature of heterogeneous ceramic-polymer encapsulated conductor is 17.8 °C lower than that of polymer-encapsulated conductor at the same electrical load. Consequently, the findings shown here hold great promises for directing heat extraction in electrical machine systems, advancing thermal management for emerging electronic applications.

36 MATERIALS SCIENCE↗

Pushing the Envelope-Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream: Preprint

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

anisotropic envelope↗

Pushing the Envelope—Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

Shrestha, Som↗

Primary helium heater for propellant pressurization systems

The primary helium heater is a unique design that provides direct heating of pressurant gas for large pressure fed propulsion systems. It has been conceptually designed to supply a heated (800-1000 R) pressurization gas to both a liquid oxygen and an RP-1 propellant tank. This pressurization gas is generated within the heater by mixing super critical helium (40-300 R and 3000-1600 psi) with an appropriate amount of combustion products from a 4:1 throttling stoichiometric LO2/LH2 combustor. This simple, low cost and reliable mixer utilizes the large quantity of helium to provide stoichiometric combustor cooling, extend the throttling limits and enhance the combustion stability margin. Preliminary combustion, thermal, and CFD analyses confirm that this low-pressure-drop direct helium heater can provide the constant-temperature pressurant suitable for tank pressurization of both fuel and oxidizer tanks of large pressure fed vehicles.

Reichmuth, D. M.↗

Numerical Investigation of High Delta T Sensible Storage Integrated CO2 Heat Pump: Preprint

To assist building heating electrification, this paper numerically investigates a load flexible heat pump system for commercial buildings. The system consists of a CO2 vapor compression cycle, a sensible thermal storage tank, and an air handling unit. The thermal storage medium is inexpensive, non-toxic and stable anti-freeze solution (30% potassium acetate). The air handing unit has an indoor coil and a ventilation coil. The system can be used to manage building electric load. During peak hours, the heat pump is off and the hot solution water is discharged from the tank to heat up the indoor air and ventilation air. During the hour of charge, the heat pump delivers hot solution water to the tank and to the air. The tank can also stand by while the heat pump provides space heating directly. We selected a medium sized office building located in Minnesota as the representative building and used EnergyPlus to obtain its 24 hour load data. We designed three storage tank volumes assuming 50 degrees C, 65 degrees C and 80 degrees C tank temperatures to independently provide the building load for 4 hours in the morning. The higher the tank temperature, the smaller the required volume, and thus higher energy density. The effective energy density is 78 with an 80 degrees C tank, and 40 kWhth/m3 with 50 degrees C. We simulated the tank integrated heat pump performance subjected to the 24-hour building load profile and ambient data. The baseline is the same system without storage tank. There was a trade-off between the storage energy density and the charging COP. The charge hour COP was 2.77 to charge the tank to 80 degrees C, and 3.01 to 50 degrees C. The proposed system could shift building load from the peak hours (8:00 - 12:00) to off-business hour (23:00 - 7:00+1). It eliminated 100% compressor electricity use during the peak hours, and avoided a peak electric power of 34 kW. The 65 degrees C tank saved 9.5 kWhe (4%) considering all day operation, which was the best balance between energy density and the system operation efficiency among the three options.

CO2 heat pump↗

Design, modeling and simulation of nuclear-powered integrated energy systems with cascaded heating applications

Nuclear-renewable integrated energy systems (IES) consist of a variety of energy generation and conversion technologies and can be used to meet heterogeneous end uses (e.g., electricity, heat, and cooling demands). In addition to supply-demand balance, end-use heat demands usually require heat supply of certain temperature ranges. The effective and efficient utilization of heat produced within an IES is, therefore, a critical challenge. Here, this paper examines design options of an IES that includes heating processes of multiple temperature grades. We investigate a cascaded design configuration, where the remaining residual heat after high-grade heating processes [e.g., hydrogen production through high-temperature steam electrolysis (HTSE)] is recovered to meet the low-grade heating needs [e.g., district heating (DH)]. Additionally, a thermal energy storage system is integrated into the DH system to address the imbalance between heat supply and demand. This paper primarily focuses on the design and modeling of the proposed system and evaluates its operation with a 24-h transient process simulation using a DH demand profile with hourly resolution. The results indicate that the residual heat from the HTSE exhaust is insufficient for the DH demand, and additional topping heat directly from the reactor process steam is needed. Furthermore, the inclusion of thermal energy storage within the DH system provides the necessary balance between thermal generation and demand, thereby ensuring a consistent rated temperature of the DH supply water. This approach helps minimize the control actions needed on the reactor side.

