Search NASA⌕ Search

SEARCH · Search NASA

Results for “discharging method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Embedded ESD Protection Proof of Concept

The purpose of this project is to characterize and correlate Electrostatic Discharge (ESD) sensitivity levels of an Integrated Circuit (IC) package using Transmission Line Pulse (TLP) and Human Body Model (HBM) methods. This characterization will be used as a baseline ESD sensitivity level to demonstrate improvement to the ESD sensitivity of the IC package through the use of EPI-FLO(Trade Mark) Polymer Voltage Suppression (PVS) protection devices developed and manufactured by Electronic Polymers, Inc. (EPI).

Human Body Model (HBM) methods↗

Runaway electron beams in the gas discharge for UV nitrogen laser excitation

The review of the methods for obtaining the runaway electron beams in the gas discharge is performed. The new method is offered, using which the beam is first formed in a narrow gap ({approx}1 mm) between the cathode and the grid and then it is accelerated by the field of the plasma column of the anomalous self-sustained discharge in the main gap (10-20 mm long). The electron beams with an energy of about 10 keV and current density of 10{sup 3} A/cm{sup 2} at a molecular nitrogen pressure of up to 100 Torr have been obtained experimentally. The results of research of the UV nitrogen laser with an excitation via runaway electron beam and radiation of energy of {approx}1 mJ are given. The UV nitrogen laser generation with the energy of {approx}1 mJ has been obtained by the runaway electron beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of the electron density and degree of plasma ionization in a plasma target based on a linear electric discharge in hydrogen

Laser interferometry methods were used to measure the density of free electrons and degree of plasma ionization in a hydrogen target intended for experiments on determining energy losses of heavy ion beams in an ionized matter. It is shown that the linear electron density can be varied in the range from 3.3 Multiplication-Sign 10{sup 17} to 1.3 Multiplication-Sign 10{sup 18} cm{sup -2} by varying the initial plasma parameters (the hydrogen pressure in the target and the discharge current). The error in measuring the linear electron density in the entire range of the varied plasma parameters was less than 1%. The maximum degree of plasma ionization achieved at the initial gas pressure of 1 mbar was 0.62 {+-} 0.05.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Higher Harmonics in Multipactor Induced Plasma Ionization Breakdown near a Dielectric Surface

In this Letter, the novel physics of higher harmonic (HH) generation of the normal electric field near a dielectric surface is reported in multipactor induced plasma ionization breakdown, as determined by kinetic particle-in-cell simulations. The observed HH frequency is around ten times the fundamental rf driving frequency, but lower than the electron plasma frequency. A theory is constructed which indicates that stream plasma interaction-induced instability is the mechanism of HH generation in the collisional regime. The HH frequency and its corresponding growth rate of the HH oscillation amplitude from the theory are in good agreement with kinetic particle-in-cell simulations.

60 APPLIED LIFE SCIENCES↗

An Experimental Study of the Ionization of Low-Density Gas Flows by Induced Discharges

Induced discharges are advantageous for ionizing low-density flows in that they introduce no electrode contamination into the flow and they provide a relatively high degree of ionization with good coupling of power into the gas. In this investigation a 40-megacycle oscillator was used to produce and maintain induced discharges in argon and mercury-vapor flows. Methods for preventing blowout of the discharge were determined, and power measurements were made with an in-line wattmeter. Some results with damped oscillations pulsed at 1,000 pulses per second are also presented.

