Search NASA⌕ Search

SEARCH · Search NASA

Results for “drop impact”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Evaluation of Rail Decarbonization Alternatives: Framework and Application

The Northwestern University Freight Rail Infrastructure & Energy Network Decarbonization (NUFRIEND) framework is a comprehensive industry-oriented tool for simulating the deployment of new energy technologies including biofuels, e-fuels, battery-electric, and hydrogen locomotives. By classifying fuel types into two categories based on deployment requirements, the associated optimal charging/fueling facility location and sizing problem are solved with a five-step framework. Life-cycle analysis (LCA) and techno-economic analysis (TEA) are used to estimate carbon reduction, capital investments, cost of carbon reduction, and operational impacts, enabling sensitivity analysis with operational and technological parameters. Here, the framework is illustrated on lower-carbon drop-in fuels as well as battery-electric technology deployments for the US Eastern and Western Class I railroad networks. Drop-in fuel deployments are modeled as admixtures with diesel in existing locomotives, while battery-electric deployments are shown for varying technology penetration levels and locomotive ranges. When mixed in a 50% ratio with diesel, results show biodiesel’s capacity to reduce emissions at 36% with a cost of $\$$ 0.13 per kilogram of CO 2 reduced, while e-fuels offer a potential reduction of 50% of emissions at a cost of $\$$ 0.22 per kilogram of CO 2 reduced. Battery-electric results for 50% deployment over all ton-miles highlight the value of future innovations in battery energy densities as scenarios assuming 800-mi range locomotives show an estimated emissions reduction of 46% with a cost of $\$$ 0.06 per kilogram of CO 2 reduced, compared with 16% emissions reduction at a cost of $\$$ 0.11 per kilogram of CO 2 reduced for 400-mi range locomotives. The NUFRIEND framework provides a systematic method for comparing different alternative energy technologies and identifying potential challenges and benefits in their future deployments.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance Assessment of Photovoltaic Panels Using Impedance Spectroscopy

The goal of this project was to develop a technique for measuring internal characteristics of a PV module using light modulation under a fixed voltage bias while measuring the resulting alternating current. This technique, light-intensity modulated impedance spectroscopy (LIMIS), has the promise of detecting early signs of panel aging and degradation that could be used for example by solar farm operators to have early warnings to repair or replace panels to maintain reliability of the overall PV array. LIMIS would be complementary with the previously developed electrochemical impedance spectroscopy (EIS), which uses an alternating voltage applied electrically to a solar cell with a similar alternating current measurement. EIS has mostly been developed for individual PV cells rather than whole modules. The project was intended to assess what different information could be revealed by LIMIS, which may in some cases be more scalable to larger modules and potentially more practical to apply in field measurements without needing to electrically disconnect PV modules. We began with small 10 W PV modules and built a testbed capable of oscillating the light intensity with frequencies up to 50 kHz. In parallel, we built a large testbed for testing large 250 W PV modules. Meanwhile, we developed procedures for established measurement techniques: current–voltage (I–V), EIS, and electroluminescence (EL) imaging, where panels are subjected to forward bias while their infrared emission is recorded using a camera modified to be sensitive to IR wavelengths. In addition, we developed protocols for accelerated aging of PV modules in two ways. Thermal cycling from –40°C to +90°C simulates the diurnal temperature cycles on a rooftop. Mechanical stress by dropping a 227 g ball from a height of 1 m simulates damage such as that due to hail impacts.

14 SOLAR ENERGY↗

Global Building Decarbonization Trends and Strategies

It is evident from extreme weather patterns that climate change is impacting the whole world. The consequences in the form of unpredicted severe weather conditions, hurricanes, floods, and wildfires have been disrupting national economies and affecting lives across the globe. As the global economy is recovering from the COVID-19 pandemic, the temporary drop in greenhouse gas (GHG) emissions mainly caused due to travel bans and economic slowdowns is no longer the case and, moving forward, controlling the increase in GHG emissions has emerged as a global challenge. The impact of climate change has enabled an acknowledgement of the challenge and this coincided with the rapid development of clean energy technologies for buildings, transportation, and industrial sectors, while ensuring a significant reduction in costs for their wide implementation.

