Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed load sharing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Fundamental Power Coupler Technical Development - Final CRADA Report

The SLAC ‘Linac Coherent Light Source -II’ project (LCLS II) is a hard X-ray Free Electron Laser now under construction in support of photon-based material science. LCLS II uses a superconducting linac design based on the twenty year-long TESLA- Technology development effort. The TESLA proposal, the European XFEL (EU-XFEL) project, and the ILC design employ a pulsed superconducting linac with roughly 0.5% duty factor. This aspect was changed for LCLS II so that the FEL could be operated continuous-wave (CW) namely with a 100% duty factor. Several critical changes to the linac design were required including RF power distribution, cryogenic heat-load management and cavity preparation. This note lists the changes required to the fundamental power coupler (FPC). All of these changes were made by the SLAC physics and engineering teams and reviewed by the cryomodule design lead (Fermilab) and international partners. Testing was done by the LCLS II cryomodule teams (Jefferson Lab and Fermilab). The SLAC LCLS II project team managed the design and procurement process. The LCLS II fundamental power coupler design is based upon the DESY TESLA Test Facility (TTF-3) design. DESY shared their drawings with LCLS II and SLAC copied and modified them to meet the LCLS II CW operation power and heat-load requirements. LCLS II had an external reviewer evaluate and compare SLAC drawings to EU-XFEL drawings. SLAC used the same industrial partners that EU-XFEL used.

47 OTHER INSTRUMENTATION↗

Generating realistic building electrical load profiles through the Generative Adversarial Network (GAN)

Building electrical load profiles can improve understanding of building energy efficiency, demand flexibility, and building-grid interactions. Current approaches to generating load profiles are time-consuming and not capable of reflecting the dynamic and stochastic behaviors of real buildings; some approaches also trigger data privacy concerns. In this study, we proposed a novel approach for generating realistic electrical load profiles of buildings through the Generative Adversarial Network (GAN), a machine learning technique that is capable of revealing an unknown probability distribution purely from data. The proposed approach has three main steps: (1) normalizing the daily 24-hour load profiles, (2) clustering the daily load profiles with the k-means algorithm, and (3) using GAN to generate daily load profiles for each cluster. The approach was tested with an open-source database – the Building Data Genome Project. We validated the proposed method by comparing the mean, standard deviation, and distribution of key parameters of the generated load profiles with those of the real ones. The KL divergence of the generated and real load profiles are within 0.3 for majority of parameters and clusters. Additionally, results showed the load profiles generated by GAN can capture not only the general trend but also the random variations of the actual electrical loads in buildings. We report the proposed GAN approach can be used to generate building electrical load profiles, verify other load profile generation models, detect changes to load profiles, and more importantly, anonymize smart meter data for sharing, to support research and applications of grid-interactive efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scaling Irregular Applications through Data Aggregation and Software Multithreading

Bioinformatics, data analytics, semantic databases, knowledge discovery are emerging high performance application areas that exploit dynamic, linked data structures such as graphs, unbalanced trees or unstructured grids. These data structures usually are very large, requiring significantly more memory than available on single shared memory systems. Additionally, these data structures are difficult to partition on distributed memory systems. They also present poor spatial and temporal locality, thus generating unpredictable memory and network accesses. The Partitioned Global Address Space (PGAS) programming model seems suitable for these applications, because it allows using a shared memory abstraction across distributed-memory clusters. However, current PGAS languages and libraries are built to target regular remote data accesses and block transfers. Furthermore, they usually rely on the Single Program Multiple Data (SPMD) parallel control model, which is not well suited to the fine grained, dynamic and unbalanced parallelism of irregular applications. In this paper we present {\bf GMT} (Global Memory and Threading library), a custom runtime library that enables efficient execution of irregular applications on commodity clusters. GMT integrates a PGAS data substrate with simple fork/join parallelism and provides automatic load balancing on a per node basis. It implements multi-level aggregation and lightweight multithreading to maximize memory and network bandwidth with fine-grained data accesses and tolerate long data access latencies. A key innovation in the GMT runtime is its thread specialization (workers, helpers and communication threads) that realize the overall functionality. We compare our approach with other PGAS models, such as UPC running using GASNet, and hand-optimized MPI code on a set of typical large-scale irregular applications, demonstrating speedups of an order of magnitude.

