An optimization framework for the network design of advanced district thermal energy systems

In this work, a topology optimization framework for district thermal energy systems is presented. The framework seeks to address the questions, for a given district, "What is the best subset of buildings to connect to a district thermal energy system, and by what network should they be connected, to minimize life cycle cost?" A particle swarm optimization approach is validated to address the selection of the subset of buildings, and a graph theory-based heuristic is validated for selection of the network topology for any candidate subset of buildings. The framework is applied to a prototypical urban district for illustrative purposes. Additionally, modeling of prototypical districts revealed reductions in source energy use intensity for heating and cooling of 21-25% through the use of advanced district energy systems relative to code-compliant, building level systems. The framework identifies solutions with life cycle cost values 14% to 72% lower than that of base case scenarios based on conventional design approaches, depending on the base case scenario selected. Analysis of the search space indicates that topology optimization facilitates reductions in life cycle cost, source energy use intensity, and carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Urban Combined Heat and Power with Integrated Renewables and Energy Storage

District energy systems efficiently provide thermal energy to multiple buildings and facilities through a network of shared infrastructure. Frequently, district energy systems are centered around combined heat and power (CHP) plants that generate electricity as well as heating and cooling to the local buildings. By providing both electricity and thermal energy from a single fuel source and central location, these systems use less fuel, decrease energy and operational costs, and reduce the need for heating and cooling equipment in individual buildings.

EMS, CHP, GWU↗

Simulation-Based Design and Optimization of Waste Heat Recovery Systems

This fact sheet features an R&D project that will develop a modeling platform that can quantify the value of a district energy system and its potential for waste heat recovery. The new software analysis platform will evaluate and optimize district energy systems to better utilize low-temperature waste heat from nearby commercial and industrial buildings. The platform will help project developers and engineers easily quantify the potential value and cost savings of community energy systems for both producers and consumers of waste heat.

Combined heat and power, CHP, District energy, Was↗

Developing a Robust Market for CHP: A Plan for Fostering Economic Development, Business Competitiveness and Resiliency in the Mid-Atlantic Region

The Department of Energy’s Mid Atlantic Combined Heat and Power Technical Assistance Partnership (MA CHP TAP) was established to develop public-private partnerships to advance the technology, policies, and programmatic support for combined heat and power (CHP), including its application in microgrids, heat to power and district energy. The MA CHP TAP’s work includes education and outreach as well as technical assistance to a variety of stakeholders including end-users (commercial, industrial, institutional and more), state decision makers, electric and gas utilities, trade associations and non-profit organizations. This assistance includes evaluating the economic, energy, reliability and environmental value of proposed systems. The MA CHP TAP represents the multi-state Mid- Atlantic region and is the CHP expert in the region who provides fact-based, un-biased information on CHP, including technologies, project development, project financing, local electric and natural gas utility interfaces, and related state best practice policies.

20 FOSSIL-FUELED POWER PLANTS↗

ComStock Measure Documentation: Ideal Thermal Air Loads

This study provides hypothetical thermal heating and cooling loads for ComStock models representing the U.S. commercial building stock. This measure scenario removes all HVAC models from the baseline ComStock building model and instead uses "ideal air" to meet loads. "Ideal air" can be thought of as an HVAC unit that mixes air at the zone exhaust condition with the specified amount of outdoor air, and then adds or removes heat and moisture at 100% efficiency to produce a supply air stream at the specified conditions. The resulting ideal thermal loads are represented under the "district" fuel type for both heating and cooling and can be found in both annual and timeseries results in the ComStock public dataset. This measure scenario does not represent any real technology or improvement, but rather, serves as a resource for thermal heating and cooling loads for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Analysis of HEATNETS for Geothermal Network Performance: Preprint

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer, rather than also comparing control systems responses. HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study shows that HEATNETS, while not intended to replace other modeling tools, can be a unique modeling tool for the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Comparative Analysis of HEATNETS for Geothermal Network Performance

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

City-Scale Building Anthropogenic Heating during Heat Waves

More frequent and longer duration heat waves have been observed worldwide and are recognized as a serious threat to human health and the stability of electrical grids. Past studies have identified a positive feedback between heat waves and urban heat island effects. Anthropogenic heat emissions from buildings have a crucial impact on the urban environment, and hence it is critical to understand the interactive effects of urban microclimate and building heat emissions in terms of the urban energy balance. Here we developed a coupled-simulation approach to quantify these effects, mapping urban environmental data generated by the mesoscale Weather Research and Forecasting (WRF) coupled to Urban Canopy Model (UCM) to urban building energy models (UBEM). We conducted a case study in the city of Los Angeles, California, during a five-day heat wave event in September 2009. We analyzed the surge in city-scale building heat emission and energy use during the extreme heat event. We first simulated the urban microclimate at a high resolution (500 m by 500 m) using WRF-UCM. We then generated grid-level building heat emission profiles and aggregated them using prototype building energy models informed by spatially disaggregated urban land use and urban building density data. The spatial patterns of anthropogenic heat discharge from the building sector were analyzed, and the quantitative relationship with weather conditions and urban land-use dynamics were assessed at the grid level. The simulation results indicate that the dispersion of anthropogenic heat from urban buildings to the urban environment increases by up to 20% on average and varies significantly, both in time and space, during the heat wave event. The heat dispersion from the air-conditioning heat rejection contributes most (86.5%) of the total waste heat from the buildings to the urban environment. We also found that the waste heat discharge in inland, dense urban districts is more sensitive to extreme events than it is in coastal or suburban areas. The generated anthropogenic heat profiles can be used in urban microclimate models to provide a more accurate estimation of urban air temperature rises during heat waves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Case Study on Condenser Water Supply Temperature Optimization with a District Cooling Plant