54 ENVIRONMENTAL SCIENCES↗

Measurement of Convective Heat Transfer Coefficients With Supercritical CO 2 Using the Wilson-Plot Technique

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in a smooth tube and compares the results with published correlations for validation. The paper also describes the Heat Exchange and Experimental Testing (HEET) rig recently designed and built at the U.S. Department of Energy’s (DoE’s) National Energy Technology Laboratory (NETL) in Morgantown, WV. Here, the Wilson-plot technique used for measuring the heat transfer coefficients is described along with the data reduction process. The Wilson-plot technique was chosen as the basis for the design of NETL’s HEET rig. Advantages of the Wilson-plot technique include the (1) ability to measure high convective heat transfer coefficients accurately, (2) ability to measure average heat transfer coefficient for complicated heat exchange geometries like those produced using additive manufacturing, (3) ability to measure heat transfer coefficients on both sides of a heat exchanger independently, and (4) simplicity of experimental setup. Capabilities of the HEET rig include pressure to 24 MPa (3500 psig), temperature to 538 °C (1000 °F), mass flow rate to 1.5 kg/s (3 lb/s), and Re to 500,000. The rig is designed to operate with pure CO 2 or a mixture of CO 2 and up to 10% N2 by volume to study the impact of gas mixtures typical of direct-fired sCO 2 power cycles on the convective heat transfer and pressure drop. Preliminary tests in the HEET rig were performed with smooth stainless-steel tube and pure CO 2 , and the results were compared with published correlations for Nusselt number (Nu) and friction factor. Over a Reynolds number (Re) range from 58,000 to 228,000, measured Nu was compared to predictions using the Dittus and Boelter equation (Kreith and Bohn, 1993, “Principles of Heat Transfer, West Publishing Company”) within 5% and measured friction factors were compared to predictions using the McAdams correlation (“McAdams, 1954, “Heat Transmission,” 3rd ed., McGraw Hill, New York)” for smooth tube to be within 5%.

42 ENGINEERING↗

Modeling Methods for Capturing System Interactions of Combined Technologies: A Study of PV + Battery

The costs of solar photovoltaics (PV) have been dropping in recent years, leading to increasing installations of solar PV systems and growing interest in how the technology will impact the electric grid at higher penetrations. Additionally, as battery costs decline it becomes important to understand the benefits and limitations of battery storage for the grid as well as potential benefits of co-locating battery storage and PV, particularly within the realm of future system planning. However, it is non-trivial to capture these potential benefits within a linearized capacity expansion model (CEM). This paper presents methodological developments to more fully represent the value and limitations of coupled PV and battery systems (PV + Battery) in CEMs using the Resource Planning Model (RPM), which co-optimizes capacity investments, transmission investments, and reduced-order dispatch in the Western Interconnection of North America through 2045. We use the model to simulate the evolution of the generation and transmission system under two core scenarios - a baseline scenario and a high renewable penetration scenario - coupled with sensitivities assuming low and midline PV and battery cost projections. When incorporating PV + battery, we find that it is important for CEMs to capture the ability of the coupled technology to provide firm capacity and reduce expected curtailment, compared to independent systems. These interactions can have even more dramatic impacts at higher solar penetrations.

14 SOLAR ENERGY↗

A Multidisciplinary Approach to Integrated Energy Systems: Advanced Nuclear Plants with Thermal Storage for Dynamic and Flexible Operation in Diverse Markets

Energy supply, distribution, and demand are continuously evolving in accordance with the integration of new power generation sources. In the United States, there is a progressive shift toward incorporating fluctuating energy sources such as wind and solar into the energy mix, alongside the distributed generation. Simultaneously, we are seeing a revolution in consumer technologies such as electric vehicles, energy devices for both residential and commercial use, and industrial processes—all contributing to a fundamental change in energy consumption dynamics. These scenarios have led to huge demand for enhanced flexibility from nuclear power plants (NPPs), requiring them to operate with unprecedented adaptability. Furthermore, advanced NPPs (A-NPPs) could potentially apply to scenarios in which power generation flexibility is prioritized over its current and conventional baseload generation capacity for traditional demand patterns. The present work covers several configurations for coupling nuclear energy production with thermal energy storage (TES). Previous work evaluated systems entailing a simple nuclear-TES configuration that used steam as a heat source for the TES of three different advanced reactors (ARs), but its heat diversion ratio (HDR) for charging was limited. The present work proposes a new configuration that features full decoupling of the nuclear reactor and the power cycle, using reactor coolant (i.e., gas) as a heat source for the TES and offering a theoretically unlimited HDR. This configuration is, however, more complex, as both high- and low-temperature TES (HT-TES and LT-TES) systems are required in order to cover the extended temperature range. Although this configuration imposes certain limitations on the discharge system configuration, it also presents the opportunity to design a more efficient system. For this case in particular, a steam reheat cycle is advantageous. Conventional TES systems take advantage of nominal efficiency when discharging, whereas the reheat cycle in the fully decoupled TES system affords a significant efficiency increase over conventional cases. Material selection, component/equipment sizing, and costing analyses were performed, followed by economic dispatch and size optimization. Dynamic models were developed for the decoupled system in order to generate insights into aspects of off design operation (e.g., drops in cycle efficiency), and these models enable exploration of potential mitigation strategies for addressing such drops. The models also highlight the need to design fail-safes that ensure continuous operational stability and minimize the impact of power ramping on the reactor parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Contributions of Solar + Storage to Future Power Needs