Aggregation↗

Numerical analysis of modified Central Solenoid insert design

The United States ITER Project Office (USIPO) is responsible for fabrication of the Central Solenoid (CS) for ITER project. The ITER machine is currently under construction by seven parties in Cadarache, France. The CS Insert (CSI) project should provide a verification of the conductor performance in relevant conditions of temperature, field, currents and mechanical strain. The US IPO designed the CSI that will be tested at the Central Solenoid Model Coil (CSMC) Test Facility at JAEA, Naka. To validate the modified design we performed three-dimensional numerical simulations using coupled solver for simultaneous structural, thermal and electromagnetic analysis. Thermal and electromagnetic simulations supported structural calculations providing necessary loads and strains. According to current analysis design of the modified coil satisfies ITER magnet structural design criteria for the following conditions: (1) room temperature, no current, (2) temperature 4K, no current, (3) temperature 4K, current 60 kA direct charge, and (4) temperature 4K, current 60 kA reverse charge. Fatigue life assessment analysis is performed for the alternating conditions of: temperature 4K, no current, and temperature 4K, current 45 kA direct charge. Results of fatigue analysis show that parts of the coil assembly can be qualified for up to 1 million cycles. Distributions of the Current Sharing Temperature (TCS) in the superconductor were obtained from numerical results using parameterization of the critical surface in the form similar to that proposed for ITER. Lastly, special ADPL scripts were developed for ANSYS allowing one-dimensional representation of TCS along the cable, as well as three-dimensional fields of TCS in superconductor material. Published by Elsevier B.V.

42 ENGINEERING↗

Design and Operation of Energy Systems with Large Amounts of Variable Generation: IEA Wind TCP Task 25 (Final Summary Report)

This report summarizes findings on wind integration from the 17 countries or sponsors participating in the International Energy Agency Wind Technology Collaboration Program (IEA Wind TCP) Task 25 from 2006-2020. Both real experience and studies are reported. Many wind integration studies incorporate solar energy, and most of the results discussed here are valid for other variable renewables in addition to wind. The national case studies address several impacts of wind power on electric power systems. In this report, they are grouped under long-term planning issues and short-term operational impacts. Long-term planning issues include grid planning and capacity adequacy. Short-term operational impacts include reliability, stability, reserves, and maximizing the value of wind in operational timescales (balancing related issues). The first section presents the variability and uncertainty of power system-wide wind power, and the last section presents recent studies toward 100% shares of renewables. The appendix provides a summary of ongoing research in the national projects contributing to Task 25 for 2021-2024. The design and operation of power and energy systems is an evolving field. As ambitious targets toward net-zero carbon energy systems are announced globally, many scenarios are being made regarding how to reach these future decarbonized energy systems, most of them involving large amounts of variable renewables, mainly wind and solar energy. The secure operation of power systems is increasingly challenging, and the impacts of variable renewables, new electrification loads together with increased distribution system resources will lead to somewhat different challenges for different systems. Tools and methods to study future power and energy systems also need to evolve, and both short-term operational aspects (such as power system stability) and long-term aspects (such as resource adequacy) will probably see new paradigms of operation and design. The experience of operating and planning systems with large amounts of variable generation is accumulating, and research to tackle the challenges of inverter-based, nonsynchronous generation is on the way. Energy transition and digitalization also bring new flexibility opportunities, both short and long term.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The SNS/HFIR Web Portal System for SANS

