At least 145 records · Page 8

A Post-Occupancy Monitored Evaluation of the Dimmable Lighting, Automated Shading, and Underfloor Air Distribution System in The New York Times Building

With aggressive goals to reduce national energy use and carbon emissions, the U.S. Department of Energy (DOE) will be looking to exemplary buildings that have already invested in new approaches to achieving the energy performance goals now needed at a national level. The New York Times Building, in New York, New York, incorporates a number of innovative technologies, systems and processes and could become model for widespread replication in new and existing buildings. A year-long monitored study was conducted to verify energy performance, assess occupant comfort and satisfaction with the indoor environment, and evaluate impact on maintenance and operations. Lessons learned were derived from the analysis; these lessons could help identify and shape policy, financial, or supporting strategies to accelerate diffusion in the commercial building market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An application of distributed processing - In the TDRSS ground communication fault isolation and monitoring system

A computer interface has been designed for the Fault Isolation and Monitoring System, a system providing qualitative and quantitative assessment of the communications between the Tracking and Data Relay Satellite System Ground Segment and NASA's Network Control Center. The functional requirements for the interface and the design philosophy are discussed, as are the methods and protocol used to implement the operator support software required to configure the monitoring system and to display and report the results of the analysis. The system relies on the use of intelligent terminals, with the human interface removed from the host computer.

Waddell, R. L., Jr.↗

Making real-time reactive systems reliable

A reactive system is characterized by a control program that interacts with an environment (or controlled program). The control program monitors the environment and reacts to significant events by sending commands to the environment. This structure is quite general. Not only are most embedded real time systems reactive systems, but so are monitoring and debugging systems and distributed application management systems. Since reactive systems are usually long running and may control physical equipment, fault tolerance is vital. The research tries to understand the principal issues of fault tolerance in real time reactive systems and to build tools that allow a programmer to design reliable, real time reactive systems. In order to make real time reactive systems reliable, several issues must be addressed: (1) How can a control program be built to tolerate failures of sensors and actuators. To achieve this, a methodology was developed for transforming a control program that references physical value into one that tolerates sensors that can fail and can return inaccurate values; (2) How can the real time reactive system be built to tolerate failures of the control program. Towards this goal, whether the techniques presented can be extended to real time reactive systems is investigated; and (3) How can the environment be specified in a way that is useful for writing a control program. Towards this goal, whether a system with real time constraints can be expressed as an equivalent system without such constraints is also investigated.

Marzullo, Keith↗

MODIS. Volume 1: MODIS level 1A software baseline requirements

This document describes the level 1A software requirements for the moderate resolution imaging spectroradiometer (MODIS) instrument. This includes internal and external requirements. Internal requirements include functional, operational, and data processing as well as performance, quality, safety, and security engineering requirements. External requirements include those imposed by data archive and distribution systems (DADS); scheduling, control, monitoring, and accounting (SCMA); product management (PM) system; MODIS log; and product generation system (PGS). Implementation constraints and requirements for adapting the software to the physical environment are also included.

Masuoka, Edward↗

Battery management system with distributed wireless sensors

A system for monitoring parameters of an energy storage system having a multiplicity of individual energy storage cells. A radio frequency identification and sensor unit is connected to each of the individual energy storage cells. The radio frequency identification and sensor unit operates to sense the parameter of each individual energy storage cell and provides radio frequency transmission of the parameters of each individual energy storage cell. A management system monitors the radio frequency transmissions from the radio frequency identification and sensor units for monitoring the parameters of the energy storage system.

25 ENERGY STORAGE↗

Demonstrating Distribution System Resiliency through Grid-Edge Microgrids, on a Multi-Site Networked Hardware-in-Loop Platform

With the increasing penetration of Distributed Energy Resources (DERs) at the grid-edge, power systems include more energy storage, remote switches, relays, voltage regulators, and other intelligent electronic devices (IED). Effective control of these grid-edge devices by using Advanced Distribution Management Systems (ADMS) can yield substantial improvements to the resiliency and power quality of distribution systems. In this paper, improvements to the resiliency of a distribution system are demonstrated using a multi-site evaluation environment consisting of a real-time Hardware-in-Loop (HIL) setup in which DERs and other IEDs are modeled; and an ADMS which monitors and is able to control the distribution system assets. The HIL model and the ADMS are located 2400 km away, with communication between the sites enabled by a data manager using Distributed Network Protocol 3 (DNP3), demonstrating the system's capabilities even over long distances. After a simulated transmission system failure in the HIL demonstration setup, DERs and other devices are operated to restore critical loads and node voltage profile (to within the 'nominal +/-5%' band) in the distribution system.