The costs of solar photovoltaics (PV) have been dropping in recent years, leading to increasing installations of solar PV systems and growing interest in how the technology will impact the electric grid. Additionally, as battery costs decline, there is increasing interest in understanding the benefits and limitations of battery storage for the grid as well as potential co-benefits of coupling battery storage and photovoltaics. This paper presents recent methodological developments to more accurately represent the value and limitations of coupled PV and battery systems in capacity expansion models. These are demonstrated using the Resource Planning Model (RPM), which co-optimizes capacity investments, transmission investments, and reduced-order dispatch through 2045. We simulate the evolution of the generation and transmission system in the Western Interconnection both with and without a coupled PV and battery technology option under two core scenarios - a baseline scenario and a high renewable penetration scenario - coupled with sensitivities assuming low and mid PV and battery cost projections. We analyze the degree to which a variety of configurations of coupled PV + Battery systems are able to meet future electricity needs, under which system conditions this coupled technology becomes beneficial to the electric grid and identify the displaced technologies when coupled solar and storage is introduced into the model. We find that capturing the benefits of co-locating these systems becomes increasingly important as the penetration of solar PV rises, and that in particular it is important to accurately capture the ability of these technologies to shift energy, provide firm capacity, and reduce expected curtailment.

14 SOLAR ENERGY↗

Recent Progress in Electrochemical Upgrading of Bio-Oil Model Compounds and Bio-Oils to Renewable Fuels and Platform Chemicals

Sustainable production of renewable carbon-based fuels and chemicals remains a necessary but immense challenge in the fight against climate change. Bio-oil derived from lignocellulosic biomass requires energy-intense upgrading to produce usable fuels or chemicals. Traditional upgrading methods such as hydrodeoxygenation (HDO) require high temperatures (200–400 °C) and 200 bar of external hydrogen. Electrochemical hydrogenation (ECH), on the other hand, operates at low temperatures (<80 °C), ambient pressure, and does not require an external hydrogen source. These environmental and economically favorable conditions make ECH a promising alternative to conventional thermochemical upgrading processes. ECH combines renewable electricity with biomass conversion and harnesses intermediately generated electricity to produce drop-in biofuels. This review aims to summarize recent studies on bio-oil upgrading using ECH focusing on the development of novel catalytic materials and factors impacting ECH efficiency and products. Here, electrode design, reaction temperature, applied overpotential, and electrolytes are analyzed for their impacts on overall ECH performance. We find that through careful reaction optimization and electrode design, ECH reactions can be tailored to be efficient and selective for the production of renewable fuels and chemicals. Preliminary economic and environmental assessments have shown that ECH can be viable alternative to convention upgrading technologies with the potential to reduce CO2 emissions by 3 times compared to thermochemical upgrading. While the field of electrochemical upgrading of bio-oil has additional challenges before commercialization, this review finds ECH a promising avenue to produce renewable carbon-based drop-in biofuels. Finally, based on the analyses presented in this review, directions for future research areas and optimization are suggested.

09 BIOMASS FUELS↗

CFD Benchmark of Pressure Drop in a 61-Pin Wire-Wrapped Assembly with Blocked Channels Using NekRS

Thermal hydraulic behaviors of wire-wrapped rod bundles continue to be a subject of intense research. One of the leading next-generation designs, the sodium fast reactor, relies on a hexagonal assembly of wire-wrapped fuel pins. The issue of potential channel blockage has been raised as a safety concern due to the tightly packed arrangement of the fuel pins. This has led to several recent experimental and computational studies working to quantify the potential impact on the fluid flow and heat transfer behaviors of such blockages. The objective of the present study is to benchmark the high-fidelity NekRS CFD solver in predicting pressure drop for large blockages against available experimental data. A 61-pin wire-wrapped fuel assembly with two flow blockage configurations has been simulated and investigated at various low to moderate Reynolds numbers. The NekRS solver has been shown to yield exponentially decreasing spatial discretization errors with increasing polynomial order. All simulated results agreed well with measured data, which indicates that the overall methodology is adequate and consistent. The results of this benchmark study demonstrate the accuracy of NekRS for sodium fast reactor hydrodynamic simulations, increasing the confidence in its use for design, licensing, and analysis activities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Row spacing as a controller of solar module temperature and power output in solar farms