08 HYDROGEN↗

The stable auroral red arc of October 31 - November 1, 1968 and its interaction with the neutral atmosphere

Satellite observations of electron temperature and the topside electron density structure are used to calculate the red arc according to the thermal conduction model. In this model, energy from the magnetosphere flows in the electron gas along geomagnetic field lines into the ionosphere. This energy heats the ambient F-region electrons sufficiently to excite the oxygen atoms to the O I(1D) level by collisional impact giving rise to the 6300 A emission characteristic of the arc. For the 31 October/1 November 1968 red arc, the calculated emission rate, geographical position, and horizontal extent of the red arc are in agreement with the photometric data obtained by airglow observatories. Almost all of the energy conducted into the red arc is ultimately transferred to the neutral gas through elastic and inelastic collisions. This energy drives a large thermal cell and the circulation extends the influence of the arc thousands of kilometers beyond the region of direct heat input. The calculated neutral gas temperature response to electron heating within the arc is small.

Roble, R. G.↗

Direct-Interface, Fusible Heat Sink

Nonventing, regenerable, and self-contained heat sink absorbs heat in melting of ice by direct contact with forced flow of warm water. Elastic bladder contains water and ice. Connectors designed to prevent leaks easily connectable and disconnectable. Female portions embedded in wall of heat sink. After water frozen, male portions inserted and flow of warm water initiated. Water melts ice in and around female connectors, then flow passes between ice and bladder from inlet to outlet. Component of low-power portable refrigerator to operate for short time in picnic or camp setting.

Lomax, Curtis↗

An analysis of alcohol compression ignition strategies on different engine platforms

Strategies that enable ignition of the low cetane alcohol fuels (methanol and ethanol) include intake heating (direct or via hot residual trapping), increased compression ratio (CR), multi-injection strategies, ignition enhancers, and active prechambers. The literature consistently shows alcohol compression ignition (CI) is more efficient than diesel at high loads irrespective of ignition strategy but shows contradictory results at low loads. To understand this, this work combines data from four different engine platforms ranging from a displaced volume of 0.4 to 2.1 L/cyl. using different alcohol CI ignition strategies. Using modeling to support experimental analysis, alcohol-specific efficiency penalties are highlighted to inform alcohol combustion system development. The alcohols’ lower energy density means more fuel must be injected near top dead center to achieve a given load, increasing the relative penalty of sensible/latent heating. Pilot injections help reduce this penalty. Intake heating incurs both a heat transfer penalty and a thermodynamic penalty due to a reduced ratio of specific heats during compression. A strategy that combines elevated CR, large pilot injections, and ignition enhancers can avoid this penalty. Alternatively, a prechamber strategy can achieve this without changing the CR, nor needing ignition enhancers in the fuel. At low loads, diesel burns in a partially premixed mode characterized by high burn rates and low heat losses, reducing alcohol-specific combustion benefits. Alcohol CI on the light-duty platform showed abnormally high heat transfer over diesel compared to other platforms, favoring a more premixed/partially premixed strategy despite a combustion efficiency tradeoff.

