Search NASA⌕ Search

SEARCH · Search NASA

Results for “drying methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Damping and vibration considerations for the design of optical systems in a launch/space environment

Engineering philosophies for the design of optical systems launched into space and operating in a vacuum or cryovacuum environment are reviewed. Particular attention is given to sources of energy dissipation which are usually lumped under a single modal parameter denoted as the equivalent viscous damping coefficient. Caging and/or damping system components or application of viscoelastic materials and/or dry friction devices are considered to be alternative methods for stabilizing instruments sensitive to motion.

Richard, Ralph M.↗

Vacuum powder injector and method of impregnating fiber with powder

A method and apparatus uniformly impregnate stranded material with dry powder such as low solubility, high melt flow polymer powder to produce, for example, composite prepregs. The stranded material is expanded in an impregnation chamber by an influx of air so that the powder, which may enter through the same inlet as the air, penetrates to the center of the stranded material. The stranded material then is contracted for holding the powder therein. The stranded material and powder may be pulled through the impregnation chamber in the same direction by vacuum. Larger particles of powder which do not fully penetrate the stranded material may be combed into the stranded material and powder which does not impregnate the stranded material may be collected and reused.

Working, Dennis C.↗

Covariability in the Monthly Mean Convective and Radiative Diurnal Cycles in the Amazon

The diurnal cycle of convective clouds greatly influences the radiative energy balance in convectively active regions of Earth, through both direct presence, and the production of anvil and stratiform clouds. Previous studies show that the frequency and properties of convective clouds can vary on monthly timescales as a result of variability in the monthly mean atmospheric state. Furthermore, the radiative budget in convectively active regions also varies by up to 7 Wm-2 in convectively active regions. These facts suggest that convective clouds connect atmospheric state variability and radiation variability beyond clear sky effects alone. Previous research has identified monthly covariability between the diurnal cycle of CERES-observed top-of-atmosphere radiative fluxes and multiple atmospheric state variables from reanalysis over the Amazon region. ASVs that enhance (reduce) deep convection, such as CAPE (LTS), tend to shift the daily OLR and cloud albedo maxima earlier (later) in the day by 2-3 hr. We first test the analysis method using multiple reanalysis products for both the dry and wet seasons to further investigate the robustness of the preliminary results. We then use CloudSat data as an independent cloud observing system to further evaluate the relationships of cloud properties to variability in radiation and atmospheric states. While CERES can decompose OLR variability into clear sky and cloud effects, it cannot determine what variability in cloud properties lead to variability in the radiative cloud effects. Cloud frequency, cloud top height, and cloud microphysics all contribute to the cloud radiative effect, all of which are observable by CloudSat. In addition, CloudSat can also observe the presence and variability of deep convective cores responsible for the production of anvil clouds. We use these capabilities to determine the covariability of convective cloud properties and the radiative diurnal cycle.

Dodson, Jason B.↗

Some approaches to medical support for Martian expedition

Medical support in a Martian expedition will be within the scope of crew responsibilities and maximally autonomous. Requirements to the system of diagnostics in this mission include considerable use of means and methods of visualization of the main physiological parameters, telemedicine, broad usage of biochemical analyses (including "dry" chemistry), computerized collection, measurement, analysis and storage of medical information. The countermeasure system will be based on objective methods of crew fitness and working ability evaluation, individual selection of training regimens, and intensive use of computer controlled training. Implementation of the above principles implies modernization and refinement of the countermeasures currently used by space crews of long-term missions (LTM), and increases of the assortment of active and passive training devices, among them a short-arm centrifuge. The system of medical care with the functions of prevention, clinical diagnostics and timely treatment will be autonomous, too. The general requirements to medical care during the future mission are the following: availability of conditions and means for autonomous urgent and special medical aid and treatment of the most possible states and diseases, "a hospital", and assignment to the crew of one or two doctors. To ensure independence of medical support and medical care in an expedition to Mars an automated expert system needs to be designed and constructed to control the medical situation as a whole. c2003 Published by Elsevier Science Ltd.