We report that when the temperature of solar photovoltaic modules rises, efficiency drops and module degradation accelerates. The spatial arrangement of solar modules can affect convective cooling and, consequently, module temperatures. However, the impact of row spacing on convective cooling in realistic solar farms has not yet been studied. Here, we develop six solar farm arrangements consisting of a fixed number of rows with varying streamwise row spacing. We model the flow and heat transfer of each solar farm using high-resolution large-eddy simulations. Results indicate that increasing row spacing can enhance convective cooling by 14.8%, which reduces module temperature by 6.6 °C and increases power output by 4.0% on average.

14 SOLAR ENERGY↗

Waiting in Queue: A Historical Evaluation of Interconnection Policy

Both states and Independent System Operators (ISO)/Regional Transmission Organizations (RTO) have struggled with long wait times in interconnection queues. As a result, numerous reforms have been proposed to expedite the connection of new resources to the grid. This paper conducts a quantitative analysis of two of these policies: one providing detail hosting capacity information in Massachusetts, the other experimenting with cost allocation in New York. We find that both policies led to a statistically significant decrease in the times projects spend pending in interconnection queues, with New York seeing a small drop in days pending, and Massachusetts seeing a much larger one. We also include an analysis of how energy storage is impacts queue time in these states. These results can help inform regulators who are weighing reforms to interconnection policies, with the goal of reducing wait times.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Numerical Investigation of Two-Stage Vapor Compression System with Simultaneous Vapor and Liquid Injection

Two-stage vapor compression systems can be advantageous over single-stage systems by providing improved system performance, lower discharge temperature and reduced throttling losses. These systems employ various intermediate configurations, such as liquid injection and vapor injection. This paper presents a configuration for a R1234ze(E) two-stage air-conditioning system using a turbo compressor with two injection ports, one for vapor injection and the second for liquid injection. The liquid injection is used to cool the motor and electronics. A component-based representation and solution approach was used to simulate the two-stage compression system with simultaneous vapor and liquid injection at steady state. The turbo compressor was represented using a customized performance map. The condenser and the evaporator were modeled using finite-volume approach. A parametric study was conducted to assess the impact of the following three variables on the system performance: vapor injection ratio, condenser air flow rate, and discharge pipe pressure drop. The simulation results show that as the vapor injection ratio increased, the system performance undergoes a tradeoff between an enhanced subcooling effect (and thus enhanced unit refrigeration capacity) and a decreased suction mass flow rate. Maximum COP occurs when the vapor injection ratio was 0.1. The results also show that as the condenser air flow rate increased, both the capacity and power consumption (including fan power) increased monotonically, and COP increased first and then decreased. At 75% load, the COP improvement at the optimum flow rate was marginally less than 0.5%. Lastly, higher discharge pipe pressure drop increased the discharge pressure. It showed very small effect on the overall system performance at the condition selected for the current study.

component-based steady-state simulation↗

3D Printing of Liquid Crystal Elastomer Foams for Enhanced Energy Dissipation Under Mechanical Insult

Polymer foams are an essential class of lightweight materials used to protect assets against mechanical insults, such as shock and vibration. Two features are important to enhance their energy absorption characteristics: the foam structure and the matrix phase mechanical behavior. This study investigates novel approaches to control both of these features to enhance the energy absorption capability of flexible lattice foams. First, we consider 3D printing via digital light processing (DLP) as a method to control the foam mesostructure across a suite of periodic unit cells. Second, we introduce an additional energy dissipation mechanism in the solid matrix phase material by 3D printing the lattice foams with polydomain liquid crystal elastomer (LCE), which undergo a mechanically induced phase transition under large strains. This phase transition is associated with LC mesogen rotation and alignment and provides a second mechanism for mechanical energy dissipation in addition to the viscoelastic relaxation of the polymer network. Here, we contrast the 3D printed LCE lattices with conventional, thermomechanically near-equivalent elastomer lattice foams to quantify the energy-absorbing enhancement the LCE matrix phase provides. Under cyclic quasi-static uniaxial compression conditions, the LCE lattices show dramatically enhanced energy dissipation in uniaxial compression compared to the non-LCE equivalent foams printed with a commercially available photocurable elastomer resin. The lattice geometry also plays a prominent role in determining the energy dissipation ratio between the LCE and non-LCE foams. We show that when increasing the lattice connectivity, the foam deformation transitions from bending-dominated to stretching-dominated deformations, which generates higher axial strains in the struts and higher energy dissipation in the lattice foam, as stretching allows greater mesogen rotation than bending. The LCE foams demonstrate superior energy absorption during the repeated dynamic loading during drop testing compared with the non-LCE equivalent foams, demonstrating the potential of LCEs to enhance physical protection systems against mechanical impact.