In a busy world, continuing with the status-quo, to do things the way we are already familiar, often seems to be the most efficient way to conduct our work. We look for the value-add to decide if investing in a new method is worth the effort. How shall we evaluate if we have reached this tipping point for change? For contemporary researchers, understanding the properties of the data is a good starting point. The new generation of neutron scattering instruments being built are higher resolution and produce one or more orders of magnitude larger data than the previous generation of instruments. For instance, we have grown out of being able to perform some important tasks with our laptops – the data are too big and the computations would simply take too long. These large datasets can be problematic as facility users now begin to grapple with many of the same issues faced by more established computing communities. These issues include data access, management, and movement, data format standards, distributed computing, and collaboration among others. The Neutron Science Portal has been architected, designed, and implemented to provide users with an easy-to-use interface for managing and processing data, while also keeping an eye on meeting modern cybersecurity requirements imposed on institutions. The cost of entry for users has been lowered by utilizing a web interface providing access to backend portal resources. Users can browse or search for data which they are allowed to see, data reduction applications can be run without having to load the software, sample activation calculations can be performed for SNS and HFIR beamlines, McStas simulations can be run on TeraGrid and ORNL computers, and advanced analysis applications such as those being produced by the DANSE project can be run. Behind the scenes is a “live cataloging” system which automatically catalogs and archives experiment data via the data management system, and provides proposal team members access to their experiment data. The complexity of data movement and utilizing distributed computing resources has been taken care on behalf of users. Collaboration is facilitated by providing users a read/writeable common area, shared across all experiment team members. To date, these shared areas are the fastest growing data spaces. The portal currently has over 370 registered users, almost 7TB of experiment and user data, approximately 1,000,000 files cataloged, and had almost 10,000 unique visits last year. Future directions for enhancing portal robustness include examining how to mirror data and portal services, better facilitation of collaborations via virtual organizations, enhancing disconnected service via “thick client” applications, and better inter-facility connectivity to support cross-cutting research. The portal has established itself in the SNS/HFIR user community, and the development team strives to continue to improve the quality of features and services provided in order to better serve the community.

data↗

The SNS/HFIR Web Portal System – How Can it Help Me?

Abstract. In a busy world, continuing with the status-quo, to do things the way we are already familiar, often seems to be the most efficient way to conduct our work. We look for the value-add to decide if investing in a new method is worth the effort. How shall we evaluate if we have reached this tipping point for change? For contemporary researchers, understanding the properties of the data is a good starting point. The new generation of neutron scattering instruments being built are higher resolution and produce one or more orders of magnitude larger data than the previous generation of instruments. For instance, we have grown out of being able to perform some important tasks with our laptops – the data are too big and the computations would simply take too long. These large datasets can be problematic as facility users now begin to grapple with many of the same issues faced by more established computing communities. These issues include data access, management, and movement, data format standards, distributed computing, and collaboration among others. The Neutron Science Portal has been architected, designed, and implemented to provide users with an easy-to-use interface for managing and processing data, while also keeping an eye on meeting modern cybersecurity requirements imposed on institutions. The cost of entry for users has been lowered by utilizing a web interface providing access to backend portal resources. Users can browse or search for data which they are allowed to see, data reduction applications can be run without having to load the software, sample activation calculations can be performed for SNS and HFIR beamlines, McStas simulations can be run on TeraGrid and ORNL computers, and advanced analysis applications such as those being produced by the DANSE project can be run. Behind the scenes is a “live cataloging” system which automatically catalogs and archives experiment data via the data management system, and provides proposal team members access to their experiment data. The complexity of data movement and utilizing distributed computing resources has been taken care on behalf of users. Collaboration is facilitated by providing users a read/writeable common area, shared across all experiment team members. To date, these shared areas are the fastest growing data spaces. The portal currently has over 370 registered users, almost 5TB of experiment and user data, approximately 660K files cataloged, and had almost 10,000 unique visits last year. Future directions for enhancing portal robustness include examining how to mirror data and portal services, better facilitation of collaborations via virtual organizations, enhancing disconnected service via “thick client” applications, and better inter-facility connectivity to support cross-cutting research. The portal has established itself in the SNS/HFIR user community, and the development team strives to continue to improve the quality of features and services provided in order to better serve the community.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data Centers and Digital Assurance Workshop 2 – Prioritizing Digital Assurance Challenges, Session 2