Barger, R. L.↗

A plasma needle for generating homogeneous discharge in atmospheric pressure air

Homogeneous discharge in air is often considered to be the ultimate low-temperature atmospheric pressure plasmas for industrial applications. In this paper, we present a method whereby stable homogeneous discharge in open air can be generated by a simple plasma needle. The discharge mechanism is discussed based on the spatially resolved light emission waveforms from the plasma. Optical emission spectroscopy is used to determine electron energy and rotational temperature, and results indicate that both electron energy and rotational temperature increase with increasing the applied voltage. The results are analyzed qualitatively based on the discharge mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An analysis of the frequency characteristics of corona discharge at low pressure

Corona discharge is becoming more of a concern now that the space program is looking at higher power and voltage requirements for future missions. Improved detection methods for studying corona discharge will increase the knowledge base of how this phenomenon occurs, what effects it has on power systems, and how it is affected by outside influences. A better understanding of corona discharge will enable designers to improve on the space applications of insulation and dielectrics, and develop proper detection techniques. A test system was designed and constructed to measure the frequency spectrum of corona discharge current in low pressure. Various test samples in different arrangements were energized by ac voltage until corona discharge occurred. This same test was repeated at different pressures. The results indicate that the frequency spectrum of the discharge current changes with a change in pressure. At low pressures, the discharge frequency spectrum is concentrated in a narrow band with a peak at 17 kHz. As the pressure is increased, the spectral width increases to include components across a much broader band. Other tests were performed to correlate the frequency spectrum data to the shape of the discharge pulse and the physical appearance of the glow discharge.

T Gregory Lewis↗

Radioisotope Analysis of Wastewater from Livermore Site Retention Tanks by Gel Laboratory Gross Alpha, Gross Beta and Tritium Sampling Method

Lawrence Livermore National Laboratory discharged approximately 4.4% of the City of Livermore’s total wastewater in 2022 (LLNL’s Annual Site Environmental Report, Chapter 5, 2022). This volume includes wastewater from Sandia National Laboratories (SNL) and some process wastewater from Site 300. Due to the high volume and constituents of the discharge, LLNL works alongside the City of Livermore under permit #1250, requiring wastewater generated to be monitored and sampled in accordance with permit limits. Process wastewater, from buildings with the highest risk to sewer, is collected by wastewater retention tanks throughout the Livermore Site and sampled prior to discharge. Domestic wastewater directly discharges to sanitary sewer. To maintain permit requirements and ensure proper wastewater discharge practices, an internal wastewater audit was conducted during the summer of 2023. Current wastewater practices, regulatory knowledge and risk management across various Livermore Site buildings were evaluated. Workspaces connected to a wastewater retention tank and sanitary sewer drains were major focus areas. Data collected from walk-throughs prompted further evaluation as many practices were reported to be done based on historical usage. A table of concerns was created to showcase reasons for auditing and proceeding action. An analysis of current and historical retention tank usage throughout LLNL Livermore Site buildings with radioisotope results over a 5-year period from 2019 to 2024, was done to assess building trends and any significant changes throughout the 5-year period. Analytes evaluated were Gross Alpha, Gross Beta and Tritium (GABT) of eleven buildings at the Livermore Site, posing the highest risk to sanitary sewer for radioisotopes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preparation and electrochemical characterization of lithium cobalt oxide nanoparticles by modified sol-gel method

Uniformly distributed nanoparticles of LiCoO{sub 2} have been synthesized through the simple sol-gel method in presence of neutral surfactant (Tween-80). The powders were characterized by X-ray diffractometry, transmission electron microscopy and electrochemical method including charge-discharge cycling performance. The powder calcined at a temperature of 900 deg. C for 5 h shows pure phase layered LiCoO{sub 2}. The results show that the particle size is reduced in presence of surfactant as compared to normal sol-gel method. Also, the sample prepared in presence of surfactant and calcined at 900 deg. C for 5 h shows the highest initial discharge capacity (106 mAh g{sup -1}) with good cycling stability as compared to the sample prepared without surfactant which shows the specific discharge capacity of 50 mAh g{sup -1}.