3D printing↗

Multi–year analysis of rain–snow levels at Marquette, Michigan

This study uses observations from a ground-based instrument suite to investigate the rain-snow level in stratiform rainfall from January 2014 to April 2020 in the Upper Great Lakes Region. The height above the surface where ice melts to rain, the rain-snow level (RSL), influences microphysical assumptions in remote sensing precipitation retrievals and the ability of space-based radar to discriminate surface precipitation phase because of ground clutter. The instrument suite is installed at the Marquette, MI (MQT) National Weather Service station adjacent to Lake Superior. Rain events and the RSL are studied through a ground-based vertically profiling radar (Micro Rain Radar), a custom NASA-developed video disdrometer (Precipitation Imaging Package), and reanalyses products from ECMWF ERA5 and NASA MERRA-2. Further, distinct macro and micro physical characteristics are observed in precipitation events with shallow RSL ( < 1.8 km above ground level [AGL]) and intermediate RSL ( > 1.8 km AGL). Intermediate RSL correspond to rain events with relatively higher rain rates and a higher concentration of small drops in the drop size distributions (DSDs). Shallow RSL DSDs contain relatively higher concentrations of large drops with lower fall speeds suggesting that partially melted snowflakes may be reaching the surface. Reflectivity-rain-rate relationships are also impacted by microphysical differences associated with RSL regimes. Radar-detected RSL agree with reanalysis-derived melt levels- especially at wet-bulb isotherms of 0.5°C and 1°C. Seasonal differences such as shallow rain-snow levels in winter, fall, and spring have subsequent implications for satellite detectability.

54 ENVIRONMENTAL SCIENCES↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

Investigating the relationship between microbial network features of giant kelp “seedbank” cultures and subsequent farm performance

Microbial inoculants can increase the yield of cultivated crops and are successful in independent trials; however, efficacy drops in large-scale applications due to insufficient consideration of microbial community dynamics. The structure of microbiomes, in addition to the impact of individual taxa, is an important factor to consider when designing growth-promoting inoculants. Here, we investigate the microbial network and community assembly patterns of Macrocystis pyrifera gametophyte germplasm cultures (collectively referred to as a “seedbank”) used to cultivate an offshore farm in Santa Barbara, California, and identify network features associated with increased biomass of mature sporophytes. We found that [1] several network features, such as clustering coefficient and edge ratios, significantly vary with biomass outcomes; [2] gametophytes that become low- or high-biomass sporophytes have different hub taxa; and [3] microbial community assembly of gametophyte germplasm cultures is niche-driven. Overall, this study describes microbial community dynamics in M . pyrifera germplasm cultures and ultimately supports the development of early life stage inoculants that can be used on seaweed cultivars to increase biomass yield.

Osborne, Melisa G. (ORCID:0000000154980057)↗

Impact of lithium wall conditioning and wave-frequency on high density lower hybrid current drive experiment on EAST

A series of dedicated lower hybrid current drive (LHCD) experiments on EAST shows that lithium wall conditioning extends LH current drive and heating up to the line-averaged density of n ̅_e≈ 4x1019 m-3 for both 2.45 and 4.6 GHz. Current drive at such a high density is crucial for the development of long-pulse non-inductive scenarios on EAST. With lithiation, the LH power injection of 1.5 MW at 2.45 GHz resulted in a drop of loop voltage of ~ 0.3 V, which is a comparable loop voltage drop observed with 1.1 MW at 4.6 GHz. The observed decrease in loop voltage is attributed mostly to the RF heating effect. Another LHCD experiment suggests that lithium wall coating has a more significant impact on the scrape-off-layer (SOL) properties than changes in the Greenwald fraction. LHCD at 2.45 GHz still suffers from a loss of efficiency. Enhanced power ionization in front of the launcher may cause the onset of density-dependent wave instabilities. The rise in the midplane SOL density may also accelerate a transition in the divertor regime, leading to additional ionization and collisional losses in the X-point divertor plasma. Ray-tracing modeling supports that a lower wave frequency is more prone to collisional power loss. The experiments confirm that lithiation is a useful tool to control the SOL plasma, and suggest that density control in front of the launcher may be critical to mitigating power loss mechanisms in the plasma boundary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