The second session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 10, 2025, focused on prioritizing digital assurance challenges at the intersection of data centers and the electric grid. Building on the foundational concepts introduced in Workshop 1, this session deepened the application of the Threat–Vulnerability–Consequence (TVC) framework and emphasized the urgency of addressing cybersecurity, supply chain integrity, and operational reliability. Participants explored the growing convergence of digital and physical systems, the expanding attack surface due to global supply chain dependencies, and the implications of AI-driven load behavior. Real-world incidents—including the Volt Typhoon campaign and vulnerabilities in Solarman and Deye platforms—were analyzed to illustrate the risks of unpatched systems, insecure APIs, and inadequate vendor oversight. Key themes included architecture and interface weaknesses, governance gaps, and human and procedural shortcomings. The workshop also examined the evolving regulatory landscape, highlighting new federal mandates around Foreign Entity of Concern (FEOC) compliance and large-load reliability standards. Through interactive exercises, stakeholders ranked and mapped digital assurance risks from their respective perspectives—utilities, operators, and vendors—laying the groundwork for mitigation strategies and shared accountability models to be developed in Workshop 3. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Energy Security and Restoration Exercise Program/Best Practices and Information Sharing

The first year of this cooperative agreement focused on the following elements: curriculum development and presentation, curriculum maintenance, enhancements, and effectiveness, and smart card initiative. During the second year of this grant, with redirection from DOE, the IUOE modified its mission statement under the cooperative agreement. It states: 'The mission of the IUOE is to provide expertise to provide best practices, information sharing, and develop scenarios and conduct exercises ranging in size and complexity from table top to national level to prepare all stakeholders to protect and restore energy infrastructure should an event, terrorist or natural, occur'. The Program developed a number of products under this Cooperative Agreement. These products include: FOSTER (Facility Operations Safety Training Event Response) Curriculum and Training Models, Alternative Energy Supply - Generators Training Module, Liquefied Natural Gas Training Module, Education Program - Distributed Generations, Compendium of Resources and References, Energy Security and Restoration Training Manual, Manual of Situations and Scenarios Developed for Emergency Exercises, Manual of Best Practices/Lessons Learned for Energy Load Management, Training Plan, Strategic Information and Exercise Plan, National Certification Plan Report, and a Smart Card Project Report.

03 NATURAL GAS↗

Challenges and Opportunities of Gas Engine Driven Heat Pumps: Two Case Studies

Gas engine driven heat pumps (GHP) currently hold a small market share. This share is considerably smaller than what the full potential of GHP technology can realize. Of the main benefits of the GHP technology is their better primary energy utilization mainly due to the ability to recover the engine heat. However, development and market penetration of GHP technology have been challenged by various market and technical barriers. The main barriers are the high initial cost, low awareness of the technology, and poor perception. On the other hand, several opportunities arise that the GHP technology can take advantage of to increase its market share. The most direct opportunity is the abundance of cheap natural gas. This translates directly into monetary savings and higher ROI. GHPs offer the advantage of reducing the peak demand by 80% compared to electric counterpart. From the point of view of utilities, this eliminates the need for lower-efficiency peaking power plants and over-expansion only to cover maximum peak times. From the point of view of renewable customers, GHPs eliminate the need to buy power from the grid at a high price. This is especially important in hot climates with high cooling loads. When built and operated as distributed generation, GHPs can improve the reliability of power delivery to consumers. The paper discusses the challenges and opportunities as seen during the development and commercialization of two different GHP products; a 10-ton packaged unit and 5-ton split unit.