Mars↗

Application of laser anemometry to cryogenic wind tunnels

The installation and tests conducted with the laser Doppler and transit anemometer in the 0.3-Meter Transonic Cryogenic Tunnel are described. Using residual particulates in the flow field, a series of free stream velocity measurements were conducted which agreed to within 1-percent of predicted values for a range of Mach numbers, 0.2 to 0.85, and temperatures, 100 to 250 K. Measurements about a shock wave provided an estimate of scattering particulate size of 4 microns or less. The particle concentration is approximately 3 x 10 to the 5th to 1.6 x 10 to the 6th/cu m. Necessary isolation of the plenum wall windows from ambient air with slightly positive pressure of dry nitrogen gas to prevent condensation on the window surface was achieved. This was accomplished through the use of large enclosures fixed to the tunnel wall. A second method used an additional sheet of thin plate glass to create the dry gas pocket next to the plenum window. The installation of a laser anemometer in the National Transonic Facility is examined. The laser transit anemometer has been tentatively selected for the initial entry because of its compact laser-optics package.

Hunter, W. W., Jr.↗

Templated native silk smectic gels

One aspect of the present invention relates to a method of preparing a fibrous protein smectic hydrogel by way of a solvent templating process, comprising the steps of pouring an aqueous fibrous protein solution into a container comprising a solvent that is not miscible with water; sealing the container and allowing it to age at about room temperature; and collecting the resulting fibrous protein smectic hydrogel and allowing it to dry. Another aspect of the present invention relates to a method of obtaining predominantly one enantiomer from a racemic mixture, comprising the steps of pouring an aqueous fibrous protein solution into a container comprising a solvent that is not miscible with water; sealing the container and allowing it to age at about room temperature; allowing the enantiomers of racemic mixture to diffuse selectively into the smectic hydrogel in solution; removing the smectic hydrogel from the solution; rinsing predominantly one enantiomer from the surface of the smectic hydrogel; and extracting predominantly one enantiomer from the interior of the smectic hydrogel. The present invention also relates to a smectic hydrogel prepared according to an aforementioned method.

Jin, Hyoung-Joon↗

Templated Native Silk Smectic Gels

One aspect of the present invention relates to a method of preparing a fibrous protein smectic hydrogel by way of a solvent templating process, comprising the steps of pouring an aqueous fibrous protein solution into a container comprising a solvent that is not miscible with water; sealing the container and allowing it to age at about room temperature; and collecting the resulting fibrous protein smectic hydrogel and allowing it to dry. Another aspect of the present invention relates to a method of obtaining predominantly one enantiomer from a racemic mixture, comprising the steps of pouring an aqueous fibrous protein solution into a container comprising a solvent that is not miscible with water; sealing the container and allowing it to age at about room temperature; allowing the enantiomers of racemic mixture to diffuse selectively into the smectic hydrogel in solution; removing the smectic hydrogel from the solution; rinsing predominantly one enantiomer from the surface of the smectic hydrogel; and extracting predominantly one enantiomer from the interior of the smectic hydrogel. The present invention also relates to a smectic hydrogel prepared according to an aforementioned method.

Jin, Hyoung-Joon↗

Templated Native Silk Smectic Gels

One aspect of the present invention relates to a method of preparing a fibrous protein smectic hydrogel by way of a solvent templating process, comprising the steps of pouring an aqueous fibrous protein solution into a container comprising a solvent that is not miscible with water; sealing the container and allowing it to age at about room temperature; and collecting the resulting fibrous protein smectic hydrogel and allowing it to dry. Another aspect of the present invention relates to a method of obtaining predominantly one enantiomer from a racemic mixture, comprising the steps of pouring an aqueous fibrous protein solution into a container comprising a solvent that is not miscible with water; sealing the container and allowing it to age at about room temperature; allowing the enantiomers of racemic mixture to diffuse selectively into the smectic hydrogel in solution; removing the smectic hydrogel from the solution; rinsing predominantly one enantiomer from the surface of the smectic hydrogel; and extracting predominantly one enantiomer from the interior of the smectic hydrogel. The present invention also relates to a smectic hydrogel prepared according to an aforementioned method.