District cooling (DC) continues to proliferate due to increasing global cooling demands and economies of scale benefits; however, most district-scale modeling has focused on heating, and to the best of our knowledge, researchers have yet to model cooling plants featuring waterside economizers in DC settings. With the popular Modelica Buildings library expanding its capabilities to district scale, this study is one of the first to demonstrate how the open-source models can be used for detailed energy and control analysis of a DC plant. For a real-world case study, we developed and calibrated high-fidelity models for a DC system central plant at a college campus in Colorado, USA, and we optimized the condenser water supply temperature (CWST) setpoint for a DC plant across multiple time horizons using the Optimization library in Dymola. Results indicate that annual CWST optimization saves 4.7% annual plant energy, with less than 1% of additional energy savings gained through daily optimization. This confirms previous studies' findings that high frequency CWST optimizations are not necessary for the studied system.

chiller plant↗

Western Combined Heat and Power Technical Assistance Partnership (Final Technical Report)

Since 2018, the Western Combined Heat and Power Technical Assistance Partnership (CHP TAP) has been dedicated to advancing the adoption and implementation of Combined Heat and Power. The CHP TAP has diligently worked towards its mission of fostering end-user engagement, promoting technical solutions, and enhancing energy security within the region. As we reflect on our journey, we are proud to announce the completion of the required metrics set forth at the beginning of our endeavor. From the outset, our aim has been clear: to leverage CHP technology as a catalyst for bolstering American competitiveness, utilizing local fuels, and fortifying energy resilience. Through collaborative efforts with a diverse array of stakeholders, including manufacturing, commercial, institutional, and federal facilities, and campuses, we have strived to realize this vision. In this report, we outline the achievements, activities, and impact of the Western CHP TAP, highlighting the transformative journey undertaken since 2018. From providing technical assistance and guidance to conducting educational workshops and advocating for supportive policies, our initiatives have been guided by a commitment to excellence and innovation. As we celebrate the completion of our required metrics, we reaffirm our dedication to continuing our mission, building upon our accomplishments, and shaping a sustainable energy future for the Western region. Through ongoing collaboration and engagement, we are confident that the Western CHP TAP will continue to serve as a beacon of progress and a catalyst for positive change in the years to come.

03 NATURAL GAS↗

Winnett Public School District Energy Improvements

The Winnett Public School District Energy Improvement Project was funded through the U.S. Department of Energy's Renew America's Schools Program, which supports rural and underserved school districts in upgrading aging facilities and improving energy performance. The completed improvements directly advance the program's objectives by replacing the District's outdated coal-fired heating system with a modern, high-efficiency propane boiler system, while also enhancing ventilation systems and building envelope performance throughout the school. These upgrades provide a more reliable heating system and improved indoor air quality, creating a healthier and more comfortable environment for students and staff. In addition, replacing the aging boiler system has reduced long-term maintenance demands for one of Montana's most rural school districts, allowing the District to redirect limited financial resources toward other critical needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

District EnErgy Planner (DEEP) v2

The District EnErgy Planner - DEEP is an Mixed Integer Linear Programming (MILP) optimization software tool to solve district energy system, technology configuration, operation strategies, and energy retail business schemes. DEEP takes user input energy demand on heating, cooling and electricity demand. Energy loss through pipeline is calculated for heating and cooling from central plants. The optimal system configuration to minimize the district energy system life cycle cost or minimize CO2 emission is calculated based on energy balance equations and various constraints. The recent update on DEEP include a feature of waste heat utilization energy balance based optimization to take into accounts of different temperature bands of heat into account to maximize system efficiency. Another feature is to optimize district energy retail by provide optimal pricing scheme for heating, cooling and electricity to end users to incorporate district to grid demand response.