36 MATERIALS SCIENCE↗

Simulation studies of vestibular macular afferent-discharge patterns using a new, quasi-3-D finite volume method

A quasi-three-dimensional finite-volume numerical simulator was developed to study passive voltage spread in vestibular macular afferents. The method, borrowed from computational fluid dynamics, discretizes events transpiring in small volumes over time. The afferent simulated had three calyces with processes. The number of processes and synapses, and direction and timing of synapse activation, were varied. Simultaneous synapse activation resulted in shortest latency, while directional activation (proximal to distal and distal to proximal) yielded most regular discharges. Color-coded visualizations showed that the simulator discretized events and demonstrated that discharge produced a distal spread of voltage from the spike initiator into the ending. The simulations indicate that directional input, morphology, and timing of synapse activation can affect discharge properties, as must also distal spread of voltage from the spike initiator. The finite volume method has generality and can be applied to more complex neurons to explore discrete synaptic effects in four dimensions.

NASA Center ARC↗

Particle-in-cell simulation of hydrogen discharge driven by combined radio frequency and pulse sources

A particle-in-cell plus Monte Carlo collision model is employed to investigate the low pressure hydrogen capacitive discharge driven by combined radio frequency (rf) and pulse sources. This work focuses on the evolutions of electron energy and density in the discharge to illustrate the role that a short pulse source plays. The simulation results show that an extra short pulse source can modulate the electron energy effectively: in the early and late pulse-on times, the electron energy is much higher than that in the single rf source discharge; during the pulse-off time, the electron energy can drop gradually to a low value. It is also found that a few peaks of attenuated electron energy appear periodically just after the pulse voltage drops to zero. The similar phenomena can also be found in the production rate of highly vibrationally excited hydrogen molecules. Physical mechanisms responsible for these phenomena are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct current dielectric barrier assistant discharge to get homogeneous plasma in capacitive coupled discharge

In this paper, we propose a method to get more homogeneous plasma in the geometrically asymmetric capacitive coupled plasma (CCP) discharge. The dielectric barrier discharge (DBD) is used for the auxiliary discharge system to improve the homogeneity of the geometrically asymmetric CCP discharge. The single Langmuir probe measurement shows that the DBD can increase the electron density in the low density volume, where the DBD electrodes are mounted, when the pressure is higher than 5 Pa. By this manner, we are able to improve the homogeneity of the plasma production and increase the overall density in the target volume. At last, the finite element simulation results show that the DC bias, applied to the DBD electrodes, can increase the homogeneity of the electron density in the CCP discharge. The simulation results show a good agreement with the experiment results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature dependence of the NO3 absorption spectrum

The absorption spectrum of the gas-phase NO3 radical has been studied between 220 and 700 nm by using both flash photolysis and discharge flow reactors for the production of NO3. In the flash photolysis method, cross sections at the peak of the (0,0) band at 661.9 nm were measured relative to the cross section of ClONO2 at several different wavelengths. From the best current measurements of the ClONO2 spectrum, the NO3 cross section at 661.9 nm was determined to be (2.28 + or 0.34) x 10 to the -17th sq cm/molecule at 298 K. Measurements at 230 K indicated that the cross section increases by a factor of 1.18 at the peak of the (0,0) band. The discharge flow method was used both to obtain absolute cross sections at 661.9 nm and to obtain relative absorption spectra between 300 and 700 nm at 298 and 230 K. A value of (1.83 + or - 0.27) x 10 to the -17th sq cm/molecule was obtained for sigma NO3 at 661.9 nm at 298 K. Upper limits to the NO3 cross sections were also measured between 220 and 260 nm with the discharge flow method.

Sander, Stanley P.↗

Methods and Apparatus for Pulsed-DC Dielectric Barrier Discharge Plasma Actuator and Circuit

A plasma generating device intended to induce a flow in a fluid via plasma generation includes a dielectric separating two electrodes and a power supply. The first electrode is exposed to a fluid flow while the second electrode is positioned under the dielectric. The power supply is electrically coupled to a switch and the first and second electrodes. When the power supply is energized by repeated action of the switch, it causes a pulsed DC current between the electrodes which causes the fluid to ionize generating a plasma. The generation of the plasma induces a force with a velocity component in the fluid.