ADMS↗

Smart Meter Pinging and Reading Through AMI Two-Way Communication Networks to Monitor Grid Edge Devices and DERs

Today’s power distribution system is changing to a power-electronics-enabled distribution system, especially with the increasing penetration of distributed energy resources (DERs). To monitor and manage those electronic devices and DERs at the grid edge, the advanced metering infrastructure (AMI) with two-way communications presents great potential. At present, extensive research explores the upstream communication from smart meters to electric utilities (e.g., meter reading) but few examine the downstream communication from the utilities to smart meters (e.g., meter pinging). This article discusses the AMI two-way communication and its recent industrial practice in the U.S., especially for applying the smart meter pinging functionality to monitor grid-edge devices and DERs. This paper then develops the two-way communication model and the network calculus method to quantify the impact of the two-way communication on the AMI network. In the end, the proposed method is validated with ns-3 simulation using the modified 13-node test feeder and real-world feeder systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system↗

A post-occupancy monitored evaluation of the dimmable lighting, automated shading, and underfloor air distribution system in The New York Times Building

With aggressive goals to reduce national energy use and carbon emissions, the US Department of Energy will be looking to exemplary buildings that have already invested in new approaches to achieving the energy performance goals now needed at a national level. The New York Times Building, in New York, New York, incorporates a number of innovative technologies, systems and processes and could become a model for widespread replication in new and existing buildings. Post-occupancy data are invaluable in establishing confidence in innovation. A year-long monitored study was conducted to verify energy performance, assess occupant comfort and satisfaction with the indoor environment, and evaluate impacts on maintenance and operations. Lessons learned were derived from the analysis; these lessons could help identify and shape policy, financial, or supporting strategies to accelerate diffusion in the commercial building market.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Developing Use Cases for Evaluation of ADMS Applications to Accelerate Technology Adoption: Preprint

Grid modernization for the distribution systems comprise of the ability to effectively monitor and manage unplanned events while ensuring reliable operations. Integration of Distributed Energy Resources (DERs) and proliferation of autonomous smart controllers like microgrids and smart inverters in the distribution networks challenge the status quo of distribution system operations. Advanced Distribution Management System (ADMS) technologies are being increasingly deployed to manage the complexities of operating distribution systems. The ability to evaluate the ADMS applications in specific utility environments and for future scenarios will accelerate wider adoption of the ADMS and will lower the risks and costs of their implementation. This paper addresses the first step - identify and define the use cases for evaluating these applications. The applications that are selected for this discussion include Volt-VAr Optimization (VVO), Fault Location Isolation and Service Restoration (FLISR), Online Power Flow (OLPF)/Distribution System State Estimation (DSSE) and Market Participation. A technical description and general operational requirements for each of these applications is presented. The test scenarios that are most relevant to the utility challenges are also addressed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Distributed Hierarchical Framework for Autonomous Spacecraft Control

Future human space missions for exploring beyond low Earth orbit are in the conceptual design stage. One such mission describes a habitat in cis-lunar orbit that is visited by crew periodically, others describe missions to Mars. These missions have one important thing in common: the need for autonomy on the spacecraft. This need stems from the latency and bandwidth constraints on communications between the vehicle and ground control. A variable amount of autonomy may be necessary whether the spacecraft has crew on board or not. Spacecraft are complex systems that are engineered as a collection of subsystems. These subsystems work together to control the overall state of the spacecraft. As such, solutions that increase the autonomy of the spacecraft (called autonomous functions) should respect both the independence and interconnectedness of the spacecraft subsystems. This distributed and hierarchical approach to system monitoring and control is a key idea in the Modular Autonomous Systems Technology (MAST) framework. The MAST framework enables a component-based architecture that provides interfaces and structure to developing autonomous technologies. The framework enforces a distributed, hierarchical architecture for autonomous control systems across subsystems, systems, elements, and vehicles. An example autonomous system was implemented in this framework and tested using realistic spacecraft software and hardware simulations. This paper will discuss the framework, tests conducted, results, and future work.