Jin, Hyoung-Joon↗

Examination of Soil Moisture Retrieval Using SIR-C Radar Data and a Distributed Hydrological Model

A major objective of soil moisture-related hydrological-research during NASA's SIR-C/X-SAR mission was to determine and compare soil moisture patterns within humid watersheds using SAR data, ground-based measurements, and hydrologic modeling. Currently available soil moisture-inversion methods using active microwave data are only accurate when applied to bare and slightly vegetated surfaces. Moreover, as the surface dries down, the number of pixels that can provide estimated soil moisture by these radar inversion methods decreases, leading to less accuracy and, confidence in the retrieved soil moisture fields at the watershed scale. The impact of these errors in microwave- derived soil moisture on hydrological modeling of vegetated watersheds has yet to be addressed. In this study a coupled water and energy balance model operating within a topographic framework is used to predict surface soil moisture for both bare and vegetated areas. In the first model run, the hydrological model is initialized using a standard baseflow approach, while in the second model run, soil moisture values derived from SIR-C radar data are used for initialization. The results, which compare favorably with ground measurements, demonstrate the utility of combining radar-derived surface soil moisture information with basin-scale hydrological modeling.

Hsu, A. Y.↗

Microbial Monitoring of New Cleanrooms Used to Curate Astrobiologically Relevant Asteroid Samples from Bennu and Ryugu