Corke, Thomas C.↗

Experimental investigations of silicon tetrafluoride decomposition in ECR discharge plasma

The results of first experiments on the investigation of plasma of electron cyclotron resonance (ECR) discharge, sustained by CW radiation of technological gyrotron with frequency 24 GHz are considered. The parameters of nitrogen plasma of ECR discharge in magnetic field up to 1 T were investigated by Langmuir probe in the pressure range 10{sup -4}-10{sup -2} mbar under different values of microwave power. Depending on gas pressure and power of microwave radiation, the typical temperature and density of electrons could attain values of 1-5 eV and 10{sup 11}-10{sup 12} cm{sup -3}, respectively. The prospects for using of ECR discharge for plasma chemical decomposition of silicon tetrafluoride (SiF{sub 4}) have been experimentally demonstrated. Plasma was created from SiF{sub 4} and hydrogen (H{sub 2}) gas mixture and heated by microwave radiation in ECR conditions. Using the method of mass-spectrometry analysis of the gas at the outlet from the reactor and the weighting method, the content of the resultants of SiF{sub 4} decomposition as a function of process parameters was investigated. It was shown that SiF{sub 4} decomposition degree strongly depends on the microwave power, gas pressure in the reactor, gas flow rates, and can attain the value of 50%. The possible applications of PECVD method based on ECR discharge for production of isotopically pure elements with high deposition rate are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiments and global model of inductively coupled rf Ar/N{sub 2} discharges

Experiments with a Langmuir probe and optical emission spectroscopy are carried out in inductively coupled rf (13.56 MHz) Ar/N{sub 2} discharges at three total pressures of 30, 60, and 110 mTorr, varying the Ar fractions from 50% to 95%. The electron energy probability functions (EEPFs) measured at all Ar fractions can be approximated using different exponentials in the bulk and high-energy regions, resulting in two temperature approximation of the measured EEPFs. The electron density slightly increases with increasing the Ar fraction at the Ar fractions below 70%, beyond which it relatively abruptly increases. On the other hand, the electron temperatures gradually decrease with the increase in the Ar fraction. The vibrational temperature does not strongly depend on the Ar fraction, whereas the rotational temperature gradually increases with the increase in the Ar fraction. The density of nitrogen atoms remains constant at the Ar fractions below 80%, beyond which it monotonically decreases with increasing the Ar fraction. A global model for electropositive plasma is used in order to investigate the plasma chemistry in Ar/N{sub 2} discharges assuming the Maxwellian electron energy distribution. The model results are compared with the experimental results, obtaining reasonably good agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stability evaluation and mitigation strategies in advanced tokamaks using 3D MHD spectroscopy

Multi-modal, active 3D MHD spectroscopy is applied in high-performance advanced tokamak scenarios to study their stability time evolution, revealing an intriguing dependence on both and . A tailored applied 3D field provides a 3D plasma response to extract the growth rate of the least stable mode. The estimated growth rate finds a decrease in stability when the minimum in the safety factor (q) passes through 2.0 and reveals inherent risks of crossing an additional rational surface at integer q min , even above the usual q = 1 sawtooth condition. Based on this result, the potential scenario in which q min ~ 2 can be safely crossed during a more stable lower β N phase was investigated, and the improved stability of this scenario is confirmed by the estimated growth rate. This shows that 3D MHD spectroscopy can offer insights into strategies for improving stability by identifying the vulnerable aspects of such scenarios. In addition, the method highlights its potential for instability avoidance by enabling early detection of multiple modes, even before magnetic coils can measure them. The measured growth rate by the 3D MHD spectroscopy shows its reliability by exhibiting a correlation with the programmed rises in plasma beta across various high β N and high q min discharges. In addition, this method is successfully applied during rapidly evolving I p ramp-up phases, a key part of the scenario development. By achieving reasonable growth rate measurements at high-performance scenario developments, this technique contributes to the development of advanced diagnostic tools for tokamak scenario stability, which will help identify an effective pathway to stable, high-performance scenarios.

Yang, S. M. [Princeton Plasma Physics Laboratory (↗