Badger, Julia M.↗

High Penetration PV Deployment in the Arizona Public Service System

In an effort to better understand the impacts of high penetrations of photovoltaic (PV) generators on distribution systems, Arizona Public Service (APS) and its partners have begun work on a multi-year project to develop the tools and knowledgebase needed to safely and reliably integrate high penetrations of utility and residential scale PV. Building upon the APS Community Power Project - Flagstaff Pilot, this project will analyze the impact of PV on a representative feeder in northeast Flagstaff. To quantify and catalog the effects of the estimated 1.5 MW of PV that will be installed on the feeder (both smaller units at homes as well as large, centrally located systems), high-speed weather and electrical data acquisition systems and digital 'smart' meters are being designed and installed to facilitate monitoring and to build and validate comprehensive, high-resolution models of the distribution system. These models will be used to analyze the impacts of the PV on distribution circuit protection systems (including anti-islanding), predict voltage regulation and phase balance issues, and develop volt/var control schemes. The goal of this paper is to provide insight and lessons learned on the early stages of high penetration PV deployment. Primarily focusing on modeling and data acquisition, this paper describes the overall project, early results, and plans for future phases of the project.

14 SOLAR ENERGY↗

The Future of Low-Carbon Electricity

We review future global demand for electricity and major technologies positioned to supply it with minimal greenhouse gas (GHG) emissions: renewables (wind, solar, water, geothermal, and biomass), nuclear fission, and fossil power with CO2 capture and sequestration. We discuss two breakthrough technologies (space solar power and nuclear fusion) as exciting but uncertain additional options for low-net GHG emissions (i.e., low-carbon) electricity generation. In addition, we discuss grid integration technologies (monitoring and forecasting of transmission and distribution systems, demand-side load management, energy storage, and load balancing with low-carbon fuel substitutes). For each topic, recent historical trends and future prospects are reviewed, along with technical challenges, costs, and other issues as appropriate. Although no technology represents an ideal solution, their strengths can be enhanced by deployment in combination, along with grid integration that forms a critical set of enabling technologies to assure a reliable and robust future low-carbon electricity system.

09 BIOMASS FUELS↗

Distributive, Non-destructive Real-time System and Method for Snowpack Monitoring

A ground-based system that provides quasi real-time measurement and collection of snow-water equivalent (SWE) data in remote settings is provided. The disclosed invention is significantly less expensive and easier to deploy than current methods and less susceptible to terrain and snow bridging effects. Embodiments of the invention include remote data recovery solutions. Compared to current infrastructure using existing SWE technology, the disclosed invention allows more SWE sites to be installed for similar cost and effort, in a greater variety of terrain; thus, enabling data collection at improved spatial resolutions. The invention integrates a novel computational architecture with new sensor technologies. The invention's computational architecture is based on wireless sensor networks, comprised of programmable, low-cost, low-powered nodes capable of sophisticated sensor control and remote data communication. The invention also includes measuring attenuation of electromagnetic radiation, an approach that is immune to snow bridging and significantly reduces sensor footprints.

Frolik, Jeff↗

The Synchronous Meteorological Satellite /SMS/ system

The Synchronous Meteorological Satellite (SMS) system is described which is being utilized in a program to obtain day and night information on the earth's weather by means of earth imaging, retransmission of imaged data, meteorological data collection and relay, and space environment monitoring. The components and functions of the ground system are discussed together with the basic satellite payloads. The launch and orbit of SMS-A are reviewed, and the functions of the visible IR spin-scan radiometer are described in detail. Other systems and units discussed include the data collection system, solar environment monitor, weather-facsimile unit, and central data distribution system. It is noted that SMS-A was used to support the Global Atlantic Tropical Experiment and that the SMS system will be complemented by geostationary environmental satellites from ESRO, Japan, and the USSR.

Fordyce, D. V.↗

Launch Processing System

This paper presents a functional description of the Launch Processing System, which provides automatic ground checkout and control of the Space Shuttle launch site and airborne systems, with emphasis placed on the Checkout, Control, and Monitor Subsystem. Hardware and software modular design concepts for the distributed computer system are reviewed relative to performing system tests, launch operations control, and status monitoring during ground operations. The communication network design, which uses a Common Data Buffer interface to all computers to allow computer-to-computer communication, is discussed in detail.

Byrne, F.↗