Introduction: NASA has constructed two new cleanrooms to house materials from the OSRIS-REx and Hayabusa2 missions to the asteroids Ryugu (162173) and Bennu (101955), respectively. In accordance with standard astromaterials curation practices, these cleanrooms will be monitored for particulate contamination and maintained to ISO 5 equivalent standards1. Since the samples in these collections are expected to contain prebiotic organic compounds that may help explain the origin of life on Earth, these labs will also be monitored for organic and biological contamination2. Samples from Ryugu arrived on Earth in December, 2020. After basic characterization in Japan, NASA received a subset of these samples at the astromaterials curation facility in Houston in December of 2021. OSIRIS-REx is expected to return samples in September, 2023. Here we present preliminary microbial monitoring results from monthly monitoring of these new labs and the connected microtomy and staging areas that support them, as they are being commissioned. We also compare these results to baseline values for other astromaterials curation labs. We will also briefly describe additional cleaning efforts employed to reduce the bioburden in these new cleanrooms. Methods: Microbial samples were collected from surfaces using a dry macrofoam swab (Puritan Brand 2518051PFRNDFD). Swabs were also opened in the lab but not touched to any surfaces to function as negative controls. Samples and controls were processed inside a class II biosafety cabinet to avoid inadvertent cross contamination. The swabs were suspended in 15 ml of PBS (Phosphate Buffered Saline) and vortexed for 20 seconds to remove cells from the swab surface. The PBS was used to inoculate Petri dishes filled with TSA (Tryptic Soy Agar), Blood Agar, or Reasoners 2 agar to check for microbial growth. Each plate was inoculated with 0.1 ml of PBS. The TSA and blood agar plates were incubated at 35˚C and the Reasoners 2 agar plates were incubated at 25˚C for seven days. Petri dishes filled with Potato dextrose agar, Saboraud dextrose agar, or Saboraud dextrose agar with 0.1 mg/ml of chloramphenicol, an antibiotic, were used to check for fungal growth. These plates were inoculated with 0.3 ml of PBS and incubated at 30˚C. The remaining PBS was frozen at -80 ˚C for DNA sequencing. After incubation, isolates were counted and reisolated for identification. Isolates were identified using the VITEK23 system or by sequencing a portion of the 16S rRNA gene for bacteria or the ribosomal internal transcribed spacer (ITS) for fungi. Sequencing was performed with an ABI 3500 Sanger sequencer. Results: During our initial sampling, six of the seven sites sampled (86%) displayed bacterial or fungal growth. Samples collected from the staging areas and microtomy labs are not included in this calculation since those areas are maintained at a lower ISO 7 equivalent cleanliness standard. A month later, only three of the seven sites (43%) displayed bacterial growth. No fungal growth was detected in the second sampling. Since new equipment had been introduced to the Hayabusa2 lab since the first round of sampling, an additional three sampling sites were included in the second round of sampling. None of these sites displayed microbial growth. These sites will be included in all future sampling efforts. Bacterial isolates have been identified from the following genera at multiple time points: Micrococcus, Staphylococcus, and Bacillus. Isolates from the genera: Microbacterium, Nocardioides, Methylocystis, and Microvirga were identified in the initial sampling, but were not present at later time points. Identification of fungal isolates is in progress. Results are summarized in Table 1. Discussion: The recovery rate or percentage of positive samples4 was initially 86%, which is higher than the median recovery rate for comparable ISO 5 equivalent curation labs like Stardust (33%), Hayabusa (33%), and Cosmic Dust (50%). However, after a month of operation, the recovery rate for these same sites decreased to 43%, which is similar to what we observe in comparable curation cleanrooms with no microbial control requirements. Adding in the new sampling sites further decreases the recovery rate to 30%. With the reduction in recovery rate, we also observed a decrease in microbial diversity. At the first time point, we observed at least 10 different bacterial species and at least two different fungi. This is a higher diversity than the median values for comparable ISO 5 equivalent labs (2-4 isolates per sampling event). After the second sampling, we observed at least 4 bacterial species and no fungi, which is more consistent with comparable labs. We expect the recovery rate and diversity in both labs to continue to decrease as routine operation continues. We will use ultrapure hydrogen peroxide to disinfect equipment and work areas prior to opening any sample containers. Most of the bacterial and fungal isolates were detected on samples from the cleanroom floors. This is consistent with baseline results from other curation labs. Organisms from the genera Bacillus, Staphylococcus, and Micrococcus that were repeatedly detected are common in cleanrooms and on human skin5,6. These organisms are generally thought to be introduced when people enter the cleanroom. Microbacterium, Nocardioides, and Microvirga have also previously been identified in astromaterials cleanrooms, but not as frequently as Bacillus, Staphylococcus, and Micrococcus. Methylocystis is a novel genus in the astromaterials cleanrooms, but it was identified with low accuracy (93% match in the sequenced region of the 16S rRNA gene) and further work is needed to confirm this identification. Microbacterium is a diverse genus with isolates identified from terrestrial and aquatic sediments. Some species of Microbacterium are capable of degrading complex organic compounds found in crude oil. The presence of these bacteria in the OSIRIS REx and Hayabusa2 cleanrooms should be closely monitored. Methylocystis is a genus of methanotrophic bacteria capable of oxidizing methane. If this identification proves to be correct and it is detected again, it should be closely monitored as well. Under nominal operating conditions, samples should not ever encounter the cleanroom floor or other high traffic areas. If we observe an increase in the bioburden in sensitive work areas that appears to be influenced by organism transfer from high traffic areas like the floors, we can employ additional hydrogen peroxide treatments to disinfect high traffic areas. Routine microbial monitoring of these labs will ensure that NASA’s astromaterials collections remain pristine and useful for scientific study. Table 1. Sampling Locations and Colony Counts Bacterial CFUa Fungal CFU Bacterial CFU Fungal CFU Lab - Location 11/2/2021 11/2/2021 12/13/2021 12/13/2021 H2b-Floor 4 8 1 0 H2-staging pass through 3 0 0 0 H2-microtomy pass through TNTCc 0 0 0 H2 Microscope 1 NA NA 0 0 H2 Microscope 2 NA NA 0 0 H2-Table NA NA 0 0 OREXd- microtomy pass through 0 0 6 0 OREX – Anteroom pass through 0 0 0 0 OREX – Floor 1 2 0 0 OREX Witness Foil Table 3 0 1 0 Staging-Floor 16 0 15 0 Microtomy-Floor 3 0 2 0 a: CFU = Colony Forming Unit b: H2 = Hayabusa2 Lab c: TNTC = too numerous to count d: OREX = OSIRIS-REx Lab References: 1. ISO 14644-1:2015 - Cleanrooms and associated controlled environments -- Part 1: Classification of air cleanliness by particle concentration. 37 (2015). 2. McCubbin, F. M. et al. Space Sci Rev 215, (2019). 3. Pincus, D. H. Encyclopedia of Rapid Microbiological Methods (2005). 4. The United States Pharmacopeial Convention. USP General Chapter <1116> 17, 784–794 (2013). 5. Sheraba, N. S., Yassin, A. S. & Amin, M. BMC Research Notes 3, 278 (2010). 6. Utescher, C. L. de A., Franzolin, M. R., Trabulsi, L. R. & Gambale, V. Brazilian Journal of Microbiology 38, 710–716 (2007).