Abu-Heiba, Ahmad↗

Computational and Experimental Design of Fe-Based Superalloys for Elevated-Temperature Applications

Analogous to nickel-based superalloys, Fe-based superalloys, which are strengthened by coherent B2- type precipitates are proposed for elevated-temperature applications. During the period of this project, a series of ferritic superalloys have been designed and fabricated by methods of vacuum-arc melting and vacuum-induction melting. Nano-scale precipitates were characterized by atom-probe tomography, ultrasmall- angle X-ray scattering, and transmission-electron microscopy. A duplex distribution of precipitates was found. It seems that ferritic superalloys are susceptible to brittle fracture. Systematic endeavors have been devoted to understanding and resolving the problem. Factors, such as hot rolling, precipitate volume fractions, alloy compositions, precipitate sizes and inter-particle spacings, and hyperfine cooling precipitates, have been investigated. In order to understand the underlying relationship between the microstructure and creep behavior of ferric alloys at elevated temperatures, in-situ neutron studies have been carried out. Based on the current result, it seems that the major role of β' with a 16%-volume fraction in strengthening ferritic alloys is not load sharing but interactions with dislocations. The oxidation behavior of one ferritic alloy, FBB8 (Fe-6.5Al-10Ni-10Cr-3.4Mo-0.25Zr-0.005B, weight percent), was studied in dry air. It is found that it possesses superior oxidation resistance at 1,023 and 1,123 K, compared with other creep-resistant ferritic steels [T91 (modified 9Cr-1Mo, weight percent) and P92 (9Cr-1.8W-0.5Mo, weight percent)]. At the same time, the calculation of the interfacial energies between the -iron and B2-type intermetallics (CoAl, FeAl, and NiAl) has been conducted.

36 MATERIALS SCIENCE↗

BULKI-Store v0.3.2

BULKI-Store is a distributed object storage system optimized for high-performance computing environments. Built with a Rust core and Python bindings, it efficiently manages scientific and machine learning datasets across HPC clusters. The system employs a client-server architecture with MPI integration, enabling seamless scaling on supercomputers like Perlmutter. BULKI-Store's object-oriented approach provides intuitive data organization with rich metadata support, contrasting with traditional file-based solutions. Key optimizations include selective checkpoint loading, unified checkpoint files, and object chunking for large data transfers. For machine learning workloads, BULKI-Store offers advantages through fine-grained access patterns, dynamic data sharing between training instances, and reduced memory pressure. Memory management features include strategic Python GC calls, minimized data copies, and batch processing capabilities. The system leverages Rayon's thread pool for asynchronous data prefetching and supports multiple CPU architectures (ARM64, x86, AMD, RISC-V). By combining performance optimizations with developer-friendly APIs, BULKI-Store addresses the complex data management challenges of modern HPC applications while maintaining compatibility across heterogeneous computing environments.

Zhang, Wei [Lawrence Berkeley National Laboratory ↗

Bridging the Gap on Data and Analysis for Distribution System Planning: Information That Utilities Can Provide Regulators, State Energy Offices and Other Stakeholders

Electric utilities conduct planning annually to ensure their distribution system meets technical standards, policies, and regulations; addresses forecasted grid conditions; satisfies customer needs; and advances utility priorities. The plan identifies grid deficiencies, analyzes potential solutions, and prioritizes capital investments and other expenditures. About 20 U.S. states and jurisdictions require regulated utilities to file some type of distribution system plan with the public utility commission for review. Requirements for sharing distribution system data and analyses vary widely, from few specific requirements to a detailed list of information that must be provided. While utilities conduct extensive analysis to develop distribution system plans, in most jurisdictions regulators and stakeholders do not know what data are available and how the utility uses the data in planning and investing. This report aims to bridge the gap by increasing understanding of the types of data and analyses utilities employ to develop distribution system plans and how the information affects their decision-making. The report describes information that states and stakeholders can ask for related to 11 data categories: -Forecasting loads and distributed energy resources (DERs) -Scenario analysis -Worst-performing circuits -Asset management strategy -Hosting capacity analysis -Value of DERs -Grid needs assessment -Cost-effectiveness framework for investments -Distribution system investment strategy and implementation -Geotargeted programs -Non-wires alternatives procurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Control on Availability and Cycling of Residential HVAC in a Real-World Experiment