33 ADVANCED PROPULSION SYSTEMS↗

Anisotropic Thermally Conductive Composites Enabled by Acoustophoresis and Stereolithography

Opportunities to improve thermal management in electronic devices are currently hindered by processing constraints that limit thermal conductivity in polymer-matrix composites. Active patterning of filler particles is a promising route to improve conductivity while retaining processability by improving particle contact density and directing heat along optimized pathways. Here, we employ acoustic patterning to align and compact filler particles into stripes during stereolithographic 3D printing. This approach produces polymer-based composite materials with highly efficient embedded heat transport pathways which reach 95 vol% particle utilization (relative to the parallel conduction upper limit). These composites exhibit anisotropic thermal conductivity up to 300% higher than unpatterned composites, with in-plane anisotropy ratios of up to 350%. Combining this high conductivity with 3D printing enables materials with engineered heat networks that optimize transport from hot spots to heatsinks while maintaining low viscosity for fast particle patterning and for infiltration around electronic components. Finally, numerical simulations of acoustic assembly of particles with varied geometry, when compared to experimentally characterized particle packing, illuminate pathways for further improving conductivity by optimizing particle geometry for alignment and stacking of particles with maximum contact surface area.

36 MATERIALS SCIENCE↗

A direct-interface fusible heat sink for astronaut cooling

Astronaut cooling during extravehicular activity is a critical design issue in developing a portable life support system that meets the requirements of a space station mission. Some the requirements are that the cooling device can be easily regenerable and nonventing during operation. In response to this, a direct-interface, fusible heat sink prototpye with freezable quick-disconnects was developed. A proof-of-concept prototype was constructed and tested that consists of an elastic container filled with normal tap water and having two quick-disconnects embedded in a wall. These quick-disconnects are designed so that they may be frozen with the ice and yet still be joined to the cooling system, allowing an immediate flow path. The inherent difficulties in a direct-interface heat sink have been overcome, i.e., (1) establishing an initial flow path; (2) avoiding low-flow freeze-up; and (3) achieving adequate heat-transfer rates at the end of the melting process. The requirements, design, fabrication, and testing are discussed.

Lomax, Curtis↗

A direct-interface, fusible heat sink for astronaut cooling

Astronaut cooling during extravehicular activity is a critical design issue in developing a portable life support system that meets the requirements of a space station mission. Some of the requirements are that the cooling device can be easily regenerable and nonventing during operation. In response to this, a direct-interface, fusible heat sink prototype with freezable quick-disconnects was developed. A proof-of-concept prototype was constructed and tested that consists of an elastic container filled with normal tap water and having two quick-disconnects embedded in a wall. These quick-disconnects are designed so that they may be frozen with the ice and yet still be joined to the cooling system, allowing an immediate flow path. The inherent difficulties in a direct-interface heat sink have been overcome, i.e., (1) establishing an initial flow path; (2) avoiding low-flow freeze-up; and (3) achieving adequate heat-transfer rates at the end of the melting process. The requirements, design, fabrication, and testing are discussed.

Lomax, Curtis↗

Transparent Refractory Aerogels for Efficient Spectral Control in High–Temperature Solar Power Generation

Although spectrally selective materials play a key role in existing and emerging solar thermal technologies, temperature-related degradation currently limits their use to below 700 °C in vacuum and even lower temperatures in air. Here a solar-transparent refractory aerogel that offers stable performance up to 800 °C in air is demonstrated, which is significantly greater than its silica counterpart. This improved stability is attributed to the formation of a refractory aluminum silicate phase, which is synthesized using a conformal single cycle of atomic layer deposition within the high-aspect-ratio pores of silica aerogels. Furthermore, based on direct heat loss measurements, the transparent refractory aerogel achieves a receiver efficiency of 75% at 100 suns and an absorber temperature of 700 °C, which is a 5% improvement over the state of the art. Transparent refractory aerogels may find widespread applicability in solar thermal technologies by enabling the use of lower-cost optical focusing systems and eliminating the need for highly evacuated receivers. In particular, a shift to higher operating temperatures while maintaining a high receiver efficiency can enable the use of advanced supercritical CO 2 power cycles and ultimately translate to an ≈10% (absolute) improvement in solar-to-electrical conversion efficiency relative to existing linear concentrating systems.

14 SOLAR ENERGY↗