Feng, Wei↗

Modeling Thermal Interactions between Buildings in an Urban Context

Thermal interactions through longwave radiation exchange between buildings, especially in a dense urban environment, can strongly influence a building’s energy use and environmental impact. However, these interactions are either neglected or oversimplified in urban building energy modeling. We developed a new feature in EnergyPlus to explicitly consider this term in the surface heat balance calculations and developed an algorithm to batch calculating the surrounding surfaces’ view factors using a ray-tracing technique. We conducted a case study with a district in the Chicago downtown area to evaluate the longwave radiant heat exchange effects between urban buildings. Results show that the impact of the longwave radiant effects on annual energy use ranges from 0.1% to 3.3% increase for cooling and 0.3% to 3.6% decrease for heating, varying among individual buildings. At the district level, the total energy demand increases by 1.39% for cooling and decreases 0.45% for heating. We also observe the longwave radiation can increase the exterior surface temperature by up to 10 °C for certain exterior surfaces. These findings justify a detailed and accurate way to consider the thermal interactions between buildings in an urban context to inform urban planning and design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Passive cooling designs to improve heat resilience of homes in underserved and vulnerable communities

Disadvantaged communities face a growing threat to staying safe during heat waves, especially during coincident power outages. This study develops a methodology to evaluate the effectiveness of passive cooling measures (those that operate without power) to improve residential building heat resilience. Building performance is simulated for representative homes and on district scales in two disadvantaged communities in Fresno, California. Eleven passive measures are evaluated using four heat resilience metrics with and without grid power. Results show performance of the mitigation measures varies by building characteristics, surrounding environment, and power scenario. The two most effective measures were installing solar-control window films and adding roof insulation. For pre-1978 single-family homes, these two measures can reduce unmet degree-hours (UDH) indoors by 12% and 11% respectively without grid power, or 28% and 37% with grid power. Their respective UDH reductions at district scale typically range 8% — 20% and 4% — 12% without grid power, or 14% — 44% and 8% — 51% with grid power. Top floors have higher overheating risk than lower floors during extreme heat events with coincident power outages. Natural ventilation can help, reducing UDH by 21% — 26%. The methodology and findings from this study can help cities, communities, and utilities develop effective and targeted strategies to promote greater residential heat resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A dynamic 2D Borehole Thermal Energy Storage (BTES) model for enhanced computational efficiency

Progressing toward a future increasingly reliant on renewable energy sources, the development of effective, durable energy storage solutions becomes essential to balance supply and demand fluctuations. Borehole Thermal Energy Storage (BTES) is a long-duration thermal energy storage technology that captures excess heat generated from renewable energy sources and stores it underground for later use, enabling the efficient utilization of sustainable energy. This approach is particularly valuable in district energy networks when integrated with Ground Source Heat Pumps (GSHP) to provide stable heating and cooling. However, traditional three-dimensional (3D) numerical models of BTES systems demand extensive computational resources, limiting their practicality for real-time and large-scale applications. This study introduces a novel two-dimensional (2D) modeling approach that reduces computational costs while maintaining high accuracy. By employing a radial ring-based discretization method, the model simulates heat injection, retention, and retrieval dynamics over seasonal cycles. A new thermal-mass weighted-average temperature parameter is introduced to evaluate the performance of BTES systems. Model validation against FEFLOW simulations demonstrates a 17-fold improvement in computational speed compared to traditional Computational Fluid Dynamics (CFD) models while achieving a mean absolute percentage error (MAPE) of 2 % during charging and 4 % during discharging. Additionally, a trade-off analysis between computational efficiency and accuracy is conducted, ensuring the model's applicability for real-world scenarios. The findings of this research contribute to the development of computationally efficient BTES models, facilitating better optimization, control, and integration into renewable energy systems. This work provides a foundation for further studies in techno-economic analysis, multi-year performance evaluation, and real-time operational strategies for BTES applications, supporting a more sustainable energy future.

2D modeling↗

Advanced District Energy Controls for Improved Efficiency and Resilience

District energy (DE) systems have efficiently provided heat and cooling to buildings in the US for over a century by leveraging economies of scale through shared generation assets. However, optimizing DE boiler and chiller plants is complex due to the intricate mix of equipment and multiple operating flows. Sophisticated controls are necessary to achieve highest efficiencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flexible Natural Gas/Hydrogen CHP System

This project included design, development, and demonstration of a cost-effective and scalable, unique-to-the-industry 2.0 MWe fuel-flexible Caterpillar G3516 CHP genset that can run on 100% hydrogen, 100% natural gas, and up to 25% blends of hydrogen in natural gas (volume basis). This was accomplished based on over two years of extensive R&D work done on a single-cylinder engine for developing innovative hydrogen fueling, combustion, air, and electronic control systems design and strategies. Findings from the single-cylinder engine work were scaled up and applied for modifications of and lab testing and development of a 2.0 MWe 16-cylinder G3516 fuel-flexible engine-genset and electronic controls systems. During this testing and development in the engine lab, the genset was run on 100% hydrogen, 100% natural gas, and up to 25% blends of hydrogen in natural gas (volume basis) and its steady-state and transient performance and emission were documented.

03 NATURAL GAS↗

A Simplified Tool for Rapidly Deploying Feasibility Analytics for the Non-Technical User

District energy systems efficiently provide thermal energy to multiple buildings and facilities through a network of shared infrastructure. Frequently, district energy systems are centered around combined heat and power (CHP) plants that generate electricity, as well as heating and cooling, to the local buildings. By providing both electricity and thermal energy from a single fuel source and central location, these systems use less fuel, decrease energy and operational costs, and reduce the need for heating and cooling equipment in individual buildings.