Demand response is an important emerging part of smart grids and there is a large stream of research from theoretical and modeling perspectives. However, there is relatively little experimental evidence that could help researchers and building operators make informed decisions on best practices for modeling, developing, and deployment of control mechanisms. We contribute to the body of experimental research by providing numerical insights into the role and availability of residential HVAC systems for control. We share the findings on the duration of the cooling cycle, off cycle, and temperature settling time of HVAC systems from data collected from a smart neighborhood located in Atlanta, GA.

cycling↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode: Preprint

This paper explores the dispatch-ability of grid-forming (GFM) inverters in grid-connected and islanded mode. Grid-forming (GFM) inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generator (SG)) and follow the change of the load demand. However, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help the grid operator better manage their inverter-based resources (IBRs) for improved operation efficiency and reliability. Therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and SG) to output the target power for both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle of doing so is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, thus, dispatching active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one grid-following inverter and loads in both grid-connected and islanded mode. This pioneering work results in a practical guidance for power system energy management system (EMS) development to control a future grid with GFM and GFL inverters.

droop control↗

Reaching new solar heights: integrating high penetrations of PV into the power system

Installed capacity of solar photovoltaics (PV) continues to grow rapidly in the US. High penetrations and can create operational and reliability challenges. PV integration shares some attributes and mitigation strategies with wind, and differs in some key ways that will be discussed. This study investigates PV integration challenges and examines mitigation issues for utilities planning for high penetrations of PV, with a focus on the Western Interconnection of the US. System balancing becomes more difficult due to a duck‐shaped net load curve. Flexibility in the remaining generators, load, and the PV itself, is critical in balancing the system. Reliability impacts from PV have been studied less and addressed less than system balancing issues, but become more important at high penetrations. Understanding essential reliability services from PV, weak grid issues with PV, and distributed PV impacts on bulk power system reliability is critical for planning of high penetrations of PV.

Lew, Debra↗

Electricity Rate Designs for Large Loads: Evolving Practices and Opportunities 2026 Update

Electricity demand from large-load customers such as data centers is projected to grow significantly in the near term. While these large loads play an important role in advancing technology innovation and economic growth in the United States, meeting their energy needs requires utilities and regulators to consider important operational and financial risks, such as insufficient energy supply or underutilized investments, that can impact all customers. This paper builds on similar research published in January 2025, providing an overview of how utilities and regulators are managing these risks through different tariffs, including rate structures and electric service agreements. Regulators, utilities, customers, and other stakeholders can use this paper as a foundation when discussing issues and sharing perspectives on developing or reviewing large-load tariffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Managing time-substitutable electricity usage using dynamic controls

A predictive-control approach allows an electricity provider to monitor and proactively manage peak and off-peak residential intra-day electricity usage in an emerging smart energy grid using time-dependent dynamic pricing incentives. The daily load is modeled as time-shifted, but cost-differentiated and substitutable, copies of the continuously-consumed electricity resource, and a consumer-choice prediction model is constructed to forecast the corresponding intra-day shares of total daily load according to this model. This is embedded within an optimization framework for managing the daily electricity usage. A series of transformations are employed, including the reformulation-linearization technique (RLT) to obtain a Mixed-Integer Programming (MIP) model representation of the resulting nonlinear optimization problem. In addition, various regulatory and pricing constraints are incorporated in conjunction with the specified profit and capacity utilization objectives.

24 POWER TRANSMISSION AND DISTRIBUTION↗