A B Regberg↗

Measurement of mass distribution of chemical species in aerosol particles

Aerosols may be generated through the nebulizing of solutions and the evaporation of their solvent, leaving the dry solute particles. Attention is presently given to a method for the direct determination of the masses of chemical species in individual aerosol particles on a continuous, real-time basis, using mass spectrometry. After the aerosol particles are introduced into the ion source of a quadrupole mass spectrometer, the particles impinge on a hot rhenium filament in the mass spectrometer's ion source. The resulting vapor plume is ionized by electron bombardment, and a pulse of ions is generated by each particle. The intensities of different masses in the ion pulses can then be measured by the mass spectrometer.

Sinha, M. P.↗

Preventing Molecular and Particulate Infiltration in a Confined Volume

Contaminants from an instrument's self-generated sources or from sources external to the instrument may degrade its critical surfaces and/or create an environment which limits the instrument's intended performance. Analyses have been carried out on a method to investigate the required purging flow of clean, dry gas to prevent the ingestion of external contaminants into the instrument container volume. The pressure to be maintained and the required flow are examined in terms of their effectiveness in preventing gaseous and particulate contaminant ingestion and abatement of self-generated contaminants in the volume. The required venting area or the existing volume venting area is correlated to the volume to be purged, the allowable pressure differential across the volume, the external contaminant partial pressure, and the sizes of the ambient particulates. The diffusion of external water vapor into the volume while it was being purged was experimentally obtained in terms of an infiltration time constant. That data and the acceptable fraction of the outside pressure into the volume indicate the required flow of purge gas expressed in terms of volume change per unit time. The exclusion of particulates is based on the incoming velocity of the particles and the exit flow speed and density of the purge gas. The purging flow pressures needed to maintain the required flows through the vent passages are indicated. The purge gas must prevent or limit the entrance of the external contaminants to the critical locations of the instrument. It should also prevent self- contamination from surfaces, reduce material outgassing, and sweep out the outgassed products. Systems and facilities that can benefit from purging may be optical equipment, clinical facilities, manufacturing facilities, clean rooms, and other systems requiring clean environments.

Scialdone, John J.↗

Fundamental Studies on Two-Phase Gas-Liquid Flows Through Packed Beds in Microgravity

In the typical operation of a packed-bed reactor, gas and liquid flow simultaneously through a fixed bed of solid particles. Depending on the application, the particles can be of various shapes and sizes and provide for intimate contact and high rates of transport between the phases needed to sustain chemical or biological reactions. The packing may also serve as either a catalyst or as a support for growing biological material. NASA has flown two of these packed-bed systems in a microgravity environment with limited or no success. The goal of this research is to develop models (with scale-up capability) needed for the design of the physicochemical equipment to carry out these unit operations in microgravity. New insight will also lead to improvements in normal gravity operations. Our initial experiment was flown using an existing KC-135 two-phase flow rig with a modified test section. The test section is a clear polycarbonate rectangular column with a depth of 2.54 cm, a width of 5.08 cm, and 60 cm long. The column was randomly packed with spherical glass beads by slowly dropping the beads into the bed. Even though care was taken in handling the column after it was filled with packing, the alternating high and low gravity cycles with each parabola created a slightly tighter packed bed than is typically reported for this type. By the usual method of comparing the weight difference of a completely dry column versus a column filled with water, the void fraction was found to be .345 for both sizes of beads used. Five flush mounted differential pressure transducers are spaced at even intervals with the first location 4 cm from the inlet port and the subsequent pressure transducers spaced at 13 cm intervals along the column. Differential pressure data was acquired at 1000 Hz to adequately observe pulse formation and characteristics. Visual images of the flow were recorded using a high-speed SVHS system at 500 frames per second. Over 250 different test conditions were evaluated along with a companion set of tests in normal gravity. The flow rates, fluid properties and packing properties were selected to provide a range of several orders-of-magnitude for the important dimensionless parameters. Additional information is included in the original extended abstract.

Balakotaiah, Vemuri↗

Genomic and Phenotypic Characterization of Yeast Biosensor for Deep-space Radiation

The BioSentinel mission was selected to launch as a secondary payload onboard NASA Exploration Mission 1 (EM-1) in 2018. In BioSentinel, the budding yeast Saccharomyces cerevisiae will be used as a biosensor to measure the long-term impact of deep-space radiation to living organisms. In the 4U-payload, desiccated yeast cells from different strains will be stored inside microfluidic cards equipped with 3-color LED optical detection system to monitor cell growth and metabolic activity. At different times throughout the 12-month mission, these cards will be filled with liquid yeast growth media to rehydrate and grow the desiccated cells. The growth and metabolic rates of wild-type and radiation-sensitive strains in deep-space radiation environment will be compared to the rates measured in the ground- and microgravity-control units. These rates will also be correlated with measurements obtained from onboard physical dosimeters. In our preliminary long-term desiccation study, we found that air-drying yeast cells in 10% trehalose is the best method of cell preservation in order to survive the entire 18-month mission duration (6-month pre-launch plus 12-month full-mission periods). However, our study also revealed that desiccated yeast cells have decreasing viability over time when stored in payload-like environment. This suggests that the yeast biosensor will have different population of cells at different time points during the long-term mission. In this study, we are characterizing genomic and phenotypic changes in our yeast biosensor due to long-term storage and desiccation. For each yeast strain that will be part of the biosensor, several clones were reisolated after long-term storage by desiccation. These clones were compared to their respective original isolate in terms of genomic composition, desiccation tolerance and radiation sensitivity. Interestingly, clones from a radiation-sensitive mutant have better desiccation tolerance compared to their original isolate without losing radiation sensitivity. We employed Next-Generation Sequencing technology to better understand this phenotypic variation. Current effort is focusing on the analysis of high-throughput sequencing data to look for genomic changes in these reisolated clones compared to their original isolate.

yeast↗

A comparison of wet and dry season ozone and CO over Brazil using in situ and satellite measurements

A comparison conducted between direct measurements of Brazilian ozone and NO concentrations and space-based measurements has indicated a strong correlation between the two environmental sensing methods and indicated the seasonality of both ozone and CO concentrations in this region. Dry season increases appear to be due to both increased local biomass burning and the transport of CO and ozone from Africa. The coincident high values of both CO and ozone suggest photochemical sources, rather than a stratospheric source, for the African and South American ozone.

Watson, Catherine E.↗

Establishing Cleaning Methods for Cleanroom and Safety Suits at Remote Sites with Available Resources

"The James Webb Space Telescope (JWST) spent considerable time in multiple clean facilities during its launch campaign at the Centre Spatial Guyanais (CSG) in French Guiana. Throughout this time, it was imperative that personnel wear approved cleanroom or safety suits when working in proximity to the JWST observatory. This proved to be challenging for two reasons: 1) A large quantity of NASA cleanroom suits needed to be shipped to CSG to account for the heavy volume of NASA and ESA personnel requiring access to the clean facilities. It became evident that shipping clean suits from the US to CSG in a timely fashion during the launch campaign would be challenging. Consequently, a backup plan needed to be established to avoid running out. 2) For safety purposes, Self-Contained Atmospheric Protection Ensemble (SCAPE) and Splash suits were required for hazardous operations. Neither type of suit was cleanroom compatible; therefore, a viable cleaning process needed to be developed to ensure both types of suits met JWST’s approved cleanliness standards. The NASA Contamination Control (CC) team partnered with CSG’s S5E cleanroom and suit processing team. The teams were able to make modifications to the S5E facility to create a NASA approved makeshift clean environment where NASA cleanroom suits and CSG Splash suits were inspected, folded, and bagged for cleanroom use once they were washed and dried. Since SCAPE suits could not be cleaned using conventional methods, a procedure was developed to clean and inspect the suits by the CC team in a temporary clean environment prior to fueling. "

James Webb Space Telescope↗

Establishing Cleaning Methods For Cleanroom And Safety Suits At Remote Sites With Available Resources

The James Webb Space Telescope (JWST) spent considerable time in multiple clean facilities during its launch campaign at the Centre Spatial Guyanais (CSG) in French Guiana. Throughout this time, it was imperative that personnel wear approved cleanroom or safety suits when working in proximity to the JWST observatory. This proved to be challenging for two reasons: 1) A large quantity of NASA cleanroom suits needed to be shipped to CSG to account for the heavy volume of NASA and ESA personnel requiring access to the clean facilities. It became evident that shipping clean suits from the US to CSG in a timely fashion during the launch campaign would be challenging. Consequently, a backup plan needed to be established to avoid running out. 2) For safety purposes, Self-Contained Atmospheric Protection Ensemble (SCAPE) and Splash suits were required for hazardous operations. Neither type of suit was cleanroom compatible; therefore, a viable cleaning process needed to be developed to ensure both types of suits met JWST’s approved cleanliness standards. The NASA Contamination Control (CC) team partnered with CSG’s S5E cleanroom and suit processing team. The teams were able to make modifications to the S5E facility to create a NASA approved makeshift clean environment where NASA cleanroom suits and CSG Splash suits were inspected, folded, and bagged for cleanroom use once they were washed and dried. Since SCAPE suits could not be cleaned using conventional methods, a procedure was developed to clean and inspect the suits by the CC team in a temporary clean environment prior to fueling.

James Webb Space Telescope↗

Spacecraft thermal blanket cleaning: Vacuum bake of gaseous flow purging

The mass losses and the outgassing rates per unit area of three thermal blankets consisting of various combinations of Mylar and Kapton, with interposed Dacron nets, were measured with a microbalance using two methods. The blankets at 25 deg C were either outgassed in vacuum for 20 hours, or were purged with a dry nitrogen flow of 3 cu. ft. per hour at 25 deg C for 20 hours. The two methods were compared for their effectiveness in cleaning the blankets for their use in space applications. The measurements were carried out using blanket strips and rolled-up blanket samples fitting the microbalance cylindrical plenum. Also, temperature scanning tests were carried out to indicate the optimum temperature for purging and vacuum cleaning. The data indicate that the purging for 20 hours with the above N2 flow can accomplish the same level of cleaning provided by the vacuum with the blankets at 25 deg C for 20 hours, In both cases, the rate of outgassing after 20 hours is reduced by 3 orders of magnitude, and the weight losses are in the range of 10E-4 gr/sq cm. Equivalent mass loss time constants, regained mass in air as a function of time, and other parameters were obtained for those blankets.

Scialdone, John J.↗